Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date13 Nov 2024
Closing Date28 Nov 2024
Tender Amount₹ 18,00,000
Costs
EMD
₹ 36,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683555_1Tender No
8012/1075/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S&F in repair cast iron non return valve ISI marked both ends flanged including rubber gasket, MS bolts, nuts, washers and testing complete all as specified and directed of the following size:-
-
-
-
(a) 100 mm dia.
4
-
-
(b) 150 mm dia.
4
-
-
S&F in repair sluice valve, Class PN-1.6 dia both end flanged with high tensile SS spindle with lock nut (gutka), ISI marked complete with jointing materials such as rubber packing, nuts, bolts & washers complete all as specified & directed.
-
-
-
(a) 100 mm dia.
4
-
-
(b) 150 mm dia.
3
-
-
S&F in repairs butterfly valve including check nut bolts complete all as specified and as directed by Engr-in-Charge of following size
-
-
-
(a) 50 mm dia.
7
-
-
(b) 80 mm dia.
4
-
-
Supply and fixing in repairs MCCB 4 Pole,415 V AC, Adjustable type, 200 Amps with breaking capacity 36 KA.
1
-
-
Supply and fixing in repairs MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA.Make - L&T/Havells/ Siemens/Legrand
1
-
-
Supply and fixing in repairs MCCB 4 Pole, 415 V, Adjustable type 100 Amps with breaking capacity 16 KA.Make - L&T/Havells/ Siemens/Legrand
2
-
-
Supply and fixing in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
2
-
-
Supply and fixing in repair LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete
3
-
-
Taking down monoblock pump set of 7.5 HP and transport to workshop for Rewinding of motor and servcing of pump set including replacement of bearing,ceiling etc of 415 Volt 3 phase 50 HZ complete with super enamelled wire of existing gauge and insulating material and refixing the same at existing or new place all as directed by Engr-in-Charge
1
-
-
Taking down monoblock pump set of 3 HP and transport to workshop for Rewinding of motor and servcing of pump set including replacement of bearing,ceiling etc of 415 Volt 3 phase 50 HZ complete with super enamelled wire of existing gauge and insulating material and refixing the same at existing or new place all as directed by Engr-in-Charge
3
-
-
Taking up/down vertical non clog sewage pump set any make and in any position alongwith column pipe from well after dewatering the well and disconnecting delivery end connection with the help of chain pully / tripod andoverhauling the pump re-threading of wornout holes of studs and providing over size studs with nuts & washers,cutting out existing copper winding and rewinding with same size copper winding. Rematlling and balancing of shaft, replacement of gunmetal bush, all bearing and gland packing of pump set. and refitting the same after the repair/replacement and lowering the pump set complete with column pipe in the well and fixing / connecting with existing delivery/suction complete all as specified and directed of the following size.
-
-
-
(a) 15 HP capacity
4
-
-
(b)10 HP to 12.5 HP capacity
4
-
-
(c ) 3 HP Capacity
3
-
-
Labour only for removal and disposal of sludge formed on the dry bed (6 Nos of dry bed) to a distance exc 1.5KM but not exc 3 KM i.e. out side the periphery of defence land from bed and well including cleaning of bar screen complete all as specified and directed.
20
-
-
M&L for removing the sludge /concrete peices/bricks bats deposited inside the well having sludge upto 6 feet + 1.0 Feet height from the bottom of well completely by manually without filling inside the pipe/suction/delivery line of pump and remove the sludge to a distance not more than 50 M from well after de-watering the sewage well with pump or any other method including removing the unwanted substances like polythene bags, chappels, plastic bottles etc complete all as directed by Engr-in-charge. Note :- (a) Contractor shall ensure the full safety of Labour working inside the well in all respect. (b) Safety belts, safety mask etc should be provided by the contractor for the persons working inside the well.
-
-
-
(a) 12 mtr deep and 6 mtr internal dia
4
-
-
(b) 7.0 mtr deep and 6 mtr internal dia
4
-
-
Cleaning of FAB reactor chamber, setteling tank, sludge collection chamber and clean water collection chamber, replacing air pipe of FAB reactor chambers complete all as specified and directed.
4
-
-
M & L for fiber base FAB media for development of bacterias round in shape/hexagonal devided in multi layers to increase the surface area of media (as per sample) ( MBBR Media MOC-P/P-HDPE- Virgin) complete all as specified and directed.
8
-
-
M & L for Tube settler Media MoC-HDPE, Hight 844m
4
-
-
M & L for servicing and testing of sewage treatment plant air compressor set of capacity 10 to 15 HP, 3 phase 415 volts by opening end cover, replacement connection lead ,greasing the both end of bearings and replacement of bearing ,meteling/policing of shaft,replcing worn out nut bolts ,gasket,air release valve key gland stuffing box male/female set, rubber bush, descalling of impeller and replacing of impellor key & neck ring (impellor guide) and other minor erpair required and painting one coat of synthetic enamal paint with connected LT panel complete all as specified and directed.
4
-
-
M&L for cleaning/opening the blockage in sewage line 200mm dia bore with sewage jet cleaning machine having capacity of cleaning up to 200 feet long in one attempt including earthworks complete all as specified and directed
8
-
-
M&L for cleaning/opening the blockage in sewage line 150mm dia bore with sewage jet cleaning machine having capacity of cleaning up to 200 feet long in one attempt including earthworks complete all as specified and directed
6
-
-
M&L for providing hypo solution of 6% concentration for treatment of sewage treated water complete all as specified and directed.
2000
-
-
S&F in repair flow meter for air compressor with conical type weight complete all as specified and directed.
4
-
-
M&L for applying one coat of superior quality synthetic enamel paint on the equipment installed at STP like air blower, pump motor and pipe line connected,Filter media plant alongwith connected pipeline and STP equipment complete all as specified and directed.
8
-
-
Repairs to leakage of GI/CI pipeline including fittings, such as tee, bends, tail pieces, connecting pieces etc including necessary earth works complete all as specified and directed of pipe are as under:-
-
-
-
(a) 200 mm dia.
6
-
-
(b) 150 mm dia.
8
-
-
(c) 100 mm dia.
4
-
-
Testing of effluent test from auth lab of waste water discharge from sewage treatment plant and record the parameter in register and report of the same submitted to MES office monthly by contractor rap.:- (Note :- collection of samples from STP to Lab and submission of test report is responsibilty of contractor)Test are as follows :-(a) pH value(b) Turbidity(c)TSS- Total suspended solids(d) Temprature(e) Dissolved Oxygen(f) Pordable Biochemical oxygen demand (g) Chemical oxygen demand(h) Total organic carbon
18
-
-
Taking up/down 150mm DI Pipe and Supply, laying and jointing in repair for 150 mm bore centrifugally cast (spun) ductile iron pressure pipes for water mains with socket & spigot ends conforming to IS 8329/2000 any length for classification of K7 suitable for rubber gasket joint (push on type) with cement mortar lining inside the pipe with outside zinc coating complete all including existing connection with required size of Tee or MS clamp with rubber bush as specified and directed.
50
-
-
Taking up/down MS GI/MS Pipe and Supply and Fixing in repair MS pipe 80 mm Medium Grade(B grade) confirming to IS:1239 Part-I (2004) SWS with all fitting/fixtures laid in trenches/Wall all as directed at site.
30
-
-
Taking up/down MS GI/MS Pipe and Supply and Fixing in repair MS pipe 50 mm Medium Grade(B grade) confirming to IS:1239 Part-I (2004) SWS with all fitting/fixtures laid in trenches/Wall all as directed at site.
180
-
-
Supply & fixing in replacement of old unserviceable GI column pipe 100mm dia, Heavy grade, both end flanged 3 mtr long complete with nut bolts washer and ruber washer for fixing of pipe suitable for non clogging sewage submersible motor pump set complete all as specified and directed.
15
-
-
Supply & Fixing in repair ML - 3 Type three Pole Power contactor conforming , AC operated of coil voltage 230 /415 Volt, 50 Hz AC 3 rating 200 Amp for AMF Panel, of
2
-
-
Supply and fix automatic relay for three phase power supply for AMF Panel of 125 KVA DG Set xvoltage upto 240/415 volt with display fixing in Existing panel all as directed by Engr-in-charge
1
-
-
Supply and fixing in repair star delta starter for mono block/sewage pump set of 15 HP 3 phase 415 volt all as directed by Engr-in-charge.
6
-
-
Supply and fixing in repair star delta starter for mono block/sewage pump set of 12.5 HP 3 phase 415 volt all as directed by Engr-in-charge
2
-
-
Supply and fixing in repair star delta starter for mono block/sewage pump set of 7.5 HP 3 phase 415 volt all as directed by Engr-in-charge
7
-
-
DI bends for spigot socketed DI K-7 class pipe 100mm bore (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch "Y" junction, double branch, cross (all socket or socket and spigot collors, caps and plugs) complete all as specified. Note: Cost of rubber tyton joints is deemed to be included in overall cost quoated.
100
-
-
Supply and fixing in repair 3 core flat submersible cable of size 4 sqmm of copper all as directed by Engr-in-charge
90
-
-
Supply and fixing in repair 3 core flat submersible cable of size 6 sqmm of copper all as directed by Engr-in-charge
90
-
-
Supply and fix Super 24 Chemical for Sewage treatment plant of bulk density 0.6-0.8 gr/cc light brown free flowing powder effective for Ph range 5-9 in packaging of 20 Kg bucket shell life not less than 1 year.Make :FLOSYS or equivalent
100
-
-
Supply and fix Oxy-Super chemical for STP for reduction of BOD,COD and TSS useful in treatment or contaimenated soils and sludges yellowish or white in colour,CAS number 1305-79-9,Bulk Density 0.91+ or - 0.5 not inflammable PH 11.5 in packaging of 20 Kg bucket.Make :FLOSYS or equivalent
100
-
-
Supply and fix in repair Digital type weight machine for measuring chemical upto 20 Kg for STP all as directed by Engr-in-charge.Make Killomax/Mogiflex
2
-
-
Supply and fixing systematic plan by computer print of sewage treatment plant on hard board of size 2 mtr x 1.5 mtr showing details of incoming and outgoing of water including detail of complete equipment alongwith capacity and specification all as directed at site.
1
-
-
Triming of trees,cutting of herbs and shrubs upto ground level,Cleaning of equipment by cotton waste and removing plants and other garbage material from STP Installation to nearest garbage bin not more than 2 km from site and cleaning of internal road/path all as directed at site by Engr-in-Charge.
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%