Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Eprocure
Opening Date15 Feb 2020
Closing Date28 May 2020
Tender Amount₹ 9,50,000
Costs
EMD
₹ 19,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MES_325298_1Bid Award Id
ViewTender No
8746/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and laying galvainesd steel tubing light grade 50 mm dia of bore fixed with pole/ surface of wall / laid in trench etc as site using 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc all as directed. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
10
-
-
Supply, laying, thembling, jointing, fixing with pole/ wall etc/ clamping on surface of wall to XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade aluminium conductor cross section area 50 Sqmm 3.5 core with suitable size of gland etc complete all as specified and directed.
Note :- Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
120
-
-
Supply and fixing LT end termination jointing kit suitable for 50 Sqmm x 4 core XLPE 1100 volt grade cable indoor type heat shinkable complete all as directed. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
6
-
-
Supply and fixing 4 pole off load change over switch, 100 Amps rated, 420 volt grade in sheet metal enclouser mounting on suitable size on wooden board minium 50 MM thick incl making all connection complete all as specifed and directed.
Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
1
-
-
Supply and fixing of 60 watt LED street light fitting energy saving IP 65 protection including making electric connection using three core copper flexible cable drawn through in PVC flexible conduit complete all as specified and directed. Note :- (i) Fitting shall be of Bajaj Cat No BRTFG 60W LED V3 ( EDGE) or Crompton cat Part No LSTP-60-CDL (NEXUS+) or equivalent model of make Philips/Wipro. Light fitting of other make of higher capacity may be used without any price adjustment. (ii) Cable from MCB/control Box to fitting shall be included in unit rate quoted by contractor.
5
-
-
Supply and fixed of flood light fitting LED 160/170 W equipped with IP66 protection with mounting bracket not bolt washer to be fix on pole/ wall etc all as site making all connection using suitable three core flexible copper cable drawn through in flexible conduit pipe from control box to light fittings complete all as directed.
Note :- (i) Fitting shall be of Bajaj (Turbo) cat No BARFEG 160W LED (white) or Crompton cat Part No LSFO-170-CDL/60 (Secure) or philips cat part No BVP410 LED 170 CW HE NB FG S4 XTFCL or equivalent model of make Wipro. Light fitting of other make of higher capacity may be used without any price adjustment. (ii) Cable from MCB to fitting shall be included in unit rate quoted by contractor.
8
-
-
Supplying, transporting to site, erecting, and fixing in position, steel tubular galvanized swaged pole, welded poles of 9 metre long, type 410 SP-31, with mild steel base plate / finial taper plug, bolts, nuts, washers etc, including painting on the outside with two coats of aluminium paint over a coat of red oxide primer on exposed surfaces and black bituminous paint on steel surface embeded in concrete and painting 03 numbers band /strips ( 30 cm wide each) with fluorescent synthetic enamel paint (in alternate colour of black & white) above plinth block and numbering of poles, complete all as directed by engineer-in-charge.
Note : (i) Steel tubular poles shall be swaged and welded at manufacturer’s factory and not at site. The inner surface shall be factory painted.
(ii) Excavation, PCC for foundation and pedastal shall be measured and paid for separately under respective items of this Schedule of works.
Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
2
-
-
Supply, laying, thembling, jointing, fixing with pole/ wall etc/ clamping on surface of wall to XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade aluminium conductor cross section area 10 Sqmm 2 core with suitable size of gland etc complete all as specified and directed.
Note :- Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
100
-
-
Supply and fixing of three core copper flexible cable , PVC insulated sheathed heavy duty in size 1.5 Sqmm drawn through in steel tubular pole from control box to fittigs for making inter connection complete with all site work and directed. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
30
-
-
Supply and laying galvainesd steel tubing light grade 40 mm dia of bore fixed with pole/ surface of wall / laid in trench etc as site using 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc all as directed. Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
4
-
-
S&F in replacement to shock proof, fire retardant rust proof, out door pole kiosk box of size 295 x195 x100 MM made out of one piece Engineer plastic moulding of siemens grey colour with in built 4 aluminium strip of 60 Amp rating fitted on DMC unbrakable insulator with MCB SPN 40 Amp including fixing arrangement as clamps made out by GI strip in size 32 x 6 MM and nut bolts washer with painting in two coat syenthic enamel paint over one coat of red oxide primer etc all complete all as specified and directed. Make : Model- GSJB-3020 of Sintex or equivelent as specified in List of makes.
3
-
-
Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for wall foundation etc or for manholes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil.
16.27
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers each not exceeding 25 cm thick in soft/loose soil.
7.27
-
-
Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point.
9
-
-
M&L for Sand cushioning in trenches with clean dry unsheathed gently punning around cable for protection complete.
Note : Only punned thickness shall be measured for payment
6.08
-
-
M&L for brick, old sub class 'B' well burnt, laid dry flat in trenches for protection of cable over LT cable, complete all as specified and directed.
0.6
-
-
M&L for providing PCC 1:4:8, type D2 ( using 40 mm graded crushed stone aggregate) in foundation concrete encasing the pole upto GL.
0.24
-
-
M&L for PCC 1:3:6, type C-2 ( using 40 mm graded stone aggregate ) as in mass concrete, foundation of Pole.
Note :- Volume of pole shall deducted for payment purpose.
1.2
-
-
M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate in coping/ pedastal to poles including weathering, slightly rounded or chamfered angles including necessary form work complete and finishing the exposed surface even smooth using extra cement.
Note :- Volume of pole shall deducted for payment purpose.
0.18
-
-
Supply, installation, testing and commissioning of floor/ surface mounting addressable microprocessor fire alarm control main control with BS EN 54 and indicating panel sounder circuits complete with LC Display with back light illumination autodialler and push buttion to acknowledge alarm, testing and reset suitable for operationon 230 Volt single phase 50 HZs Ac supply 24 V DC supply with suitable capacity charger maintenance free hutteries and battery charger including paiting labeling earthing etc compatable with detector for communication to detectors and response indicators together with mimic diagram made on Auto CAD and pasted on acrylic sheet with data logging facility and 2 x 16 character LCD, conforming to IS:2189 and BS EN 54 of capacity from 99 detector and 99 module devices upto 200 detector single loop 6*4 character 2 sounder circuits PTR requires network card and modules (Per each loop) with PA based evacuation system with its own stand by power backup supply with batteries, battery charger incl an auto dialling facility and potential NO & NC contacts and a 80 watts PA amplifier and capacity not less than 8 zones etc incl making all connection and fixing accessories complete all as specified and directed.
Note :- Quoted rate shall be included cost of batteries (in qty, rating capacity) with suitable raiting charger and GI angle factory made made battery stand as per origional maufacture. Make:- Morley Model MOF 714001115 or equivelent in Ravel Safeway/ Suraksha
1
-
-
Supply, installation, testing and commissioning to addressable type certified to EN 54 part A 1 58 degree addressable type, microprocessor based, programable inteligent type,blue light optical thermal heat detector with base photo electric with rate of rise cum fixed temperature as per IS; 2175 distributed memory having resident memory and resident decision alongthm detector with in built isolator complete including necessary connection all as specified and directed.Make:- Morley Model MOFHMRHSE
21
-
-
Supply, installation, testing and commissioning to addressable type certified to EN 45 addressable type, microprocessor based, programable inteligent type,blue low profile light optical smoke cum thermal detector (100% substitute of ionisation detector) with base photo electric with self built imtelligence as per IS; 11360 distributed memory having resident memory and resident decision alongthm detector with in built isolator complete including necessary connection all as specified and directed. Make ;- Morley Model MOFHMPSES2 or equivelent in Ravel Safeway/ Suraksha
21
-
-
Supply, installation, testing and commissioning to addressable imtelligence having inbuilt microprocessor , memory and decision alogrithm twin angle optical smoke with both forward and backward light scattering mechanism cum thermal multicriteria detector with complete assembly with base unit for detector having in built isolator including necessary connection all as specified and directed. Make ;- Morley Model MOFMIB501APIV or equivelent in Ravel Safeway/ Suraksha
21
-
-
Supply and fix addressable type red add manual call with flush mounting glass box resettable type suitable to continuous monitoring including making connection etc point break glass type compatible with main fire alarm control board microprocessor based as per IS-2189 and including chain hammer facility and blinking facility complete all as specified and directed. Make ;- Morley Model MOFH MMC PGL ASS or equivelent in Ravel Safeway/ Suraksha
2
-
-
Supply, installation, testing and commissioning of beam master detector with standard transmitter and receiver with power supply unit in required modules suitable for continious monitoring ISI marked certified to pertain EN including making all connections etc all as specification and directed.
1
-
-
Supply, installation, testing and commissioning of addressable wall mounting intelligent electronic sounder cum strobe ISI marked conformimng to perticular IS and EN incl making all connection complete.
1
-
-
Supply, installation, testing and commissioning addressable remote response indicators having flashing green LED and Red LED for indication of fire and continous monitoring including necessary connection to pin point location of fire complete all as specified and directed.
1
-
-
Supply, installation, testing and commissioning of addressable electronic speaker cum Hooter with range of 25-30 meter with output not less than 4 Watt including necessary connection complete all as specified and directed.
1
-
-
M&L Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of size not less than 20mm dia including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete.
Note:- (a) Two runs of 4 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment.
(b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
120
-
-
M&L Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 1.5sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of size not less than 20mm dia including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 1.5 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete.
Note:- (a) Two runs of 1.5 sqmm cable and one run of 1.5 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment.
(b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Make :- As specified in Appendix 'B' (list of Makes) to Particular specifications.
350
-
-
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements