Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date20 Nov 2024
Closing Date11 Dec 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fixing for 20 mm bore galvanised iron tube, medium grade, ISI marked with all fittings (such as bends, elbows, tees, short pieces of medium grade, connectors, black nuts, caps, plugs and unions etc.) laid in trenches/ floor/ ducts including cutting pipes, screwing and for making forged ends on piping as required complete all as specified and as directed by Engineer-in-charge.

150

-

-

... More
Supply and fixing for 20 mm dia gate or globe valve conforming to IS : 9338 complete all as specified.

20

-

-

... More
Supply and fixing for bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc.), Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed Engr-in-Charge.

100

-

-

... More
M&L for construction of brick masonry valve pit of size 1050 mm X 1050 mm X 1050 mm (outer dimensions) with excavation & earthwork in any type of soil, brick work of fly ash old size bricks built in cement mortar 1:4, PCC 1:2:4 type B-1 as in foundation concrete, bed/floors, coping and 10 mm thick rendering in cement mortar 1:4 on internal and exposed external surfaces, external plaster shall be upto 15 cm below GL and mixed with water proofing compound @ 2% by weight of cement with and including 40 mm X 40 mm X 6 mm mild steel angle iron frame, 3.15 mm thick mild steel sheet cover with appropriate size lifting handles and locking arrangement and 01 No 50 mm size 4 levers lock with keys in duplicate including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified.

1

-

-

... More
Supply and Install Booster pump up to 30 meter head discharge 450 LPM complete all as specified.

1

-

-

... More
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in soft/loose soil for cables, pipe, RCC poles/stays and struts etc and forming bottom surfaces to reqd slop/gradient complete all specified and directed.

527

-

-

... More
Returning filling in, including spreading leveling watering and well ramming in layers not exc 25 cm in soil complete all as specified.

105

-

-

... More
Removing excavated surplus materials (solls) to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified.

422

-

-

... More
M&L for making stand post made of 20 mm GI pipe meduim grade of height 0.60 mtr including 15 mm dia bib tap cast copper alloy as in garden complete all as specified.

60

-

-

... More
S&F for monoblock pump set suitable for 415 volt, 3 phase system having capacity 25 HP complete all as specified.

2

-

-

... More
M&L for cleaning of existing under ground GI pipe line with suitable pressure complete all as specified and directed .

85

-

-

... More
S&F for star delta starter fully automatic suitable for 415 AC for 25 HP monoblock pump complete all as specified. Make: L&T/ Havells/ Legrand

2

-

-

... More
S&F for brass garden faucet bib tap forged with 15 mm bore slim hose nozzle durable and easy to use complete all as specified.

2

-

-

... More
S&F for XLPE LT cable heavy duty 1100 volts grade, ISI marked insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor of size 120 Sqmm 3.5 core including commissioning and testing in trenches/ducts/passing through pipe / fixing on poles including taking out existing cable complete all as specified and directed. (Note: (i) Necessary test results like continuity test, megger tests shall be submitted to Engineer-in-Charge before the cable is laid. (ii) Excavation & earth work will be measured and paid separately).

130

-

-

... More
All as per Item No. 17 here in before but cable of size 95 Sqmm 3.5 core.

160

-

-

... More
All as per Item No. 17 here in before but cable of size 70 Sqmm 3.5 core.

120

-

-

... More
All as per Item No. 17 here in before but cable of size 50 Sqmm 3.5 core.

80

-

-

... More
All as per Item No. 17 here in before but cable of size 35 Sqmm 3.5 core.

170

-

-

... More
All as per Item No. 17 here in before but cable of size 25 Sqmm 4 core.

150

-

-

... More
M&L in replacement of LT cable straight through jointing kit heat shrinkable type suitable for XLPE/ PVC insulated cable of size 3.5/4 Core 10 Sqmm to 16 Sqmm complete including testing the cable joint for healthiness, cutting & removing unserviceable joint, preparation of both ends of cable to be joined with necessary stretching, aligning, making joint complete all as specified and directed

3

-

-

... More
All as per Item No 23 here in before but straight through of size 25 Sqmm to 50 Sqmm 3.5 core complete.

2

-

-

... More
All as per Item No 23 here in before but straight through of size 70 Sqmm to 150 Sqmm 3.5 core complete.

1

-

-

... More
M&L for horizontal boring under hard standing/ pavements or roads manually using suitable auger for insertion of GI pipes up to 100 mm bore and making good the disturbed surface complete all as specified and as directed. (Note: GI pipe will be measured and paid separately).

46

-

-

... More
S&F for 50 mm bore galvanised iron tubing, light grade with all fittings and laid in trenches or inserting in horizontal boring including dismantling of existing pipe complete all as specified.

12

-

-

... More
S&F for 80 mm bore galvanised iron tubing, light grade with all fittings and laid in trenches or inserting in horizontal boring including dismantling of existing pipe complete all as specified.

18

-

-

... More
S&F for 100 mm bore galvanised iron tubing, light grade with all fittings and laid in trenches or inserting in horizontal boring including dismantling of existing pipe complete all as specified.

12

-

-

... More
S&F in replacement of MCCB, 4 Pole, 250 Amp, 25 KA, 415 Volt with adjustable magnetic setting with 02 Nos spreader links for both incoming side and out going side complete all as specified.

2

-

-

... More
S&F in replacement of MCCB, 4 Pole, 200 Amp, 25 KA, 415 Volt with adjustable magnetic setting with 02 Nos spreader links for both incoming side and out going side complete all as specified.

2

-

-

... More
Supply, installation, commissioning and testing of 75 KVA capacity Servo controlled voltage stabilizer confirming to BIS-9815 (Part-1) (1994), three phase, 50 Hz, naturally oil cooled, indoor type, unbalanced type, copper wound, metallic body duly powder coated with lifting hooks two Nos. with digital display type, relay free (microprocessor based) smooth and silent operation with and including first filling of transformer oil up to required level comprising of the following specifications and characteristics complete all as specified and directed: - (a) Input voltage range- 300 to 480 Volts, 3 Phase, 50 Hz. (b) Output voltage stabilized at- 380 Volts + 10%, 3 Phase, 50 Hz. (c) Operating frequency- 47 to 53 Hz. (d) Operating Temperature- 0 to 50 degree centigrade. (e) No. of Phases- 03. (f) Speed of correction- 8 to 6 volts per Second for single phase and 13 volts per second Phase to Phase. (g) Efficiency- Greater than 97%. (h) Type of voltage / load- Unbalanced 4 wire (j) Mode of operation- Fully automatic. (k) Displaying type- Digital voltmeter, digital ammeter, digital input frequency meter. (m) Protective- Over voltage, under voltage, over load, High / low voltage cut off, single phase preventer and phase reversal protection with by pass arrangement switch 4 Pole of suitable capacity, spike suppressor, alarm system. (n) MCCB for INPUT and OUTPUT of suitable capacity as per KVA rating. (Note: - Design, drawings, Technical specifications submitted by the contractor shall be approved by the Garrison Engineer).

1

-

-

... More
Supplying, installation, commissioning and testing in replacement of LT busbar panel, outdoor type, overall size not less than 1800 mm x 1200 mm height (with canopy and base channel) x 450 mm depth, MS channel base frame mounted (to be mounted on 3 side cover brick pedesatal of height 300mm above ground level) conforming to IS/IEC-61439-1 & 2 with rated fault 50 kA / 1 sec with internal wiring with internal arc containment, suitable for 415 volts 3 phase 4 wire system 50 Hz AC supply and having 4 Nos aluminium bus bar of rating 315 amps. The panel shall be dust proof, vermin proof (IP 54) and powder coated and made out of 3.0mm thick CRCA sheet self moulded type and (50 x 50)mm x 6mm angle iron frame front and rear opening with double shutter and locking arrangement with 50mm size lock with and including grouting of panel with necessary PCC (1:2:4) type B1 (using 20mm graded stone aggregates) complete all as specified and comprising of following accessories :- (a) Incoming : MCCB 320 Amp, 4 Pole, breaking capacity 25 kA with adjustable thermal setting - 01 No. (b) Outgoing (i) Onload change over switch 415 volt in sheet metal enclosure, 4 pole of capacity 160 amp - 02 Nos (ii) MCCB 4 pole 125 Amp, 25 kA breaking capacity with adjustable thermal setting - 02 Nos (iii) MCCB 4 pole 63 Amp, 25 kA breaking capacity with adjustable thermal setting - 02 Nos. (iv) MCB SP MCB 6 Amp 10 kA (for control wiring) - 01 No. (v) Indicating LED lamp (RYB)- 01 set of three (vi) Digital volt meter 0-500 volt (96mm x 96mm)-01 No (vii) Digital Amp meter 0-500 Amp (96mm x 96mm)-01 No (viii) CT having ration 300/5 tape wound BPL rated burden 5 VA - 03 Nos. (Make of MCCB :Siemens/ Schneider/ L&T)

1

-

-

... More
Design, supply, erection, testing and commissioning in replacement of outdoor type LT Panel of overall size not less than 1800 mm (W) X1200 mm (Ht) (Without Canopy & Base channel) x 450 mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 450 mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 600 amps insulated , Provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables the LT panel shall be duly fabricated in a approved fabrication house who posseses type test certificate from CPRI for similar type of LT panel and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The LT panel shall be duly fabricated in a approved / certified factory / fabrication house who possesses type test certificate from CPRI for similar type of LT panel and having modern fabrication and testing facility which includes at least seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL-7032 (SIEMENS GRAY). The LT Panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection shall not be less than IP-54 and general construction conforming to IS-13947. The LT Panel shall be made out of 3.15 mm thick CRCA mild steel sheet and 3.15 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with double layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The LT Panel shall be comprising of the following: - PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables through and including cable gland ade of Brass. CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges INCOMING :- MCCB, 4 Pole (with panel mounted rotary handle) having breaking capacity of 36 KA, fixed magnetic and fixed thermal setting (100% - 80%) of rating 320 Ampere- 01 No. OUTGOING :- (i) MCCB, 4 pole, 200 Amps having breaking capacity 25 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz - 01 No. . (ii) MCCB 4 pole 100 Amps having breaking capacity 25 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz - 03 Nos. (iii) MCCB 4 pole, 63 Amps having breaking capacity 16 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz - 02 Nos. MISCELLANEOUS ITEMS :- (a) MCB 6 Amp, SP, 10 KA (For Control Wiring) - 01 No. INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED - 01 set of 3 lamps (RED,YELLOW & BLUE) Digital Multifunction meter - 01 No. C.T having Ratio 300/5, resin cast, - 03Nos.

2

-

-

... More
S&F in replacement of on Load changeover switch 415 Volt, 4 pole, 250 Amps capacity with sheet steel enclosure for mounting on wall/floor complete all as specified and as directed. [Make: Legrand/ L&T/ ABB/ Schneider/Indo asian]

1

-

-

... More
M&L in replacement of earthing complete with galvanized steel earth plate electrode 60 cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth strip of 32 mm X 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected from earth plate electrode to main switch board/ earthing test point including watering arrangement with PCC 1:3:6 type C-1 chamber, MS funnel, wire gauge, 50 mm thick precast RCC cover in type B-1 including necessary excavation in any type of soil, returning filling in, removal of surplus soil to a distance not exc 50 mtr, charcoal and salt complete all as shown in electrical plate No.03 of SSR Part-I and connected to earthing test point all as specified and testing on completion all as specified.

6

-

-

... More
M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete all as specified.

1.2

-

-

... More
M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping of pole including form work all as specified

0.5

-

-

... More
M&L for dry sand cushioning to underground cables with 8 cm thick before laying of cables and 15 cm thick after laying and stretching of cable complete all as specified. (Note : Only punned thickness i.e. 18 cm shall be measured and paid).

40

-

-

... More
M & L for sub class 'B' brick for covering to under ground cable laid flat transversally width equal to the lenth of the cable complete all as specified.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.