Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical Generators And Transformers
Eprocure
Opening Date28 Dec 2024
Closing Date21 Jan 2025
Tender Amount₹ 48,00,000
Costs
EMD
₹ 96,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair/maintenance Of Transformer Including Allied Works At North/south/bhagat
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_690724_1Tender No
94195/MRT/2024-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/MAINTENANCE OF TRANSFORMER INCLUDING ALLIED WORKS AT NORTH/SOUTH/BHAGAT LINE/DABATHWA AREA UNDER AGE E/M (ES) AT GE (U) E/M MEERUT CANTT
BOQ Items
... More
700 to 2000 KVA transformer
2
-
-
... More
5000 to 10000 KVA Transformer
1
-
-
... More
NOTE :- (i) The contractor shall produce test certificate as per IS-2026 alongwith high voltage test from the firms after repair.
-
-
-
... More
(ii) To accertain the fault of transformer at installed location, the transformer will be tested with HT 10KV magger, multimeter in the presence of AGE E/M/JE E/M. All T&P required like HT magger 10KV, multimeter and cables will be arrenged by contractor.
-
-
-
... More
(iii) All the transformer shall be opened in presence of Engr- in- Charge/ his rep veryfy the various repairs/replacement involved and the transformer shall be assembled in the presence of Engr- in- Charge/his rep after necessary repairs/replacement.
-
-
-
... More
(iv) All the transformer shall be tested in the factory in the presence of Engr- in- Charge/ his rep, as per ser note No (i) above and also in addition the transformer where specified to be installed and commissioned on the 2/4 pole structure, platform and also shall be tested by the contractor in the presence of Engr- in- Charge.
-
-
-
... More
(v) All the testing arrangement shall be provided by the contractor without any extra payment.
-
-
-
... More
(vi) The contractor shall also furnished a guarantee certificate himself for rectification of the defects. If any noticed defect during liability period for 01 year from the certified date of completion.
-
-
-
... More
(vii) The above shall however does not absolve the responsibility of the contractor for rectification of any defect, if any noticed during guarantee period of 01 year as per condition 46 of IAFW-2249 and the contractor shall be solely responsible for entire completion of work and for rectification of the defect/replacement of items/parts and required pointed out by the GE during defect liability period of 01 year. Payment only for dehydration of the transformer oil and painting of the transformers replacement of certain items considered separately here- in- after shall only be made for separately all other minor repair/replacement as required and ordered by the Engr- in- Charge for entire completion of work shall be deemed to be included in the unit rate of the above items.
-
-
-
... More
(viii) The contractor shall also clear the breathers. The unit rate quoted by the contractor shall included this aspect also.
-
-
-
... More
(ix) Contractor shall provide all arrangement for carefully handling/conveyance of/ transportation of equipment by means of crane/chain pully/recovery van and vehicles as per requirements and directed by Enge- in- Charge.
-
-
-
... More
(x) Transformer oil tank rubberised 6.0mm thick gasket sheet pasted using gasket cement, oil level gauge, drain valve, painting inner side tank by zinc chromate paint and outer side by approved paint include in this item rate.
-
-
-
... More
(xi) The rate quoted by contractor shall include all these aspect from (i) to (x) while quoting his tender that quoted rate also include the provision of providing electric connection to exisiting system.
-
-
-
... More
M&L for shifting of transformer of capacity 63 to 2000KVA from existing PCC platform/ four pole/two pole structure/MES store yard and fixing on platform/four pole/two pole structure at other location by suitable capacity of crane including necessary connection on HT & LT side and testing on completion complete as directed by Enge-in-Charge.
18
-
-
... More
M&L for shifting of transformer of capacity 5000 to 10000KVA from existing PCC platform/ four pole/two pole structure/MES store yard and fixing on platform/four pole/two pole structure at other location by suitable capacity of crane including necessary connection on HT & LT side and testing on completion complete as directed by Enge-in-Charge.
1
-
-
... More
M&L Segregation of HT leg coil from transformer and making new HT leg coil with insulating copper wire of required gauge craft paper cotton tape HT/LT insulation as per as per IS specification of old transformer including ovening & heating after marking of coil as required of following capacity.
-
-
-
... More
63 to 160 KVA.
381
-
-
... More
200 to 250 KVA.
472
-
-
... More
300 to 400 KVA.
467
-
-
... More
500 to 630 KVA.
568
-
-
... More
700 to 1000 KVA.
378
-
-
... More
1500 to 2000 KVA
450
-
-
... More
M&L Segregation of LT leg coil from transformer and making new LT leg coil with insulating copper wire of required gauge craft paper cotton tape HT/LT insulation as per as per IS specification of old transformer including ovening & heating after marking of coil as required of following capacity :-
-
-
-
... More
63 to 160 KVA.
306
-
-
... More
200 to 250 KVA.
384
-
-
... More
300 to 400 KVA.
375
-
-
... More
500 to 630 KVA.
454
-
-
... More
700 to 1000 KVA.
315
-
-
... More
1500 to 2000 KVA
400
-
-
... More
M&L Disconnecting HT & LT connection of any type & capacity transformer. Opening of transformer cover at site for carrying out testing/repair such as repalcement of internal/external damage parts and re-assembling after carrying out required repair in the transformers and testing complete all as directed by Engr-in-Charge. NOTE :- Parts replaced of transformer shall be measured and paid separetly under respective items.
18
-
-
... More
Supply only HT bushing complete with metal part, gasket set, nut, bolts and washers for any type of transformer at site /in workshop all as directed, for the following capacity :-
-
-
-
... More
63 to 250 KVA.
35
-
-
... More
300 to 400 KVA.
30
-
-
... More
500 to 630 KVA.
18
-
-
... More
1000 to 5000 KVA.
6
-
-
... More
Supply only LT bushing complete with metal part, gasket set, nut, bolts and washers for any type of transformer at site /in workshop all as directed, for the following capacity :-
-
-
-
... More
63 to 250 KVA.
35
-
-
... More
300 to 400 KVA.
35
-
-
... More
500 to 630 KVA.
24
-
-
... More
1000 to 5000 KVA.
8
-
-
... More
Supply only HT bushing rod (brass) complete with nuts, bolts and washers for any type of transformer at site /in workshop all as directed, for the following capacity :-
-
-
-
... More
63 to 250 KVA.
15
-
-
... More
300 to 400 KVA.
10
-
-
... More
500 to 630 KVA.
10
-
-
... More
1000 to 5000 KVA.
8
-
-
... More
Supply only LT bushing rod (brass) complete with nuts, bolts and washers for any type of transformer at site /in workshop all as directed, for the following capacity :-
-
-
-
... More
63 to 250 KVA.
15
-
-
... More
300 to 400 KVA.
12
-
-
... More
500 to 630 KVA.
10
-
-
... More
1000 to 5000 KVA.
8
-
-
... More
Supply only tap changer switch complete with rod and gasket for any type of transformer at site/in workshop all as directed for the following capacity :-
-
-
-
... More
63 to 250 KVA.
10
-
-
... More
300 to 500 KVA.
9
-
-
... More
630 to 2000 KVA.
3
-
-
... More
Supply only oil drain valve for any type of transformer at site/in workshop all as directed for the following capacity :-
-
-
-
... More
63 to 250 KVA.
10
-
-
... More
300 to 500 KVA.
10
-
-
... More
630 to 5000 KVA.
5
-
-
... More
Supply & replacement De-hydrating breather with first fill of dehydrating agent (silica gel).
-
-
-
... More
63 to 250 KVA.
14
-
-
... More
300 to 500 KVA.
10
-
-
... More
630 to 5000 KVA.
6
-
-
... More
S&F One 100mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device.
8
-
-
... More
Scraping and removing of worn out transformer oil tank gasket and supply& fixing new rubberized gasket sheet in the tank top cover, 6.0 mm thick and pasted using gasket cement, including fixing the top cover with conservator in the transformer of following capacities:-.
-
-
-
... More
63 to 250 KVA.
14
-
-
... More
300 to 400 KVA.
15
-
-
... More
500 to 630 KVA.
8
-
-
... More
1000 to 2000 KVA.
1
-
-
... More
Scrapping and removing of worn out gasket from LT and HT bushing and supply & fixing of rubberized gasket duly cut as per the size of bushing and pasted with gasket cement including cleaning and removing of carbon from HT/LT bushing, replacement of rubber oil seals, assembling the LT/HT bushing and fixing connection with terminals as directed for transformer of the following capacity:-
-
-
-
... More
63 to 200 KVA.
10
-
-
... More
250 to 315 KVA.
9
-
-
... More
400 to 500 KVA.
6
-
-
... More
630 to 2000 KVA.
3
-
-
... More
M&L for replacement of fresh silica gel complete all as specified and directed.
100
-
-
... More
Replacement of oil level indicator glass for any type/ capacity of transformer complete all as directed .
12
-
-
... More
Repair cooling pipe of transformer of any capacity at site for rectification of any leakage including welding/ Brazing complete all as specified and directed .
5
-
-
... More
M& L for dismantling of transformers indoor/outdoor type complete, opening top cover by unscrewing nuts, bolts, unserviceable HT/LT coil of transformer, gaskets, bushing core tap changer, draining out transformer oil and keep safely for reuse after filtration, cleaning the inner body with caustic soda/detergent and washing to removing sludge etc, painting the inner side tank by Zinc chromate paint and preparing the same for reassembling all as specified and directed by Engineer-in-Charge of following capacity :-
-
-
-
... More
63 to 200 KVA.
14
-
-
... More
250 to 315 KVA.
12
-
-
... More
400 to 500 KVA.
12
-
-
... More
630 to 2000 KVA.
3
-
-
... More
Copper strip of size should be of 12 mm, 20 to 25 cm long on LT side of transformer at site duly drilled holes for transformer studs & LT cable fixed with GI bolts nuts & washers of appropriate size complete all as directed of following capacity of transformers :-
-
-
-
... More
63 to 300 KVA transformer.
20
-
-
... More
315 to 500 KVA transformer.
20
-
-
... More
630 to 2000 KVA transformer.
15
-
-
... More
Supply & Fixing Aluminium lugs / PG clamb for HT bushing of suitable size by means of using crimping tool after removing existing unserviceable lugs for the any type/ capacity of transformers all as directed by Enge-in-Charge.
46
-
-
... More
Supply & Fixing Aluminium lugs / PG Clamb for LT bushing of suitable size by means of using crimping tool after removing existing unserviceable lugs for the following capacity of transformers all as directed by Enge-in-Charge :-
-
-
-
... More
63 to 300 KVA transformer.
20
-
-
... More
315 to 500 KVA transformer.
30
-
-
... More
630 to 2000 KVA transformer.
6
-
-
... More
Supply & Filling of transformer oil in transformer in situ/at site for toping up the level of oil having dielectric strength 60 KV during filling after initial filtration conforming to IS-335. Transformer oil shall be supplied in sealed container complete all as directed by Engr-in-Charge.
-
-
-
... More
63 to 400 KVA.
4500
-
-
... More
400 to 630 KVA.
2800
-
-
... More
700 to 2000 KVA.
1500
-
-
... More
5000 to 10000 KVA.
1600
-
-
... More
Dehydration/ filtration of transformer oil of existing transformer installed at site with portable plant to improve the dielectric strength 60 KV during filling after initial filtration including testing of dielectric strength after dihydration at site.
8000
-
-
... More
NOTE :- (i) All arrengement of DG set of suitable capacity of electric supply for running of dehydration plant, T&P and other items required will be arranged by contractor and deem to be included in the cost of dehydration/filtration and nothing extra on this account will be admissiable.Any damage after filtration shall be solely responsible of Contractor & same shall be repaired without any additional cost.
-
-
-
... More
Painting of transformer indoor/ outdoor on plinth/ pole/ in workshop with one coat of synthetic enamel paint with compressor spray Gun after removing all dust, Rust, paint shall confirmed to IS-2032 as directed by EIC for following capacity of transformer ;-
-
-
-
... More
63 to 250 KVA transformer.
15
-
-
... More
300 to 500 KVA transformer.
12
-
-
... More
630 to 2000 KVA transformer.
5
-
-
... More
5000 KVA transformer.
1
-
-
... More
10000 KVA transformer.
2
-
-
... More
Testing of power transformers of Capacity 5 MVA to 10 MVA installed at MRS with Carried out the following test as the desire satisfaction of Engineer in-charge/GE :-
(a) Voltage ratio test (b) Magnetization Current Test
(c) Voltage balancing Test
(d) Short Circuit Test
(e) Oil testing having Dielectric strength upto 60 KV
NOTE :- (i) The contractor shall produce test certificate against above tests from ser no (a) to (e) from the certified firm.
6
-
-
... More
Taking out existing unsv surge arrester any type and Supply, install, testing and commissioning single pole lighting arrestor rated 33 KV for system highest voltage of 36 KV, of gapless metal oxide type - polymer housing, discharge current 10 KA, class I, basic insulation level 170KV, complete with all accessories and including necessary connection all as specified and as per IS : 3070 Part-III and IEC 60099-4 complete all as specified and as directed by Engr-in-Charge. (Make : CROMPTON GREAVES/ALSTOM/OBLUM/ELPRO)
2
-
-
... More
M&L for disconnecting of transformer from power mains and lifting from platform and fix aside of platform for rapairing of damage platform and after fixing at pite same connection for fed to electric supply to the connected area complete After carriedout repair work transformer fixed as per existing complete all as specified and directed.
15
-
-
... More
Supply & Fixing Copper fuse wire of required rating or size for 2/4 Pole structure DO fuses are avilable with proper arrangement all as directed by Enge-in-Charge.
10
-
-
... More
Finding out the cable fault of any size and any capacity of cable from LT 1100 Volt grade to 33000 KV with the help of cable fault loacator and with Necessary disconnection of cable from two ends and connection after repairs and having the following items with electrician at site up to length of 0.5 KM cable complete all as specified and directed by Engr-in-Charge:-
(a) Surge Generator with accessories-01 Nos
(b) Head Phone- 01 Nos (c) Pin Point set T-505 with accessories- 01 Nos (d) Earthing cable with clamp-01 Set (f) Cable fault locator T-905 with accessories -01 Nos (g) TC-808 with accessories -01 Nos (h) Soldering Iron-01 Nos (j) Plier- 01 Nos (k) Soldering paste -01 Nos (l) Capacitor Unit -1 Nos (m) Capacitor connecting cables-01 Nos (n) Power cable-01 Nos (o) Nose plier -01 Nos (p) Card for SSG -1100-01 Nos.
Note:- Transportation charge for shifting cable fault locater will deem to be including in above send job and nothing extra on this account will be admissible.
5
-
-
... More
M&L, Scraping, including cleaning and preparation of old surfeces of 2 pole structre with any type size of pole including channels /nuts/ bolts/ GOD/ anti climbing device complete and painting with two coat for aluminium paint after preparation of the steel surfaces of pole and steel structure of pole and steel structre fixed along pole and then applied painting 05 nos band /strips with fluorescent , Black/ Red/ White/ Green and Black synthetic enamel paint ( 30 cm wide each) at a distance of 30 cm from plinth block. Height of the strap shall be 30 cm and number of strap shall be 05 Nos writing pole no of letter size 2” by sign with white paint as directed by Engineer-in-Charge.
2
-
-
... More
M&L, Scraping, including cleaning and preparation of old surfeces of 4 pole structre with any type size of pole including channels /nuts/ bolts/ GOD/ anti climbing device complete and painting with two coat for aluminium paint after preparation of the steel surfaces of pole and steel structure of pole and steel structre fixed along pole and then applied painting 05 nos band /strips with fluorescent , Black/ Red/ White/ Green and Black synthetic enamel paint ( 30 cm wide each) at a distance of 30 cm from plinth block. Height of the strap shall be 30 cm and number of strap shall be 05 Nos writing pole no of letter size 2” by sign with white paint as directed by Engineer-in-Charge.
3
-
-
... More
M&L, Surface Dressing/Cleaning of surrounding area of 2/4 pole/transformer pilinth/ TR structure including removing of any type and size of tree branches / plants and bushes etc with Triming of tree branches (tree prunning) up to 3 mtr surounding of 2/4 pole sructre s/stn boundary to clear including removing the cut branches from site and depositing at places all as directed by Engr-in-Charge.
65000
-
-
... More
M&L for cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) for plat form of transformer including necessary form work and demolitions of existing damaged part of concrete.
5
-
-
... More
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) for coping / pedestal of poles including necessary form work, fair finishing to exposed surfaces including demolation of existing damaged part of concrete
2
-
-
... More
M&L for taking down old damage plaster arround the transformer pilinth and dameged platform Preparing the surfaces, Curing of pointed surface. , Cleaning stains and dripping mortars from floors and walls, etc and Rendering 10mm thick 1:4 cement plasters on fair faces of brickwork or concrete surfaces complete all as specifed
40
-
-
... More
Taking out unsv channels and Supply and fixing pre-fabricated MS structural steel (IS marked) work consisting of channels / angles / other sections etc of various sizes and shape, cut / weld / drilled holes etc hot / cold in position for cross arms with FI clamps (full, half D and earth clamp etc) incl necessary MS bolts, nuts etc and painting, all as directed and specified.
1.5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%