Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Dec 2024
Closing Date11 Jan 2025
Tender Amount₹ 44,36,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item no 01.01 but for 80/100 mm bore

12

-

-

... More
Supply only GI Socket size upto 25 mm bore 'Medium' grade ISI Marked.

25

-

-

... More
All as per item no 01.04 above but for 32 to 50 mm bore

14

-

-

... More
All as per item no 01.04 above but for 80/100 mm bore

12

-

-

... More
Supply only GI Union size upto to 25 mm bore 'Medium' grade ISI Marked.

35

-

-

... More
All as per item no 01.07 above but for 32 to 50 mm bore

24

-

-

... More
All as per item no 01.07 above but for 80/100 mm bore

8

-

-

... More
Supply only GI Nipple upto 40mm bore 'Medium' grade in different lengths upto 300 mm all as per requirement, both end screwed.

45

-

-

... More
Supply only GI Socket Reducing socket upto 40 mm bore 'Medium grade' of any size & type ISI marked.

70

-

-

... More
Supply only GI Socket Reducing socket 50/80 mm bore 'Medium grade' of any size & type ISI marked.

15

-

-

... More
Supply only GI Tee upto 25 mm bore 'Medium grade' of any size & type ISI marked.

55

-

-

... More
Supply only GI Tee 32/40 mm bore 'Medium grade' of any size & type ISI marked.

30

-

-

... More
Supply only GI Tee 50 mm /80 mm bore 'Medium grade' of any size & type ISI marked.

10

-

-

... More
Supply only GI Tee 100 mm/150mm bore 'Medium grade' of any size & Type ISI marked.

5

-

-

... More
Excvation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr deep for pipe line & other works like LT/HT cable etc in soft/loose soil, getting out and levelling of bottom surface to required complete all as specified and as directed.

114

-

-

... More
Returning filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick all as specified and as directed.

94

-

-

... More
Removing excavated material from site to a distance not exc 50 m away and depositing where directed not exc 1.5 meters above the starting point all as directed.

20

-

-

... More
Supply and laying 100mm dia bore Cast iron pipes with flanged ends, centrifugally cast, class A, in any length laid in trenches including taking out old unserviceable complete all as specified and directed

45

-

-

... More
All as per item ser No 5.00 above but 80mm bore.

155

-

-

... More
M&L in repair for cast iron Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross(all sockets or socket and spigot) collars, caps and plugs,up to 150 mm bore, for spigot socketed pipes confirming to IS: 1538-1993 complete all as specified and directed.

35

-

-

... More
Supply & fixing, CI sluice valves of 80mm bore in existing valve pit chamber/any other position class PN 1.6 ISI mark flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with including nut and bolts washers and rubber gasket, taking down old unsv sluice valve complete all as specified and as directed.

10

-

-

... More
All as per item ser No 8.00 above but for 100mm bore.

4

-

-

... More
M&L for taking out old unserviceable burnt winding of centrifugal motor 7.5 to 15 HP capacity, 3 phase, 415 volts, 50 Hz, AC supply after disconnecting all electrical connections and rewinding by using super enamelled copper conductor of existing gauge and size by maintaining existing turn ratio, applying insulation varnish and drying up to specified period to achieve desired insulation value including reassembling of motor after rewinding and testing and connecting all electrical connection using suitable size of lugs complete all as specified and directed.

8

-

-

... More
Transporting of Submersible/ Centrifugal Pump Set any capacity from Pump House/ E&M store yard at ADRDE/Vigyan Vihar/Raksha Vihar to nearest workshop for repairing including carefully loading/ unloading and back to old location etc complete all as specified and directed

12

-

-

... More
Lifting out/ taking up carefully submersible Pump Set and motor from bore well after disconnecting electrical and pipe line conections with the help of chain pully block with tripod including column pipe and submersible cable from 240 feet approx depth, disconnecting pump and motor from coupling and keeping aside for testing / checking submersible pump set and other connected acessories for servicibility complete all as specified and directed Note : T&P required shall be provided by the contractor and rates for the same are deemed to be included in quoted rates.

4

-

-

... More
Taking out unserviceable impeller and casing from the pump upto 15HP and replacing with new impeller and casing of same size / type as per the existing one complete all as specified and directed.

5

-

-

... More
Taking out old unserviceable burnt winding of submersible motor 10/12.5/15 HP, 3 phase 415 volts, 2900 RPM, 50 Hz AC supply and rewinding using copper super enamelled conductor PVC insulated of existing gauge and size by maintaining existing turn ratio and reassembling of submersible motor after rewinding by replacing burn out parts complete all as specified and directed. Note : (i) Spare parts require to replace (Neck ring,Shaft sleeve,coupling key,impeller key, water seal,distance sleaves,rotor shaft etc)shall also be included in quoted rate. (ii) Lifting and lowering shall be measured & paid under item No 12 &16 of BOQ respectively.

4

-

-

... More
Taking out old unserviceable bearing of submersible/centrifugal motor of 12.5 HP capacity, 3 phase, 415 volts, 50 Hz, AC supply after dismantelling and replace with new moter of exsisting size & type including reassembling of motor after the replacement, testing and connecting all electrical connection complete all as specified and directed.

4

-

-

... More
Labour only for reassembling of submersible/centrifugal pump after repairing and by replacing burnt out parts complete all as specified and directed Note : Spare parts required to be replaced if any shall be measured & paid separately as supply only.

12

-

-

... More
Lowering down, submersible Pump Set and motor by deploying skilled labour inside bore well, with the help of chain pully block with tripod including column pipe and submersible cable up to approx depth 240', after connecting pump and motor with coupling, and making electrical and pipe line connections etc complete all as specified and directed Note : Lifting up shall be measured & paid under item No 12.00 of BOQ

4

-

-

... More
S&F Submersible cable, PVC insulated, multistranded copper conductor, 1100 volts grade, 3 core flat of size 10 Sqmm including taking out old unserviceable complete all as specified and directed

195

-

-

... More
S&F in repair foot valve 80 mm bore, ISI Marked, Brass body, heavy duty having one end flanged or internal screwed suitable to fix in suction pipe and other side strainer with leather flape and counter weight including all fixing arrengements as new nuts, bolts, washers and gasket including testing complete all as specified and directed.

3

-

-

... More
All as per item ser No 19.00 above but 100mm bore.

2

-

-

... More
S&F in repair of Automatic star delta starter suitable for motor upto 15 HP in sheet metal enclosure, suitable for submersible / centrifugal pump set with relay, contactor, auxilary contactor suitable to run on 440 volts, 50 Hz, AC supply complete all as specified and directed

2

-

-

... More
S&F 100mm dia medium grade galvanised steel water tubes with screwed joints together with and including all GI fittings such as bends, tee, unions, sockets short piece connection, backnuts, caps plugs, union coupling, flanges, socket etc laid in trenches and including earth work and removing old pipeline complete all as specified and as directed. Note:- (i) The rates quoted inclusive of earth work,cutting, jointing and leakage testing of the pipe.

90

-

-

... More
All as per item ser No 22.00 above but 80 mm bore.

267

-

-

... More
All as per item ser No 22.00 above but 50 mm bore.

360

-

-

... More
All as per item ser No 22.00 above but 40mm bore.

115

-

-

... More
All as per item ser No 22.00 above but 25mm bore

70

-

-

... More
All as per item ser No 22.00 above but 20mm bore

55

-

-

... More
S&F of 50 mm bore GI pipe medium grade with all new to fittings and fixed complete on walls and ceilings or laid in floors conncetion lines including removing old pipe line complete all as specified and directed. Note :- (i)leakage testing is deemed to be included in quoted rates. (ii) Cutting chasing and making good the surface shall deemed to included to be included in quoted rates.

60

-

-

... More
All as per item ser No 28.00 above but 40mm bore.

145

-

-

... More
All as per item ser No 28.00 above but 25mm bore.

180

-

-

... More
All as per item ser No 28.00 above but 20mm bore.

165

-

-

... More
All as per item ser No 28.00 above but 15mm bore.

50

-

-

... More
Cutting road / hard standing to a size not exceeding 30cm in width and not exceeding 90 cm in depth for removal/ laying of GI pipe upto 100mm bore including making good so as to match with the existing finishes using PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) 100 mm thick complete all as directed.

130

-

-

... More
Taking down rusted CI (cast iron) sluice valve of 100mm bore and transporting to the nearest workshop for servicing including greasing replacing the gasket, make the valve functional and refixing in the same position complete all as specified and directed.

8

-

-

... More
All as per item ser No 34.00 above but 80mm bore

4

-

-

... More
S&F 50 mm bore Gun metal globe or gate valve with iron wheel head, ISI marked screwed both ends for iron pipes in position including removing old unserviceable valve complete all as specified and directed.

10

-

-

... More
All as per item ser No 36.00 above but 40mm bore

15

-

-

... More
All as per item ser No 36.00 above but 25mm bore

22

-

-

... More
All as per item ser No 36.00 above but 20mm bore

30

-

-

... More
Supply and fix in repair of 150mm PVC raising main pipe line exsisting type including all fittings short piece connection, etc laid in trenches and including earth work and removing old pipeline complete all as specified and as directed. Note:- (i) The rates quoted inclusive of dewatering,cutting, jointing and leakage testing of the pipe.

12

-

-

... More
Supply and fix in repair of 100mm PVC raising main pipe line exsisting type including all fittings short piece connection, etc laid in trenches and including earth work and removing old pipeline complete all as specified and as directed. Note:- (i) The rates quoted inclusive of dewatering,cutting, jointing and leakage testing of the pipe.

15

-

-

... More
S & F uPVC pipe with 50 mm nominal dia ,heavy duty suitable for rating 10 kgf/cm2 laid in trenches including necessary eathwork and removeal of old unserivceable pipe complete all as specified and directed.

57

-

-

... More
S & F for fixing of 50 mm uPVC Ball valve in position complete all as specified and directed

4

-

-

... More
S & F in replacement uPVC pipe with 50 mm nominal dia ,heavy duty suitable for rating 10 kgf/cm2 laid in fixed complete to walls, ceilings or in floors etc., complete all as specified and directed.

70

-

-

... More
M&L for bore well cleaning / washing of tube well by using a compressor up to 250mm bore and upto 150 mtr depth by removing the submersible Pump set 12/ 15 HP capacity, column pipe, power cable with the help of tripod and chain pulley block and remove the dirts sludge, mud, clay, sand, scales from top to bottom level with the help of compressor for smooth functioning of the submersible pump including lowering down the pump and testing the suction of potable water from the borewell complete all as specified and directed

2

-

-

... More
S&F in repair of structural steel work such as angle iron, flat, MS plates etc for fabrication base frame of Centrifugal pump set complete all as specified and directed.

30

-

-

... More
Taking out old unserviceable burnt winding of Monoblock motor upto 5HP capacity, single phase, 240 volts, 50 Hz, AC supply after disconnecting all electrical connections and rewinding by using super enamelled copper conductor of existing gauge and size by maintaining existing turn ratio, applying insulation varnish and drying up to specified period to achieve desired insulation value including reassembling of motor after rewinding and testing and connecting all electrical connection using suitable size of lugs complete all as specified and directed.

1

-

-

... More
S&F cast iron 100 mm bore non return valve swing check single door pattern conforming to IS-5312 heavy duty ISI marked with CI drilled flanged ends internally cast including jointing materials complete such as rubber fibre board insertion packing ring nuts bolts and washers of required size etc including taking out old unserviceable complete all as specified and directed

2

-

-

... More
All as per item ser No 48.00 above but of size 80 mm.

2

-

-

... More
M&L for cleaning RCC underground sumps/over head tank internally including bailing out of water below foot valve level, removing all scale and dirt etc from tanks and mouth of circulating pipes by brushing and washing with bleaching powder and water pressure removing silt outside MD land and applying two coats of white wash to external & top surface and writing down the date of cleaning in the format "Tank Cleaned on DD/MM/YYYY" format letter exc. 12.5 cm but n exc 15 cm in height with synthetic enameled paint including preparation of surface complete all as specified and directed of the following capacities and location :-

-

-

-

... More
Capacity 15000.00 gallon or 68200.00 Ltr OH RCC Tank at ADRDE Complex area Pump House

1

-

-

... More
Capacity 15000.00 gallon or 68200.00 Ltr UG RCC sump at ADRDE Complex area Pump House

1

-

-

... More
Capacity 7000.00 gallon or 31900.00 Ltr UG RCC sump at ADRDE Complex area Pump House - 02,MES office complex-01

3

-

-

... More
Capacity 13200.00 gallon or 50000.00 Ltr UG RCC sump at Raksha Vihar Pump House

1

-

-

... More
Capacity 20000.00 gallon or 90900.00 Ltr OH RCC tank at Vigyan Vihar area Pump House. Note for 50.01 to 50.05(i) Dewatering of overhead tank by drain out pipe. (ii) Mechanized removal of all remaining dirty water by high- capacity pump set. (iii) Removal of sludge by vacuum operated Pump. (iv) Cleaning of walls, ceiling and bottom of tank by high pressure rotary jet 120 bars pressure. (v) Removal of all dirty particles by industrial wet vacuum cleaner leaving the tank 99.9% physically cleaned. (vi) Sterilization of tank by Eco-Friendly biodegradable and highly effective anti bacterial non toxic agent approved by NTC (National Toxicology Center) against all pathogens agent of tank clean. (vii) Sterilization of tank atmosphere by industrial UV radiator leaving the tank complete Sterlite by specialized method (viii) The work will be got executed from the reputed specialized water tank cleaner as approved by GE. (ix) All the sludge materials / fungi removed from the underground sump / semi underground sump and over head tanks will be removed outside defence land from the site. (x) All underground sump / semi underground sump and overhead tanks will cleaned in all respect upto 3 mtr around the water tanks. (xi) T&P required for all the above aspects shall be arranged by the contractor.

1

-

-

... More
M&L for run lead joint of size 100 mm dia bore, cranking and making the joint leak proof including taking out old unserviceable complete all as specified and directed

4

-

-

... More
All as per item ser No 51.00 above but 80 mm bore.

6

-

-

... More
Supply, laying and testing of CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPES (SDR-11) Pipes of 50mm(Outer dia)ISI marked as per IS:15778 tough, rigid , pipe cutting fixing with CPVC solvent cement and testing laid in trenches including removing old unserviceable pipe line complete all as specified and directed. Note :Quoted rate shall include of earthwork and provision of special fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor, Unions, Flange etc.

65

-

-

... More
All as per item Ser No 53.00 above here-in-before but 40 mm dia bore.

40

-

-

... More
All as per item Ser No 53.00 above here-in-before but 25 mm dia bore.

115

-

-

... More
All as per item Ser No 53.00 above here-in-before but 20 mm dia bore.

155

-

-

... More
Supply, laying and testing of CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPES (SDR-11) Pipes of 50mm(Outer dia)ISI marked as per IS:15778 tough, rigid , pipe cutting fixing with CPVC solvent cement and testing laid in floors,wall,ceilings including removing old unserviceable pipe line complete all as specified and directed. Note :(a) Quoted rate shall including of necessary special fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor, Unions, Flange and tank adaptor. (b) The rates include for cutting chases in wall, floors etc and their making good in case of concealed pipe work.

35

-

-

... More
All as per item Ser No 57.00 above here-in-before but 40 mm dia bore.

55

-

-

... More
All as per item Ser No 57.00 above here-in-before but 32 mm dia bore.

25

-

-

... More
All as per item Ser No 57.00 above here-in-before but 25 mm dia bore.

240

-

-

... More
All as per item Ser No 57.00 above here-in-before but 20 mm dia bore.

175

-

-

... More
S & F for 20mm CPVC Ball valve fixed in position complete all as specified and directed

15

-

-

... More
All as per item Ser No 62.00 above here-in-before but 25 mm dia bore.

22

-

-

... More
All as per item Ser No 62.00 above here-in-before but 32 mm dia bore.

5

-

-

... More
All as per item Ser No 62.00 above here-in-before but 40 mm dia bore.

10

-

-

... More
All as per item Ser No 62.00 above here-in-before but 50 mm dia bore.

6

-

-

... More
S&F in repair Float valve with epoxy coated aluminium rod and high density ball of size 20 mm bore dia complete all as specified and directed.

35

-

-

... More
S&F in repair Float valve with epoxy coated aluminium rod and high density ball of size 25 mm bore dia complete all as specified and directed.

20

-

-

... More
Supply and fixing in replacement of unserviceable water gauge of range 0-100 PSI, by making hole 80/100mm dia GI pipe line fixed alongwith the needle volveto control pressure in delivery line with including socket welding in pipe line complete, all as specified and directed.

4

-

-

... More
Taking up or down steel tubing of 25/32mm mm dia bore from floor/wall/trenches disconnecting all fittings including cleaning the pipe for removal rust and deposit to MES store all as specified and as directed.

70

-

-

... More
All as per item Ser No 70.00 above here-in-before but 40/ 50mm dia bore.

55

-

-

... More
Refixing/relaying old steel tubing of 25/32mm mm bore in new or old position on floor/wall/trenches including new GI fittings after cleaning by suitable chemical, roding, cutting to required length, screwing ends etc. as per site requirement complete including existing connection with required size of Tee or MS clamp with rubber bush all as specified and directed. Note: GI pipe retrieved from item No. 70.00 here-in-before shall be used after cleaning.

70

-

-

... More
All as per item Ser No 72.00 above here-in-before but for 40/ 50mm dia bore. Note: GI pipe retrieved from item No. 71.00 here-in-before shall be used after cleaning.

55

-

-

... More
Sampling of non chlorinated water from various pump houses under AOR of AGE R&D Agra as and when directed by Engineer-in-Charge and testing the water for bacteriogogical, Physical and chemical as per IS-1622 and 3025 from any Government/NABL approved laboratories and submission of test report to Engineer-in-Charge within 10 days of direction for testing as directed by Engineer-in-Charge complete all as specified and directed . Note:- Rate Quoted shall also deemed to be included for the followings (i) Cost of sterilized bottle as required. (ii)Collection of samplling water should be carried out in presence of JE/Engineer-in-Charge.(ii) Transportation charges for collection of samples from source (UG sump, bore & shallow wells) Test reports so collected will be submitted to the Engr-in-Charge

6

-

-

... More
Cutting existing CI pipe line of 80/100 mm dia for insertion of new tees, collars for branch connections complete all as specified and directed Note: Quoted rate shall be including of CI /DI specials, Joints and Earth work

4

-

-

... More
Arresting leakages of 100 mm bore sluice valves by replacing Gland packing, gland bush, gland flange, nut bolts, gasket, packing material as required after dismantling in existing position including testing on completion complete all as specified and directed. Note: Quoted rates inclusive of the materials mentioned above like Gland packing, gland bush, gland flange, nut bolts, gasket, packing material etc as required to arrest the leakages.

6

-

-

... More
All as per item Ser No 76.00 above here-in-before but 80 mm dia bore.

6

-

-

... More
Repair to the existing valve pit chamber of following sizes by demolishing the existing bricks work and foundation concrete and M&L for 230 mm thick brick walls of following size valve pit complte with mild steel sheet cover of 1.8 mm thick and angle iron of size 50x50x6mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and including locking arrangement and lifting handle and plastering in cement mortar 1:4 and 10 mm thick plaster to all internal and external exposed surfaces including two coats of white wash on wall complete all as directed.

-

-

-

... More
Valve pit size 1200x1200x900 mm

4

-

-

... More
Valve pit size 900x900x900 mm

4

-

-

... More
Valve pit size 600x600x350 mm

3

-

-

... More
Disconnecting all the connections of repaired DOL/oil immersed starter/auotmatic star delta starter of existing submersible/centrifugal motor upto 15 HP, 3 Phase 415V replace defective parts with new parts as per existing model/ type reassembling/ refixing the starter with necessary connection after the repair as required for proper functioning of motor commplete all as directed. Note: Quoted rates inclusive of all required spare parts like contactor,auxilary contactor,thermal relay unit,no volt coil,terminal block etc.

5

-

-

... More
S & F Framed work in repair such as grills for Staircase etc, gratings, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed. Note :- (i) Work is to be executed in RCC over head tank for fixing of steel to existing RCC member uptp 21 mm height and necessary scaffolding is deemed to be included in quoted rates. (ii) During excavation of work, the existing structure if damaged shall be rectified by contractor without any extra cost.

1250

-

-

... More
Taking out suction pipe 80 mm to 150 mm bore from sump of any capacity, dismantling of foot valve screwed / flanged type, and relowering after refixing in position the same duly cleaned / minor repair if any required such as replacement of rubber gasket/ lifting bolts & nuts including making thread for the suction pipes of sizes etc complete all as required and as directed.

3

-

-

... More
S&F in replacement 70 W LED, energy saving, environment friendly, long life exclusive innovating dia cast aluminium IP-66 protection, flood light suitable for highway lighting and general purpose including fixing arrangement and fixed on overhead tank's pillar / pump house complete all as specified and as directed.

2

-

-

... More
Supply, fabrication and fixing in replacement of valve chamber/UG Tank cover/RCC OH openning covers fabricated from 3mm thick MS sheet with suitable size of MS angle iron frame including locking arrangement, suitable handle , fixed with hinged arrangement and applying two coats of synthetic enameled paint over a coat of red oxide primer complete, all as specified and directed.

0.5

-

-

... More
Removing old rusted pipe line of 100mm GI raising main pipe under the over head RCC tank(18/21 Mtr height) and M&L for fixing of 100 mm New GI pipe medium grade with all fittings and connecting sluice valve ,supporting frame etc all as specified and as directed by Engineer-in-Charge . Note:- a. Neacessary scaffolding and manual/mechanical liftting arrangement to fixing the pipe shall be included in the quoted rate b. Removing exisiting sluice valve and refixing with new pipe also included in the quoted rate

165

-

-

... More
Removing/Taking up CI/steel tubing of 100mm dia bore laid in trenches disconnecting all fittings including cleaning the pipe for removal rust and deposit to MES store all as specified and as directed.

140

-

-

... More
All as per item Ser No 85.00 above here-in-before but 80mm dia bore.

95

-

-

... More
Refixing/relaying old CI/steel tubing of 100mm dia bore in new or old position in trenches including new GI/CI fittings after cleaning by suitable chemical, roding, cutting to required length, screwing ends etc. as per site requirement complete including connection with exsisting pipe line ,required size of Tee all as specified and directed. Note: Pipe retrieved from item No. 85.00 shall be used after cleaning.

140

-

-

... More
Refixing/relaying old CI/steel tubing of 80mm bore in new or old position in trenches including new GI/CI fittings after cleaning by suitable chemical, roding, cutting to required length, screwing ends etc. as per site requirement complete including connection with exsisting pipe line ,required size of Tee all as specified and directed. Note: Pipe retrieved from item No. 86.00 shall be used after cleaning.

95

-

-

... More
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches,pillars etc and removal of debris outside MoD land complete all specified and directed.

1.5

-

-

... More
M&L for brick work with fly ash bricks, old size, class designation 75(Kgf/cm2) straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 complete all as specified and directed.

1.5

-

-

... More
M&L for rendering 15mm thick in cement mortar 1:4 on brick/concrete surfaces finished even & smooth without using extra cement etc complete all as specified and directed.

10

-

-

... More
M&L for applying two coat of cement base paint over one coat of alkali resistant primer including preparation of new plastered brick/concrete surfaces as specified and directed.

10

-

-

... More
M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping etc including use & waste of form work in any position and shape complete all as specified and directed.

0.08

-

-

... More
Excavating in post holes in soft loose soil (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm

2

-

-

... More
M&L for plain Cement concrete type C-2 1:3:6 (40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.

0.25

-

-

... More
Demolition of RCC chajjas, slab, beam and similar work and removal of debris outside MoD land complete all as specified and as directed.

1.05

-

-

... More
M&L RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floo roofs, landings, balconies, canopies, deck slabs and in shelves and the like of RCC over head tanks, all as specified and directed.

2.8

-

-

... More
Use & waste of formwork to bottom and side of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) all as specified and directed by Engineer in Charge

14

-

-

... More
Use & waste of formwork to sides & soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc. Rough finished surfaces of concrete flat all as specified and directed.

10

-

-

... More
M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.

220

-

-

... More
M&L for two coat of synthetic enamel paint to new or previously untreated steel surface of any description, over 10cm in width or girth, not otherwise described over one coat of red oxide primer including preparation of surfaces as specified and directed.

55

-

-

... More
Complete removal of the wild grass/ vegetation from surrounding area of OHTs, Tubewells/Booster and installations area and making the surface clear and plain and spraying roundup chemical on the same clean area as directed after removing and depositing the same at a distance not less than 50 mtr away from the site complete all as specified and directed. Note- All necessary T&P will be provided by the contractor and no extra amount shall be paid for that seperately.

85

-

-

... More
Supply and installation with testing complete of digital water level indication device, operating on single phase supply direct display in (letter display) digit system in meter/CM of water of over head tank ensuring alarm while water fall or rise over predetermined limits with the following description complete all as specified and as directed by Engineer-in-charge including dismantling old unserviceable water level indicator. (a) The entire unit must operate through a compact electronic circuit which must ensure reliable operation at 230V + 10% at 50 Hz + 5%, with reliable in display and alarm at low and high level of over head tank. (b) One circuit must be housed in high impact polystyrene molded box with nylon molded connection strips. The level system must resistance transducer, while unattested by corrosion and other contents available in water. The product must be controlled by Micro switch. (c) The whole unit must electronically controlled and the upper level and lower level indications must be in two parts. Each complete part must be fitted in MS CRS sheet box separately. One must be installed at over head tank and second at pump house with proper powder coating paint with locking arrangements

2

-

-

... More
M & L for laying, connecting & testing four core copper conductor flexible PVC insulated heavy duty unsheathed cable 1100 volts grade 1.0 Sqmm from control box(water level sensor at RCC OHT) to display meter in pump room through ducts/under ground / suitable protection pipes etc including taking out unserviceable flexible cable all as specified and as directed.

130

-

-

... More
M&L for repair in leakages of 100 mm bore sluice valves by replacing Gland packing, gland bush, gland flange, nut bolts, gasket, packing material etc as required after dismantling ,refixing in existing position (inside the valve pit chamber of any type) including testing on completion complete all as specified and directed. Note: Quoted rates inclusive of the materials mentioned above like Gland packing, gland bush, gland flange, nut bolts, gasket, packing material etc as required to arrest the leakages .

3

-

-

... More
All as per item Ser No 105.00 above here-in-before but 80 mm dia bore.

2

-

-

... More
Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets , light fittings, etc taken on credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc., complete all as specified and as directed.

45

-

-

... More
Taking down carefully unservicable sub main wiring (4 Sqmm to 10 Sqmm size) including removal of batten/ conduit/ gutties/ wooden board etc and removal of unservicable items out of site complete all as specified and directed. Note: 2 runs of cable and one run earth wire will be measured as one length

55

-

-

... More
Material & labour for point wiring complete with FRLS, PVC insulated unsheathed cable, 1100 volts grade confirming to IS-694, ISI marked, 1.5 Sq mm (nominal area) single core with copper conductor for phase and neutral, multistranded drawn through and including non metalic rigid PVC conduit of 20 mm dia and conduit accessories concealed in walls, floors, roofs etc, complete terminal box flush in wall with cover plate of required for mounting switches, socket, fan regulator etc including provisioning of FRLS, PVC insulated un-sheathed 1100 volts grade, ISI Marked, 1.5 sq mm solid / multistranded copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and as directed for the following.

-

-

-

... More
One light / fan / bell point controlled by one switch

25

-

-

... More
One 3 pin 5 Amps socket out let on independent board.

10

-

-

... More
One 3 pin 5 Amps socket outlet on same board with other switches.

5

-

-

... More
M&L for point wring ,using approved colour coding (Phase-red, Neutral-black, Earth-green) complete for one socket outlet 5 Amp on independent board with FRLS PVC insulated and unshealthed stranded copper conductor cable 2.5 sqmm single core conforming to IS 694 in existing conduit including FRLS PVC insulated and unshealthed stranded copper conductor cable 2.5 sqmm single core in green colour as earth wire connected to earth dolly complete all as specified and directed .

5

-

-

... More
S&F switch piano flush button single pole two way 6 Amp, 240 Volts conforming to IS 3854 ISI marked complete all as specified and directed.

36

-

-

... More
S&F for socket outlet, 5 Pin, 6 Amp flush type conforming to IS 1293 ISI marked complete all as specified and directed.

15

-

-

... More
S&F switch piano flush button single pole one way 15 Amp, 240 Volts conforming to IS 3854 ISI marked including taking down old one complete all as specified and directed.

5

-

-

... More
S&F for socket outlet, 3 Pin, 5/15 Amp flush type conforming to IS 1293 ISI marked including taking down old one complete all as specified and directed.

5

-

-

... More
S&F ceiling rose, surface Bakelite, isolated body three terminals complete all as specified and directed.

25

-

-

... More
S&F Electronic fan regulator steped type (flush type) 240 volt ,50Hz ,single phase on existing phenotic laminated sheet one and connecting unserviceable including taking down old unserviceable complete all as specified and directed.

4

-

-

... More
S&F sub main wiring using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 6 sqmm as current carrying conductor and one run of 6.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm with standard accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directed including taking down old one Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.

55

-

-

... More
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete

12

-

-

... More
Supply and fixing LED light fitting 2 feet, 10W, 220 V AC decorative type with driver holder amp including connecting up with three core flexible copper conductor cable of suitable size complete.

3

-

-

... More
S & F LED light fitting 9W/10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.

6

-

-

... More
Material & Labour for fixing Isolator 40 Amp Triple pole , 415 volts, 36KA, type including necessary connection all as specifed and directed.

2

-

-

... More
S&F MCB TPN 63 Amp,C curve, 415 Volts, 50 Hz suitable for existing type and connection with copper lugs including taking down old unserviceable complete all as specified and directed.

3

-

-

... More
S&F MCB TPN 32 Amp,C curve, 415 Volts, 50 Hz suitable for existing type and connection with copper lugs including taking down old unserviceable complete all as specified and directed.

4

-

-

... More
Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron earth wire 4.00 mm dia by means of Copper nuts, bolts and washers. GI wire shall be laid in 20 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI wire of 4 mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.

4

-

-

... More
Disconnecting & taking out the existing defective Oil immersed star delta starter of any description, any capacity and in any position, 3 phase, 415 volts, 50 Hz suitable for AC supply submersible/centrifugal pump set upto 15 HP capacity and strip opening of Star delta starter, taking out unserviceable/defective wiring & parts, cleaning and servicing complete including replacement of unserviceable parts, reassembling, fixing in position, making connections and testing complete, all as specified and directed Notes :- (i) Quooted rate shall also including of replacement of spare parts like fixed contact, moving contact,over load coil,no volt coil ,cam spring,lever spring,Transformer oil etc as requiredcharges of the parts replaced/repaired is deemed to be included in these item

2

-

-

... More
M&L for cutting the existing GI pipe line 100mm dia and inserting Tee of size 100x100x50mm for making new branch conection of GI pipe of size 50mm dia including necessary fittings,excavation,returning and filling and depositing excavated material to a distance not exc 50m complete all as specified and as directad

1

-

-

... More
M&L for cutting the existing GI pipe line 80mm dia and inserting Tee of size 80x80x50mm for making new branch conection of GI pipe of size 50mm dia including necessary fittings,excavation,returning and filling and depositing excavated material to a distance not exc 50m complete all as specified and as directad

2

-

-

... More
S&F ACP retro(3/4 mm thickness) sign board of size 1.2x0.6 meter using retro reflective high intensity prismatic reflective sheeting.The back ground of board is ib Blue colour with white border and writing letter,numbers white in colour mentioning the pump house details and MES logo.Retro signboard shall be pasted on 3mm thick ACP sheet.The board shall be fixed on wall including fixing of fastners,nuts,bolts,washer etccomplete all as specified and directed.

6

-

-

... More
Isolate the water supply and empty the under ground water sump by using pumps of suitable capacity,after emptying the sump cutting/opening the existing rusted/damaged foot valve.S&F new foot valve of size 100mm bore,flanged/threaded type,IS:4038,PN 0.2 with strainer of cast iron IS 210 Gr FG200 and joining with existing suction pipe line including all connection items like nuts,bolts,washers,flanges etc complete all as specified and directedd.

1

-

-

... More
S&F in repair MCCB 125 Amps adjustable type 16 KA, 3 pole, 415 volt for pumphouse LT panel complete all as specified and directed.

1

-

-

... More
S&F in repair MCCB 100 Amps adjustable type 16 KA, 3 pole, 415 volt for pumphouse LT panel complete all as specified and directed.

1

-

-

... More
S&F in repair MCCB 63 Amps adjustable type 16 KA, 3 pole, 415 volt for pumphouse LT panel complete all as specified and directed.

2

-

-

... More
Roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc. all as directed by Engineer in charge

30

-

-

... More
M&L for Non-skid ceramic tiles 7 to 8 mm thick(squre/rectangular)area of each tile exceeding .06 sqm but exceeding 0.11sqm,in floors etc.set and joined in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick CM1:4 for laying flooe finishes complete all as specified and directed.

30

-

-

... More
Taking down cement/lime plaster of any description on brick work or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.

100

-

-

... More
M&L for rendering 15mm thick in cement mortar 1:6 on brick/concrete surfaces finished even & smooth without using extra cement etc complete all as specified and directed.

100

-

-

... More
Taking out or down defective sluice valve from main line and opening carefully old defective sluice valve 80 mm bore and in any position for and including servicing, over-hauling / greasing etc, and replacement of old unserviceable / worn out parts and reassembling the sluice valve after repair and refixing the same & testing after installation complete, all as specified and directed. Note :- (i) The cost of Earth work, joints & jointing materials washers, gaskets and minor parts shall be deemed to be included in the quoted rates(iii) Replacement of the defective parts i.e. cast iron gate & stainless steel spindle of Sluice valve shall also be included in the quoted rate.

3

-

-

... More
Supply and fixing LT panel board indoor type, cubical compartment pedestal mounting type fabricated CRCA sheet of 2.00 mm thick with both side open type, suitable for 3 phase 4 wire system, 415 volt with insulted Copper bus bar of size suitable to carry 1.5 times current of main MCCB incomer should be provided to length/width of the panel for free and smooth connection of the cable for MCCB, finished with powder coated, dust vermin proof, ventilated compartment door and necessary including arrangement for fixing on wall indoor with the following items including connection with suitable capacity of copper wire for internal wiring and connecting to LT UG cable using suitable size of lugs and testing and commissioning with foundation, including taking out the old U/S panel board from position and removing from site and make all electrical connection with existing outgoing/incoming cable to the new panel with suitable size lugs complete all as directed:- Incoming: a) MCCB 125 Amps ,25 kA, TPN 415 Volt ,Thermally adjustable - 02 Nos( 1 Nos Spare ) b) Copper Bus bar chamber strip size mm suitable for 250 Amps including insulator , hylem sheet , cable connection etc c) Indicator lamp LED type (RYB) –01 Set. Make- Seimens d) Volt meter Digital type 0-500V with selector switch. One set. e) Amps meter Digital type 0-500 A with CT & selector switch. 01 No. One set Outgoing: a) MCCB 63 Amps ,25 kA, TPN 415 Volt ,Thermally adjustable - 02 Nos (1 nos Spare) b) star delta starter suitable for 15 HP motors -02 Nos (1 Nos spare) "c) MCCB TPN 40 Amps -01 Nos" d) All interconnections between the main bus bar as well as outgoing MCCB shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of outgoing individual MCCB" Note :(i) Panel should be manufactured from CPRI approved firm only. (ii) Panel platform should be 1.5 ft hight from ground level (iii) conecting of existing UG cable as per site requirement"

1

-

-

... More
M&L for detection and rectification of leakages in refrigerant line by nitrogen gas to find out leakage in window / split type AC(1.5/2.0TR),water cooler/Deep freezer/Refrigerator of any model/make and ensuring the complete systems leak proof flushing out nitrogen gas including checking the system and charging/Topup of refrigerant gas R-134A / R 22/R-32 or any other refridgerant gas as required with appropriate quantity including testing for smooth functioning and re-assembling and re-installation in same/other position complete all as specified and directed.

75

-

-

... More
S&F in replacement Thermostat Switch as per exsisting size & model of Window/Split 1.5 TR/2.0 TR Capacity including taking out unserviceable Thermostat Switch from AC complete all as specified and as directed.

12

-

-

... More
S&F in replacement of Thermostat sensor of AC (Window/Split Type) 1.5 /2.0 TR and removal of unserviceable Thermostat sensor from AC complete all as specified and as directed.

8

-

-

... More
S&F in repair of PCB for indoor/Outdoor unit of Inverter Split AC of any type of capacity 1.5/2.0 TR including removal of old PCB complete all as specified and directed.

12

-

-

... More
S&F in repair of PCB for window AC 1.5/2.0 TR Hot & Cold, Inverter ACs of any type and capacity including removal of old PCB complete all as specified and directed.

10

-

-

... More
M&L for removing brunt wiring kit of window /spilt type ACs, water cooler replace with best quality new wiring kit suitable type of PVC insulated copper conductor cable including thimbles sleaves of suitable size & shape complete all as specified and directed.

15

-

-

... More
S&F in repair of PVC blower of Split Type AC 1.5/2.0 TR Capacity of approved Make and required Size to suit existing AC incuding removal of unserviceable blower complete all as specified and as directed.

8

-

-

... More
All as per item No 145.00 above but for window AC ( 1.5/2.0TR)

8

-

-

... More
M&L for dismantling of defective PCB of window/Split AC of 1.5/2.0 TR capacity of any make & type and refixing after repairing the PCB to ensure proper functioning of the AC complete all as specified and directed.

15

-

-

... More
Disconnecting electric connection of Split/Window air conditioner ,watercooler/Deep freezer of any capacity from any height and taking down/ keep aside servicing the same cleaning inside, cleaning of fins by means of airblower and water with pressure jet , cleaning of air filter, remove dust from body, tightening of loose nut bolt, washer, rubber gasket,tightening of loose wiring, loose connection and repair of parts, wornout nutbolt, washers, gasket,valves,temperature sensor,swing motor etc and necessary cutting, welding/soldering works with replacement of rusted body with new MS/GI Sheets of suitable size and making the applience fully functional and re-assembling and re-installation in same/other position and testing complete all as specified and directed. Note: (i) .All the repairs shall be carried out at MES store yard including transportation of equipment shall be contractor's own arrangment.(ii) All new parts will be measured and paid as supply only under the respective item.

126

-

-

... More
Supply only in replacement of starting/running capacitor of 5 to 30 mfd capacity for compressor of Window/Split Type ACs( 1.5 TR/2.0 TR) complete all as specified and as directed.

12

-

-

... More
Supply only in replacement of starting/running capacitor of 30 to 80mfd capacity for compressor of Window/Split Type ACs( 1.5 TR/2.0 TR) complete all as specified and as directed.

20

-

-

... More
Supply only in replacement of starting/running capacitor upto 5mfd capacity for Fan motor of Window/Split Type Acs ( 1.5 TR/2.0 TR) complete all as specified and as directed.

10

-

-

... More
Supply only Swing motor suitable for 1.5 TR / 2 TR window/split type ACs of any type/model complete all as specified and directed.

5

-

-

... More
Supply only temperature sensor for 1.5 TR / 2 TR window/split type AC of any type complete all as specified and directed.

5

-

-

... More
Supply only in replacement Air Filter suitable of AC (Window/Split type) 1.5 TR/2.0 TR Capacity complete all as specified and as directed.

12

-

-

... More
Supply only brass suction/discharge valve of size 1/4 ",3/8",1/2", 5/8" for 1.5TR/2.0TR of split AC/window AC complete all as specified and directedd

15

-

-

... More
Supply only drain pipe of 3 mtr length suitable for split type air conditioner of 1.5/2.0 TR of existing make complete all as specified and directed.

10

-

-

... More
Supply only in replacement compressor shut off valve of suitable size for window/split AC up to 2.00 TR capacity complete all as specified and directed.

7

-

-

... More
Supply only remote hand set of window/split type air conditioner of capacity 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed.

7

-

-

... More
Supply and fixing in repair of copper tubing 1/4", 1/2",3/8" dia complete all as specified and directed.

45

-

-

... More
Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 1.5 TR capacity and supply & fixing new condensing unit complete with compressor, condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with blade complete all as specified and directed.

2

-

-

... More
M&L in replacement of Starting Relay of AC (Window/Split Type) 1.0/1.5 TR/2.0TR Capacity including taking out unserviceable Relay from AC complete all as specified and as directed.

13

-

-

... More
M&L for dismantling of unserviceable/worn out reciprocating/hermetically sealed unit compressor from Deepfreezer/Refrigerator and replacement with new compressor, suitable for existing model/make including brazing with suction and discharge line, checking the system for leak proof and inclduing charging of refrigerant gas R-134 A /R-32 or required type in appropriate qty after making vaccum the complete system and testing for proper functioning complete all as specified and directed.

2

-

-

... More
M&L in replacement of Strainer with Capillary tube/capillary tube of Window/ Split Type AC 1.5 /2.0TR Capacity including taking out unserviceable Capillary Tube from AC complete all as specified and as directed.

15

-

-

... More
Supply and fixing of PVC nylon imbraided pipe15 mm dia for condensed water drain fitted on wall including all fittings complete all as specified and directed.

30

-

-

... More
S&F in repair of foam insulation heavy duty for 1.5TR/2.0TR split ACs refrigerant line as per exsisting size complete all as specified and directed.

135

-

-

... More
M&L for refrigerent gas charging (Top up)with required quantity of refrigerant R-22/R 32/R 407/R 410 or any other refrigerent as per the requirement in window & split ACs,water cooler,Deep freezer,Refrigerator of any capacity and make for its smooth functioning after carrying out vaccum and pressure test including necessary soldering/brazing to prevent leakage all as specified and directed.

68

-

-

... More
Taking out defective condenser fan motor from window type AC (Hot and Cold ACs or any other type) of capacity 1.5/2.0 TR transporting defective motor of any make & capacity from site at any height to contractor workshop dismantling the burnt winding & rewinding the blower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed.

8

-

-

... More
All as per item No 167.00 above but for condenser fan motor of split AC (1.5/2.0TR)

5

-

-

... More
All as per item No 167.00 above but for blower fan motor of split AC ( 1.5/2.0TR)

8

-

-

... More
Dismantling of defective indoor unit of 1.5 TR capacity split type AC (Hot and Cold ACs or any other type) and supply & fixing new indoor unit of the same capacity with blower motor, front grill and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required all as specified and directed.

2

-

-

... More
M&L for taking down of window/Split type AC of any capacity or model from any height/ any floor up to three storey building and shifting to another location in the same or other building and refixing at New Location including testing of leakage and charging/top up of specified gas as per the make of the AC and make it fully functional again at new location complete all as specified and directed.

14

-

-

... More
S&F in repair of Cooling/Heating coil complete with fins made of copper suitable for Window type AC (1.5/2.0 TR) as per existing model/size including removing of old cooling coil complete all as specified and directed.

9

-

-

... More
All as per item No 172.00 above but for split AC ( 1.5/2.0TR)

12

-

-

... More
S&F in repair of condensing coil complete with fins made of copper suitable for Window type AC (1.5/2.0 TR) as per existing model/size (Hot and Cold ACs or any other model) including removing of old condencing coil complete all as specified and directed.

10

-

-

... More
All as per item No 174.00 above but for split AC ( 1.5/2.0TR)

8

-

-

... More
Taking down defective condenser fan motor of 1.5/2.0 TR Split AC S&F new condenser fan motor as per exsisting make/model with copper winding complete all as specified and as directed.

6

-

-

... More
Taking down defective condenser fan motor of 1.5/2.0 TR window AC S&F new condenser fan motor as per exsisting make/model with copper winding complete all as specified and as directed.

8

-

-

... More
Taking down defective condenser fan blade of 1.5/2.0 TR window/split AC S&F new condenser fan blade as per exsisting make/model with copper winding complete all as specified and as directed.

10

-

-

... More
S&F Sheet metal enclosure with socket plug top and MCBs single pole with a two pin and earth plug and socket complete with one single pole MCB of "C" series of capacity 16-32 Amp including taking out the old one complete all as specified and directed.

20

-

-

... More
M&L metal clad Industrial plug top ISI mark 2 pin with earth 250 Volts including taking down old one complete all as specified and directed.

20

-

-

... More
Supply and fixing MCB SP 16-32Amps rating of 'C' series to be housed in industrial socket complete all as specified and directed.

15

-

-

... More
M&L Metal clad Industrial socket ISI mark with earth 250 Volts including taking down old one complete all as specified and directed.

18

-

-

... More
M&L for dismantling of unserviceable/worn out hermetically sealed unit compressor from window AC and replacement with new compressor, suitable for existing model/make (Hot and Cold ACs or any other model) of capacity 1.5/2 TR window type AC including brazing with suction and discharge line, checking the system for leak proof and inclduing charging of refrigerant gas R-134 A /R 22 /R-32 in appropriate qty after making vaccum the complete system and testing the AC for proper functioning complete all as specified and directed.

8

-

-

... More
All as per item No 183.00 above but for split AC ( 1.5/2.0TR)

7

-

-

... More
S&F of partical board, 12 mm thick prelaminated,BWR, grade 1, one side decorative teak veneers and other side commercial veneered finished fixing in small pices around window AC to make air tight on wall/window including necessary carpenter work complete all as specified and directed.

15

-

-

... More
S&F in repair of stand mounting bracket (heavy duty) for split AC (1.5/2.0TR) made of 2mm thick high steel power coating for rust prevention suitable for wall/floor mounted out door AC unit,including fixing with suitable fasteners on exsisting location/building (upto three storey) complete all as specified and as directed.

12

-

-

... More
S&F reverse cycle solenoid valve in split type AC 1.5 / 2 TR capacity with necessary extension to suction/ discharge copper tubing & toggle switch complete all as specified and directed.

4

-

-

... More
S&F 5 KVA wall mounted type stabilizer for automatic operation single phase naturally air cooled indoor type designed for input variation between 170Vto 285V and with output voltage stabilizer at 230V with accuracy of +/-2.5% complete and taking out old unserviceable stabilizer complete all as specified and directed.

8

-

-

... More
S&F in repair of PCB with high & low voltage cut off suitable for 4 KVA/5 KVA voltage stablizers of any make complete all as specified and directed.

5

-

-

... More
S&F in repair of power transfromers suitable for voltage stablizers of capacity 4/5 KVA complete all as specified and directed

7

-

-

... More
S&F sub main wiring using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with 2 x single core FRLS PVC insulated and unshealthed stranded copper conductor cable 4 Sqmm as current carrying conductor and one run of 4.0 Sqmm as earth contunity conductor, voltage rating 1100 volt, ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with standard accessories including taking down old one complete all as specified and directed. Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and PVC conduit shall be measured as one unit.

180

-

-

... More
M&L for removing the desert cooler from its existing position at any height from stand or pillar, removing the side panels, taking out unsv wood wool pads or loose pads including supporting jali(HDPE plastic /steel wire mesh)and disposed to a distance not exceeding 50 metres away as directed by EIC and spray painting with synthetic enamel paint of approved color (inside and outside) including one coat of black japan paint in side the base of tank tank after preparation of old painted surfaces and reassembling and fixing in position including oiling and greasing of fan kit, water pump motor, refixing wood wool pad secured with new HDPE soft mesh complete all as specified and directed.

99

-

-

... More
Taking down of unserviceable detachable type perforated side panel from exsisting desert coller S&F new perforated side panel made out 22 gauge PGI sheet suitable for desert cooler over all size of 0.750x0.750x0.910 mtr complete all as specified and directed.

24

-

-

... More
S&F in replacement of unserviceable wood wool pads with supreme quality white wood wool (set of three) in repair including PVC pipe pieces 03 Nos of required length & dia for connection of water distributor/ elbows of desert coolers of complete all as specified and directed.

85

-

-

... More
Supply and fixing in replacement of supreme quality white wood wool in loose suitable for industrial desert cooler complete all as specified and directed.

36

-

-

... More
S&F in repair of switch piano flush button single pole one way 15 Amp, 240 Volts in desert cooler conforming to IS 3854 ISI marked.

22

-

-

... More
Taking down unserviceable exhaust fan (heavy duty) of 16"/18" sweep size,2800 rpm from desert cooler, supply and fixing new exhaust fan (copper winding) of same capcity complete with fan blade ,fixing in the same position by providing new nut, bolts, washer, MS frame/side arms and rubber pads etc including testing complete all as specified and directed. Note :- Old unserviceable exhaust fan shall be deposited in MES Store Yard.

25

-

-

... More
Taking out defective exhaust fan of 16"/18"of any make from desert/industrial cooler and transporting it to contactor's workshop, opening of fan motor , taking out rotor, cutting out the burnt winding ,cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including insulation varnishing, greasing, painting reassembling testing and fixing in position complete all as specified and directed. Note :- Old unserviceable exhaust fan shall be deposited in MES Store Yard.

32

-

-

... More
Taking out defective desert cooler fan of capacity upto 300watt, 1500rpm capacity from desert cooler rewinding of the same with the existing size of super enameled copper winding including varnishing, greasing, painting reassembling testing and fixing in position complete all as specified and directed.

16

-

-

... More
Supply and laying or fixing or passing two core 4 sqmm stranded conductor laid throuth suitable size of PVC pipe on walll or floor, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armouredwith galvanised steel wire or tape and overall PVC sheathed.

85

-

-

... More
S&F in repair of Polycarbonate Plug top 3 pin 6/16 Amp of desert cooler/ACs complete all as specified and directed.

25

-

-

... More
Supply and fixing in repair of copper conductor three core PVC insulated and sheathed cable size 1.50 sqmm ISI mark for desert cooler complete all as specified and directed.

55

-

-

... More
Supply and fixing in renewal of desert cooler submersible pump having power of 18/20W,and out put 1200 Ltr/hr single phase 230 Volt AC, (ISI marked) suitable for evaporating type desert cooler including fixing clamp inside the desert cooler complete all as specified and directed

68

-

-

... More
Supply and fixing in renewal of desert cooler submersible pump having power of 40W & 3500 Ltr/Hr output, single phase 230 Volt AC, (ISI marked)suitable for Industrial type cooler including fixing clamp inside the Industrial type cooler complete all as specified and directed

18

-

-

... More
Supply and fixing in repair of steel multi wing exhaust fan blade set of best quality as per existing type and size of 16"/18" sweep heavy duty for desert cooler complete all as specified and directed.

22

-

-

... More
Taking down unserviceable fresh air fan motor (Fan kit) from desert cooler and supply and fixing new fresh air fan kit of copper winding (150-300Watt),1500 RPM,230 Volts single phase as per exiting sample/ size and fixing in same position by providing new nut, bolts, washer, MS frame/side arms and rubber pads etc including testing complete all as specified and directed.

20

-

-

... More
Taking down unserviceable exhaust fan frame S&F fan frame and sppoting Leg for exhaust fan including nut, bolts, washer Rubber,clamp etc complete Set complete all as specified and directed.

15

-

-

... More
S&F in repair of capacitor upto 4.5Mfd for desert cooler fan complete all as specified and directed.

30

-

-

... More
S&F of plywood 6mm thick, cut to shape as required on site fixing around wall/ window/ cooler opening with and including necessary nuts & bolts/ screws complete all as specified and directed.

25

-

-

... More
M&L for removing of perished body of desert cooler over all size 0.750x0.750x0.910 mtr from existing site and replace the same with new body made out of 22 gauge PGI sheet by means of fabrication welding/ jointing having tank size Approximet 0.750x0.750x0.230mtr and front grill made out of 26 gauge PGI sheet 0.460x 0.460mtr size for air flow direction, 03 Nos perforated sheet side panels size Approximate 0.680x0.610mtr of each and also having electric control panel consisting two nos 5amp switch, one rotary speed regulator switch complete and duly painted with two coats of synthetic enamel paint over one coat of primer internally and externally including fixing the exiting fan kit & Pump motor received from old unserviceable Desert Cooler including all electrical connections, testing and commisioning complete all as specified and directed.

18

-

-

... More
Taking out the unserviceable sealed compressor unit from water cooler and S&F New Sealed compressor unit of existing sample, suitable for 40/80 Ltr &60/120 Ltr capacity of water cooler replace with new compressor (duly tested) and checking the complete system for leak proof and including charging of refrigerant gas R-134 a in appropriate quantity and testing for smooth functioning complete all as specified and directed.

3

-

-

... More
Supply and fixing in replacement of evaporator coil ISI marked suitable for water cooler of any make/type/ capacity including all fixing accessories and making connection / detecting leakage and gas charging etc complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in repair of starting/running capacitor upto 30Mfd for blower motor of water cooler having capacity of 40/80 & 60/120 ltr complete all as specified and directed.

4

-

-

... More
S&F in repair of starting/ over load Relay for Water Cooler having capacity 40/80 and 60/120 Litres of any make including removing unserviceable relay complete all as specified and directed.

3

-

-

... More
S&F in repair of thermostat switch /relay suitalbe for water cooler having capacity 40/80 and 60/120 Litres of any make including removing unserviceable one complete all as specified and directed.

3

-

-

... More
S&F in repair of condenser coil(copper tubing) for Water Cooler having capacity 40/80 and 60/120 Litres of any make including removing unserviceable condenser coil complete all as specified and directed.

2

-

-

... More
Taking out the burnout blower motor from water cooler and S&F New single phase blower motor (copper winding) of existing sample/size suitable for 40/80 Ltr & 60/120 Ltr capacity of water cooler complete all as specified

2

-

-

... More
S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed.

4

-

-

... More
S&F in replacement steel waste water tray suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.

4

-

-

... More
Taking out defective water cooler blower motor any make/size from cooler upto 60/120 ltr capacity , cutting out the burnt winding cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including greasing, reassembling complete all as specified and directed.

3

-

-

... More
S&F in replacement of steel body desert cooler fan regulator of existing type and size including removing old regulator complete all as specified and directed.

15

-

-

... More
M&L for preparation of new plastered surface and applying two coats of OBD over a coat of primer complete all as specified and directed.

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.