Military Engineer Services Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Jan 2025
Closing Soon14 Feb 2025
Tender Amount₹ 12,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Shunt trip coil 24/30V DC. Make:L&T/Crompton greave/ABB

4

-

-

... More
Series trip coil 24/30V DC. Make:L&T/Crompton greave/ABB

4

-

-

... More
Power Pack for HT panel VCB for exection of relay.

4

-

-

... More
Supply and fixing of Vaccum intrupter as make of VCB. MAKE: Crompton/ABB

4

-

-

... More
Supply and fixing in replacement of spout of existing make of Vaccum circuit breaker as specifed and as directed at site

4

-

-

... More
Supply and fixing of PT of 11 KV grade for VCB of existing make as directed at site

3

-

-

... More
Supply and fixing of CT of 11 KV grade for VCB of existing make as directed at site

3

-

-

... More
Supply and fixing in replacement of T and C switch for VCB as specified and directed at site by Eng-in-Charge

5

-

-

... More
Supply and fixing in replacement of led bulb indicator for VCB as specified and as directed at site

10

-

-

... More
Supply and fixing in replacement of mail and female contacts of VCB of existing make of VCB. Make: ABB/Crompton

24

-

-

... More
Supply and fxing in replacement of Gear mechanism of vcb of existing make as specified and directed at site. Make: Crompton/ABB/GEC

3

-

-

... More
Dismantling existing worn-out 33 KV out door type gang operated air break switch triple pole & Disconnecting from existing system and Supply and installation and testing 33 KV outdoor type ,gang operated Air-break switch triple pole mechanically operated ,mounted on insulator Rotating type Horizental mounting with operating mechanism worked from ground level with 25 mm GI pipe (Med. grade) operating rod of suitable length with an ON-OFF position capacity 400 amps 9 insulator connected and out going with Steel nut bolts and washers all as specified and directed at site Make- PACTIL, Jaipuria brothers, National etc)

1

-

-

... More
Supply & fixing in replacement of worn out IDMP relay by Three Phase Over Current + Earth Fault Digital Protective Relay with high set, CT operated of rating 5.0 Amp, auxilary voltage -110 VAC, out put contacts-02 NO + 02 NC, selectable Fielf type, fixed in 33/11 KV HT panel including cutting slot in existing MS sheet of HT panel, if required and making internal control circuit service connection with FR PVC insulated copper wire of size not less than 2.5 sqmm including calibration, performance testing with necessary adjustment of over current /earth fault/earth leakage by artificial high current/capacitive synthetic current injection test on primary/secondary side as per IS-14658 : 1999 or IS 13516 : 1993 to check the CT ratio and polarity and to ensure physical healthiness with visual check for healthy tripping of over current and earth fault by adjustment of tripping time, flag setting, ratio setting, instantaneous time setting, delay time etc as per installed capacity of transformer with considering of percentage impendance of transformers for successful operation at the time of fault occurence complete with providing standby electric supply for testing complete all as specified and directed. Model No MC 61A, Cat Part NO MC61AAXX001 of Make -L&T or its equivalent model in Secure/Siemens/Areva/Kaycee/HPL as approved by GE (I).

2

-

-

... More
Routine and periodical cleaning around the area of out door swith yard of 33 KV Tech area, Chanmari and 11 KV sub stn RB, DRLM, T&GS, Nano & Polymer bldg, P29 transformer etc by cutting and removal/uprouting of unwanted grass/bushes, small trees including surface dressing and leveling by surface excavation wherever required complete in all respect or as directed.

3000

-

-

... More
Excavation in trenches in any type of soil not exceeding 1.5 Metre deep and not exceeding 1.5 metre width and getting out including forming bottom surface & sides to required slope/size as directed by the Engineer-in-Charge

50

-

-

... More
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by the Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.

12

-

-

... More
Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified & directed by Engineer-in-Charge.

18

-

-

... More
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.

25

-

-

... More
Supply and laying un-reinforced precast concrete cable cover HV class type -II with size 450 x 180 x40 mm, all as specified and directed

180

-

-

... More
S&L bricks burnt for protection of cable Sub class 'B' bricks laid dry flat across the cable with length of whole brick complete.

1

-

-

... More
Disconnecting electrically and taking out old unserviceable LT/HT UG cables any type and any size all as spfd and directed.

326

-

-

... More
Taking out carefully unserviceable LT/HT UG cable of up to 300 Sqmm from trenches and relaying same after repairs in same or other indicated location and testing complete all as directed. ( Note: Earth work, sand, bricks will be measured and paid separately)

100

-

-

... More
Supply & laying jointing and testing H.T. XLPE Insulated , Screened PVC bedded ,galvanised steel strip or wire armoured electric power cable(heavy duty) with aluminum conductor 11000 volt(E) grade cross sectional area 95 sqmm 3 core confirming to IS-7098 (Part I ) of 1988 laid in trenches/Duct on pole witth FI CLAMP, Nut bolt ,Aluninum Lugs -as required and directed at site Note- Joints will be measured and paid seprately. Make: Havells/Finolex/Polycab

60

-

-

... More
All as per item No.-26 but size of 120 sqmm 3 core 11 KV

80

-

-

... More
Supply & laying jointing and testing H.T. XLPE Insulated , Screened PVC bedded ,galvanised steel strip or wire armoured electric power cable(heavy duty) with aluminum conductor 33000 volt(E) grade cross sectional area 120 sqmm 3 core laid in trenches/Duct on pole with FI CLAMP, Nut bolt ,Aluninum Lugs -as required and directed at site Note- Joints will be measured and paid seprately.

60

-

-

... More
All as per item No.-28 but size of 300 sqmm 3 core 33 KV

26

-

-

... More
M&L Heat shrinkable type cable end joint outdoor type suitable for XLPE 120 Sqmm 3 core HT 33 KV cable and testing all as specified and directed with terminate joint and jointing material all as specified.

3

-

-

... More
All as per item No.-30 but size of end joint outdoor type suitable for XLPE 300 sqmm 3 core 33 KV.

2

-

-

... More
All as per item No.-30 but size of end joint indoor type suitable for XLPE 300 Sqmm 3 core HT 33 KV

2

-

-

... More
All as per item No.-30 but straight through joint Heat shrinkable 120 sqmm 3 core 33 KV.

3

-

-

... More
All as per item No.-30 but straight through joint Heat shrinkable 300 sqmm 3 core 33 KV.

3

-

-

... More
M&L Heat shrinkable type cable end joint outdoor type suitable for XLPE 120 Sqmm 3 core HT 11 KV (E) cable and testing all as specified and directed with terminate joint and jointing material all as specified.

3

-

-

... More
All as per item No.-35 but size of end joint outdoor type suitable for XLPE 95 sqmm 3 core

3

-

-

... More
All as per item No.-35 but size of end joint INDOOR type suitable for XLPE 120 Sqmm 3 core HT 11 KV (E) cable and testing all as specified and directed with terminate joint and jointing material all as specified.

3

-

-

... More
All as per item No.-35 but size of 95 sqmm 3 core

3

-

-

... More
M&L Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm

2

-

-

... More
All as per item No.-39 but size of 120 sqmm 3 core

2

-

-

... More
Dismantling existing worn-out old GOD and Supply and installation and testing 11 KV outdoor type ,gang operated Air-break switch triple pole mechanically operated ,mounted on insulator and steel frame with operating mechanism worked from ground level with 25 mm GI pipe (Med. grade) operating rod of suitable length with an ON-OFF position capacity 200 amps with dropout fuse & 12 insulator connected and out going with Steel nut bolts and washers all as specified and directed at site.

1

-

-

... More
Supply and laying GI Pipe light grade 80 mm bore with fittings for cable protection complete as all as required at site and directed.

8

-

-

... More
Providing the cable fault locating Machine with necessary T&P at site for locating exact pin point of fault along with the length of armourd 33/11 KV XLPE insulated HT cable complete all as required and directed at site

4

-

-

... More
S&Fin replacement of unserviceabile porceline vitreous bushing of required size / shape (suitable for exisiting transformer ) for spindle of transformer of any capacity 63 KVA to 750 KVA 11KV outdoor/indoor type siutable for HT side all as specified and directed

2

-

-

... More
All as per item No.-44 do but 1100 Volts grade suitable for LT side indoor type

2

-

-

... More
S&F in replacement of unserviceable brass spindle duly threded at the end complete with nut bolts and washer suitable for HT side of transformer out door/ indoor type all as specified and directed at site for the following capacity suitable for existing transformer of required size/ shape for spindle of transformer of any capacity up to 400KVA 11000 volts grade indoor type suitble for HT side all as specified and directed.

2

-

-

... More
All as above item No-46 but suitable for LT side of transformer of 400 KVA to 750 KVA capacity.

3

-

-

... More
M&L Lightning arresters expulsion type complete with all fittings, transmission class, 33 KV discharge capacity 65 kilo amp as specifed and as ditrected by E-in Charge. Make: Jaipuria, Rastriya.

1

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60×60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.

2

-

-

... More
M&L in replacement of aluminum conductor steel reinforced (ACSR) (any size upto panther) for 33 KV switch yard including, stringing, tightening binding jump ring & testing etc complete all as specified and directed.

0.25

-

-

... More
Supply and fixing in replacement of PG clamps for jumper connections aluminium die cast with two GI nut and bolts suitable for ACSR conductor upto panther on 33 KV HT OH lines.

14

-

-

... More
S&F in replacement of pin type porcelain, vitreous, white brown or green insulator including 1 galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nuts suitable for 33 KV complete all as specified and directed.

4

-

-

... More
Supply, fixing & connecting in replacement of worn out batteries by valve regulated lead acid (VRLA) maintenance free rechargeable battery of 2 Volt, 100AH, conforming to IS 15549/2005 and IEC 60896 - 21 & 22 for tripping system to HT breaker during fault occurence at 33/11 KV Sub station complete all as specified and directed.

4

-

-

... More
M&L for one coat aluminium painting and synthetic enamel painting of all MS channels, PT's, CT's, and other steel structures etc as per colour code of area not exceeding to 150 Sqm after proper preparation of old surface of 33 KV out door switch yard tech area and take over point chanmari complete all as specified and directed.

1

-

-

... More
M&L in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 2mm dia galvanised iron.

20

-

-

... More
S&F in replacement cable rout indicator with MS plate not less that 3.15 mm thick embosed of HT electric line adequate size with welded with 0.50 mtr long MS flat with PCC 1:3:6 (30cm x 30cm x 30 cm) including excavation 30cm x 30cm x 30 cm ,returning, filling and removing of soil including letter wrining for cable size location feeding with stancile as directed at site complete all as specifed and directed.

8

-

-

... More
Supply and fixing in replacement of PG clamps for jumper connections aluminium die cast with two GI nut and bolts suitable for ACSR conductor upto panther on 33 KV HT OH lines.

14

-

-

... More
S&F in replacement ammeter for 33 KV VCB panel digital type having range 0- 200 Amps operated with CT complete all as specified and directed.

5

-

-

... More
S&F in replacement of volt meter for 33 KV VCB panel digital type operated with PT complete all as specified and directed.

5

-

-

... More
S&F in replacement of frequency meter for 33 KV VCB panel digital type operated with PT complete all as specified and directed.

2

-

-

... More
S&F in replacement of Porcelain Post Insulators conforming to IS 2544/731/2486 (Part II), IEC 383/168 & BS 137 suitable for 33 KV nominal system voltage complete all as specified & directed.

2

-

-

... More
S&F in replacement of pin type porcelain, vitreous, white brown or green insulator including 1 galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nuts suitable for 33 KV complete all as specified and directed.

4

-

-

... More
S&F in replacement of disc insulator, porcelain, vitreousd bolt and socket type, white, brown and green suitable for 33KV(main receiving station) complete all as specified and directed.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.