Military Engineer Services Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Mar 2025
Closing Date7 Apr 2025
Tender Amount₹ 48,30,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(vi) Indication lamp 22.5mm dia LED type 240volts AC to show three phase availability-01Set. (H) Ventilating fans of required size to dissipiate the heat liberated by capacitor units complete with automatic switching ON and OFF of fans depending upon the temperature of the Panel. 230 V AC, 2650 rpm,160 Cu.m/h, Flying leads - 04 Nos (J) All accessories prewired with suitable size copper conductor cable insulated with fibre glass insulation to with stand high temperature, housed in cubical panel (CPRI approved) made out of 3.15 mm thick MS sheet factory made as per IEC 62208 duly powder coated front and rear door open able with locking arrangement complete with,IK 10 protection against mechanical Shocks as per IEC 62262 foundation as required or recommended by manufacturer. Make of APFC Panel Note: APFC Panel shall be manufactured by original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf and the panels so manufactured will not be accepted.

-

-

-

... More
M&L Painting to existing steel four pole structure of 11 mtr height including mild steel work like cross arms, clamps, pipe channel, bracing etc after cleaning and prepration of surfaces painting externally above painting depth with one coat of aluminum paint over a coat of aluminum primer including preparation of existing surfaces and marking pole numbers in 15 cm dia with approved colour in circular and making 03 Numbers & 02 Numbers of bands & strips with 30 cm wide fluorescent paint from bottom of pole to 1.5 mtr height of pole complete all as specified and directed. Note:- Cutting of bushes & tree branches upto 3 Mtrs height of pole shall be deemed included in quoted unit rate.

2

-

-

... More
M&L Painting to existing steel pole structure of 09 mtr height including mild steel work like cross arms, clamps, pipe channel, bracing etc after cleaning and prepration of surfaces painting externally above painting depth with one coat of aluminum paint over a coat of aluminum primer including preparation of existing surfaces and marking pole numbers in 15 cm dia with approved colour in circular and making 03 Numbers & 02 Numbers of bands & strips with 30 cm wide fluorescent paint from bottom of pole to 1.5 mtr height of pole complete all as specified and directed. Note : Cutting of bushes & tree branches upto 3 Mtrs height of pole shall be deemed included in quoted unit rate.

150

-

-

... More
Supply and fixing in replacement of off load change over switch in sheet metal enclosure 4 poles, 400 Amp rated, 440 volts, 50 Hzs, confirm to IEC 60947-3, IS/IEC 60947-3 alongwith extendable handle with making all connection and fixing accessories on surface of wall/panel operating handle etc complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement of off load change over switch in sheet metal enclosure 4 poles, 250 Amp rated, 440 volts, 50 Hzs, confirm to IEC 60947-3, IS/IEC 60947-3 alongwith extendable handle with making all connection and fixing accessories on surface of wall/panel operating handle etc complete all as specified and directed.

1

-

-

... More
M&L for recharging to existed earthing in any type upto stranded value using required chemical such as Nacl/ MgSo4 / other approvad chemical incl reveting / welding/ bolting to earth lead incl testing etc by Tech rep with riveting bolting replacing to nut bolt and washer etc to GI earthing strip for making earth continuity from transformer / panels to earthing pit complete all as site required and directed. Note:- Contractor should be submit the bldg wise earthing test result of resistance value with user signature to department in duplicate will be submitted to engr-in-charge.

100

-

-

... More
Supply and fixing glow sign board (box type) of size 1500 mm x 600 mm x 150 mm cladding PGI sheet 18 gauge fixed on aluminium angle of size 25 mm x 25 mm x 3 mm on top/bottom both side and transfrant acrylic both side and transfrant acrylic sheet 3.00 mm thick in front in which writing with arial black and provision of 3 Nos LED fitting 20 watt for illuminate the board suitable fixing/haning arrangement complete all as specified and directed.

2

-

-

... More
Supply and fixing acrylic sheet board 5 mm thickness size 1000 mm x 600 mm on which lay out of installation equipment (computerised Sketch) of electric supply. Distribution of Cable detail marked with different colour including all fixing accessories complete all as specified and directed.

10

-

-

... More
M&L for LT panel plinth foundation work using cement concrete in ration 1:2:4 as required with brick in minium size 1.5 Mtr X 0.9 Mtr X 0.75 Mtr ( 40 CM above and 30 CM below in normal GL) including plastering in varrious location given by Deptt complete all as specified and directed.

10

-

-

... More
Supply, erecting, connecting and testing of LT bus bar chamber in replacement in cubical housing cabinet, outdoor type, platform mounted (minimum height 45 CM above normal GL and 30 CM below normal GL) angle iron frame grouted in PCC foundation , factory made, totally enclosed, dust and vermin proof made out by 3.15 MM thick CRCA MS sheet of overall indicating size 600 x 600 x 450 MM and full built upon angle iron frame in size 40 x 40 x 5 MM, having front and rear hinged both side open able doors and lifting lugs (02 Nos) , locking arrangement to be connect to earthing strip at rear side, bottom detachable both side open able ,gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers sheet steel bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment painted epoxy powder coated comprising 04 Nos Aluminium conductor equal size 600 Amps rated colour sleeve insulated bus bar mounting on heat shrinkable insulator both side incl grouting in PCC foundation including taking down existing material complete all as specified and directed.

4

-

-

... More
Supply, install, testing and commissioning of LT panel in replacement of size 80 cm x 80 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door with front and rear openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following :- INCOMING (i) MCCB 160 Amp ,415 Volt,25 KA, 4 pole Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = % Icu at 415 V (kA rms) 50%, frame type,Confirms to IS/IEC60947-2 (iii) Phase indicating lamp LED type with HRC fuse – 1 Set of three. (iii) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos (iv) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal coloured code of size 96x96mm-01No (v) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’s duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm – 01 No. (vi) Aluminium bus bar 200 Amps capacity of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos. OUT GOING (ii) MCCB 63 Amp ,415 Volt,25 KA, 4 pole Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) 50%, frame HIM125 type,Confirms to IS/IEC60947-2 =Qty 04 Nos

3

-

-

... More
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,foundation filling of poles or stays and for rerouting of cables complete all as specified and directed.

357.41

-

-

... More
Returning filling, including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required complete all as specified and directed.

167.79

-

-

... More
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.

189.62

-

-

... More
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and directed. Note:- Punned thickness shall be measured and paid.

142.97

-

-

... More
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed.

14.12

-

-

... More
M&L for pre cast cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) for foundation filling of poles or LT panels as mass concrete complete all as specified and directed.

2

-

-

... More
M&L for pre cast cement concrete ( 1:3:6) type C2 (using 40mm graded stone aggregate) for foundation filling of stays complete all as specified and directed.

1

-

-

... More
Demolition of cement concrete (un-reinforced) in ground, floors or pavings not exceeding 15 cm thick below or above ground level complete all as specified and directed.

2

-

-

... More
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in floor / hard-standing, surface finished even and smooth without using extra cement to match with the existing surface complete all as specified and directed.

2

-

-

... More
M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable bore for protection cable & pipe upto 80 mm bore complete all as specified and directed. Note: Depth of bore shall not be more than 1 Mtr from original ground level.

36

-

-

... More
Supply and laying to wall or poles or fixing or passing through pipe, in replacement of 1100 volts grade heavy duty cable with XLPE insulated aluminium multistranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed 16 sq. mm nominal cross section 4 core in service connections complete all as specified and directed. (Note : Including making good all distributed wall surfaces/ flooring/tilling to match with existing specification)

540

-

-

... More
Supply and laying in trenches or fixing to wall/pole or passing through pipe in replacement of XLPE insulated heavy duty armoured electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core complete all as specified and directed. (Note : Including making good all distributed wall surfaces/ flooring/tilling to match with existing specification)

520

-

-

... More
All as per item No 24 above but cable of size 35 Sqmm 3.5 core complete all as specified and directed.

240

-

-

... More
All as per item No 24 above but cable of size 50 Sqmm 3.5 core complete all as specified and directed.

450

-

-

... More
All as per item No 24 above but cable of size 70 Sqmm 3.5 core complete all as specified and directed.

430

-

-

... More
All as per item No 24 above but cable of size 95 Sqmm 3.5 core complete all as specified and directed.

400

-

-

... More
All as per item No 24 above but cable of size 120 Sqmm 3.5 core complete all as specified and directed.

400

-

-

... More
All as per item No 24 above but cable of size 185 Sqmm 3.5 core complete all as specified and directed.

250

-

-

... More
All as per item No 24 above but cable of size 240 Sqmm 3.5 core complete all as specified and directed.

300

-

-

... More
S&F in replacement of cable jointing kit for 1100 volt grade cable for straight through termination heat shrinkable type with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5/4 core complete all as specified and directed.

4

-

-

... More
All as per item No 32 above but for 25 to 50 Sqmm size complete all as specified and directed.

5

-

-

... More
All as per item No 32 above but for 70 to 150 Sqmm size complete all as specified and directed.

5

-

-

... More
All as per item No 32 above but for 185 to 240 Sqmm size complete all as specified and directed.

4

-

-

... More
Dismantling insulator any type and any size from LT over head lines and fixing other side complete all as specified and directed.

20

-

-

... More
Dismantling, cross arms, clamps, supports made of channels or angle section etc including nuts and bolts and setting aside for re use complete all as specified and directed.

1.2

-

-

... More
Dismantling stay assy complete including excavation for taking out PCC block breaking of PCC block for taking out MS plate and depositing iron item to MES store yard and removing of PCC from site complete all as specified and directed.

1

-

-

... More
Dismantling PCC/steel poles any type and any size including excavation for taking out pole, breaking of PCC block with due care and setting aside for reuse or depositing to MES stores yard complete all as specified and directed.

8

-

-

... More
Unbinding from insulators ACSR conductor any size of LT/HT over head line for repairs. Re-stretching of ACSR conductor to achieve proper sag(All wire in a span) and rebinding to the insulators using alumn/GI binding wire and making all existing cable connections all as required at site complete all as specified and directed.

30

-

-

... More
S&F Aluminium conductor of any size with steel reinforced complete all as specified and directed.

0.5

-

-

... More
Supply and fix galvanized steel wire any size to LT over head line as continuous earth or fabrication of guarding cradles complete all as specified and directed.

0.5

-

-

... More
S&F cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia complete all as specified and directed.

0.2

-

-

... More
Supply, errecting and installation of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) duly painted with two coat of black bituminous paint through out, internally and externally up to planning depth and painting remaining portion of pole with two coat of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making/painting three Nos circular strips each of 30 cm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking pole number with black paint complete all as specified and directed. (Note : Excavation, earth work, PCC work shall be measured and paid separately under respective items)

8

-

-

... More
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape ors size as indicated or directed and inclusive of oneprimer coat, one under coat and one finishing coat of alumn paint complete all as specified and directed.

0.5

-

-

... More
M&L for stay assy complete with MS stay plate of size 300x300x6mm thick, stay rod 16mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I of 1991 complete all as specified and directed. ( Excavation, PCC, and loop type insulators will be measured separately).

1

-

-

... More
M&L for loop type insulator large size with overall dimensions 90x140mm with clearance of hole 25.5 mm vitreous white brown or green complete all as specified and directed.

1

-

-

... More
S&F Pin type, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed.

20

-

-

... More
M&L for replacement of GI tubing light grade 80mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )

15

-

-

... More
M&L for replacement of GI tubing light grade 50mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )

10

-

-

... More
M&L for replacement of GI tubing light grade 40mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )

10

-

-

... More
Supply and fix in replacement bus bar chambers 300 mm long iron clad with 4 Nos 200 Amp rated copper strips complete fixed flush wall and making good the disturbed wall surfaces complete all as specified and directed.

5

-

-

... More
Supply and fix in replacement bus bar chambers 300 mm long iron clad with 4 Nos 100 Amp rated copper strips complete fixed flush wall and making good the disturbed wall surfaces complete all as specified and directed.

3

-

-

... More
M&L for repair & welding of LT feeder pillar box / APFC panel front / rear door and locking arrengement with lock & key including minor parts such as hinges, screw, nuts & bolts, gaskets etc including paint patch work making good as per existing colour and complete all as specified and directed.

5

-

-

... More
Supply & fix in replacement of front and rear door of LT feeder pillar box according to existing feeder pillar box size made up of 3.15 mm thick MS sheet with two coat of existing feeder pillar box colour paint over and including one coat of red oxide primer complete all as specified and directed.

75

-

-

... More
Supply,installing, testing and commissioning in replacement outdoor type LT feeder piller box double door type (Safety Centre) of suitable size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double, front side openable, type IP-54 protection made of CRCA sheet 3.15 mm thick of outer panel and 2.00 mm thick inner compartment of panel size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Plat form min 45 cm from ground level and PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board including disconnecting cable from old unsv LT feeder piller box with MCCB, MCB, main switch, busbar and dismantling the same complete with the following items housed in :- BUSBAR :- 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar). INCOMING:- (i) 4 pole MCCB of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with overload adjustability with rotary handle- 01 No. (ii) Digital multifunctinal meter V, A, F, kW, KVA, kWh, kVAh, kVArh, THD, Neutral current, Max Demand (with RTC),- 01 No. (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set (iv) CT (200/5A) -03 Nos OUTGOING:- (a) 4 pole MCCB of capacity 100 Amp, breaking capacity 25 KA with themal magnetic release adjustable type - 04 Nos (b) MCCB 4 pole of capacity 63 Amp breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 01 Nos (NOTE: Rate quoted shall be deemed to be inclusive of replacement of all cable lugs, by removing damaged part of cable and taking out cable from loop to required length including necessary earth work as per site requirement or as directed by Engr-in-charge)

2

-

-

... More
Supply,installing, testing and commissioning in replacement outdoor type LT feeder piller box double door type (Safety Centre) of suitable size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double, front side openable, type IP-54 protection made of CRCA sheet 3.15 mm thick of outer panel and 2.00 mm thick inner compartment of panel size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Plat form min 45 cm from ground level and PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board including disconnecting cable from old unsv LT feeder piller box with MCCB, MCB, main switch, busbar and dismantling the same complete with the following items housed in :- BUSBAR :- 600 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar). INCOMING:- (i) 4 pole MCCB of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with microprocessor release type with overload adjustability - 01 No. (ii) Digital multifunctinal meter V, A, F, kW, KVA, kWh, kVAh, kVArh, THD, Neutral current, Max Demand (with RTC),- 01 No. (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set (iv) CT (200/5A) -03 Nos (v) Square type heavy duty capacitor 440 V,10 KVAr conforming to IS 13340-1993 incl suitable fixing and paralell connection with the commercial line Outgoing: (a) 4 pole MCCB of capacity 250 Amp, breaking capacity 25 KA with microprocesser release adjustable type-3 Nos (b) MCCB 4 Pole of capacity 125 Amp breaking capacity 25 KA with microprocessr release, adjustable type- 1Nos. (Note) : Rate quoted shall be deemed to be inclusive of replacement of all cable lugs by removing damage part of cable and taking out cable from premises shall be carried out by the Engr-in-Charge or rep of GE (I) Kanpur has detaild by GE

1

-

-

... More
S&F in replacement of MCCB 4 Pole 415 Volts 3 phase 630 Amps adjustable type breaking capacity 50 KA, complete all as specified and directed.

2

-

-

... More
All as per item No 58 above but MCCB 400 Amps 36 KA complete all as specified and directed.

1

-

-

... More
All as per item No 58 above but MCCB 250 Amps 36 KA complete all as specified and directed.

4

-

-

... More
All as per item No 58 above but MCCB 200 Amps 36 KA complete all as specified and directed.

4

-

-

... More
All as per item No 58 above but 160 Amps 36 KA complete all as specified and directed.

5

-

-

... More
M&L in replacement of MPP heavy duty capacitor bank including cylindrical type, 3 phase 440 volts of capacity 7.2 KVAR including necessary copper lead copper lugs of suitable size complete all as specified and directed.

5

-

-

... More
All as per item No 63 above but capacity 14.2 KVAR complete all as specified and directed.

5

-

-

... More
All as per item No 63 above but capacity 21.4KVAR complete all as specified and directed.

6

-

-

... More
All as per item No 63 above but capacity 35.5 KVAR complete all as specified and directed.

7

-

-

... More
S&F in replacement of power factor controller relay of 12 steps suitable for operation at 415 V power and auxiliary both 5 amp as current measurement. The relay shall improve the PF by at least 0.98. The relay shall be microprocessor based with self diagnostic and setting complete all as specified and directed.

2

-

-

... More
Material & Labour in replacement of copper wire for control circuit in capacitor bank of size 2 core 2.5 sqmm 1100 volts grade complete all as specified and directed.

180

-

-

... More
Material & Labour in replacement of copper wire for control circuit in capacitor bank of size 2 core 4 sqmm 1100 volts grade complete all as specified and directed.

180

-

-

... More
S&F in replacement MCB SP 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.

10

-

-

... More
All as per Item No. 70 above but SPN of rating 16-32 Amps complete all as specified and directed.

20

-

-

... More
All as per Item No. 70 above but TPN of rating 40-63 Amps complete all as specified and directed.

35

-

-

... More
S&F in replacement Electronic Thyristor Module of each APFC PANEL 3 pole / 4 pole AC of capcity having coil voltage 250 volt 5 -10 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed.

3

-

-

... More
S&F in replacement Electronic Thyristor Module of each APFC PANEL 3 pole / 4 pole AC of capcity having coil voltage 250 volt 25-50 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed.

3

-

-

... More
Taking down carefully transformer any capacity, any make, any type from pole / plinth by dismantling, dis-connecting HT & LT sides, earthings of transformer, supporting angles / cross arms, shifting / transporting transformer carefully from the site/store and shifting/refixing in other location under GE Kanpur after cleaning and making all electrical/earthing connections complete all as specified and directed.

1

-

-

... More
Dismantlling top cover of transformer 11/.440 KV of capacity upto 750 KVA , any make for repair / replacement of HT / LT bushing of transformer or for replacement of top cover gasket or for inspection of transformer or for minor internal repairs of transformer all including draining carefully transformer oil as required / upto the required level and refilling the same, re fixing the top cover of transformer after completion of the work including testing on completion complete all as specified and directed. Note - spare parts will be measured and paid separately

1

-

-

... More
Dismantling old u/s HT 11 KV bushes and fixing in replacement of HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity up to 250 KVA complete all as specified and directed.

8

-

-

... More
Dismantling old u/s HT 11 KV bushes and fixing in replacement of HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity exceeding 250 KVA upto 750 KVA complete all as specified and directed.

8

-

-

... More
Dismantling old u/s LT bushes and fixing in replacement of LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, locknuts and rubber seal for indoor/outdoor transformer of capacity not exceeding 250 KVA complete all as specified and directed.

10

-

-

... More
Dismantling old u/s LT bushes and fixing in replacement of LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, locknuts and rubber seal for indoor/outdoor transformer of capacity exceeding 250 KVA upto 750 KVA complete all as specified and directed.

10

-

-

... More
Repairs to the leaks of transformer from tap switch/ fins/ any pats of body, by replacing gasket / seal , or Repairs to the leaks of transformer body / fins, by welding / brazing etc complete all as specified and directed.

10

-

-

... More
M&L for taking out old burnt winding and rewinding of HT/LT coil of any type, capacity and make of transformer with approved quality supper enamelled copper wire/ strip of approved make of suitable gauge and number of turns along with allied materials like cork sheet, fibre glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc complete all as specified and directed.

210

-

-

... More
S&F in replacement of temperature gauge circular dial type of standard size and dia suitable for indoor/outdoor type transformer upto 750 KVA complete all as specified and directed.

5

-

-

... More
M&L for replacement and full fill up fresh silica gel in assembly at site complete all as specified and directed.

8

-

-

... More
S&F Top gasket made of 3mm thick cork sheet with suitable holes for 33/11/6.6/0.433 KV transformer of any type/capacity including providing suitable size of bolts, nuts and washer for transformer top cover complete for any capacity/size transformer complete all as specified and directed.

20

-

-

... More
Disconnecting electrically, open the cover of transformer any type/size and filteration and dehydration of Transformer oil for 33/11 / 6.6 / 0.433 KV transformers, with stream line mobile filtration plant (To be provided by contractor & quoted prices deemed to include its hire charges) at a temp from 60-75 degree celsius to achieve the dielectric strength of oil 60 KV or over at standard gap as per IS 335 of 1993 (Fourth revision) to remove the moisture from winding and core complete all as specified and directed. Note : (a) Filtration should be carried out in OFF position, therefore generator and cables will have to be arranged by the contractor at his own cost. (b) Test result will be recorded before and after filtration of oil and submitted to Engr-in-Charge in a prescribed manner.

4500

-

-

... More
Cleaning of transformer of size 63 KVA to 315 KVA outer surface suitable for painting and painting with two coat of synthetic enamel paint by spray machine of light grey colour or as directed including transformer accessories such as radiator, conservator tank, marshalling box and incl writing SM No/size/ feeder name etc complete all as specified and directed.

10

-

-

... More
Cleaning of transformer of size 315 KVA to 750 KVA outer surface suitable for painting and painting with two coat of synthetic enamel paint by spray machine of light grey colour or as directed including transformer accessories such as radiator, conservator tank, marshalling box and incl writing SM No/size/ feeder name etc complete all as specified and directed.

7

-

-

... More
M&L for marking/writing feeder names/ SM No / MES No for HT/LT Electrical Eqpts like VCB, Tfrs, LBS / RMU/panels etc with synthetic enamel paint of approved color complete all as specified and directed.

15

-

-

... More
Earthing complete with GI plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable and making test point and all connections complete all as specified & directed by Engr-in-charge.

18

-

-

... More
M&L for cutting, trimming of branches along the OH conductor of LT/ HT line within 2 mtr distance along both side of line and strictldispose them at suitable place complete all as specified and directed.

60

-

-

... More
Removal of unwanted vegetation/bushes/small plants/ shrubs complete inside/outside the installations all around and surface excavation not exceeding 15 cm depth levelling the ground and removing the excavated material to a distance exceeding 50 Mtr complete all as specified and directed.

1200

-

-

... More
Supply and filling broken/crushed stone boulder filling dry handpacked tightly laying in layers on ground surface in size 40 to 50 MM after excavation, removing, dressing, leveling, compact work etc all as per site rquirement on of complete all as specified and directed. Note:- Quoted unit rate shall be deemed included cost required for earth work to prepare the surface for laying boulder in layers with compact work.

40

-

-

... More
M&L for cement concrete type B2 in ratio 1:2:4 using 40 MM graded stone aggregate in foundation filling and mass concrete complete all as specified and directed.

25

-

-

... More
M&L for cement concrete type C2 in ratio 1:2:4 using 20 MM graded stone aggregate in foundation filling and mass concrete complete all as specified and directed.

20

-

-

... More
Transportation of Transformer from site E/M yard to workshop for repairing and from workshop to site /E/M yard after repair etc of capacity upto 750 KVA complete all as specified and directed. Note:- The rate deemed to be included of transportation charges.

1

-

-

... More
Material and labour for dismantling of complete HV/LV coils of transformer upto 750 KVA (33/11/6.6/0.433 KV) and segregating, serviceable and unserviceable coils, serviceable coils shall kept aside for reuse after complete varnishing and testing of each coil including removal of complete core and accessories such as HV / LV bushings with metal parts, oil temp indicator ,winding temp indicator and disconnection of OTI, WTI complete all as specified and directed. Note : 1. Rewinding of defective HV / LV Coils shall be measured and paid seperately. 2. The rate deemed to be included of all tools and plants.

1

-

-

... More
M&L for Open the cover of transformer any type/size on site and filling in with new transformer oil low viscosity of approved make as per IS-335 of 1992 including heating of oil and die-electric strength 60 KV when tested at 4mm gap complete all as specified and directed.

600

-

-

... More
S&F On load change over switches in open execution as per required make 4 pole4 15 V, 50 Hz 250A conform to IEC 947-3, EN-60947 AC 23 A front operated complete all as specified and directed.

1

-

-

... More
S&F On load change over switches in open execution as per required make 4 pole4 15 V, 50 Hz 400A conform to IEC 947-3, EN-60947 AC 23 A front operated complete all as specified & directed.

1

-

-

... More
M&L in replacement of ACB 4 pole 415 volt with thermal magnetic release (Manual Fixed type) of capacity 630 Amps complete all as specified and directed.

1

-

-

... More
Detection of any type of fault in HT underground Line (laid in soil at plane area or forest area) with the help of Cable fault locator machine. Cable fault locator with carring vehicle will be brought by the cable fault detection agencies. Span of faulty cable will be trace out by the agencies by meggering HT cable complete all as specified and directed. Note : 1. Detection of fault in one span of length will be measured as one Job either machine placed from one side or both side of the cable. 2. Technicians will be employed by the working agencies. 3. Earth work and taking out will be measured and paid seperately. 4. Material for repair and replacement measured and paid saperately. 5. One job shall be measured if the fault has successfully identified by the fault locator machine or removing moisture in the cable if required.

5

-

-

... More
M&L for earthing with hot dip galvanized steel pipe in pipe electrode, outer pipe 88mm dia medium grade and inner pipe 55 mm dia including testing, 3 mtr long and having 50x6 mm terminal on inner pipe to connect earthing strip with 14 mm holes for nut bolts, buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 100 mm dia and 3.3 mtr deep using suitable mechanical drilling machine (for drilling near the specified bldg) connected with galvanized steel earthing lead of 32x6 mm strip with minimum two Nos of GI nut bolits and connected to test point from earthing pit. The electrode pipes should be filled with 2x 25 kg bags of carbon based earthing compound. The resistance of the compound should be less than 0.1 Oms . The compound should be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities with ph value between7-9. Connected to the earthing test point, Fiber reinforced plastic pit not less than 300x300 mm with pit cover, including necessary returning filling & removal of extra soil , to achieved earth resistance value less than 5 Oms including testing complete all as specified Make U-Protect or equivalent NOTE: IF the desired result not obtained after testing the contractor should do re-eathing without any extra cost.

12

-

-

... More
M&L Aluminum lugs eye lid or barrel type complete with cripping/soldering etc including removing the wornout lugs suitable for aluminium cables/copper cables of sizes from 16 Sqmm to 95 Sqmm complete all as specified and directed.

100

-

-

... More
Supply and fixing Adjustable thermal and fixed magnetic setting based MCCB 4 Pole 630 Amps, Rated Ultimate Shortcircuit Breaking Capacity 36 KA Icu at 415 V, Rated service short circuit Breaking capacity Ics=100% Icu at 415V (KA rms) along with spreader terminals (extended copper terminals-04 Nos) including taking out existing UNSV / burnt MCCB from site complete all as specified and directed.

2

-

-

... More
Supply and fixing Adjustable thermal and fixed magnetic setting based MCCB 4 Pole 400 Amps, Rated Ultimate Shortcircuit Breaking Capacity 36 KA Icu at 415 V, Rated service short circuit Breaking capacity Ics=100% Icu at 415V (KA rms) along with spreader terminals (extended copper terminals-04 Nos) including taking out existing UNSV / burnt MCCB from site complete all as specified and directed.

3

-

-

... More
Supply and fixing Adjustable thermal and fixed magnetic setting based MCCB 4 Pole 320 Amps, Rated Ultimate Shortcircuit Breaking Capacity 36 KA Icu at 415 V, Rated service short circuit Breaking capacity Ics=100% Icu at 415V (KA rms) along with spreader terminals (extended copper terminals-04 Nos) including taking out existing UNSV / burnt MCCB from site complete all as specified and directed.

3

-

-

... More
Supply and fixing Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 250 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 KA Icu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) along with spreader terminals (extended copper terminals-04 Nos) including taking out existing UNSV / burnt MCCB from site complete all as specified and directed.

10

-

-

... More
Supply and fixing Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 160 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 KA Icu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) along with spreader terminals (extended copper terminals-04 Nos) including taking out existing UNSV / burnt MCCB from site complete all as specified and directed.

10

-

-

... More
Supply and fixing Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 100 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 KA Icu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) along with spreader terminals (extended copper terminals-04 Nos) including taking out existing UNSV / burnt MCCB from site complete all as specified and directed.

12

-

-

... More
Supply and fixing Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 63 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 KA Icu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) along with spreader terminals (extended copper terminals-04 Nos) including taking out existing UNSV / burnt MCCB from site complete all as specified and directed.

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.