Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Nov 2024
Closing Date17 Dec 2024
Tender Amount₹ 49,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for sand cushioning to U/G cable in layers of 23cm thick (8 Cm before laying the cable and 15 cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed. Note: Only punned thickness 18 cm shall be measured and paid.

97.2

-

-

... More
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed.

4.8

-

-

... More
M&L for drilling manually in soft/loose/ hard soil under road ,pavement hard standing for protection of GI pipe up to 80mm dia complete all as specified and directed. Note Depth of bore shall not be more than 1 Mtr from ground level.

30

-

-

... More
Supply & laying in replacement of GI tubing of 80 mm bore, light grade conforming to IS 1239- Part-I and ISI marked in trenches, across the road, on wall or pole or culvert etc including required fixing arrangement of length for cable protection complete all as specified and directed.

30

-

-

... More
Supply, laying in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened PVC sheathed galvanized steel strip or wire armoured electric power cable with aluminium conductor of cross sectional area 95 Sqmm 3 core 11 KV rated suitable for earthed system including testing and commissioning complete all as specified and directed Note : (Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately under relevant item).

300

-

-

... More
All as per item No 8 above but HT 11 KV cable of size 120 Sqmm complete all as specified and directed.

300

-

-

... More
All as per item No 8 above but HT 11 KV cable of size 185 Sqmm complete all as specified and directed.

240

-

-

... More
Supply and fix cable end jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed.

4

-

-

... More
Supply and fix cable end jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed.

4

-

-

... More
Supply and fix cable straight through jointing kit for 11 KV (Earthed) grade cable termination heat shrink type joint with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed.

5

-

-

... More
Supply and fix cable straight through jointing kit for 11 KV grade cable termination heat shrink type joint with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed.

6

-

-

... More
Supply, laying in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened PVC sheathed galvanized steel strip or wire armoured electric power cable with aluminium conductor of cross sectional area 300 Sqmm 3 core 33 KV rated suitable for earthed system including testing and commissioning complete all as specified and directed Note : (Excavation, earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately.

70

-

-

... More
Supply and fix cable end jointing kit for 33 KV grade cable for outdoor termination heat shrink type joint with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 Sqmm complete all as specified and directed.

2

-

-

... More
S&F in replacement of Power / Control Copper Cables, with solid copper conductor, XLPE insulated, 2.5 sqmm, 6 core cut to pieces including making all necessary connections as per site requirement and removing the old unsericeable control cables from ducts etc complete all as specified and directed.

120

-

-

... More
S&F in replacement of Power / Control Copper Cables, with solid copper conductor, XLPE insulated, 2.5 sqmm, 8 core cut to pieces including making all necessary connections as per site requirement and removing the old unserviceable control cables from ducts etc complete all as specified and directed.

120

-

-

... More
Dismantling & taking down old, deteriorated, switch air break and S &F with new 33 kV Isolator Double Stack , Horizontal Type, 400 Amp, each pole consist of galvanised steel base, H.T. insulators as per IS, non ferrous knife and spring loaded contact, arcing horns of adequate section to break the magnetizing current, including horizontal G.I. pipe adequate length for phase separation, adequate length of G.I. pipe of 32 mm for operation from ground level and operating handle in both OFF and ON position, jumpers with suitable conductor line, taps, clamps, colour coated HT sleeves and fittings suitable for horizontally mounting, complete all as specified and directed.

2

-

-

... More
S&F in repair Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as required gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over and including a coat of red oxide zinc chromate primer on exposed steel surfaces after preparation of surfaces complete all as specified and directed. (Note: - (i) Sizes & types of members and shape of the cross arms etc shall be as required at site all as directed by the Engineer-in-Charge. (ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only. Cost of the same is included in unit rate of the item and nothing shall be extra paid on this account.) Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel')

400

-

-

... More
S&F in replacement of Lightning arresters expulsion type with all fittings, transmission class, discharge capacity 65 Kilo amps suitable for 33000 Volts including brackets, clamps, nuts, washers and connecting to 32 x 6 mm GI strip complete all as specified and directed.

3

-

-

... More
M&L for Calibration and testing of 33 KV Control and Relay Panel, to ensure physical healthiness with visual check for healthy tripping of over current and earth fault, adjusting tripping time, flag setting, ratio setting, instantaneous time setting etc as per installed capacity of transformer, short circuit current in accordance with percentage impedance of transformer including taking out the unserviceable parts / relays and making necessary alteration for fixing of the same in the existing panel complete all as specified and directed. Note:- (i) All the instruments and T & P required for the above jobs shall be arranged by the contractor at site and cost of the deemed to be included in the quoted rates. (ii) The all above checking ,inspection ,installation and testing work shall be performed by auth HT expert engineer. (iii) Spares and relays required for proper functioning of the system will be measured and paid seperately. (iv) Any other items necessary required for functioning of panel deemed to be including in quoted rate.

3

-

-

... More
S&F Numerical Over Current Protection Relay, draw out type for 33 KV control panel complete all as specified and directed.

2

-

-

... More
S&F Master Trip Relay, draw out type for 33 KV control panel complete all as specified and directed.

2

-

-

... More
S&F Oil temperature and Winding temperature Relay for 33 KV control panel complete all as specified and directed.

3

-

-

... More
S&F Buchholz Relay for 33 KV control panel complete all as specified and directed.

2

-

-

... More
S&F PRV Relay for 33 KV control panel complete all as specified and directed.

2

-

-

... More
S&F Auxillary Relay for 33 KV control panel complete all as specified and directed.

3

-

-

... More
Servicing / Calibration to 33 / 11 KV HT VCB / SF-6/LBS/RMU including the following (a) Taking out 33 / 11 KV HT VCB / LBS/RMU of 400 /800 Amps rating trolley from HT Panel after switching off electric supply. checking of mechanical system for proper functioning of upward / downward movement of HT VCB / SF6 trolley including opening the VCB / SF6 & checking the mechanical system. cleaning & servicing the fixed / moving contact & blowing out dust and applying the proper lubrication / greasing and reassembling the VCB / SF6 including connection to HT panel complete insulating oil to be replaced where required complete all as specified and directed. (b) Taking out relay set of any make from HT 33 / 11 KV VCB / SF6 panel and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibrate the relay by relay testing kit & proper plug setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed. Note for (a) & (b):- (i) Replacing new items shall be measured and paid separately as supply only. Note : Minor spares if required shall deems to be included with the above job.

6

-

-

... More
Supply only shunt trip coil assembly suitable for HT, SF6 / VCB, operating on 30 / 110 volt system and testing complete all as specified and directed.

6

-

-

... More
Supply and fixing closing / tripping coil operated on 110 / 30 volt system suitable for working of relay of HT SF6 / VCB complete all as specified and directed.

4

-

-

... More
Supply and fixing only fabricated gears as required for spring charger of VCBs complete all as specified and directed.

4

-

-

... More
S&F in replacement of vaccum circuit bottle as per existing make complete all as specified and directed.

9

-

-

... More
S&F (in replacement) indication lamp (LED type) Red or Yellow or Green colour suitable for 110 volts AC / 110 volt DC / 30 volts DC (as required at site) complete all as specified and directed.

30

-

-

... More
S&F Female contact or fixed contact blade for 33 KV gang operated switch, heavy duty and high conductive metal of capacity 200 / 400 amp complete with all accessories all as specified and directed.

6

-

-

... More
S&F in replacement of MC 61 A Relay for 33 KV control panel complete all as specified & directed.

1

-

-

... More
S&F Male contact or moving contact blade for 33 KV gang operated switch, heavy duty and high conductive metal of capacity 200/400 amp complete with all accessories all as specified and directed.

8

-

-

... More
S&F Tinned copper flexible jumper 200/400 amp for 33 KV gang operated switch complete all as specified and directed.

8

-

-

... More
S&F Fix top / bottom contact suitable for 33 KV drop out fuse complete all as specified and directed.

6

-

-

... More
S&F in replacement of aluminium Tee clamps heavy duty suitable for panther/dog conductor at 33 KV sub station bus bar including disconnecting and dismantling old complete all as specified and directed.

6

-

-

... More
S&F in replacement of aluminium Pad connector heavy duty suitable for panther/dog conductor at 33 KV sub station bus bar including disconnecting and dismantling old complete all as specified and directed.

6

-

-

... More
S&F in replacement of aluminium PG clamps heavy duty suitable for panther/dog conductor at 33 KV sub station bus bar including disconnecting and dismantling old complete all as specified and directed.

6

-

-

... More
S&F in replacement of aluminium Universal connector heavy duty suitable for panther/dog conductor at 33 KV sub station bus bar including disconnecting and dismantling old complete all as specified and directed.

6

-

-

... More
S&F in replacement of aluminium Compression type connector stud type heavy duty terminal suitable for panther/dog conductor at 33 KV sub station bus bar including disconnecting and dismantling old complete all as specified and directed.

6

-

-

... More
S&F in replacement of four in series disc type insulator porcelain vitreous with all accessories, brown colour for working pressure 33 KV including dismantling old complete all as specified and directed.

6

-

-

... More
S&F in replacement of dropout fuse unit with double stack post insulators and channel, nut, bolt and washers etc all as required at site for 33 KV sub station including dismantling old complete all as specified and directed.

2

-

-

... More
S&F in replacement of pin type insulator porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut of 260mm height, 290mm dia for 33 KV electric pressure including dismantling old complete all as specified and directed.

6

-

-

... More
Unbinding from insulators ACSR conductor any size of HT 33 KV sub station for repairs. Re-stretching of ACSR conductor to achieve proper sag and rewinding to the insulators using proper connectors/clamp and making all existing cable connections complete all as specified and directed.

100

-

-

... More
Dismantaling top cover of transformer 33/11 KV of capacity 2/3.15 MVA, any make for repair, replacement of HT/LT bushing or for replacement of top cover gasket or for inspection of transformer body by taking out core of transformer 33/11 KV of capacity 2/3.15 MVA and testing on completion etc all as specified and directed for minor internal repairs of transformer and drain out carefully transformer oil as required / upto the required level and refilling the same and refitting the top cover of transformer after completion of the work to the entire satisfaction of engineer-in-charge.

2

-

-

... More
Material and labour for drain out transformer oil from the transformer of capacity 2/3.15 MVA out door in a clean barrel and disconnection of internal electrical connection by taking out the top cover cleaning of tank, removal of sludge, scrapping existing paint coat and applying chemical based painting etc complete all as specified and directed. Note : The rate deemed to be included of all tools and plants.

2

-

-

... More
Material and labour for dismantling of HV/LV coils of transformer of capacity 2.0 /3.15 MVA (33/11/6.6 KV) and segregating, serviceable and unserviceable coils, serviceable coils shall kept aside for reuse after complete varnishing and testing of each coil including removal of complete core and accessories such as HV / LV bushings with metal parts, oil temp indicator ,winding temp indicator and disconnection of OTI, WTI complete all as specified and directed. Note : 1. Rewinding of defective HV / LV Coils shall be measured and paid seperately. 2. The rate deemed to be included of all tools and plants.

2

-

-

... More
Material and labour for assembling ,yoke fitting, assembling of LV coils in completely intact position over the CRGO laminated core, the HT coils shall be fixed over the LV coils by providing the insulation barriers and make the assembly in intact position (insulation material & CRGO laminated core shall be measured and paid separately) including assembling of core on mounting channel for the transformer of capacity 2.0 /3.15 MVA (33/11/6.6 kv) complete all as specified and directed.

2

-

-

... More
M&L for connecting all the internal connection, soldering, brazing of HV/LV connections by silver electrodes including replacement of leads by providing tubular insulation of tap changer assembly and its connections and taking of assembly in tank with suitable locking arrangements and re-fixing the top cover of transformer including the other accessories such as ,OTI,WTI , and connecting with protection system and making the transformer absolute leak proof for 2.0 MVA (33/11/6.6 KV) transformer all as specified and directed by Engineer-in-Charge. Note- The windings and connections of all transformers shall be braced to withstand shocks which may occur during transport or due to switching and other transport condition during service. Coil clamping rings, if provided same shall be of steel. Any metal pieces in contact with laminated rings shall be designed and secured that they do not weaken the electrical or the mechanical properties of the rings. If the transformer winding is built up of section of disc coils, separated by spacers, the clamping arrangements shall be such that equal pressure are applied to all columns of spacers. All such spacers shall be securely located, shall be of suitable material and shall receive adequate shrinkage treatment before assembly.

2

-

-

... More
M&L for cleaning the conservator assembly & cooling fins by removing sludge clogging material with the help of air blast including re-fixing of conservator & cooling fins in original position with nuts, bolts washer, for 2.0/3.15 MVA transformer complete all as specified and directed.

2

-

-

... More
Dismantling and taking down breather assembly for 2/3.15 MVA capacity and replacement of breather to the transformer filling with fresh Silica Jel complete all as specified and directed.

2

-

-

... More
S/F cork sheet gaskit cut to shape for the top covers, radiator valves, conservator assembly bucolz and other required places of the transformer of capacity 2.0 MVA 33/11/6.6 KV complete all as specified and directed.

2

-

-

... More
Material and labour for opening of assembly including HV/LV coils of transformer 2.0 MVA in oven for at least 72 Hrs for achieving desired insulation value and removal of assembly (Note if the desired result was not found re-opening shall be done without any extra cost of govt) complete all as specified and directed.

2

-

-

... More
Supply and fixing insulation material PCB electrical grade such as barriers, coil to coil insulation block & rings insulation cylinders, ebonite sleeves etc for 2 MVA transformer complete all as specified and directed.

250

-

-

... More
S&F in replacement of Marshelling box (as per existing size at site) of 2 MVA Transformer including disconnecting & dismantling the existing control wiring and Oil Temperature Indicator (OTI) & Winding Temperature Indicator (WTI) and reconnect all the control wiring with OTI & WTI and testing complete all as specified and directed.

2

-

-

... More
S&F in replacement of Oil Temperature Indicator (OTI) for Power Transformer 33/11/6.6 KV with all connected accessories all as specified and directed

2

-

-

... More
S&F in replacement of Winding Temperature Indicator (WTI) for Power Transformer 33/11/6.6 KV with all connected accessories all as specified and directed

2

-

-

... More
Dismantling old u/s HT 33/11/6.6 KV bushes and fixing in replacement of HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock, rubber seals and insulators suitable for transformer of capacity 2.0/3.15 MVA complete all as specified and directed.

12

-

-

... More
M&L for Open the cover of transformer 2.0/3.15 KVA and filling in with new transformer oil low viscosity as per IS-335 of 1992 including heating of oil and die-electric strength 60 KV when tested at 4mm gap complete all as specified and directed.

3000

-

-

... More
M&L Installation, commissioning, testing of 2/3.15 MVA transformer by connecting all HT 33/11/6.6 KV connections, earthing connections, control cables for various protections, indications, metering, connection and bezels connections and testing complete all as specified and directed.

2

-

-

... More
M&L for cleaning of surface of transformer of capacity 2.0/3.15 MVA by scrapping out old paint and painting of transformer by two coats of synthetic enamel gray paint externally including writing of SM/MES No on the transformer complete all as specified and directed.

2

-

-

... More
Dismantling old u/s HT 33 KV bushes and fixing in replacement of HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity up to 2 MVA not exceeding 3.15 MVA 33/11/6.6 KV complete all as specified and directed.

6

-

-

... More
Dismantling old u/s LT bushes and fixing in replacement of LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, locknuts and rubber seal for indoor/outdoor transformer of capacity 2 MVA but not exceeding 3.15 MVA. 33/11/6.6 KV on LV side complete all as specified and directed.

6

-

-

... More
Repairs to the leaks of transformer from tap switch/ fins/ any pats of body, by replacing gasket / seal, or Repairs to the leaks of transformer body / fins, by welding / brazing etc complete all as specified and directed.

3

-

-

... More
Disconnecting electrically, open the cover of transformer any type/size and filteration and dehydration of Transformer oil for 33/11/6.6/0.433 KV transformers, with stream line mobile filtration plant (To be provided by contractor & quoted prices deemed to included its hire charges) at a temp from 60-75 degree celsius to achieve the dielectric strength of oil 60 KV or over at standard gap as per IS 335 of 1993 (Fourth revision) to remove the moisture from winding and core complete all as specified and directed. Note : (a) Filtration should be carried out in OFF position, therefore generator and cables will have to be arranged by the contractor at his own cost. (b) Test result will be recorded before and after filtration of oil and submitted to Engr-in-Charge in a prescribed manner.

4500

-

-

... More
M&L for earthing with GI plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable and making test point and all connections complete all as specified and directed.

10

-

-

... More
Removal of unwanted vegetation/bushes/small plants/ shrubs complete inside/outside the installations all around and surface excavation not exceeding 15 cm depth levelling the ground and removing the excavated material to a distance exceeding 50 Mtr complete all as specified and directed.

2

-

-

... More
Removing the cover of cable duct for removal of unwanted vegetation/bushes/small plants/ shrubs/soil from cable duct not exc 3' wide and 3' deep at 33 KV sub station and removing the excavated material to a distance exceeding 50 M and placing the cover after completion complete all as specified and directed.

80

-

-

... More
Removal coarse aggregate of any size from MES installation and segregate/removal of vegetation/ bushes/ small plants/ shrubs etc and after that spreading in the same location including levelling and removing the vegetation/ bushes/ small plants/ shrubs to a distance exceeding 50 M all as spfd and directed.

2

-

-

... More
M&L for coarse aggregate not less than 40 mm graded nominal size without any vegetation or chemical including levelling spreading all around complete all as spfd & directed.

90

-

-

... More
M&L for taking out old burnt winding of on load tap changer and rewinding of coil of any type, capacity and with approved quality supper enamelled copper wire/ strip of approved make of suitable gauge and number of turns along with allied materials like cork sheet, fibre glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc. complete all as specified and directed.

100

-

-

... More
Material and labour for dismantling of HV/LV coils of transformer upto 750 KVA (33/11/6.6/0.433 KV) and segregating, serviceable and unserviceable coils, serviceable coils shall kept aside for reuse after complete varnishing and testing of each coil including removal of complete core and accessories such as HV/LV bushings with metal parts, oil temp indicator ,winding temp indicator and disconnection of OTI, WTI complete all as specified and directed. Note:- quoted rate deemed to be included of all tools and plants.

2

-

-

... More
M&L Installation, commissioning, testing for transformer up to 750 KVA by connecting all HT 33/11/6.6/0.433 KV connections, earthing connections, control cables for various protections, indications, metering, connection and bezels connections and testing complete all as specified and directed.

2

-

-

... More
M&L for painting of HT 33 KV incomming and outgoing feeder bus bar made out of cross arms i.e MS/steel/flat channels/pipes at 33 KV yard without removing accessories with two coat of aluminium paint top to bottom after scratching old paint complete all as specified and directed.

4

-

-

... More
S&F in replacement of fully retroreflective sign boards of cut to sizes/shape having writing back ground made out of 18 SWG MS Sheet including marking/writing letters, road sign any type with radium tape in different colours, duly mounted on angle iron frame of size 45mm X 45mm and 5mm thick fixed with nut, bolt, washer and welding (height as per site requirement) etc and painting with two coats of black synthetic enamel paint over and including a coat primer and all necessary earth work and PCC for foundation complete all as specified and directed.

1

-

-

... More
M&L for painting of steel tubular pole up to 11 mtr height including cross arms without removing accessories with two coat of aluminium paint top to bottom after scratching old paint including making pole numbers in a 20 cm dia yellow circle with number writing with black synthetic paint and painting alternative yellow and black strips of 30 cm each upto 1.5 mtr height from ground level using fluorescent paint including one coat of snowcem on PCC coping of pole complete all as specified and directed.

6

-

-

... More
Disconnecting of HT supply from APFC panel any type and size and maintenance & servicing of capacitor bank panel of any capacity including cleaning of all contacts, decarbonising of contactor contacts with petrol/CRC, checking & tightening of all cable/ bus bar connection, CT connections & replacement of worn out parts such as capacitors, capacitor lugs, MOC, CT's, indicators, Rotary switches, APFC relays, fuses & measuring meters etc including setting of power factor 0.98 to 0.99 and testing after repair complete all as specified and directed. Note- Spare Parts replaced of APFC panel shall be measured and paid separately under relevant item of BOQ.

5

-

-

... More
M&L in replacement of MPP heavy duty capacitor bank cylindrical type, 3 phase 11/6.6 KV of capacity 100 KVAR including necessary copper lead copper lugs of suitable size complete all as specified and directed.

4

-

-

... More
All as per Item No 82 above but capacity 200 KVAR complete all as specified and directed.

4

-

-

... More
S&F in replacement of 3 pole Capacitor duty Contactor type MOC suitable for upto 100 KVAR capacitor comprising of built-in-auxiliary contacts, 50 Hz AC rating 415 volts in existing LT panel complete all as specified and directed.

2

-

-

... More
All as per Item No 84 above but for 200 KVAR capacitor complete all as specified and directed.

2

-

-

... More
S&F in replacement switch disconnector fuse with HRC fuse 100 Amps 4 pole 415 V ,panel mouting type without enclosure, including labour for alterration in panel etc complete all as specified and directed.

8

-

-

... More
All as per Item No 86 above but of rating 250 Amps complete all as specified and directed.

4

-

-

... More
All as per Item No 86 above but of rating 400 Amps complete all as specified and directed.

4

-

-

... More
M&L in replacement of Dry type , Air cored Aluminium wound , series reactor at rated voltage 11/6.6 KV , 50 Hz rated output of .008 kVAr rated current 9.62 Amp having rated short time symmetrical RMS current of 16.6 times of rated current for 2 sec complete all as specified & directed.

2

-

-

... More
S&F in replacement of indoor type Current transformer (CTs) 11/6/6 KV of ratio 65/5-5 class-1 for metering, class 5 P 10 for protection 15 VA burden suitable 500 kVAr auto switched capacitor panel insulation class B complete all as specified & directed.

1

-

-

... More
S&F in replacement of indoor type Potential transformer (PTs) 11/6/6 KV of ratio 110/110 volt class-1 for metering, class 3 P 10 for protection 50 VA burden suitable 500 kVAr auto switched capacitor panel insulation class B complete all as specified & directed.

1

-

-

... More
S&F Control voltage transformer Indoor type suitable for 500 kVAr auto switched capacitor panel having rated system voltage 11/6.6 KV ratio 11/6.6 KV/230 volt accuracy class 6P rated buirden 2000 VA 2 phase complete all as specified & directed.

2

-

-

... More
M&L in replacement of Air termination, single pointed aluminium rod 12 mm dia 300 mm long complete all as specified & directed.

15

-

-

... More
M&L in replacement of test point terminal block made of gun metal or phosphorus bronze of size 75x 75x 25 drilled and screwed including 3 nos hexagonal head screw complete all as specified & directed.

2

-

-

... More
M&L in replacement of Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified & directed.

40

-

-

... More
M&L in replacement of Galvanised iron strip 32x6 mm buried in ground for necessary connection complete all as specified & directed.

40

-

-

... More
S&F in replacement of Current transformer (CTs) 33 KV outdoor type oil filled of ratio 70-30/5+5 class-1 for metering, class 5 P 10 for protection 15 VA burden suitable for protection metering and deferential protection mounted on extended frame of VCB and made up of hot dip galvanized steel structure. All control cables shall be terminated in junction box. Note :- (i). Cost of junction box and frame work used for CTs is deemed to be included in the rate quoted. (ii). Double core CT shall be provided one for protection (earth fault/over load) and one for measuring instruments.

1

-

-

... More
S&F in replacement of Current transformer (CTs) 33 KV outdoor type oil filled of ratio 100-30/5+5 class-1 for metering, class 5 P 10 for protection 15 VA burden suitable for protection metering and deferential protection mounted on extended frame of VCB and made up of hot dip galvanized steel structure. All control cables shall be terminated in junction box. Note :- (i). Cost of junction box and frame work used for CTs is deemed to be included in the rate quoted. (ii). Double core CT shall be provided one for protection (earth fault/over load) and one for measuring instruments.

1

-

-

... More
S&F in replacement of single phase potential transformer (PTs) oil filled type of ratio 33KV/110 volts, class-1 suitable burden and mounted on hot dip galvanized steel structure, all control cables shall be terminated in junction box. Note : (i) Cost of junction box and frame work used for PTs is deemed to be included in the rate quoted.

1

-

-

... More
S&F in replacement of battery bank consisting of 15 battery having cell capacity 100 Ah 2 volt complete all as specified & directed.

2

-

-

... More
Detection of any type of fault in HT underground Line (laid in soil at plane area or forest area) with the help of Cable fault locator machine. Cable fault locator with carring vehicle will be brought by the cable fault detection agencies. Span of faulty cable will be trace out by the agencies by meggering HT cable. Note : 1. Detection of fault in one span of length will be measured as one Job either machine placed from one side or both side of the cable. 2. Technicians will be employed by the working agencies. 3. Earth work and taking out will be measured and paid seperately. 4. Material for repair and replacement measured and paid saperately. 5. One job shall be measured if the fault has successfully identified by the fault locator machine or removing moisture in the cable if required.

6

-

-

... More
Supply & laying rubber insulating mats of 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS :15652-2006 suitable for electrical shock safety of sizes 2x 1m complete all as specified & directed.

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.