Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date21 Dec 2024
Closing Date18 Jan 2025
Tender Amount₹ 70,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for dismantling of burnt capacitor and Supply & Fix capacitor of capacity 36 Mfd in plastic/ metal container complete all as directed by EIC.

90

-

-

... More
M&L for dismantling of burnt capacitor and Supply & Fix capacitor of capacity 50+5Mfd in plastic/ metal container complete all as directed by EIC.

180

-

-

... More
M&L for dismantling of burnt capacitor and Supply & Fix capacitor of capacity 45 Mfd in plastic/ metal container complete all as directed by EIC.

150

-

-

... More
M&L for dismantling of burnt Indoor unit Censor and Supply & Fix Censor (in each set) of Indoor unit Split AC Inverter type (Cooling / Hot and cold type) of any make and model for 1.5 TR / 2 TR capacities completed all as directed by EIC.

5

-

-

... More
M&L for dismantling of burnt Outdoor unit Censor and Supply & Fix Censor (in each set) of Outdoor unit Split AC Inverter type (Cooling / Hot and cold type) of any make and model for 1.5 TR / 2 TR capacities completed all as directed by EIC

5

-

-

... More
M&L for dismantling of burnt Swing motor and Supply & Fix Swing motor for 1.5 TR / 2 TR indoor unit of split AC all as directed by EIC.

8

-

-

... More
M&L for dismantling of burnt Swing motor and Supply & Fix Swing motor for 1.5 TR / 2 TR indoor unit of split AC Inverter type (cooling only / hot & cold type) all as directed by EIC.

6

-

-

... More
M&L for dismantling of burnt Swing motor and Supply & Fix Swing motor for 1.5 TR / 2 TR window AC all as directed by EIC.

2

-

-

... More
M&L for dismantling of defected brass suction valve and Supply & fix brass suction valve size 3/8" complete all as specified and directed

5

-

-

... More
M&L for dismantling of defected Discharge valve and Supply & fix Discharge valve size 1/2" complete all as specified and directed .

6

-

-

... More
M&L for dismantling of defected charging valve and Supply & fix charging valve size 1/4" complete all as per directed by EIC

6

-

-

... More
M&L for dismantling of defected flare nuts and Supply & fix flare nuts size 3/8" complete all as specified and directed

5

-

-

... More
M&L for dismantling of defected flare nuts and Supply & fix flare nuts size 1/4"complete all as specified and directed

30

-

-

... More
M&L for dismantling of defected flare nuts and Supply & fix flare nuts size 1/2" complete all as specified and directed

30

-

-

... More
M&L for dismantling of defected flare nuts and Supply & fix flare nuts size 5/8" complete all as specified and directed

6

-

-

... More
M&L for dismantling of defected copper gas filter and Supply & fix copper Gas filter for AC 1.5 TR / 2 TR capacity all as specified and directed

6

-

-

... More
M&L for dismantling of burnt connector and Supply & fix connector suitbale for any type AC of any make , model and capacity complete all as specified and directed by Engineer-in- Charge.

8

-

-

... More
M&L for renew PVC insulated three core stranded copper cable of size 80/0.20 ( 2.5 sqmm) all as specified and directed .

430

-

-

... More
M&L for renew MCB SP -6 to 32 Amps rating to be housed in DBs catered here in after complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating):-

10

-

-

... More
M&L for renew Mettalic Plugs ( top) of AC box 20A, specified make , 2P+E and connecting all as specified and directed

80

-

-

... More
M&L for repair/ renew copper capillary of size 0.60 mm complete all as specified and directed

6

-

-

... More
S&F in repair plug and socket DBs with single pole MCB rated 32 Amps capacity with socket plug top 2 pin and earth plug complete all as specified including making niche in wall and mounted flush complete all as specified

5

-

-

... More
M&L for copper tube leaked repaired of Tower AC, Split AC, Window AC of 1.5 TR/ 2.0TR capacity any make and model at any location of cantt area after repaired of tube by brazing, testing of leakage, vaccumnisation and charging full/ top up of refrigerant (R-22/R-32/R-410) required to make it fully functional complete all as directed by EIC. Note :- Refrigerant gas will be provided by Contractor

150

-

-

... More
Supply only of puff insulation of size1/2" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC

180

-

-

... More
Supply only of puff insulation of size1/4" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC

180

-

-

... More
Supply only of puff insulation of size5/8" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC

120

-

-

... More
Supply and fix PVC pipe nylon imbraided 15 mm dia for condensed water drain fitted with clamps/concealed in wall all as specified and directed.

470

-

-

... More
Supply and fix in repair of copper tubing 3/8"dia with puff insulation complete all as specified and directed .

20

-

-

... More
Supply and fix in repair of copper tubing 1/2" dia with puff insulation complete all as specified and directed .

270

-

-

... More
Supply and fix in repair of copper tubing 1/4" dia with puff insulation complete all as specified and directed .

270

-

-

... More
Dismantling of defective indoor unit of 2.0 TR capacity split type AC and supply & fixing new indoor unit Inverter type (hot & cold) type of the same capacity with blower, motor, front grill, Remote hand set with pencil cell, flexible cable and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit in wall/ceiling mounted all as specified and directed.

15

-

-

... More
Supply and fix remote hand set of Window/ Split type air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed

20

-

-

... More
Supply and fix remote hand set of Inverter type Split air conditioner (hot & cold type) of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed

12

-

-

... More
Supply and fix in repair Air Censor for temperature control for 1.5 TR/ 2.0 TR Split AC/ Tower AC/ Window AC complete all as specified and directed.

6

-

-

... More
Supply and fix PVC fan blade with gun metal bush of blower , Screw complete as per complete all as directed by EIC

30

-

-

... More
Supply and fix PVC blower for window A.C. as per sample complete all as specified and directed

20

-

-

... More
M&L for taking down of Split type AC (Indoor & outdoor complete) of any capacity or model and transporting and refixing at New Location to make it fully functional again at new location with all as specified and directed by Engr-In -Charge.

60

-

-

... More
M&L for taking down of Window AC any capacity or model, transporting and refixing at New Location to make it fully functional again all as specified and directed by Engr-In -Charge.

18

-

-

... More
Taking out defective blower motor from any type AC and transporting from site to contractor workshop dismantling the burnt winding & rewinding with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting back to site and refixing complete all as specified and directed.

40

-

-

... More
Dismantling of burnt blower motor of 1.5 TR/2.0 TR split AC ( indoor unit) and supply & fixing new blower motor Suitable for any make ACs as per sample complete all as specified and directed.

30

-

-

... More
Dismantling of burnt outdoor fan motor of 1.5 TR/2.0TR split AC (outdoor unit) and supply & fixing new outdoor fan motor Suitable for any make ACs as per sample complete all as specified and directed.

30

-

-

... More
Dismantling of defective indoor unit of 2.0 TR capacity Tower AC and supply & fixing new indoor unit Tower AC of the same capacity with blower motor, front grill, Remote hand set with pencil cell, flexible cable and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit all as specified and directed.

2

-

-

... More
Dismantling of existing window type AC. from its location and refixing after doing by Servicing by oiling and water with pressure jet complete all as directed by EIC.

80

-

-

... More
M&L for painting of outer cage and front grill of window type AC or indoor unit & outdoor unit of Split type AC or Tower AC of any make & capacity with two coats of synthetic enameled paint of approved shade and tint including preparation of steel surface by emery paper including writing SM No. / MES No. etc complete all as directed by EIC

4

-

-

... More
Taking down outdoor unit of Tower Ac/ split AC any make/ model/ capacity and transporting from site to contractor workshop for carrying out repairs and renewal/ replacements of Parts including servicing and liquid soap washing, after repaired the same, transporting back to site, required to make it fully functional reassemble and installation on existing same location with complete all as specified and directed.(Note :- M&L for parts renew/ replacements shall be measured and paid separately under appropriate item(s)

30

-

-

... More
M&L for Water dropping leaked repaired of Tower AC, Split AC, Window AC of any make, model and capacity by AC mechanic at any location of cantt area with complete all as directed by EIC

70

-

-

... More
M&L for convert to heating/ cooling mode (only reverse cycle connection) in Split AC, Window AC of any make, model and capacity by AC mechanic at any location of cantt area with complete all as directed by EIC

70

-

-

... More
M&L for Renewal of plywood 6 mm thick,BWR, grade 1, one side decorative teak veneers and other side commercial veneered finished to cover space of window or wall for fix of window AC any capacity to complete as directed by EIC

10

-

-

... More
M&L for Renewal of 2nd class HW (SAL) fillets, cross sectional area excd 2" x 2" on all four sides of window type AC splayed or chamfered edge including polishing etc complete all as specified and directed.

15

-

-

... More
Dismantling of defective indoor unit of 1.5 TR capacity split type AC and supply & fixing new indoor unit Inverter type (hot & cold) type of the same capacity with blower motor, front grill, Remote hand set with pencil cell, flexible cable and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit in wall/ceiling mounted all as specified and directed.

55

-

-

... More
Dismantling of defective cooling coil of 1.5 TR/2.0 TR window type AC of any make and S&F cooling coil in copper by brazing, leak proove and vaccumination complete all as specified and directed

1

-

-

... More
Dismantling of defective condencing coil of 1.5 TR/2.0 TR window type AC of any make and S&F condencing coil in copper by brazing, leak proove and vaccumination complete all as specified and directed

2

-

-

... More
Dismantling of defective cooling coil of 1.5 TR/2.0TR Split AC of any make and S&F cooling coil in copper by brazing, leak proove and vaccumination complete all as specified and directed

1

-

-

... More
Dismantling of defective condencing coil of 1.5 TR/2.0TR Split AC of any make and S&F condencing coil in copper by brazing, leak proove and vaccumination complete all as specified and directed

2

-

-

... More
Dismantling of burnt fan motor of 1.5 TR/2.0TR window AC double shaft and supply & fixing new fan motor Suitable for ny make ACs as per sample complete all as specified and directed.

12

-

-

... More
Dismantling of unserviceable compressors of 1.5 TR capacities including disconnecting suction / discharge copper tubing and S&F new compressor rotary type copper winding with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii) The electrical accessories required will be measured and paid for separately.

28

-

-

... More
Dismantling of unserviceable compressors of 2 TR capacities including disconnecting suction / discharge copper tubing and S&F new compressor rotary type copper winding with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii) The electrical accessories required will be measured and paid for separately.

8

-

-

... More
Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 2.0 TR capacity and supply & fixing new condensing unit (outdoor unit) Inverter type (hot & cold) of the same capacity complete with compressor, copper condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with blade and including copper tube with puff insulation of suction and discharge suitable size complete all as directed.

15

-

-

... More
Dismantling of defective Voltage Stablizer and supply & fixing new Voltage Stablizer of 5 KVA capacity complete with copper winding power transformer, automatic boost/ buck transformer for low and high voltage with electronic transistorised relay/ time relay for two min , SP, 50 Hz with volt meter indicator digital type and input voltage 140 to 280 and cut up voltage 215 to 240 V all as specified.

65

-

-

... More
Supply and fixing in repairs front grill quality for window AC of 1.5 TR/ 2 TR of all as specified and directed

6

-

-

... More
M&L for fabrication of Tray for Window AC made out of 24 SWG 10mm aperture including rivetting brazing /soldering including painting with two coat of (black) enameled paint over a coat of red oxide primer and installed at locations complete all as specified and directed.

12

-

-

... More
Dismantling of defective condensing unit ( outdoor unit) of Tower AC of 2.0 TR capacity and supply & fixing new condensing unit (outdoor unit) of Tower AC 2.0 TR capacity complete with compressor, Copper condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with blade and including copper tube with puff insulation of suction and discharge suitable size complete all as directed .

2

-

-

... More
M & L for servicing of Split AC/ tower AC/ Cassette AC 1.5/2.0/3.0/4.0 TR Indoor & out door unit by water pressurejet & jacket ,cleaning & washing of cooling/condencing coil by soap solution or recommended chemical ,oiling & greasing of moving parts such as blower motor etc complete all as specified and directed by EIC.

360

-

-

... More
M & L for Nitrogen pressure testing,flushing out the system by Nitrogen ,vacumination and charging/ topup of refrigerant gas R-22/R-32/R-410 into the system for any type AC and any capacity all as specified and directed. (The refrigerant gas will be provided by Contractor)

2

-

-

... More
M&L for copper tube leaked repaired of Cassette AC of 3 TR/ 4TR capacity any make and model at any location of cantt area after repaired of tube by brazing, testing of leakage, vaccumnisation and charging of refrigerant (R-22/R-32/R-410) required to make it fully functional complete all as directed by EIC. Note :- Refrigerant gas will be provided by Contractor

2

-

-

... More
Supply & Charging by Top up of refrigerant in the AC unit of 1.5 TR / 2 TR split AC/ window AC/ Tower AC unit with refrigerant gas R-22/R-32/R-410 in required Qty complete all as specified and directed (The refrigerant gas will be provided by Contractor)

410

-

-

... More
Supply & fix New display suitable for Split AC/ window AC/ Tower AC of any make/ model & capacity complete all as directed by EIC

5

-

-

... More
Supply & fix New display suitable for Inverter Split AC (cooling or Hot & cold type) of any make/ model & capacity complete all as directed by EIC

5

-

-

... More
M&L for dismantling of defective display of 1.5/2.0 TR capacity Split AC/ Window AC of any make and transporting to contractors workshop for repair of the same,transporting back to site & refixing to ensure proper functioning of the AC complete all as specified and directed.

10

-

-

... More
Dismantling of burnt blower motor of 1.5 TR/2.0 TR split AC ( indoor unit) Inverter Split AC and supply & fixing new blower motor of Inverter Split AC (Cooling or hot & cold type) Suitable for any make ACs as per sample complete all as specified and directed.

20

-

-

... More
Dismantling of burnt outdoor fan motor of 1.5 TR/2.0 TR split AC ( outdoor unit) Inverter Split AC and supply & fixing new outdoor fan motor of Inverter Split AC (Cooling or hot & cold type) Suitable for any make ACs as per sample complete all as specified and directed.

20

-

-

... More
S&F reverse cycle solenoid valve in split type AC 1.5 / 2 TR capacity with necessary extension to suction/ discharge copper tubing & toggle switch complete all as specified and directed by Engineer-in- Charge.

2

-

-

... More
Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 1.5 TR capacity and supply & fixing new condensing unit (outdoor unit) Inverter type (hot & cold) of the same capacity complete with compressor, copper condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with blade and including copper tube with puff insulation of suction and discharge suitable size complete all as directed.

55

-

-

... More
S&F in replacement New PCB for indoor unit of any make of Cap 1.5/2.0 TR Split AC complete all as specified and directed.

18

-

-

... More
M&L for dismantling of defective PCB of 1.5/2.0 TR capacity Split AC/ Window AC of any make from indoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed.

60

-

-

... More
Dismantling of window AC and supply & fixing new window AC Non-Inverter type of 1.5 TR capacity complete with compressor, copper condensing coil and cooling coil, wiring kit, grill, cage, motor with blade and blower suitable size complete all as directed.

8

-

-

... More
S&F in replacement New PCB for window AC of Cap 1.5/2.0 TR of any make/ model complete all as specified and directed.

2

-

-

... More
S&F in replacement New PCB for indoor unit with all censor set of any make of Cap 1.5/2.0 TR Split AC Inverter type( cooling only/ hot & cold) complete all as specified and directed.

8

-

-

... More
S&F in replacement New PCB for Outdoor unit with all censor set of any make of Cap 1.5/2.0 TR Split AC Inverter type( cooling only/ hot & cold) complete all as specified and directed.

8

-

-

... More
M&L for dismantling of defective PCB of 1.5/2.0 TR capacity SplitAC inverter type (cooling only/ hot & cold) of any make from indoor or outdoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed.

30

-

-

... More
M&L for dismantling of burnt capacitor and Supply & Fix capacitor of capacity 2.5 Mfd in plastic container complete all as directed by EIC.

30

-

-

... More
M&L for dismantling of burnt capacitor and Supply & Fix capacitor of capacity 4/ 6 Mfd in plastic container complete all as directed by EIC.

80

-

-

... More
Dismantling of unserviceable compressors of 3 TR capacities including disconnecting suction / discharge copper tubing and S&F new compressor scroll type copper winding with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii)The electrical accessories required will be measured and paid for separately.

1

-

-

... More
Dismantling of unserviceable compressors of 4 TR capacities including disconnecting suction / discharge copper tubing and S&F new compressor scroll type copper winding with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii)The electrical accessories required will be measured and paid for separately.

1

-

-

... More
Dismantling of unserviceable compressors inverter type of 1.5 TR capacities including disconnecting suction / discharge copper tubing and S&F new compressor rotary inverter type copper winding with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note : (i) Refrigerant gas will be provided by contractor (ii)The electrical accessories required will be measured and paid for separately.

11

-

-

... More
Supply and fix in repair Polycarbonate Plug top 3 pin 16 Amp complete all as specified and directed.

120

-

-

... More
M&L for taking down unserviceable voltage stablizers of any make of following capacities and dismantling the stablizers of any size for repair of the defective parts/spares & ressembling including repairs of any parts testing and after repair refixing the same at existing location complete all as specified and directed Note:- Spare parts measured and paid seprately

40

-

-

... More
Supply only relay 25/30 Amps 24 volts for 4 KVA/5KVA voltage stablizers complete all as specified and directed

10

-

-

... More
Supply only main PCB/ Relay PCB with high & low voltage cut off suitable for 4 KVA/5 KVA voltage stablizers of any make complete all as specified and directed

15

-

-

... More
Supply only 2 mtr long copper cable 3 core PVC insulated and sheathed 80/.20(2.5 Sqmm) size duly fitted with 3 pin top 20 Amps all as specified and directed

15

-

-

... More
Supply only power transfromers suitable for voltage stablizers of capacity 4/5 KVA all as specified and directed

15

-

-

... More
Supply only AC volt meter square/round type 0-300 volts suitable for 5/4 KVA single phase voltage stablizers complete all as specified and directed

8

-

-

... More
supply only dimmer type transfromer for 4KVA/5KVA Voltage stablizers all as specified and directed by EIC

8

-

-

... More
M&L for dismantling of burnt contactor and Supply & fix power contactor 3ph complete all as specified and directed by EIC.

2

-

-

... More
M&L for defective gurmut and Supply & Fix Gurmut suitable for any type AC complete all as directed by EIC.

20

-

-

... More
M&L for dismantling of defected Dead nuts and Supply & fix Dead nuts size 1/2" complete all as specified and directed

30

-

-

... More
M&L for dismantling of defected Dead nuts and Supply & fix Dead nuts size 1/4" complete all as specified and directed

30

-

-

... More
M&L for dismantling of defected Dead nuts and Supply & fix Dead nuts size 5/8" complete all as specified and directed

12

-

-

... More
M&L for dismantling of defected Dead nuts and Supply & fix Dead nuts size 3/8" complete all as specified and directed

12

-

-

... More
Supply and fix in repair of copper tubing 5/8"dia with puff insulation complete all as specified and directed .

20

-

-

... More
Supply and fix in repair of Pin Valve complete all as specified and directed .

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.