Military Engineer Services Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Eprocure
Opening Date11 Feb 2025
Closing Date19 Mar 2025
Tender Amount₹ 18,59,49,000
AI Insights
Technical
Technical
Financial
Class Of Bidder
... View More
Class 'SS' and category a(i)
Technical Capacity
... View More
The required prior work experience for the bidder includes satisfactorily completion of requisite value works with Central/State Government/ Central/ State PSUs/ AWHO/ AFNHB/ CGEWHO / DGMAP. Details of works completed and under progress in MES need to be submitted in a specific format. However, specific values or percentages of similar works completed are not mentioned. Annual turnover, bank solvency, and working capital requirements are given in Para 1.4 & 1.5 of Section 1 of MES Manual of Contracts 2020, but the exact amount and percentage of similar works completed are not provided.
Costs
EMD
₹ 12,55,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_696736_1Tender No
958127/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Sch ‘A’ Part II.
1
8166
-
... More
SCHEDULE A PART III (INTERNAL ELECTRIFICATIONS)
-
-
-
... More
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONS as listed in Sch ‘A’ Part III.
1
4258680
-
... More
SCHEDULE A PART IV (EXTERNAL WATER SUPPLY)
-
-
-
... More
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Sch ‘A’ Part IV .
1
253261
-
... More
SCHEDULE A PART V (EXTERNAL ELECTRIFICATION)
-
-
-
... More
Lump sum price worked out by the contractor forEXTERNAL ELECTRIFICATION as listed in Sch ‘A’ Part V
1
1905639
-
... More
SCHEDULE A PART VI (SEWAGE DISPOSAL)
-
-
-
... More
Lump sum price worked out by the contractor for BSEWAGE DISPOSAL as listed in Sch ‘A’ Part VI
1
604796
-
... More
SCHEDULE A PART VII (AREA DRAINAGE)
-
-
-
... More
Lump sum price worked out by the contractor for BAREA DRAINAGE as listed in Sch ‘A’ Part VII
1
1078854
-
... More
SCHEDULE A PART- VIII (ROAD/PATH AND CULVERT)
-
-
-
... More
Lump sum price worked out by the contractor for ROAD/PATH AND CULVERT as listed in Sch ‘A’ Part VIII
1
8119492
-
... More
SCHEDULE A PART- IX (FENCING AND GATE)
-
-
-
... More
Lump sum price worked out by the contractor forCOMPOUND WALL, FENCING AND GATEas listed in Sch ‘A’ Part IX
1
845648
-
... More
SCHEDULE A PART- X (EARTHWORK AND SITE CLEARANCE)
-
-
-
... More
Lump sum price worked out by the contractor forEARTHWORK AND SITE CLEARANCE as listed in Sch ‘A’ Part X
1
1983639
-
... More
SCHEDULE A PART- XI (DEMOILTION AND DISMANTLING)
-
-
-
... More
Lump sum price worked out by the contractor for Demoilition and Dismanting as listed in Sch ‘A’ Part XI
1
74525
-
... More
SCHEDULE A PART- XII (FIRE FIGHTING)
-
-
-
... More
Lump sum price worked out by the contractor for Fire fighting as listed in Sch ‘A’ Part XII
1
731081
-
... More
SCHEDULE A PART- XIII (LIGHTIENING PROTECTION AND DG SET)
-
-
-
... More
Lump sum price worked out by the contractor for LIGHTENING PROTECTION as listed in Sch ‘A’ Part XII
1
136232
-
... More
SCH "A" PART XIV (RAIN WATER HARVESTING)
-
-
-
... More
Lump sum price worked out by the contractor for RAIN WATER HARVESTING as listed in Sch ‘A’ Part XIV
1
225047
-
... More
SCH "A" PART XV (LIFT AND DG SET)
-
-
-
... More
Lump sum price worked out by the contractor for LIFT & DG SET listed in Sch ‘A’ Part XV
1
2408744
-
... More
(MISCELLENEOUS B/R AND E/M ITEMS)
-
-
-
... More
M&L for excavation 250mm Dia bore holes complete in any type of soil including removal of surplus soil to the distance of 50 m complete all as specified and directed
23.2
-
-
... More
Supply and Lowering the 200mm dia MS perforated pipe into the Bore holes of 250mm Dia in recharge pit by and fix proper naylone mesh sourrounding pipe & Grating in top including required sand filling complete all as specified and as directed by Engr-in-charge.
23.2
-
-
... More
Material and labour for telephone point wiring with twin core telephone wire all as directed.
8
-
-
... More
Supply and fix Decorative wall mounted luminaire made out of Metal and Glass ,busshed nickle with unbreakable globe suitable for LED bulb and provn of LED bulb 12 watts B22 complete all as specified and directed.Philips cat part No.30950 or equivalent.
16
-
-
... More
S&F RJ 11 Tele Jack single with shutter 1 module complete with GI box and front cove all as specified
8
-
-
... More
S&F TV socket Jack single with shutter 1 module complete with GI box and front cove all as specified
32
-
-
... More
S&F wall mounted fan PVC body,300 mm sweep 3 speed control complete all as specified and directed.
4
-
-
... More
S&F Electric Chimeny wall mounted auto clean curved SS material, minimum air flow1200 m3/hr, maximum 60 db sound level,Built in oil collecter,230 volts ac 50Hz complete all as specified and directed
4
-
-
... More
S&F coaxial cable RG6 CU jelly filled complete all as specified and directed
300
-
-
... More
Supply ,install, testing & commissioning of indoor type, wall mounted (with anchor bolts & nuts) compartmentalized type Meter Cabinet for provision and fixing arrangements of 4 nos. energy meters of overall minimum dimension 900mm (W) x 750mm (H) x 200mm (D) made out of 2.0 mm thick CRCA Sheet with front door having cut out duly covered with transparent polycarbonate / glass panel for viewing KWh meter / Timer and other door shall be opaque. All doors should have gasket and locking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint (RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinet shall be fabricated as per the drawing and comprising of following accessories :-
a) Four pole MCCB, 100 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side.- 01 No.
b) Aluminium Bus Bar of 200 Amps duly mounted on FRP insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code - 4 Nos.
c) MCB TPN 32 Amps, 10 KA - 4 Nos ( To be connected with 4 Nos Meters)
d) MCB SP 06 Amps, 10 KA -2 No ( For common lighting & Bldg Security Lights)
e) Digital time switch 16 Amp-01 No
f) LED indicating Lamps,
g) 3 Way Bakelite strip type cable connector 30 Amps rating - 06 Nos
j) Internal wiring with 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :- i) MCCB to Bus Bar - 10.0 Sqmm copper ii) Bus Bar to Cable Connector via KWh meter and MCB - 6.0 Sqmm iii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm
1
-
-
... More
Supply ,install, testing & commissioning of indoor type, wall mounted (with anchor bolts & nuts) compartmentalized type Meter Cabinet for provision and fixing arrangements of 20 nos. energy meters of overall minimum dimension 2000 mm (W) x 1500mm (H) x 300mm (D) made out of 2.0 mm thick CRCA Sheet with front door having cut out duly covered with transparent polycarbonate / glass panel for viewing KWh meter / Timer and other door shall be opaque. All doors should have gasket and locking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint (RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinet shall be fabricated as per the drawing and comprising of following accessories :-
a) Four pole MCCB, 125 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side.- 01 No.(Incommer)
b) Aluminium Bus Bar of 200 Amps duly mounted on FRP insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code - 4 Nos.
c) MCB SPN 32 Amps, 10 KA - 20 Nos ( To be connected with 20 Nos Meters)
d) MCB SP 06 Amps, 10 KA -2 No ( For common lighting & Bldg Security Lights)
e) Digital time switch 16 Amp-01 No
f) LED indicating Lamps,
g) 3 Way Bakelite strip type cable connector 30 Amps rating - 06 Nos
j) Internal wiring with 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :- i) MCCB to Bus Bar - 10.0 Sqmm copper ii) Bus Bar to Cable Connector via KWh meter and MCB - 4.0 Sqmm iii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm
1
-
-
... More
M&L for earth work & cutting cast iron GI water mains pipes for tapping and reducing to required lenngth in position for insrtion of tees for branch connections of the internal dia pipe including Supply and fixing new tees upto 80x80x50mm of coller double side end socket and one side end flanged of using required lead joint etc all as specified and directed by eng-in-charge.
1
-
-
... More
M&L for earth work & cutting cast iron GI water mains pipes for tapping and reducing to required lenngth in position for insrtion of tees for branch connections of the internal dia pipe including Supply and fixing new tees upto 100x100x80mm of coller double side end socket and one side end flanged of using required lead joint etc all as specified and directed by eng-in-charge.
1
-
-
... More
Supply, installation, connecting and testing sluice valve cast iron body class-PN 1.6 with flanged ends drilled 100 mm (4") dia. ISI marked (IS:14846:2000) having brass spindle with iron wheel at top complete with nuts bolts washers rubber gasket etc all as specified and directed.
1
-
-
... More
Supply, installation, connecting and testing sluice valve cast iron body class-PN 1.6 with flanged ends drilled 80 mm (3") dia. ISI marked (IS:14846:2000) having brass spindle with iron wheel at top complete with nuts bolts washers rubber gasket etc all as specified and directed.
4
-
-
... More
Supply installation, commissioning & testing electric driven mono block centrifugal pumping set having discharge 200 LPM at 40 mtr head, with bronze impeller and SS shaft with electric motor 3 phase, 415 volt AC of suitable size capacity butnot less than 05 HP mounted on common base plate/ MS channel and PCC foundation of suitable size as per manufactureer recommendation and 400mm all around including jointing with delivery & suction with required JOinting ,material all as specified and directed.
2
-
-
... More
Supply and fixing swing type single disc cast iron foot valve (IS 4038) with screwed ends size 65mm bore for iron -pipes complete are specified and directed
2
-
-
... More
M&L for PVC insulated copper conductor flat submersible cable 1100 volts grade of 6 Sqmm 3 core size duly connected and lowered with submersible pump of set complete all as specified and as directed.
30
-
-
... More
Supply, installation, connecting and testing swing check type reflex valves (Non return) cast iron body class PN 1.6 design with flanged ends drilled suitable for the size 80mm. Bore of pipes ISI marked (IS:5312:2004 part-1) complete with nuts bolts washers rubber gasket etc all as specified and directed.
2
-
-
... More
Material & labour for construction of soakage well excavation of any type of soil foundation in PCC 1:3:6 ,wells ,of honey combed and solid in M-25 concrete including intercepting chamber screen chamber brick work in CM ,RCC cover slab in M-25 /SFRC cover interconnecting pipes of RCC/DWC complete filled with brick bats,complete of size 2.4 m dia X 4.5 m effective depth complete all as specified and as directed by Engineer-in-Charg.
3
-
-
... More
M & L for 50 users convetional type RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc. complete with effective depth 1.5 Mtr and overall depth of 3 Mtr.
1
-
-
... More
M & L for 150 users convetional type RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc. complete with effective depth 1.5 Mtr and overall depth of 3 Mtr.
1
-
-
... More
M&L for construction of block masonry valve pit chamber of size 600x600x600mm (internal dimensions) with 50 mm thick foundation using PCC 1:3:6 (type D-2), block masonry wall built in CM 1:4, 15mm thick internal plaster including top of floor in CM 1:4, finished even and smooth without using extra cement, and 20mm thick external plaster in CM (1:4) and 3.15mm thick MS sheet cover including 40x40x6mm MS angle frame fixed in PCC 1:2:4 type B-1 coping with 25x4mm flat iron hinges, hold fasts, handles, locking arrangements, applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer to all steel surface including excavation and earth work in any type of soil complete, as specified and as directed.
2
-
-
... More
M&L for construction of block masonry valve pit chamber of size 600x600x600mm (internal dimensions) with 100mm thick foundation using PCC 1:4:8 (type D-2), block masonry wall built in CM 1:6, 15mm thick internal plaster including top of floor in CM 1:6, finished even and smooth without using extra cement, and 20mm thick external plaster in CM (1:4) and 3.15mm thick MS sheet cover including 50x50x6mm MS angle frame fixed in PCC 1:2:4 type B-1 coping with 25x4mm flat iron hinges, hold fasts, handles, locking arrangements, applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer to all steel surface including excavation and earth work in any type of soil complete, as specified and as directed.
2
-
-
... More
Supply, installation, commissioning and testing of factory made (CPRI approved) LT Panel indoor type of suitable size, made ot of 2 mm thick CRCA sheet duly compartmentalized inside panel with 2 mm thick CRCA sheet for fixing of MCCB & instumentations compartments and frame etc. to accommodate the incoming mccb/ Motor Starter duly powder coated (The inner/outdoor shell. will have powder coated siemens grey) and having provision for front and rear side opening with rubber beading and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, The panel shall be placed on angle iron of size 50 x 50 x 6 mm frame supported on 04 legs 600 mm long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 angle frame shall be provided with mild steel sheet 300 mm width and 1.6 mm thick on three sides duly fixed with nu ts and bolts complete all as specified and directed.(Motor starter paid seperatly).Panel shall comprise of the following:-
1
-
-
... More
(a) Incoming MCCB 4 pole 3 phase, 63 Amps,415 Volts AC rupturing capacity 25 KA -01 No. b) Copper colour code 100 Amps - 4 Nos. (c) Out going MCB TP 40 Amps repturing capacity 10 KA - 02 No' (d) MCB DP 32 amp -02 NOs.
(e) Digital amp meter size 96x96mm CT operated, 3 phase, aux supply 230v AC, with built in selector switch - 2 Nos. (f) Digital volt meter to read phase and line voltage for 1100 volt, aux supply 230 volt AC with built in slector switch - 1 Nos. (g) DOL starter 3 phase 415 volt air break type capacity suitable to operate 10 HP motor. (h) Indicator lamp neon type (RYB) with holder,one set for each incoming and out going - 01 Sets.
(j) Complete internal wiring with suitable sizes copper conductor PVC insulated cable. (k) Danger Notice plate 440V with conventional skull and bones in red signal colour.
-
-
-
... More
Earthing complete all shown as electrical plate No -03 of MES Sch part -I as specified with testing and as directed including the following.
(i) Galvanised steel earth plate of size 60x60cmx6mm thick burried directly in ground vertically to a depth not laess than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.50 metres below ground level.
(ii) Earth plate surrounded by and packed with charcoal and common salt in alternative layers ( n.exc 15 cms each layer).
(iii) 32x6mm G I strip from earth plate to test point including necessary GI bolts, nuts, check nut, washers & thimbles etc.
(iv) 20mm bore, medium grade, GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontaly to the earth pit. (v) 40 mm dia bore G. I. light grade pipe for protection of GI strip. (vi) Cement concrete chamber of PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate. The chamber shall be constructed one metre away from edge of earth pit. (vii) 50mm thick precast cover of cement concrete(1:2:4) type B-1 using 20mm graded crushed stone aggregate and MS angle iron 50x50x6mm frame including two coats of black paint synthetic enamel painting over a coat of red oxide to exposed steel surfaces with suitable handle to lift the cover. (viii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance of 50m as directed.
6
-
-
... More
M&L for drilling suitable dia horizontal bore holes for insertion/ laying of 100/50/40 mm bore GI tubing of any description below/under existing road surfaces / apron /floors etc with using mechanical and / or manual devices as required at site including making good the disturbed surfaces to match with the existing streta after laying pipes complete all as specified and directed.
40
-
-
... More
S&F Weather Proof thermo plastic (Polysterene) Cable Junction box, having protection class IP-66 and of overall size 155mm x 210mm x 92mm (Approx) having metric knockouts on the wall, duly fixed with the pole with aluminium strip (25x3mm) clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glands of cable sealing range 10mm to 17mm (Complete with check nut) and including 1 No 30 Amps 4 Way cable connector and 1 No. 6 Amps SP MCB.
14
-
-
... More
supplying and fixing new GI Pipe brackets made out of 32 mm dia GI pipe, medium grade, 1.5 mtr length, bent to shape , fixed with two Nos 25x3 mm size flat mild steel clamps made to shape and size and suitable nuts bolts and washers etc compete all as specified and directed. Make of pipe Jindal
14
-
-
... More
Supply and fix new generation energy saving & environmental friendly long life LED streetlight made up to pressuer dia cast housing with loughned glass and indvidual high power LED's with secondery optics, IP66 protection and impact resistance of IK07 and electronic driver of 45W LED 5700K and making necessary connections with 2.5 sqm twin core cable 1100 volts upto MS box on pole complete all as specified and directed.
14
-
-
... More
S&F,commissioning and testing factory made compact air insulated vertical copper bus bar truncking system 3 phase 1 neutral with isolated earth (rising bus bar).Copper bus bar strip should be rectangular in section ,low impedence,high conductivity of 250 amp ,450 V,35 KA breaking capacity for phase/neutral and half core earth ,mounted on insulators including seperaters,rate insulation level 1100 volt grade,insulation class F complete with CRCA sheet metal enclosure totally enclosed type ,duly powder coated paint,IP 54 protection including fixing in proper allignment and security by means of brackets,clamp,nut,bolt and screw of adequate size/capacity and number for load cap as recommeded by manufacturer complet with flexible joints,end feed units having facility for plug in /type of box of 32 to 400 amp TPN all as specified and directed. Note- Tap of box /plug in box with protection device for domestic connection shall be paid seperatelly
25
-
-
... More
Supply& fix ,testing & commissioning of plug in box/Tap off box CRCA sheet duly powder coatedpaint with MCCB 63 Amp 4 pole 16 KA rotary handle type & door interlockingwith bus trunckingsystem including provn for cable entry& glandplates for both side & bottom of plug in box &integral earth system.
6
-
-
... More
M&L for sign board made of 2mm thick aluminium sheet and the board shall be covered using 3M India type IV retro reflective sheet of blue clour and the letters on it shall be of white colour on both side.The board shall be supporrted by 32mm bore stainless steel 304 SS Grade round pipe & 25X12mm tublar pipe and fix over stainless steel post pipe of dia 63.5 mm 304 SS Grade including necessary work of cutting, welding,nuts,bolts,anchor plates etc. with fixing by PCC 1:2:4 Type B1(using 20 mm graded stone aggregate) cast in situ of each leg post in various loction for fixing of sign boards including necessary earth work complete all as specified and as directed by Engr-in-charge.
3
-
-
... More
S&F LT panel complete indoor type cubical panel board suitable for 3 phase, 4 wired, 433V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 433 volts factory fabricated in an approved factory with CRCA sheet not less than 2 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general constructions conforming to IS : 8623/93. The LT Panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears. The panel should have suitable size of Aluminium bus -bar three phase 4 wired system having current carrying capacity not less than 1.2 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and outgoing controls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engr-in-Charge.
1
-
-
... More
OUTER SHELL : the outer shell shall be made of min 3.15mm thick CRCA sheet supported on MS angle section 75mmx75mmx5mm froame with openable front & back with concealed hinges, single door system, lockable/openable by keys from both sides, having flush pattern fancy locks, louvers & air vent with gasket fornatural flow of air. The bottom of the outer shell contains a detachable plate with hinge provision for entry of armoured cable with adequate size glands. Provision of earthing studs at bottom and threaded lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone and skull shalll be provided
-
-
-
... More
INNER SHELL : Inner shell mad eof 2.00mm thick CRCA sheet compartmentalized to accommodate each control gear, front openable, single door system lockable/openable with "U" type gasket to make the inner shell completely vermin proof ghaving chromium plated locks (2 Nos in each compartment ) All control wiring shallbe with not less than 1.5 Sqmm multistand copper conductor and shall be properly bunched . tied ferrruled for proper indetification and crimped with adequate size of lugs. the cubical shall have a bottom channel of size 75x75x5mm duly pained with zinc based primer. A detachable predrilled gland plate of thickness 3.15mm shall be used at the bottom. An inspection lamp with 11 Watt CFL shall be fitted on top side of inner shell.
-
-
-
... More
INCOMING (i) MCCB 320 A 36 KA 4 pole -1 No. (ii) Digital Multi functional meter VAFPP (voltage, current,frequency, power factor-1 No. (iii) Phase indicator lamp (LED type) 1 set (set of three). OUT GOING
(I) MCCB 200 A 36 KA 4 Pole-01 Nos
(i) MCCB 125 A,16 KA, 4 pole -03 Nos.
-
-
-
... More
S&F LT panel complete indoor type cubical panel board suitable for 3 phase, 4 wired, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 2 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general constructions conforming to IS : 8623/93. The LT Panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears. The panel should have suitable size of Aluminium bus -bar three phase 4 wired system having current carrying capacity not less than 1.2 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and outgoing controls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engr-in-Charge.
1
-
-
... More
INCOMING (i) MCCB 100 A 25 KA 4 pole -1 No. (ii) Digital Multi functional meter VAFPP (voltage, current,frequency, power factor-1 No. (iii) Phase indicator lamp (LED type) 1 set (set of three). OUT GOING
(i) MCCB 32A, 10 KA, 4 pole -04Nos.
(iii) MCB 2 P 16 amp-02 Nos
-
-
-
... More
Supply ,install,testing & commissioning of indoor type ,semi concealed compartmentalized type meter of cabniet of suitable size made out of 2.0mm with transparent polycarbonate/glass panel for vewing KWH meter /Timer and other door shall be opaque. All door should have gasket and locking arrangements to meet ingress protection level IP-43 , The cabinet shall be painted both externally and internally with powder coated paint after necessary surface treatment . The cabinet shall be fabricated as per drawing and comprising the following accessories :- .
1
-
-
... More
(a) Four pole MCB ,63 amp with braking capacity 16 A (b) Copper bus bar of size 25 mmx3mmx duly mounted on FRP insulator and necessary drilling for 1 incoming & minimum 6 outgoing connecton and duly covered with heat shrinkable PVC sleeves of standard colour code -4 nos
(c) MCB TPN 20 amp 10 KA -4 Nos|(To be connected with 4 nos meter)
(d) MCB SP 6 amp 10 KA-02 nos(For common light and bldg seciruity light)
(E) Analouge time switch 16 amp-01 Nos
(f) indicating lamp-22 mm with 3 amp SP MCB-03 Nos
(g) 3 way bakelite strip type cable connector 30 amp rating-04 Nos
-
-
-
... More
(h) Dial type DIL rail mounting analog time switch 16 amp /230 volt 50 hz battery backup,24 hrs proggramable typw with 1 NO &1 NC contact -01 No (for security light)
(j) Internal wiring with 1100 v grade FRLS PVC insulated multistranded core flexible copper wire of size duly crimpped with copper lux odf suitable size& type al as mentioned below-
(i) MCB bus bar -10.0 sqmm copper
(ii) bus bar to cable connector via KWH meter and MCB -4 sqmm
(iii) Bus bar to LED lamp via MCB -1.5 sqmm
(k) Space for accomodate 3 phase 4 wire electric smart meter -4 no
-
-
-
... More
M&L for distribution board vertical Sheet metal enclosures for MCCB DB Triple pole and neutral, double door, 4 way, 415 volts, powder coated with IP 43 protection, including provision and housing MCB,s and fixed flush on wall and grouting complete all as specified and as directed by Engr in Charge.
Notes:- (a) The cost of fixing the DB flush to brick / stone wall surface, including cutting holes / chases, packing around the DB, making good and finishing to match surrounding surfaces shall be deemed to be included in the quoted rates. (b) MCCBs shall be measured and paid separately.
2
-
-
... More
Supply and fix, MCCB, 4 pole 415 volt 63 Amps 25KA with adjustable thermal and fix magnetic setting complete all as specified
2
-
-
... More
Supply, commissioning erecting and testing complete of OEM manufactured, static silent (sound proof enclosure) Diesel Engne driven Generating set of capacity 50 KVA/40KW, water cooled, 415 volts (AC three phae, 4 wire sysyem of supply) 50 Hz at power factor 0.8 minimum. The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with complete with conrtol panel standarized by manufactured, of adequate capacity for 8hrs running fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangements, exhaust pipe complete and suitable at BKT Lucknow (capcity of engine, alternators shall worked out taking all derating factors into consideration) including foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5m height) as per manufacterer recommendation, anti-vibration pads complete all as specified and directed, confiriming to emission norms (No + HC 4.0, Gm/Kwhr CO 3.5gm/Kwhr, PM0.2gm/kwhr, smoke limit 2.7m-1) inclusing all feature tol comply with latest CPCB guidelines and comprising of followings :-
1
-
-
... More
(A) DIESEL ENGINE :
Diesel Engine 1500 RPM, direct injection, multi cylinders, four stroke, conforming to IS:100001/ISO3046/BS:649/BS:5514 amended upto date, for continious running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive ALternator capable of delivery 50KVA at outdoor atmospheric conditions at BKT Lucknow ( taking all derating factor into consideration) fitting with the following accessories subject to the design of manufacturer: -
(i) Dynamically balanced fly wheel.
(ii) Air Cleaner oil bath type
(iii) ELectronic Governer class 1A with backup Mechanical class 1A Flywheel with starter ring
(iv) Dry exhaust amnifold with suitable exhaust residential grade silencer to reduce the noise level
(v) Radiator cooling
(vi) Radiator fan with guard
(vii) Vaccum indicator
(viii) Fuel filter and fuel houses
-
-
-
... More
(B) ENGINE INSTRUMENT PANEL digital type having facility for automatic/manual starting, reset switching with an indicating the following including internal control wiring controlled with MCB & connected to safety features of Engine & Alternator :-
-
-
-
... More
(i) Starting switch on/off
-
-
-
... More
(ii) Water temp guage
-
-
-
... More
(iii) Hour meter cum RPM indicator
-
-
-
... More
(iv) Lub oil pressure gauge
-
-
-
... More
(v) Lub oil temperature guage
-
-
-
... More
(vi) Battery charging meter
-
-
-
... More
(vii) Safety alarm against high water temp and lub oil pressure
(viii) Any other tem not included/speciified but is a standard design pf the manufacturer.
-
-
-
... More
(C) ALTERNATOR : Shall be self excited, self regulated, bush less for 50 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with + 1% with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 4722 complete- 1 No. Note : Aletrnator should be able to deliver output reading at actual site condition.
-
-
-
... More
(D) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of .suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No NOTE:- Cost of suitable size of PCC foundation including 400mm extra pcc platform around the DG set from outside of the canopy is deemed to be included in the unit rate quoted by the contractor.
-
-
-
... More
(E) Bottom mounted (or as per manufacture design) steel fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 12 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete.
Bypass arrangement by providing seperate panel made out of 3mm thick CRCA sheet, outdoor type with connection copper bus bar of suitable size from change over and set of 3 Nos indication lamp for R,Y and B and 2 Nos 4 pole on load change over switch front handle operated of capacity 80 Amp is to be installed near AMF panel complete all as specified and directed.
(i) Hour run meter
(ii) Any other item not included/specified but is a standard design to the manufacturer
-
-
-
... More
(F) AMF CONTROL PANEL : Supply, fabrication, fixing commissioning and testing, factory made, floor mounted, cubiocal automatic mains failure with degree of protection IP 42 conforming to IS 2147, suitable for 50 KVA DG set, fabricated using 14 guage thick CRCA sheet, powder coated painting comprising of suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming & outgoing leads/bus bar as approved with and including the following accessories as under:-
-
-
-
... More
(i) Master switch for auto/manual/reset/off- 01 No
-
-
-
... More
(ii) Ammeter digital type 96x96 mm to read 0 - 500 amps with CT's 1 set of 3 Nos, aux supply 230 volts, AC, accuracy class 1.0
-
-
-
... More
(iii) Voltmeter digital type,96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0
-
-
-
... More
(iv) Digital frequency meter -01 No. aux supply 230 volts, AC
-
-
-
... More
(v) Push button start, stop,reset - 01 No
-
-
-
... More
(vi) Set of lamp for indicating load asset , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure
-
-
-
... More
(vii) Battery charger, connected to load.
-
-
-
... More
(viii) Transformer of adequate rating.
-
-
-
... More
(ix) Rectifiers
-
-
-
... More
(x) DC Ampere and volt meter
-
-
-
... More
(d) Charger rate selector for trickle or high charging
-
-
-
... More
(e) Indicating lamp for battery charging
-
-
-
... More
(viii) Fault accept/reset push button
-
-
-
... More
(ix) Set of relays and contactor suitable for 500KVA DG set for automaitc start and auotmatically shutdown of suitable rating and capacity adjustable to 70% to 100% and 02 Nos MCCB 4 Pole 80 Amps,, 25 KA fixed on main supply and DG set supply.
-
-
-
... More
(x) Make /Design of AMF control panel shall be as per Oem recommendation.
-
-
-
... More
M&L for provision of mounting stand for air termination rod(as per sl item no. 2 above) made out of GI tubing 15mm bore medium grade ISI marked 1.5mtr long welded with GI strip 20x4mm making four legs for fixing vertically on and including pocerlein/epoxy insulator and fixed on PCC block size 300x3000x200th mm complete all as specified and as directed. (Note : PCC shall be measured and paid seperatly under slm item no.4 of schedule.)
17
-
-
... More
M&L for PVC insulated copper conductor flat submersible cable 1100 volts grade of 10 Sqmm 3 core size drawn through PVC conduit fixed on wall with all accessories to connect tarrace pump complete all as specified and as directed.
100
-
-
... More
Supply and fix cast iron air realease valve with single air outlet confirming to IS 4845 of size 20 mm dia bors and fixing up in MS pipe 100 mm bore complete set , all as specified and directed.
1
-
-
... More
S & F branch piece pipe with nozzle of 20 mm dia for hose real conforming to IS 8090 complete all as specified and directed.
6
-
-
... More
Supply, laying & testing PVC insulated, PVC Sheathed cable galvanized steel strip or wire armoured, electric control cable (Heavy duty) with stranded copper conductor of size 4 Core, 4 Sq mm 1100 Volts grade for connection to repeater panel from main panel all as specified and directed.
800
-
-
... More
Supply a glow in dark FIRE EXIT sign board with man running arrow symbol and stair of dimension 12" X 6" X 8 mm decorative transparent acralic, including fixing arrangment all as specified and directed complete, all as specified and directed.
1
-
-
... More
Supply, Installation, Testing and commissioning of 120 Watt Amplifire complete, all as specified and directed.
10
-
-
... More
Supply & fixing of public Address wire 2 Core in PVC condute pipe for talk back facility complete, all as specified and directed.
100
-
-
... More
Supply, Installation, Testing and commissioning of 4 zone selector with rack for mounting Amplifer complete, all as specified and directed.
1
-
-
... More
Supply, Installation, Testing and commissioning of Single master and 8 way slave for talk back system complete as required ( Control Room)
1
-
-
... More
Suppy, installation, commisionig and testing cubical pannel board 3 phase 4 wire 415 volt AC 50 Hz, factory made indoor type fabricated with 2mm thick CRCA sheet dust and vermin proof duly powder coating painted over a coat of red oxide primer having bus bar chamber with 4 Nos 100 Amps copper bus bar on appoxi insulator 1100 volt grade, mounted on angle iron frame made out of 40x40x5mm angle iron 300mm high above floor level and grouting 150mm in PCC on all four corners with and including internal connections using copper cable/wire/bus bar and following items.
1
-
-
... More
INCOMING :- (a) MCCB 63 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity , 16 KA with adjustable thermal magnetic setting– 01 No. (b) Indicating lamps LED type for three phases -R Y B of 3 Nos,
(c) Digital Voltmeter 96x96mm to read phase and line voltage 500 volts with built in selector switch, aux supply 230 volt AC-01 No.
-
-
-
... More
OUTGOING:- (a) Digital amp meter size 96x96mm CT operated, 3 phase, aux supply 230v AC, with built in selector switch - 2 Nos. (b) MCB TP 40 Amps 10 KA - 02 No. (c) Star delta starter 3 phase 415 volt air break type capacity suitable to operate 10 HP motor. (d) MCB SPN 32 Amps 10 KA 2 Nos.
-
-
-
... More
Supply and fixing Fire Extinguisher, water stored pressure type, 9 Ltrs cap, confirming to IS 15683
5
-
-
... More
Supply and fixing Fire Extingusher CO2, 4.5 Kg cap, confirming to IS 15683 (Light Wt Squeeze grip type)
6
-
-
... More
Supply and fixing Fire Extinguisher, Dry chemical Powder, (ABC) Type, 6 Kg cap, confirming to IS 15683
7
-
-
... More
Supply and fixing Fire Extinguisher, Mechanical foam type, 9 liters cap, confirming to IS 15683
2
-
-
... More
Supply and fixing Fire Bucket dry sand, 10 Ltrs cap, confirming to IS 2546
2
-
-
... More
Sch 'A' Part 'XVII' Manning & Operation of lift during the defect liability period Manning & Operation for annual maintenance of lift for 08 & 13 persons by performing all fortnightly, bi monthly, half yearly and yearly checks and tests including all repair and replacement of unserviceable spare parts for making serviceable after the completion of defect liability period (DLP) through OEM, all as specifed and directed.
-
-
-
... More
(a) For first year during DLP
365
-
-
... More
(b) For second year during DLP
365
-
-
... More
Note :- (a) The contractor shall enter MOU with the OEMs for the provn of the lift and further maintenance. The MOU for the port warranty / post defect liability period between the contractor and OEM shall be submitted. (b) The rate quoted is inclusive of all consumable and spare parts as the same lies within defect libality period.
-
-
-
... More
Sch 'A' Part 'XVIII' Annual maintenance of lift after defect liability period (For the period of three years)
Annual maintenance of lift for 08 persons & 13 persons (02 Nos of Lift) by performing all fortnightly, bi monthly, half yearly and yearly checks and tests including all repair and replacement of unserviceable spare parts for making serviceable after the completion of defect liability period (DLP) through OEM, all as specifed and directed.
-
-
-
... More
(a) For first year after DLP
1
-
-
... More
(b) For second year after DLP
1
-
-
... More
(c) For third year after DLP
1
-
-
... More
Note :- (a) the contractor shall enter MOU with the OEMs for the provn of the lift and further maintenance. The MOU for the port warranty / post defect liability period between the contractor and OEM shall be submitted. (b) The rate quoted is inclusive of all consumable and spare parts and the rate quoted against the item is deemed to be inclusive of maintenace, operation & cost of spare parts required for making the Lift in servicable condition..
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%