Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date11 Jan 2025
Closing Date31 Jan 2025
Tender Amount₹ 10,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR REPLACEMENT TO OLD UNSV ACBS, CHANGE OVER SWITCHES, HIGH MAST LIGHTS, PANEL EARTHING, REPLACEMENT TO UNSV LT CABLE ALONGWITH CERTAIN MISC E/M WORKS UNDER AGE (I) AYODHYA CANTT
REPAIR REPLACEMENT TO OLD UNSV ACBS, CHANGE OVER SWITCHES, HIGH MAST LIGHTS, PANEL EARTHING, REPLACEMENT TO UNSV LT CABLE ALONGWITH CERTAIN MISC E/M WORKS UNDER AGE (I) AYODHYA CANTT
REPAIR REPLACEMENT TO OLD UNSV ACBS, CHANGE OVER SWITCHES, HIGH MAST LIGHTS, PANEL EARTHING, REPLACEMENT TO UNSV LT CABLE ALONGWITH CERTAIN MISC E/M WORKS UNDER AGE (I) AYODHYA CANTT
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F in replacement, MCCB, 4 pole, 160 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA, lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge.

4

-

-

... More
S&F in replacement, MCCB, 4 pole, 200 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA, lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge.

3

-

-

... More
S&F in replacement, MCCB, 4 pole, 250 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge.

2

-

-

... More
S&F in replacement, MCCB, 4 pole, 400 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
S&F in replacement, On load Change over switch 125 Amp, 415V 50Hz with steel sheet enclosure and operating handle confirming to IEC : 60947-3 including connection and testing complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
S&F in replacement, On load Change over switch 63 Amp, 415V 50Hz with Sheet steel enclosure and operating handle confirming to IEC : 60947-3 including connection and testing complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Servicing / Repair to ACB of various Capacities of outdoor / indoor type, tripping circuit and resetting trip values and the nuemerical relays and checking tripping machnism fully by engaging well experienced technicians as per manufacturer's recommendation and directed by the Engineer-in-Charge.

4

-

-

... More
Taking LT shut down, dismantling and removing motor of the High Mast light pole from existing position, shifting to authorized workshop for necessary repair work, removing the burnt winding, cleaning rotor / stator, re-winding the motor with new super enameled copper wire of size of the original winding including insulated packing materials, varnishing, drying etc and installing back to the original position, testing and commissioning complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
S&F Nature switch sensor illuminate level for switching on 30 lux and for switching off 10 lux alongwith part night operation facility of 4-12 hours complete all as specified and directed by Engr-in-Charge. Make Swadeep / CG/L&T/Havells

3

-

-

... More
S&F Automatic street light switch using Nature Switch for automatic switching of street lights based on lux level of natural light. The sensor (Nature Switch) alongwith and including supply and fixing of suitable power contactor of 1 No. 40 Amps (Two pole ) two Nos MCB 63 Amps (single pole) and support terminals enclosed in pole /wall mountable enclosure of suitable size made out of rust proof electric shock proof termite proof and FR grade special moulding compound sintex make SMC junction box of suitable size confirming to IP54 circuit wiring suitable enough to take load of 8 KW single phase load, all as per Kadatiya Energy System Ltd Hydrabad Model SWADEEP or techno commercially equivalent models in Havells/ L&T complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
S&F in repair digital timer switch complete all as specified and directed by Engr-in-Charge. Make - L&T /Havells/shcnider.

5

-

-

... More
S&F in replacement, Garden/ Gate light decorative made of high grade unbreakable polycarbonate material powder coated including one LED lamp 14W/20W B22 base and fixed with suitable dia & height light grade GI Pipe complete all as specified and directed by Engr-in-Charge. Make- Havells Cat part No :- CORALMINIPT15WLED757PSYMTOPC or equivalent to Bajaj/ Philips/ CG.

6

-

-

... More
S&F in repalcement, LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-In-Charge.

10

-

-

... More
Dismantling existing earthing of any description and M&L for new Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.0 mm thick, burried directly in ground vertically to a depth not less than 2.25 m below the ground level with top edge of earth plate at a depth not less than 1.50 m below ground level. Earthing plate surrounded by 15cm thick packed alternative layers of charcoal dust and common salt, connected with GI strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles at one end and the other end connected to main switch board and protected by 40mm dia bore medium grade GI pipe. Provision of 20mm dia bore light grade GI pipe for watering including GI funnel and wire mesh. The pipe shall be provided vertically upto top level of earthing pit and then taken horizontally to the equipment. Provisionn of cement concrete chamber of iinternal size 300x300x300mm with PCC (1:3:6 ) type C-2 (using 40 mm graded stone aggregate), constructed at 1.00 m metre away from edge of earthing pit with 50 mm thick precast RCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) reinforced with 8mm dia TMT bars @ 150mm C/C including all necessary earthwork in soft / loose soil complete all as specified and shown in Electrical Plate No. 3 of SSR Part-1 (2009) and directed by Engr-in-Charge. Note: (a) The unit rate includes earthing strip and protection pipe upto maximum 7.5 metre from earth plate, earth point / test point. (b) On testing after completion, if the desired earth resistance is not obtained, the earthing will be redone at no extra cost.

4

-

-

... More
S&F Earth continuity conductor or main earthing lead fixed to walls or to poles or any other indicated situation for loop earthing with 25x4mm galvanised iron strip complete all as specified and as directed by Engr-in-Charge.

30

-

-

... More
Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.

81

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soilcomplete all as specified and directed by Engr-in-Charge.

43.43

-

-

... More
Removing excavated materials (soil) n. exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.

37.58

-

-

... More
M&L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness only shall be measured for payment purpose.

24.3

-

-

... More
Supply & Laying old size sub class 'B' brick, locally available best quality laid flat (length of bricks laid across the length of cable) in trenches for protection of underground cable complete all as specified and directed by Engr-in-Charge.

2.61

-

-

... More
Supplying, laying, commissioning & testing 10 Sqmm 2 core LT underground cable, 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp etc complete all as specified and directed by Engr-in-Charge.

150

-

-

... More
All as per Srl item No. 24.00 above but 16 Sqmm 4 Core cable

150

-

-

... More
All as per Srl item No. 24.00 but 25 Sqmm 3. 5 Core cable

150

-

-

... More
All as per Srl item No. 24.00 above but 50 Sqmm 3. 5 Core cable

150

-

-

... More
Repair / maint and overhauling of existing LT Panel 3 phase AC 415V, 50 Hz A of any make including taking out old /unsv MCCBs & MCBs / incoming and outgoing laminated copper busbar, DMC / epoxy insulators of any size, Volt meter, Amp meter, phase indicator LED lamp, Change over switch of any capacity, burnt out copper winding, current coil, potential coil and keeping aside in safe custody for re-use, opening the LT Panel, removing gasket, dismantling and taking out old parts carefully, disconnecting all conections, & re-assembling all serviceable parts to original position including replacement of unsv nuts, bolts, thimbles, gasket etc as per site requirement, removing sludge, dirt, dust etc, denting, welding & replacement of unsv hinges if required, removing old paint and applying two coats of synthetic enamel paint with spray machine over a coat of red oxide primimg paint, re-connecting & testing complete all as specified and directed by Engineer-in-Charge. Note : (a) All spare parts and control wiring shall be measured and paid for seperately under respective item of Sch 'A' at S&F rates. (b) Denting, welding, replacement of unsv hinges, locking arrangement, handle, unsv gasket, cable gland, nut, bolt, washer, minor repair of PCC foundation if required and removing of old paint with re-assembling, testing, commissioning etc shall be deemed included in the quoted rate. (c) Civil work for grouting of panel cement concrete shall be deemed to be included in the quoted rate.

5

-

-

... More
Dismantling existing panel of any description and Supply & installation and testing & Commissining CPRI approved outdoor cubical type IP 54,LT feeder piller box suiable for 415 V, 3 phase 50 Hz , AC supply system, dust,weather & vermin proof, made of 3.15 mm thick CRCA sheet, powder coated with 7 tank process,TPN copper busbars of rating 250 Amp Cap.Bottom base channel of MS section not less then 45mmx45mmx5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x5mm at the rear with 2 no earth stud,double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers. cable entry with glands, foundation/grouting on & including PCC as per site requirement with the following :- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulator 250 Amp,4 pole, not less then 45 CM long mounted on insulators for incoming supply - 1 Set (Set of 4 strips) (b) Phase indicator lamp RYB LED type - 1 Set (Set of three). (c) Digital Voltmeter & Ammeter - 02 Nos (d) CT of suitable ratio (Set of three) Incoming: (a) MCCB 160 Amp, 415V, 50 Hz, FP, 25 kA, Ics= 100% Icu fixed type, complete all as specified and directed by Engr-in-Charge. Note :- (i) Panel shall be installed at least 60 cm above ground (ii) All civil/electrical work & material is deemed to be included in the quoted rates (iii) Drawing of Lt feeder panel shall be got approved from GE. (iv) Panel shall confirm to IEC - 61439 updated to date.

3

-

-

... More
Labour for cutting/ trimming of tree branches up to 80mm thickness along the alignment of LT / HT over head electric line which are going / touching or falling or ACSR conductor/ poles or near by sub stations etc at any height from GL and making at least clearance 1.5m from conductor and removing to a distance up to 100 mtr where directed by Engineer-In-Charge. Note:- (i) Trimming of the branches on one side of the conductor. (ii) Actual length of cutting shall be measured. (iii) The distance as mentioned above shall be maintained during contract current period & same location subject to at least 6 months period between two trimming / laping. (iv) Measurement shall be taken including all conductor as one only. (v) All safety measures to be adhered to by the contractor

1000

-

-

... More
S&F heat shrinkable End termination kits and accessories of following capacities and type:-

-

-

-

... More
Outdoor/indoor 16 to 25 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable

5

-

-

... More
Outdoor/indoor 35 to 50 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable

10

-

-

... More
Outdoor/indoor 70 to 120 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable

8

-

-

... More
Outdoor/indoor 150 to 185 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable

5

-

-

... More
S&F heat shrinkable straight through joint kit and accessories of following capacities and type:-

-

-

-

... More
Straight through joint kit indoor/outdoor al conductor cable of size 16 to 25 Sqmm and 3.5/4 core

3

-

-

... More
Straight through joint kit indoor/outdoor al conductor cable of size 35 to 50 Sqmm and 3.5/4 core

3

-

-

... More
Straight through joint kit indoor/outdoor al conductor cable of size 70 to 120 Sqmm and 3.5/4 core

3

-

-

... More
Straight through joint kit indoor/outdoor al conductor cable of size 150 to185 Sqmm and 3.5/4 core

2

-

-

... More
S&F Powder coated Pin Type Panel lock in round shape (Male & Female socket) diameter appx 22 mm for female socket complete all as specified and as directed by Engr-in-charge

100

-

-

... More
Supply only non -metallic PVC clamps required for cables laying above the wall/drainage/PCC area of size 20 sqmm etc complete all as specified and directed by Engr-in-Charge.

300

-

-

... More
Supply only non -metallic PVC clamps required for cables laying above the wall/drainage/pcc area of size 40 sqmm etc complete all as specified and directed by Engr-in-Charge.

300

-

-

... More
Supply and fixing of suitable size of nut, bolts/ washers of brass/GI for replacing defective nut, bolts etc complete all as specified and directed by Engr-in-Charge. Make : TVS or equivalent as approved by AGE (I).

10

-

-

... More
S&F in repair, aluminium sector lugs short barrel of following sizes:

-

-

-

... More
25 Sqmm

150

-

-

... More
35 Sqmm

150

-

-

... More
50 Sqmm

100

-

-

... More
70 Sqmm

100

-

-

... More
95 Sqmm

75

-

-

... More
120 Sqmm

50

-

-

... More
150 Sqmm

50

-

-

... More
Hiring of cable fault detector to detect exact position of fault for XLPE /PVC LT/HT cable, 1100 / 11000 Volts grade heavy duty aluminium conductor of any size including to and fro transporting charges etc complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Horizontal boring in soft/loose soil/under roads of any width by manual arrangements for inserting GI pipe up to 100mm bore for passing cables complete all as specified and directed by Engr-in-Charge. Note : GI pipe shall be measured and paid for separately.

24

-

-

... More
Supply and lay DWC HDPE pipe 50 mm bore medium class, ISI Marked double wall corrugated for open / underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates. as in cable protection pipe of outer dia 40mm including all fittings complete all as specified and directed.

100

-

-

... More
Supply and lay DWC HDPE pipe 80 mm bore medium class, ISI Marked double wall corrugated for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates. as in cable protection pipe of outer dia 40mm including all fittings complete all as specified and directed.

60

-

-

... More
Supply & laying steel tubing, 50mm dia bore, galvanized, light grade for passing LT/HT cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as directed and specified.

12

-

-

... More
All as per Srl item No. 39.00 above but 80mm dia bore GI tubing

12

-

-

... More
M&L for preparing old painted surface of steel tubular swaged poles (9 to 11 meter long) with good neck brackets including junction box, GI pipe and painting with one coat of aluminium paint including cleaning the acrylic cover and painting with black paint upto 1.5 mtr height from top of PCC coping and marking pole numbers with one coat of synthetic enamel paint in approved size and shade complete all as specified and directed by Engr-in-Charge.

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.