Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date27 Sep 2024
Closing Date17 Oct 2024
Tender Amount₹ 44,00,000
Costs
EMD
₹ 88,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_676932_1Bid Award Id
ViewTender No
8000-2180/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Taking down cement plaster on brick or stone or concrete surfaces of wall etc , icluding raking out joints , hacking for key, scrubbing down with water etc. complete all as specified and directed.
890
-
-
M&L for rendering 15mm thick on fair face of brick works or concrete surfaces of walls with CM (1:6) and finished even and smooth without using extra cement complete all as specified and directed.
325
-
-
M&L for rendering 15mm thick on other than fair face of brick works or concrete surfaces of walls with CM (1:4) finished surface should be even and smooth including WPC @2% by weight of cement complete all as specified and directed.
535
-
-
M&L for rendering 10mm thick on concrete surfaces of ceiling with CM (1:4) and finished even and smooth without using extra cement complete all as specified and directed.
180
-
-
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square meter, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings including taking down of old plaster and putting aluminium channel in groove of required size complete all as specified and directed.
Note : Making grooves (of uniform size 15 mm x 15 mm) shall be included in quoted rates.
184
-
-
M&L for preparation of newly plastered surface of walls and applying two or more coats of 100% premium acrylic emulsion paint exterior grade paint over a coat of exterior primer including preperation and application of 1 mm thick wall care putty complete all as specified and directed.
535
-
-
M&L for complete removal of old decorated surface of walls and applying two or more coats of 100% premium acrylic emulsion paint exterior grade paint over a coat of exterior primer including preperation and application of 1 mm thick wall care putty complete all as specified and directed.
515
-
-
M&L for preparing new plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
180
-
-
M&L for preparation of old plastered decorated surfaces of ceiling and applying two coat of white wash complete all as specified and directed.
370
-
-
M & L for two or more coats of distemper oil emulsion on newely plastered wall surfaces over a coat of priming with alkaliresistant primer including preparation and application of 1 mm thick wall care putty complete all as specified and directed.
325
-
-
M & L for complete removal of existing treatment of old decorated surface of walls and applying two or more coats of oil bound distemper including preperation and application of 1 mm thick wall care putty complete all as specified and directed. complete all as specifed and directed.
675
-
-
Demolition of cement concrete ( reinforced) of any description in any position not otherwise specially provide for complete all as specified and directed.
4.5
-
-
M&L RCC (1:1.5:3) ( Type A-1 ) using 20 mm graded stone aggregate as in slabs supported on walls , beams, columns and similar work etc . complete all as specified and as directed.
3.5
-
-
Use and waste formwork to soffits of suspended slab, slab supported on walls, columns, beams and similar work not exceeding 200 mm thick (Horizontal or sloping) , rough finished surface of concrete all as specified and directed
62
-
-
M&L for TMT bar 10 mm dia and over cut to length, bent to shape reqd, incl cranking, bending, spirally for hooping, hooking ends and binding with 0.90 mm dia MS wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed.
425
-
-
M&L for rolled mild steel section as in main and cross beams, hip and jack rafters, purlins or similar works posts where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates of Fe 410-W Gde E-250) quality A complete all as specified and directed.
615
-
-
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
70
-
-
S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. cut to ordinary lengths as per requirements of Fe 410 (Gde E250) quality A complete all as specified and directed.
100
-
-
M&L for coloured non skid ceramic tiles 7 to 8 mm thick joint less (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor etc set and jointed in neat cement slurry and pointed with white or coloured cement to match with the shade of tiles over & including 15 mm thick screed bed in cement mortar 1:6, including dismantling of existing floor tiles complete all as specified and directed.
25
-
-
M&L for glazed ceramic designed coloured tiles 300 x 450 mm x 7 mm/ 450 x 350x 7 mm thick on vertical surface such as dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including 10 mm thick rendering in cement mortar 1:4, including dismantling of existing tiles/taking down of plaster complete all as specified and directed.
180
-
-
Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level) (unreinforced) complete all as specified and directed.
16.5
-
-
M&L for 25 mm thick PCC 1:2:4 type B0 (using 12.50 mm graded stone agg) as in flooring finished even & smooth without using extra cement, complete all as specified and directed.
510
-
-
M & L for vitrified colour tiles of 10mm thick first quality (square / rectangular) polished, area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm as in floor etc set and jointed in neat cement slurry and pointed with coloured cement to match the colour of tiles over and including 20 mm thick screed bed in CM 1:6, complete all as specified and directed.
360
-
-
M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like bedded over and including 20 mm thick screed bed in CM (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
35
-
-
M&L for machine cut, mirror polished grey colour kota stone slab as in flooring and trades of steps 18-25 mm thick (square/rectangular area of each slab exceeding 0.30 sqm) over 20mm thick screed in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and marble stone border complete all as specified and directed.
150
-
-
M&L for machine cut, mirror polished grey colour Kota stone slab as in riser of steps, skirting, dado & pillar of 18-25mm thick (area of each slab as per site requirement) over 10mm thick plater in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed.
18
-
-
Labour only for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
20
-
-
Taking down chowkhats with shutters (without taking down of shutter from the frames) exc 1.50 Sqm and not exc 4.00 Sqm each complete all as specified and directed.
21
-
-
Taking down chowkhats with shutters (without taking down of shutter from the frames) not exc 1.50 Sqm each complete all as specified and directed.
27
-
-
Taking down shutter of any description not exc 1.00 Sqm each complete all as specified and directed.
2
-
-
Taking down shutter of any description exc 1.00 Sqm and not exc. 2 Sqm each complete all as specified and directed.
2
-
-
M&L for factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 60 x 75 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed.
72.8
-
-
S&F for factory made solid PVC moulded door shutter,with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC wooden finish colour sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing mention in SSR Part II complete all as specified and directed.
30.8
-
-
M&L for factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed.
75
-
-
S&F factory made pre-laminated PVC solid board 18-20 mm thick prelaminated on both sides with wooden finished on one side and white finished lamination on other side as in cup-board front shutters complete fixed in position complete all as specified and directed.
26
-
-
S&F Stainless Steel (304 Grade) finished butt hinges 100mm with stainless steel screws complete all as specified and directed.
120
-
-
S&F Stainless Steel (304 Grade) finished butt hinges 150mm with stainless steel screws complete all as specified and directed.
32
-
-
S&F Stainless Steel (304 Grade) finished square tower bolt 200mm long with stainless steel screws complete all as specified and directed.
48
-
-
S&F Hasp and staple 100 mm wide, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
16
-
-
S&F 150mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
60
-
-
S&F 150mm size aluminium anodised alloy handles fabricated type complete all as specified and directed.
60
-
-
S&F 300mm long mild steel, sliding door bolt, with hasp and staple (bolt type) cast or extruded section and fixing bolts of extruded section complete all as specified and directed.
19
-
-
S&F aluminium sliding windows with 50 micron powder coating, three track sliding windows with two glazed shutters, 5mm thick tinted glass selected quality and one shutter of stainless steel wire mesh 0.36mm nominal dia of wire and average width of aperture 1.40mm including good quality of bearing handle, locks, rollers, including EPDM gasket to render the glazing, air and water tight etc.. complete all as specified and as directed. catalouge numbers of Jindal company or equivalent make as specified. Sections of Jindal company : Three track bottom - 20957, Three track top/vertical-20958, handle-20606, Interlocking-20605, Top/ Bottom/sides for shutter section- 20604
20
-
-
M&L for extruded aluminium ventilators with 50 micron powder coating of frame of 63.5 X 38.10 X 1.29 mm including 5mm thick frosted glass in lower 55% portion of opening and stainless steel wire gauge 0.36mm dia and 1.40 aperture in upper 45% portion of opening, including fixing of frosted louvers glass close and open operationable with frame and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. or using aluminium beeds 20mm size complete all as specified and directed.
2.4
-
-
S&F for framed work as in doors chowkhats or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe-290 (Gde E165) complete all as specified and directed.
65
-
-
S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
6
-
-
S&F for framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
400
-
-
S&F in repairs for Vitreous China wash down water closet pan semi-pedestal pattern (Anglo-Indian Type), white (including fixing bolts,flush pipe) front or back inlet including plastinc water closet seat cover closed pattern with flat bottom and connection to drain (or outgoing pipe) and to flushing pipe, etc and making good to floor complete all as specified and directed.
3
-
-
S&F in repair for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
3
-
-
S&F in repair, vitreous china under counter wash basin, size 575 x 430 mm, excluding taps, waste chain, plug and porcelain stopper, pillat tap (pillar tap measured and paid seprately) but including brackets, cutting for and pinning in ends of bracket or erecting stand complete all as specified and directed.
3
-
-
S&F Vitreous China urinals, bowl type (back or corner wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinalback in cement; fixing automaticflushing cistern with brackets,flush pipe, grating and Union for discharge pipe complete all as specified and directed. Note :-Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe.
2
-
-
S&F 15mm dia centre hole basin mixer, chromium plated, fancy type complete all as specified and as directed .
3
-
-
S&F in repair 15 mm Bib taps, cast copper alloy fancy type chromium plated with capstan head screwed down screwed for iron pipe of 15mm bore complete all as specified and directed.
6
-
-
S&F in repairs 15mm bore stop valve fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
12
-
-
S&F repairs 1200 mm x 600mm bevelled edge mirror with glass shelf assembly of selected quality glass , mounted on wall with SS mirror fixing cleats and PVC plugs with chromium plated brass screws and cup washers complete all as specified and directed..
3
-
-
S&F Vitreous china white soap dish 160x160mmx90mm size fixed to wall with plugs and screws complete all as directed and specified.
3
-
-
S&F in repair towel rail 450 mm long of PTMT fixed with and including Chromium plated brass screws and wooden / plastic cleats ( minimum weight 170 gms ) complete all as specified and directed.
3
-
-
S&F in new or old position 32mm bore PVC waste pipe for WHB or sink complete all as specified and directed.
3
-
-
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
9
-
-
S&F GI tubes of medium grade with all fitting and fixed complete to walls and ceilings or laid in floors of 15 mm dia including taking down existing line complete all as specified and directed.
50
-
-
S&F tubes medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floors 20 mm dia including taking down existing line complete all as specified and directed.
80
-
-
Taking down & Refixing of old steel tubing and connections in new or old position (walls, ceilings, floors, etc) of 15 mm bore complete all as specified and directed.
20
-
-
Taking down & Refixing of old steel tubing and connections in new or old position (walls, ceilings, floors, etc) of 20 mm bore complete all as specified and directed.
30
-
-
Cutting chases, pinning in, brick walls and making good to facing where required and pointing in CM (1:3) to ends or edges and making good cutting not exc 10 cm girth complete all as specified and directed.
45
-
-
M&L for 15 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe for concealed pipe lines in walls including taking down existing line complete all as specified and directed. (Note : The rates for pipes in RM including short lengths, with all pipe fittings such as ends, elbows, unions, tees, reducing tees, adoptors, sockets, plugs, hose clips etc)
45
-
-
S&F in repairs 100mm dia stainless steel gratings complete all as specified and directed.
6
-
-
S&F fix in repairs tripple layer 500 ltrs rotational moulded polyethlene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including flot valve complete all as specified and directed.
3
-
-
S&F in repairs sink made of stainless steel 1.00mm thick with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm X 420mm & bowl 410mm X 330mm X 160mm including PVC waste pipe complete all as specified and directed.
1
-
-
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggretgate) as in base for PVC tanks complete all as specified and directed.
1
-
-
S&F in repair 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for unions complete all as specified and directed.
3
-
-
S&F Cast iron soil, waste and vent pipe, Centrifugal type 100mm bore, spun cast in any length, with or without ears, with lead joints, fixed to walls with and including stack clamps, nuts , bolts etc. and making necessary connections including taking down of existing unserviceable pipe complete all as specified and directed.
18
-
-
S&F Cast iron soil, waste and vent pipe, Centrifugal type 100 mm bore, spun cast in any length, with or without ears, with lead joints, laid in trenches including necessary earth work including down of existing unserviceable pipe complete all as specified and directed.
12
-
-
S&F in repair cast iron branch pieces single Centrifugal type (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches, suitable for 100 mm bore pipe, fitted with oval access door jointed with lead joint, complete all as specified and directed.
3
-
-
S&F in repair CI Cowl centrifugal type suitable for 100 mm bore pipe complete all as specified and directed.
3
-
-
S&F in repair cast iron bends/Tee duck foot or heel rest, radius for 100 mm bore pipe, complete all as specified and directed.
6
-
-
S&F in repair Salt-glazed stoneware gully traps,centrifugal type 150x150mm size, square or round mouthed, type 'P' or 'S' incl CI grating complete all as directed and specified.
3
-
-
S&F in repairs 110mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls complete all as specified and directed.
110
-
-
S & F bend suitable for 110mm dia PVC (SWR) pipe including clamps complete all as specified and directed.
24
-
-
M&L 75mm thick PCC 1:3:6 type C2 (using 40mm graded agg) as in plinth protection paving etc, finished surface even and smooth without using extra cement including demolition of old existing cement concrete complete all as specifie and directed .
120
-
-
M&L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggretgate) as in sub base complete all as specified and directed.
140
-
-
M&L for machine pressed precast conctete interlocking paver block with grey cement and no pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade including 25mm thick sand cushioning complete all as specified and directed.
140
-
-
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint including one coat of red oxide complete all as specified and directed.
145
-
-
M&L for preparation of new wood surfaces of any description over 10cm width of girth applying two coats of synthetic enamel paint over coat of pink primer etc complete all as spcd.
20
-
-
M&L PCC ( 1:2:4) type B0, padding in averaging on RCC roof slab or terrace with using WPC @ 2% by mix weight of cement and finishing even and smooth with using extra cement including demolition of cement concrete (unreinforced ) above ground floors not exc 15cm thickness i.e from RCC roof slabs/terrace complete all as specified and directed.
5
-
-
M&L for provn of roof treatment with polymeric water proofing membrane shall be carriedout as given below including dismantling of existing roof treatment including tar felt, cement plaster, etc from roof surfaces including cleaning the surface and removing the debris from site complete all as specified and directed :-
(a) Screed bed or rendering 10 mm thick in averaging on RCC roof slab/parapet in cement mortar 1:3 mixed with and including liquid water proofing comound @ 200 ml per bag of cement finished even and smooth without using extra cement (b) Applying a coat of bituminous primer @ 0.30 Iit/sqm on prepared surface and allowed to dry.
(c) Applying a coat of hot blown bitumen 85/25 conforming to IS-702 @ 1.20 Kg/Sqm
(d) Applying water proofing treatment to roof including vertical surface with APP based polymeric membrane, 3 mm thick (min.) consisting of 90 to 100 micron thick central core of HMHDP film and standard weight of 3.00 kg/sqm reinforced with polyster non woven fabric (weighing not less than 160 gm / sqm), application of APP modified membrane and joint shall be sealed by torch application. The overlaps shall be both sides with 10 cm and 15 cm at longitudinal and transverse direction respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into groove on vertical plane and groove sealed with cement mortar 1:3.
Note : (i) Treatment shall be done through authorised representative of manufacturer. (ii) Rate of Water proofing compound shall deemed to be included under this item).
100
-
-
M&L for 40 mm thick locally available brick tiles laid over and including 15 mm thick screed in cement mortar 1:4 mixed with and including liquid water proofing comound @ 200 ml per bag of cement, grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement complete all as specified and directed. (Rate of Water proofing compound and crude oil deemed to be included under this item).
100
-
-
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 mixed with and including liquid water proofing comound @ 200 ml per bag of cement complete all as specified and directed. (Note :Rate of Water proofing compound deemed to be included under this item).
60
-
-
Excavation in trenches in hard/dense soil not exceeding 1.50 metre wide and not exceeding 1.50 metre deep for foundations pipe line etc or for shafts, wells, cesspits, manholes, pier holes etc and not exc 10 sqm on plan and not exceeding 1.50 metre in depth and getting out complete all as specified and directed.
48
-
-
Returning filling in, including speading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, in trenches, complete all as specified and directed.
40
-
-
Removing excavated soil to a distance not exceeding 50 metre and deposting where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
8
-
-
M&L for plain cement concrete (1:4:8), Type D-2, using 40 mm graded stone aggregate as in concrete bed to drain pipes laid to falls in trenches in any depth including packing under and hauncing against the sides of pipes for 150 mm bore pipes with concrete after the pipes are laid and tested complete all as specified and directed.
80
-
-
M&L for 150 mm bore, Salt glased stoneware drain pipes (Grade 'A') laid in trenches at any depth including jointing and testing complete all as specified and directed.
Note : Excavation & earth work & concrete for bed and haunching of pipe shall be measured and paid separately.
80
-
-
M&L for plain cement concrete (1:2:4) type B-2 using 40 mm graded stone aggregates as in surface channel/drains inside the manholes and like including weathering, sightly rounded or chamfered angles and throating as directed and provision of necessary formwork to any extent and finished exposed surface even and smooth without using extra cement complete all as specified.
1.4
-
-
M&L for PCC 1:3:6, type C-2 using 40 mm graded stone aggregate as in foundation,filling and mass concrete complete all as specified and directed.
9.7
-
-
M&L for plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in benching, coping, plinth course, bands stops etc incl necessary form works complete all as specified and directed.
5.75
-
-
M&L for Hard core of broken stone or boulders not exc. 63mm, deposited, spread, leveled in layers not exc. 15cm thick each layer including watering and well ramming to a true surface complete all as specified and directed.
6
-
-
S&F 12 mm thick semi-perforated micro tegular false ceiling at all heights with GRG (Glass Fibre With Semi With fully Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture design and patterns having moisture micro tegular edged or 1 0 mm content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-inCharge.
53
-
-
Taking down old unserviceable copper/aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators, sockets and defective main switch/DB/MCB/Metal plug etc. by unscrewing carefully from boards etc and making good disturbed surfaces of walls complete all as specfied and directed.
250
-
-
M & L for point wiring for light/fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH with and including PVC concealed conduit with all fittings including anodise press steel sunk box ISI marked bakalite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH as earth continuity conductor connected to common earth dolly in , cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified .Note: colour coding is to be maintained .
143
-
-
All as per srl item No 102 above but for call bell point complete all as specified and directed.
1
-
-
All as per srl item No 102 above but for 3 pin 5 amps socket outlet independent board complete all as specified and directed.
54
-
-
All as per srl item No 102 above but for 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed.
22
-
-
All as per srl item No. 102 here-in-before but wiring with 2.5 Sqmm for on independent board/two pin earth plug and socket including 2.5 Sqmm PVC insulated multi stranded unsheathed copper earth continuity conductor and connected to common earth dolly.
20
-
-
All as per srl item No.102 here-in-before but wiring with 4.00 Sqmm for on independent board/two pin earth plug and socket including 4 Sqmm PVC insulated multi stranded unsheathed copper earth continuity conductor and connected to common earth dolly.
10
-
-
S&F in replacement sheet metal single pole and neutral enclosure with socket, plug top complete with one single pole MCB of 20 Amps, 240 volts complete all as specified and directed.
10
-
-
S & F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed.
219
-
-
S & F bell push flush type 5 amps SP 240 volts complete all as specified and directed.
1
-
-
S & F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed.
20
-
-
S & F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed.
76
-
-
S & F socket outlet 2 in 1, 3 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
20
-
-
S & F bell AC , 230 VOLTS, single pole complete all as specified and directed.
1
-
-
S & F ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed.
26
-
-
S & F in replacement existing U/S light fitting with energy saving decorative LED batten 20 watt (4 Feet), 230 voltas, energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffusre & integrated electronic driver complete with all accessories prewired and includeing making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings. (Note power factor should not be less thtn 0.95) complete all as specified and directed.
79
-
-
S&F Recessed mounted energy efficient LED 2'x2' luminaire 34W ,840 direct -indirect soft line designed color temp 5700K, including constant current electronic driver suitable for false ceiling complete with all accessories prewired and connecting up with three core flexible copper conductor cable with suitable size complete including taking down existing unserviceable light fitting complete all as specified and directed.
22
-
-
S&F for replacement of existing unsv security light fittings with LED security light fitting 30/36 Watts, excellent thermally managed pressure die cast alumnium come with in-built photo sensor for automatic on/off, IP-66 including GI bracket made out of GI pipe 40 mm bore medium grade bent to an angle of 135 degree and reduced at the end to 32 mm dia, 1.20 mtr long including 2 Nos clamps, suitable size of nut, bolts complete all as specified and directed.
6
-
-
Supply and fixing BLDC 5 star ceiling fans complete with blade, down rods, electronic regulator and acessories, 26 watts, 230V, 1200mm sweep, Main delivery 210 CFM wwith service value five star rated complete all as directed.
26
-
-
S&F exhaust fan of 300mm sweep, AC single phase 230/240 volts, 1400 rpm steel body complete with louvers including making electric connection with PVC insulated three core 1.5 Sqmm copper cable from ceiling rose to exhaust fan, grouting anchor bolts/fastners including cutting and opening of hole for fixing of exhaust fan through wall, circular or rectangular in shape including making good the disturbed surface surrounding by plastering, finishing and colouring complete all as specified and directed.
9
-
-
S&F telephone jack RJ11 2 way including modular plate & frame as required at site complete all as specified and directed
2
-
-
S & F sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing complete all as specified and directed.
6
-
-
Supply and fixing factory made epoxy powder coated Distribution Board TP & N 8 way double door ( MCB DB ) MCB TPN as In comer & MCB's as out going with metal door (IP-43 protection, IK-09) as per IEC-61439 fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified and directed.
1
-
-
S & F MCB single pole 240 volts, 'C' curv of rating from 6 to 32 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed.
42
-
-
S & F MCB SPN 240 volts, 'C' curv of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
6
-
-
S & F MCB TPN 240 volts, 'C' curv of rating from 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
1
-
-
M & L for replacement of existing unsv submain wiring with two single core PVC insulated flexible copper conductor cable (FRLSH)of sze 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit light grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing complete all as specified and directed.
180
-
-
M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron Wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 15 mm GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level , GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing complete all as specified and directed.
2
-
-
Supply, fixing, laying & testing 40 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing including taking down existing GI tubing complete all as specified and directed. (Necessary earth work will be measured and paid seperately.
90
-
-
Supply, fixing, laying & testing 25 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing including taking down existing GI tubing complete all as specified and directed. (Necessary earth work will be measured and paid seperately.
60
-
-
S&F for 40mm bore Gun metal gate valves with iron wheel head screwed down both ends for iron pipes, complete all as specified and directed.
1
-
-
S&F for 25mm bore Gun metal gate valves with iron wheel head screwed down both ends for iron pipes, complete all as specified and directed.
1
-
-
Cutting of existing GI pipe of size 50 mm dia for taking brach connection and screwing including providing GI fittings as required at site complete all as specified and directed.
1
-
-
M&L for construction of valve chamber 900 x 900 x 900mm internal dimensions, 3 mm thick MS sheet cover with 2 Nos MS hinges welded to angle iron frame of 40 x 40 x 6 mm thick with lifting hook and locking arrangement with brass pad lock of 65 mm dia with triplicate keys complete with necessary earth work, brick work in CM (1:6), 230 mm thick, PCC bed (1:4:8) type D2 150 mm thick, cement plastering, finishing 15 mm thick in CM (1:4) and applying a coat of black bituminous paint to the steel surfaces complete all as specified and directed.
1
-
-
Supply, installation, testing and commissioing high wall spilt unit indoor & outdoor complete 2 TR/2.2, invertor technologhy, copper condenser in white colour single phase AC 230 Volts, 50 Hz, 5 Star rating and EER 5.2 with cordless remote control unit in built stablizer complete all as specified and directed.
Notes : - (a) Copper pipes with insulation should be 3mtr length and it should be OEM.
(b) Cost of rounded copper cable 2.5 Sqmm 4 core outdoor to indoor unit included in quoted rate.
(c) Indoor to socket cable lenght should be min 3 mtr. (d) Manufacturer warranty - 01 Year on product, 10 Year compressor and 5 Year PCB Warranty.
(f) Cost of MS stand for installation of outdoor unit shall be included in quoted rate.
(g) Civil work shall be included in quoted rates.
(h) Installation should be carried through OEM rep.
(j) Contractor should be sticke the black colour sticker of size 3 to 5 Cm "GE (AF) ADM AREA AGRA" on indoor and out door unit.
Make : O General Model No ASGG24CETA-B,/Daikin Air conditioning Model No JTKJ71UV16U/Carrier Model No 24K EMPERIA LXi INVERTER R32 SPLIT AC_CAI24ES5R32F0, Copper Condenser/ Haier Model No HS24E-TXS3BE-INV/HU24-3BE-INV, Copper Condenser).
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements