Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date11 Jan 2024
Closing Date15 Feb 2024
Tender Amount₹ 29,72,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No 1.00 above but capacity 4x80 TR at H No -07 Make Voltas complete all as specified and directed. Note: Inspection & servicing the complete airconditioning plant as above briefed in the Ser no:(i) to(xiv) is executed at site by the contractor in one time only within three month after issue of contract work order.

1

-

-

... More
All as per item No 1.00 above but Blue Star Make Chiller unit Model No -XWC3S-039AR2 -03 Nos 38 TR at H No-08 Plasma complete all as specified and directed. Note: Inspection & servicing the complete airconditioning plant as above briefed in the Ser no:(i) to(xiv) is executed at site by the contractor in one time only within three month after issue of contract work order.

1

-

-

... More
All as per item No 1.00 above but Blue Star Make Chiller unit Model No -XWC2YS-070AR3 -02 Nos 60 TR at New IRS AC Plant complete all as specified and directed. Note: Inspection & servicing the complete airconditioning plant as above briefed in the Ser No: (i) to(xiv) is executed at site by the contractor in one time only within three month after issue of contract work order.

1

-

-

... More
All as per item No 1.00 above but Blue Star Make Chiller unit Model No -XWC3S-042AR2 -02 Nos 50 TR at New IRS AC Plant complete all as specified and directed. Note: Inspection & servicing the complete airconditioning plant as above briefed in the Ser No:(i) to(xiv) is executed at site by the contractor in one time only within three month after issue of contract work order.

1

-

-

... More
All as per item No 1.00 above but Blue Star Make Chiller unit Model No -XWC4S-052AR2 -01 Nos 50 TR at Old IRS Chilling plant complete all as specified and directed. Note: Inspection & servicing the complete airconditioning plant as above briefed in the Ser No:(i) to(xiv) is executed at site by the contractor in one time only within three month after issued of contract work order. Note for Serial item No 1.00 to 8.00:- (i) The rates quoted shall also include the attending of emergency breakdowns in AC plants. If such emergency breakdowns are not attended in time, following compensation shall be levied from the contractor's dues: (a) Attending breakdown within 72 hours - Rs Nils (b) Attending breakdown within 3 to 7 days - Rs 10000 per breakdown. (c) Attending breakdown after 7 days - Rs 25000 per breakdown. (iii) Spare parts required shall be measured & paid separately under relevant items of BOQ based on their consumption on ground.

1

-

-

... More
Supply installation, testing & commissioning following Spare in replacement for running of the plants of capacity as per serial No 1.00 to 8.00:- PLC Controller

4

-

-

... More
Temp sensor

4

-

-

... More
Pressure Transducer

4

-

-

... More
Expansion Valve

4

-

-

... More
Pressure difference switch

4

-

-

... More
Pressure relief valve

4

-

-

... More
Filter drier

4

-

-

... More
Oil Transducer

4

-

-

... More
Solenoid valve coil

4

-

-

... More
Crank case Heater

4

-

-

... More
Motor Protection Device

4

-

-

... More
Transformer of chiller unit

4

-

-

... More
Voltage protection relay

4

-

-

... More
Microprocessor

4

-

-

... More
Supply and Fix in replacement of dry filter 1/2" complete all as specified and directed.

5

-

-

... More
Supply and Fix in replacement of optical oil level switch complete all as specified and directed.

5

-

-

... More
Supply and Fix in replacement of oil filter as per sample complete all as specified and directed.

4

-

-

... More
Supply and Fix in replacement of outer gasket- oil filter RE-550 as per sample complete all as specified and directed.

4

-

-

... More
Supply, filling / top up of compressor oil SOLEST-120 suitable for AC plant of any cap including cleaning of oil chamber of AC Plant complete all as specified and directed.

100

-

-

... More
Supply and Fixing in replacement of Discharge Pressure switch as per existing make and model complete all as specified and directed.

3

-

-

... More
Supply and Fixing in replacement of Suction pressure switch as per existing make and model complete all as specified and directed.

3

-

-

... More
Taking out all old unserviceable sprinkle hub assy with blade & Supply & Fix in replacement of metal casting sprinkler hub assy with blade for cooling tower of cap up to 200 TR complete all as specified and directed.

3

-

-

... More
Supply and Fix in replacement of Flow Switch as per existing make and model complete all as specified and directed.

3

-

-

... More
Supply and Fix in replacement NRV valve of 50mm dia, cast iron body, wafer type integrally molded close and body construction with hand lever operated and rating of PN - 10 with thermal insulation as per requirement of chilled water line complete all as specified and directed.Make: Advance/Castle/Intervalve/SAAPL or equivalent as per Appx 'B' of Particular Specifications.

2

-

-

... More
Supply and Fix in repair NRV valve of 100mm dia, cast iron body, wafer type integrally molded close and body construction with hand lever operated and rating of PN - 10 with thermal insulation as per requirement of chilled water line complete all as specified and directed.Make: Advance/Castle/Intervalve/SAAPL or equivalent as per Appx 'B' of Particular Specifications.

1

-

-

... More
Supply and fix in replacement of V belt suitable for AHU complete all as specified and directed.

30

-

-

... More
Servicing of cooling coils and air filter of AHUs installed at air conditioning plant by removing air filters and fixing back after cleaning with air blower, water and cleaning agent, cleaning of cooling coil with wire brush and air blower and water spray pump after spraying scal gun AL or equivalent chemical suitable for aluminum fins and straightening the fins of cooling coil using suitable brush, cleaning of bottom tray, drain pipe complete one coat of painting with synthetic enamel paint after rubbing of existing surface and applying one coat of primer inside and outside ccomplete all as specified and directed.

12

-

-

... More
M&L for disconnecting electric connection & dismentling of electric motor upto 10 HP for rewinding of electric motor (Burnt stator) of any make & type of Compressor/pump/ AHU/ blower/CT fan motor of with suitable gauge of super enameled copper conductor including winding with fiber cloth/PVC insulated winding paper, superior quality varnishing, servicing of ball bearing, suitable main connections from coil to terminal box including M&L for disconnecting US burnt motor from the existing location, transporting to workshop and opening of motor, cutting/removing old burnt winding coils, cleaning/filing the starter slots, necessary mechanical works for shaft/bearing housing, preparing and inserting coils running/starting winding, interconnecting, fixing, soldering, jointing, heating, drying up coils, connection at site, to and from transportation, testing at site, replacing new connection terminal plate of following sizes satisfactorily running complete all as specified & directed

2

-

-

... More
All as per item No 23.00 above but Electric 15 HP.

2

-

-

... More
All as per item No 23.00 above but Electric 20 HP.

1

-

-

... More
Repair and Maintenance of Centrifugal / Monoblock pump sets of capacity up to 5 HP capacities installed at various AC plants by opening, checking for faults, filling of new graphite gland packing, fixing and replacement of unserviceable parts and reassembling after repair and testing complete of following capacities of pumps sets complete complete all as specified and directed:-

6

-

-

... More
All as per item 26.00 above but Pump of capacity 10 HP.

1

-

-

... More
All as per item 26.00 above but Pump of capacity 15 HP.

4

-

-

... More
Supply and Fix in replacement strip heater of capacity 3 KW, AC single phase heater bank 36 KW for winter heating including taking out old unserviceable strip heater complete complete all as specified and directed.

3

-

-

... More
Supply and Fix in replacement MCB 6 Amps, SP and breaking capacity 10 KA complete all as specified and directed.

4

-

-

... More
Supply and Fix in replacement MCB 40 Amps TP and breaking capacity 10 KA complete all as specified and directed.

4

-

-

... More
Supply and Fix in replacement MCB 63 Amps TPN and breaking capacity 10 KA complete all as specified & directed.

4

-

-

... More
Supply and Fix in replacement AC Control Power Contactor 3TF49 suitable for 100 TR compressor (110V-AC Coil Voltage) complete all as specified and directed.

4

-

-

... More
Supply and Fix in replacement AC Control Power Contactor 3TF46 suitable for 50 TR compressor (110V-AC Coil Voltage) complete all as specified and directed.

4

-

-

... More
Supply and Fix in replacement of power contractor MNX 32 with NO NC axuilary contactor of model MNX A2 or equivalent model complete all as specified and directed. Make: L&T / ABB / Siemens / C&S or equivalent as per Appx 'B' of Particular Specifications.

2

-

-

... More
Supply and Fix in replacement of power contractor MNX 25 with NO NC axuilary contactor of model MNX A2 or equivalent model complete all as specified and directed. Make: L&T / ABB / Siemens / C&S or equivalent as per Appx 'B' of Particular Specifications.

2

-

-

... More
Supply and Fix in replacement of power contractor MNX 18 with NO NC axuilary contactor of model MNX A2 or equivalent model complete all as specified and directed. Make: L&T / ABB / Siemens / C&S or equivalent as per Appx 'B' of Particular Specifications.

2

-

-

... More
Supply and Fix in replacement of power contractor MNX 12 with NO NC axuilary contactor of model MNX A2 or equivalent model complete all as specified and directed. Make: L&T / ABB / Siemens / C&S or equivalent as per Appx 'B' of Particular Specifications.

4

-

-

... More
Supply and Fix in replacement of pre-filters of exiting size complete all as specified and directed.

4

-

-

... More
Supply and Fix in replacement of MCCB 800 Amps, TP+NL 50 KA, 415 volts 50 Hz including necessary connection for incoming/outgoing with lugs of suitable size complete all as specified and directed. Make: L&T / Legrand / CG / C&S / Schneider or equivalent as per Appx 'B' of Particular Specifications.

1

-

-

... More
Supply and Fix in replacement of adjustable type MCCB 200 Amps TP, 36 KA, 415V, 50 Hz including necessary spreaders link for incoming/outgoing with lugs of suitable size complete all as specified and directed.Make: L&T / Legrand / CG / C&S / Schneider or equivalent as per Appx 'B' of Particular Specifications.

2

-

-

... More
All as per item 41.00 above but of 100 Amps TP 16 KA, 415 V, 50 Hz

2

-

-

... More
Supply and Fix in replacement of 200 Amps connector suitable for LT panel complete all as specified and directed.

2

-

-

... More
Supply and Fix in replacement of 100 Amps TPN isolator suitable for LT panel complete all as specified and directed.

2

-

-

... More
Supply and Fix in replacement of kit kat fuse unit upto 100 Amps suitable for LT panel complete all as specified and directed.

2

-

-

... More
Supply and Fix in replacement of electronc timer suitable for AC plant upto 100 TR complete all as specified and directed.

4

-

-

... More
Supply and Fix in replacement of single phase preventer VSP complete all as specified and directed.Make:- Minilec / L&T / Legrand / Siemens or equivalent as per Appx 'B' of Particular Specifications.

4

-

-

... More
Supply and Fix in replacement of ON/OFF Push switches complete all as specified and directed.

30

-

-

... More
Supply and Fix in replacement of ammeter flush type 96X96 sqmm, 5A class 1 with suitable fixing arrangement and CT coil for easily fixing in existing LT panel including necessary wiring complete all as specified and as directed.

4

-

-

... More
Supply and Fix in replacement of voltmeter flush type 96X96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring complete all as specified and as directed.

4

-

-

... More
Supply and Fix in replacement of galvanized steel tubes medium grade (ISI marked) of size 15 mm including all fittings and testing complete all as specified and as directed. Make: Jindal / Tata / Prakash Surya or equivalent as per Appx 'B' of Particular Specifications.

15

-

-

... More
All as per item 51.00 above but of size 20 mm.

15

-

-

... More
All as per item 51.00 above but of size 50 mm.

15

-

-

... More
Supply and Fix in replacement of Gun metal gate valves with iron wheel head screwed both ends for iron pipe of size 25 mm and fixed including testing complete all as specified and as directed. Make: Kartar / Zoloto / L&T /Upadhyay

2

-

-

... More
All as per item 54.00 above but of size 40 mm.

2

-

-

... More
Supply and Fix in replacement of 25/20 mm bore PTMT PVC float valve high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.Make: Kartar / Zoloto / L&T /Upadhyay/ Prayag or equivalent as per Appx 'B' of Particular Specifications.

2

-

-

... More
Supply, laying or fixing in replacement MS Pipes of sizes 50 mm dia heavy grade with all fittings laid in floors or fixed to walls and ceilings complete all as specified and as directed.Make: Jindal / Tata / Prakash Surya or equivalent as per Appx 'B' of Particular Specifications.

20

-

-

... More
All as per item 57.00 above but of size 80 mm.

10

-

-

... More
All as per item 57.00 above but of size 100 mm.

10

-

-

... More
All as per item 57.00 above but of size 150 mm.

10

-

-

... More
Supply and Fix in replacement of 80 mm dia butterfly valve with nuts, bolts, washers and rubber packing etc. complete all as specified and as directed. Make: Castle/Advance /Castle/Intervalve/SAAPL or equivalent as per Appx 'B' of Particular Specifications.

2

-

-

... More
All as per item 61.00 above but of size 100 mm.

2

-

-

... More
All as per item 61.00 above but of size 150 mm.

2

-

-

... More
Supply and Fix in replacement of 100 mm dia Non return Valve as per IS 5312 PN 1.6 including nuts, bolts, washers, gasket etc. complete all as specified and as directed. Make: Kartar / Zoloto / L&T / Upadhyay/Castle or equivalent as per Appx 'B' of Particular Specifications.

2

-

-

... More
Supply and charging gas nitrogen in returnable cylinder (sealed) for leakage pressure test of AC Plant (Element of charging and destroying and flushing out of blockage elements from cooling coil/suction discharge line and entire cycle of refrigeration system is included in respect item of repair work complete all as specified and as directed.

15

-

-

... More
Supply and charging of refrigerant gas R-22 in company sealed cylinder after making system leak proof complete all as specified and as directed. Make: Mafron / Freon / Refron or equivalent as per Appx 'B' of Particular Specifications.

240

-

-

... More
Supply and charging of refrigerant gas R-134A in company sealed cylinder after making system leak proof complete all as specified and as directed. Make: Mafron / Freon / Refron or equivalent as per Appx 'B' of Particular Specifications.

120

-

-

... More
Supply and charging of refrigerant gas R-407 in company sealed cylinder after making system leak proof complete all as specified and as directed. Make: Mafron / Freon / Refron or equivalent as per Appx 'B' of Particular Specifications.

240

-

-

... More
Supply and replacing new PVC fills into the cooling tower including taking out all old US PVC fills from cooling tower of capacity up to 200 TR complete all as specified and directed.

600

-

-

... More
Supply and Fix in replacement of siphon (as per sample) in existing line including cutting and welding of new socket/adopter complete all as specified and as directed. Note:- Cost of new socket and welding work and making good to existing pipe is deemed to be included in unit rate quoted.

10

-

-

... More
M&L for dismentle unserviceable compressor of make & model as given here after,disconnecting all electric connection carefully & pipings and then opening suction/discharge liquid line, gauge line etc including pumping down refrigerant gas to existing condensers / empty cylinder . Taking out old compressor oil in empty barrel & transporting compressor to contractor workshop for dismanteling and opening of compressors, checking each part of compressors i.e crank shaft, bearings, piston rings, suction/discharge reeds, guide assembly, oil pump assembly, shaft seal assembly for its servicieability,fixing/replacement of old serviceable/ New/Worn out part cleaning and polishing of all metalic parts, oil chambers, re-assembling of compressor,installation back on foundation connecting complete with existing system & making all electric & piping connection than testing of pressure by applying dry nitrogen, vaccum test and recharging of exsting of stored gas to the compressor and testing of unit complete all as specified and directed by engineer-in-charge at site. Voltas, Model 5H-40 H No-07 Chiller plant & AC plant Note: 1- Spare parts shall be measured and paid separately. 2. Grinding and polishing of shaft and Nitrogen leak testing will be measured and paid separately.

3

-

-

... More
Supply, installation, testing & commissioning following Spare in replacement :- (a) Main bearing seal end

2

-

-

... More
(b) Main bearing pump end

2

-

-

... More
(c) Connecting rod assembly

4

-

-

... More
(d) C R bearing

6

-

-

... More
(e) Cylinder Sleeve

8

-

-

... More
(f) Piston

8

-

-

... More
(g) Oil pressure release valve

8

-

-

... More
(h) Suction Valve reed

2

-

-

... More
(j) Oil filter assembly

2

-

-

... More
(k) Piston ring set

8

-

-

... More
(l) Aluminium washer set

4

-

-

... More
(m) Gudgeon Pin

8

-

-

... More
(n) Gudgeon pin Bush

8

-

-

... More
(o) Discharge valve assembly

10

-

-

... More
(p) Oil pump Assembly

1

-

-

... More
(q) Rocker for unloading mechanism

10

-

-

... More
(r) Piston Circlip

8

-

-

... More
(s) 'O' Ring set with tefelon set

4

-

-

... More
(t) Liner unloading Ring with Spring & Pin

4

-

-

... More
(u) Connecting rod nut & bolt

4

-

-

... More
(v) Retaining spring

32

-

-

... More
(w) Suction retaining plate

8

-

-

... More
(x) Safety valve

2

-

-

... More
(y) Gasket set complete

2

-

-

... More
(z) Discharge Service Valve

1

-

-

... More
(aa) Suction Service Valve

2

-

-

... More
(ab) Cylinder Liner

8

-

-

... More
(ac) Unloader Sleeve

2

-

-

... More
(ad) Valve Lifter Pin

24

-

-

... More
(ae) Valve lifter pin spring

24

-

-

... More
(af) Valve Plate

4

-

-

... More
(ag) Suction Valve spring

4

-

-

... More
(ah) Discharge valve guide assembly

24

-

-

... More
(aj) Seal End washer

2

-

-

... More
(ak) Seal End Thrust washer

2

-

-

... More
(al) Shaft seal cover plate

2

-

-

... More
(am) Suction Filter

2

-

-

... More
(an) Heater

2

-

-

... More
(ao) Pump End Thrust washer

2

-

-

... More
(ap) Oil filter Screen

1

-

-

... More
Repair & maintenance of FRP cooling tower, complete cleaning of cooling tower basin, PVC headers, PVC nosel fills, rearranging of PVC fill block old/new including repairing of leakage of suction and discharge line and replcement of broken header and PVC nozzales. Capacity 100 TR of central AC plant by taking down electric motor, fan blade, PVC fills and iots reinstallation complete at (H.No7 AC & chilling plant)

3

-

-

... More
All as per item No 73.00 above but capacity 38 TR (H.No 8 Plasma)

1

-

-

... More
All as per item No 73.00 above but capacity 20 TR (Red Barron)

1

-

-

... More
All as per item No 73.00 above but capacity 40 & 60 TR (old & New IRS))

2

-

-

... More
All as per item No 73.00 above but capacity 60 TR (Module 2)

2

-

-

... More
Material and labour for de-scaling of condenser of different capacity at various AC Plant location all as described as under : (i) Opening Block of condenser Inlet aned out let water pipe. (ii) De-Scaling of condenser tubes with de-scaling solution mixed with water by pump method for4 a duration of 08 hours continuous circulation. Note :- Cost of descaling solution is deemed to be included in quoted rates. (iii) Opening of bolts side condenser cover for following work:- (a) Cleaning of condenser fopper tubes carefully with condenser cleaning brushes to the entire satisfaction of Engineer-in-Charge. (b) Removing of rubber gasket of both side covers, preparing, new rubber gasket 6mm thick, fixing properly with existing bolts/nuts/Washers in following location of plant:- For Condenser of capacity 4x80 TR (H No 7 AC Plant)

4

-

-

... More
All as per item No 78.00 above but for Condenser of capacity 4x48 TR (H.No 7 chiller Plant)

4

-

-

... More
All as per item No 78.00 above but for Condenser of capacity 3x38 TR (H.No 8 Plasma)

4

-

-

... More
All as per item No 78.00 above but for Condenser of capacity 3x50 TR (IRS Chilling), 2X60 TR & 2X40 TR (IRS AC)

4

-

-

... More
All as per item No 78.00 above but for Condenser of capacity 3x20 Red Barron

2

-

-

... More
M&L for disconnecting crank shaft from the compressor, taking to workshop for recharging & machinarying/grinding to required shape to make the crank shaft manufacturing equivalent size to match with section bearings complete all as required & specified by Engr-In-Charge:- For crank shaft 5H-80 Series VOLTAS

1

-

-

... More
All as per item No 84.00 above but for Crank shaft 5H-40 Series VOLTAS

1

-

-

... More
Complete maintenance & overhaul of water softening plant installed at various location at Air Force stn. (i) Disconnecting existing water connection, remove old waste resin, sand & supporting media from the water softener plant. Clean the entire vassel from inside and outside with suitable cleaning agent. (ii) Scrapping of old existing paint, rust & salt formation from external & internal body of plant and preparing the surface for painting. (iii) Spray painting of internal body of plant with one coat of black bituminous paint (iv) Spray painting of external body of plant with two coats of synthetic enamel gray paint of complete all as specified and directed by Engr-in-Charge. (v) Replacement of relevant item will be measured and paid as under the respective item of schedule as under :- (a) Filter Sand for DMF - Approx 150 Kg and as per requirement of equipment. (b) Supporting media - Approx 200 Kg and as per requirement of equipment. (c) Anthracite - Approx 50 Kg and as per requirement of equipment. (d) Resin as per sample for Softener : Approx 200 Ltr and as per requirement of equipment. (vi) Testing & commissioning of water softening plant after maintenance complete up to entire satisfaction of AGE/GE.

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.