Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 Jan 2025
Closing Date22 Feb 2025
Tender Amount₹ 67,94,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No 2 here in before but for socket outlet 5 pin 5/6 Amp on independent board but not below the switch board, complete all as specified and directed by Engineer-in-charge.

163

-

-

... More
All as per item No 2 here in before but for socket outlet 6 pin, 15/16 Amp multi purpose, 2 in 1 on independent board with 2.5 Sqmm cable & including 2.5 sqmm single core multi stranded FRLSH copper earth wire to common earth, complete all as specified and directed by Engineer-in-charge.

122

-

-

... More
All As per item No 2 here in before but for bell/buzzer point, complete all as specified and directed by Engineer-in-charge.

18

-

-

... More
All As per item No 2 here in before but for one light point controlled by Two Two way switch, complete all as specified and directed by Engineer-in-charge. Notes for item No 2 to 7:- Whereever the wall surfaces disturbed due to cutting of wall for insertion of conduit that wall to be finished with cement mortar and putty to match with existing colour paint and rates are deemed to be included in the quoted rate.

19

-

-

... More
Supply and fixing modular Switch 1 way 6A ,1 module 240 volts AC ISI marked with suitable frame and covers with matching colours, complete all as specified and directed by Engineer-in-charge.

1138

-

-

... More
Supply and fixing modular Switch 1 way 16 A,1 module 240 volts AC ISI marked with suitable frame and covers with matching colours, complete all as specified and directed by Engineer-in-charge.

122

-

-

... More
Supply and fixing modular Socket 6 A-2/3 pin combined 2 module shuttered 240 volts AC ISI, marked with suitable frame and covers with matching colours, complete all as specified and directed by Engineer-in-charge.

263

-

-

... More
Supply and fixing modular Socket 6A/16A-2/3 pin combined,2 module 240 volts AC shuttered ISI marked, with suitable frame and covers with matching colours, complete all as specified and directed by Engineer-in-charge.

122

-

-

... More
Supply and fixing modular Bell push, piano flush type, 6 amp 240 Volts, with suitable frame and covers with matching colours, complete all as specified and directed by Engineer-in-charge.

122

-

-

... More
Supply and fixing modular Switch 2 way 6A, 1 module 240 volts AC ISI marked, with suitable frame and covers with matching colours, complete all as specified and directed by Engineer-in-charge.

38

-

-

... More
Supply and fixing ceiling rose surface type 65 mm x 50 mm, 2 to 3 terminal complete all as specified and directed.

752

-

-

... More
Supply and fixing modular type stepped type electronic fan regulator flush type 240volt on existing sheet, complete all as specified and directed by Engineer-in-charge.

67

-

-

... More
Supply and fixing Electric / Electronic Bell, Multi Music type 240 Volt AC supply, complete all as specified and directed by Engineer-in-charge.

18

-

-

... More
Supply and fixing Lamp holder of PVC/Polycarbonate type with back plate suitable for batten fitting including 9 watt LED bulb, complete all as specified and directed by Engineer-in-charge.

24

-

-

... More
Supply and fixing LED lights fitting 1x 20W, 240V,AC decorative box/ batten type with inbuilt driver white flux, , appx 4 feet long and connecting up with flexible copper conductor cable of suitable size from ceiling rose complete including taking down old unserviceable light fittings any type complete all as specified and as directed by Engineer-in-Charge.

595

-

-

... More
Supply and fixing LED mirror light fiting 10 watt, 6000K, linear & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete fitting with lamp and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector, complete including taking down old unserviceable light fittings any type complete all as specified and as directed by Engineer-in-Charge.

110

-

-

... More
Supply and fixing LED street light fitting 35 Watt 240 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp with suitable GI bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete for security light fitting fixing to wall/column & electrical connection to the light fitting providing 1.5 mtr long twin core round copper conductor cable of suitable size completeincluding taking down old unserviceable light fittings any type complete all as specified and as directed by Engineer-in-Charge.

23

-

-

... More
Supply and fixing in replacement of recessed LED ceiling lite with wide light window for maximized glare free output suitable for 600x600mm and ceiling cutout 595x595mm modular grid/POP ceiling complete fitting with separate electronic driver and high brightness SMD LEDs 36 watt, 6000K and one nos extra LED driver along the fittings including connecting electric connection, including taking down unserviceable old fitting any type complete all as specified and directed by Engineer-in-Charge.

32

-

-

... More
S&F in replacement LED light fitting 9W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete including taking down unserviceable old fitting any type complete all as specified and directed by Engineer-in-Charge.

16

-

-

... More
M & L for installation of new ceiling mounted saving energy switch which contains sensitivity detector, integrated circuit, gathers automatism, convenience, safety, saving-energy and practicality funtions. works by receiving human motion infrared rays, when one enters the detection field, start the load at once and identify automatically day and night with the adjustable on the sun and moon position along with delay timing of minimum 10 sec 3 sec and maximum 8 min 2 min including taking down unserviceable old fitting any type complete all as specified and directed by Engineer-in-Charge.

16

-

-

... More
Material and labour for sub main wiring with Two runs of single core PVC FRLSH IS-694 cable with colour code unsheathed multi-stranded copper conductor of size 4 Sqmm and drawing through in concelead rigid non metallic PVC conduit pipe 20 mm dia medium grade heavy duty with all necessary fittings including one run of FRLSH insulated unsheathed stranded copper conductor cable of size 4 Sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiring complete all as specified and as directed. Note : (i) Three run of 4 sqmm cable and one run of PVC conduit pipe shall be measured agaist one unit. (ii) Cost of cutting /chasing/ plastering /colouring etc to match with disturbed surface shall deemed to be included in the quoted rate.

760

-

-

... More
Material and labour for sub main wiring with Two runs of single core PVC FRLSH IS-694 cable with colour code unsheathed multi-stranded copper conductor of size 6 Sqmm and drawing through in concelead rigid non metallic PVC conduit pipe 20 mm dia medium grade heavy duty with all necessary fittings including one run of FRLSH insulated unsheathed stranded copper conductor cable of size 6 Sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiring complete all as specified and as directed. Note : (i) Three run of 6 sqmm cable and one run of PVC conduit pipe shall be measured agaist one unit. (ii) Cost of cutting /chasing/ plastering /colouring etc to match with disturbed surface shall deemed to be included in the quoted rate.

595

-

-

... More
Material and labour for sub main wiring with Two runs of single core PVC FRLSH IS-694 cable with colour code unsheathed multi-stranded copper conductor of size 10 Sqmm and drawing through in concelead rigid non metallic PVC conduit pipe 20 mm dia medium grade heavy duty with all necessary fittings including one run of FRLSH insulated unsheathed stranded copper conductor cable of size 10 Sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiring complete all as specified and as directed. Note : (i) Three run of 10 sqmm cable and one run of PVC conduit pipe shall be measured agaist one unit. (ii) Cost of cutting /chasing/ plastering /colouring etc to match with disturbed surface shall deemed to be included in the quoted rate.

460

-

-

... More
Material and labour for sub main wiring with Three runs of single core PVC FRLSH IS-694 cable with colour code unsheathed multi-stranded copper conductor of size 16 Sqmm and drawing through in concelead rigid non metallic PVC conduit pipe 25 mm dia medium grade heavy duty with all necessary fittings including one run of FRLSH insulated unsheathed stranded copper conductor cable of size 16 Sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiring complete all as specified and as directed. Note : (i) Four run of 16 sqmm cable and one run of PVC conduit pipe shall be measured agaist one unit. (ii) Cost of cutting /chasing/ plastering /colouring etc to match with disturbed surface shall deemed to be included in the quoted rate.

366

-

-

... More
S&F in replacement sheet of metal enclosures for MCB distribution board VTPN 6 way double door type including with MCCB 4 pole 125 Amps,16KA fixed type an incomer with 200 Amp rated bus bar complete all as specified.

8

-

-

... More
S&F in replacement sheet metal enclosures for MCB distribution board VTPN 6 way double door type including with MCCB 4 pole 100 Amps,16KA fixed type an incomer with 200 Amp rated bus bar complete all as specified.

8

-

-

... More
Supply and fixing metal enclosures made out of CRCA mild steel sheet, double door, powder coated DB TPN 4 way 415 Volt,(concealed in wall or as directed) dust and vermin proof suitable for incorporation of TPN upto 100 Amp and isolators etc., complete all as specified and directed by Engineer-in-charge.

8

-

-

... More
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 12 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DBs with its iron body covered box any type and size including MCB etc, taking down existing Electric meter from this iron box and arrangements of refixing these existing electric meter near this DBs, making good disturbed surfaces of walls as necessary with cement work complete all as specified and directed by Engineer-in-charge.

16

-

-

... More
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 8 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DBs with its iron body covered box any type and size including MCB etc, taking down existing Electric meter from this iron box and arrangements of refixing these existing electric meter near this DBs, making good disturbed surfaces of walls as necessary with cement work complete all as specified and directed by Engineer-in-charge. Common Notes for Item No 24 to 32 :- Where ever the wall surfaces disturbed due to cutting of wall for insertion of DBs, conduit and connected acessories, that wall surfaces to be finished with cement mortar , bricks and putty to match with existing colour paint and rates are deemed to be included in the quoted rate.

20

-

-

... More
Supply and fixing AC connection Box (Concealed with wall) single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts,, complete all as specified and directed by Engineer-in-charge. Note:- Whereever the wall surfaces disturbed due to cutting of wall for insertion of DBs and conduit that wall to be finished with cement mortar ,bricks and putty to match with existing colour and cement workand rates are deemed to be included in the quoted rate.

85

-

-

... More
Supply and fixing MCCB of capacity 125 Amp, Four pole , 415 volt, short circuit breaking capacity not less than 16KA , thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including thimbles, nuts, bolts, washers etc , MCCB fixing iexisting DBs/Panel board including making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge .

8

-

-

... More
Supply and fixing MCCB of capacity 100 Amp, four pole , 415 volt, short circuit breaking capacity not less than 16KA , thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including thimbles, nuts, bolts, washers etc , MCCB fixing in existing DBs/Panel board including incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge .

8

-

-

... More
Supply and fixing MCB TPN 100 Amps, 10 KA 'C' curve 230 V AC, 50 Hz including necessary attachment including taking down old unserviceable MCB SPN, complete all as specified and directed by Engineer-in-charge.

8

-

-

... More
Supply and fixing MCB SPN 63 Amps, 10 KA 'C' curve 230 V AC, 50 Hz including necessary attachment including taking down old unserviceable MCB SPN, complete all as specified and directed by Engineer-in-charge.

44

-

-

... More
Supply and fixing MCB SP suitable for 230 volts AC supply 40-63 Amps, rupturing capacity not less than 10KA,' B' Curve ISI Marked, 1 Module including taking down old unserviceable MCB SP, complete all as specified and directed by Engineer-in-charge.

168

-

-

... More
Supply and fixing MCB SP suitable for 230 volts AC supply 5/6 to 32 Amps, SP rupturing capacity not less than 10KA,' B' Curve ISI Marked, 1 Module including taking down old unserviceable MCB SP, complete all as specified and directed by Engineer-in-charge.

280

-

-

... More
Supply and fix exhaust fan 250mm sweep made of standard engineering plastic complete with louvers ,voltage 230V,50Hz,RPM 1200 copper winding including making suitable hole on wall and its finishing with cement work paint etc to match with existing surface and taking down existing outdated fans, depositing to E/M store all as specified and directed by Engr-in- Charge

20

-

-

... More
Supply and fix exhaust fan 300mm sweep made of steel body complete with louvers ,voltage 230V,50Hz,RPM 1200 copper winding and making suitable hole on wall and finishing with cement work paint etc to match with existing surface including taking down old outdated fans , depositing to E/M store all as specified and directed by Engr-in- Charge

4

-

-

... More
S&F storage type water heater (Geyser) electrical operated 230/240 Volts 50 ltr capacity, BEE 5 star rated complete with all safety equipment and accessories such as safety valve, thermostat, plug top, PVC connection pipe 600mm-02 nosetc. required for proper functionality & including electric/earth connections and carrying out grouting & complete installations with mounting bolts,nuts including testing after installation complete including taking down old rusted and outdated geyesers to be deposited to E/M store all as specified & directed by Engr-in- Charge.

16

-

-

... More
Taking down carefully serviceable ceiling fans and keep in safe custudy and to be done painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc, after completing the rewiring work refixing/hanging the ceiling fan and provision of connection flexible wire fom ceiling rose to fan all as directed by Engr-in- Charge.

67

-

-

... More
Supply and fix Shadow less light (OT Light) complete with emergency power unit & battery back up for min 30 minutes (3 KVA), having double dome of 810 mm dia, fully counter balanced moveable on ceiling trolley having a minimum longitudinal travel of 1350 mm and axial rotation of 360 degree. The unit to be suitable for operation on 230 V, single phase 50 cycles mains supply. (For Major OT having lux level 120,000) including taking down old set and depositing to E/M store all as directed by Engr-in- Charge.

3

-

-

... More
M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below normal ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts check nuts and GI washers earth plate surrounded by picked layer of coal dust and common salt 15cm thick all around bottom and top and watering pipe 20mm bore of GI pipe medium bore GI pipe light grade connected to funnel heavy wire mesh for watering purpose and 15mm bore GI pipe light grade for protection of galvanised earth wire from earth plate upto 7.5 metre and connecting to , main switch board including 10mm thick cast iron cover angle iron frame and PCC 1:2:4 type B-I for concrete pit, including necessary excavation and earth works etc , as shown in electrical plate No 3 of SSR Part - I of 2009 and testing on completion including taking down of existing earthing . Note : (i)PCC chamber shall be constructed at least 1.5m away from earth pit pipe for watering shall be provided in slanting manner.

16

-

-

... More
S&F for LT panel board outdoor type factory made and tested (CPRI approved) 415 volts 3 phase 4 wire 50 HZ AC supply having busbar chamber 400 Amps Aluminium strip TPN, installed on porcelain insulators, and copper conductor wiring , the panel shall be dust and vermin proof and made up of 3.15 mm CRCA mild steel sheet and 50x50x6 mm thick angle iron frame work , powder coated finish over one coat of red oxide primer out side and in side, front and rear opening type, with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor FRLSH cables, IS -694 marked of adequate size but not less than 4 sq mm and suitable to accomodate and including the following acessories:-

1

-

-

... More
(a) Aluminium bus bar of capacity 400 Amp for phase and neutral.

-

-

-

... More
(b) INCOMING :-

-

-

-

... More
(i) MCCB 4 Pole 250 Amps 36 KA -01 Nos.

-

-

-

... More
(c) Out going ;-

-

-

-

... More
(i) MCCB 160 Amps 4 Pole 25 KA adjustable type -02 Nos.

-

-

-

... More
(ii) MCCB 125 Amps 4 Pole 25 KA adjustable type -01 Nos.

-

-

-

... More
(iii) MCCB 100 Amps 4 Pole 25 KA adjustable type -01 Nos.

-

-

-

... More
(iv) MCCB 63 Amps 4 Pole 25 KA adjustable type -01 Nos.

-

-

-

... More
(v) Digital volt meter 0 to 500 volt with selector switch – 01 No

-

-

-

... More
(vi) Digital Amp meter 0 to 400 Amp with CT of suitable ratio and selector switch – 01 No

-

-

-

... More
(vii) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three

-

-

-

... More
(viii) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three

-

-

-

... More
Note : (i) Panel shall be mounted on brick work plat form duly plastered and PCC copping work on top surface , height shall be 0.60 m above the GL and 0.40 M all around the LT PB all as per direction of Engr-in-Charge.

-

-

-

... More
(ii) All incoming and out going cables shall be connected with suitable size of cable luggs and cable galands etc.

-

-

-

... More
Supply, installation, commissioning and testing of powder coated factory made panel board outdoor type CPRI approved confirming to IP 64 protection, of suitable size made of Robust steel sheet construction made from min 3.15 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate. The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:-

1

-

-

... More
(a) Aluminium bus bar of capacity 400 Amp for phase and neutral.

-

-

-

... More
(b) Incoming MCCB 4 pole 350 Amp 36 KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 02 Nos

-

-

-

... More
(c) Outgoing MCCB 4 pole 160 Amp 25KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 02 Nos

-

-

-

... More
(d) Outgoing MCCB 4 pole 100 Amp 16 KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 02 Nos

-

-

-

... More
(e) Outgoing MCCB 4 pole 63 Amp 16 KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 01 Nos

-

-

-

... More
(f) On load change over switch of capacity 400 Amp – 01 Nos

-

-

-

... More
(g) Digital volt meter 0 to 500 volt with selector switch – 02 No

-

-

-

... More
(h) Digital Amp meter 0 to 400 Amp with CT of suitable ratio and selector switch – 02 No

-

-

-

... More
(j) Phase Indicator Lamp RYB with sheds LED Type - 02 Set of three

-

-

-

... More
Note : (i) Panel shall be mounted on brick work plate form duly plastered and PCC copping work on top surface , height shall be 0.60 m above the GL and 0.40 M all around the LT PB all as per direction of Engr-in-Charge.

-

-

-

... More
(ii) All incoming and out going cables shall be connected with suitable size of cable luggs and cable galands etc.

-

-

-

... More
Supply, installation, commissioning and testing of powder coated factory made panel board floor mounted indoor type CPRI approved confirming to IP 64 protection, of suitable size made of Robust steel sheet construction made from min 2.10 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay and grouted on floor by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate. The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:-

2

-

-

... More
(a) Aluminium bus bar of capacity 500 Amp for phase and neutral.

-

-

-

... More
(b) Incoming MCCB 4 pole 350 Amp 50 KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 02 Nos

-

-

-

... More
(c) Outgoing MCCB 4 pole 200 Amp 36KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 01 Nos

-

-

-

... More
(d) Outgoing MCCB 4 pole 160 Amp 25 KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 04 Nos

-

-

-

... More
(e) Outgoing MCCB 4 pole 63 Amp 16 KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 02 Nos

-

-

-

... More
(f) On load change over switch of capacity 400 Amp – 01 Nos

-

-

-

... More
(g) Digital volt meter 0 to 500 volt with selector switch – 02 No

-

-

-

... More
(h) Digital Amp meter 0 to 400 Amp with CT of suitable ratio and selector switch – 02 No

-

-

-

... More
(j) Phase Indicator Lamp RYB with sheds LED Type - 02 Set of three

-

-

-

... More
S & F of MS busbar chamber wall mounted CPRI approved with min sheet thickness 2.10 mm wall mounted 6 Way outgoing type with proper indication bulb for three phase and suitable dimension duly provided with aluminium busbar with 200 Amp current capacity fixed on porcelain insulators TPN type weather/vermin proof duly provided with neoprene rubber gasket along the doors openings duly painted powder coated on CRCA steel sheet encloser with separate compartment for one No incomer MCCB 125 Amp 25 KA duly connected with busbars complete all as sepcified and directed.

12

-

-

... More
Excavation in trenches (soft & loose soil) n.exc. 1.5 m wide and n.exc.1.5m in depth for laying of UG Cable including getting out all as specified & directed by Engr-in-Charge

135

-

-

... More
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed.

55

-

-

... More
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc 1.5 m above starting point.

80

-

-

... More
M&L for spreading & leveling dry clean Ganga sand in trenches for cushioning UG cable complete all as specified and directed. Note:-Punned thickness shall be measured and paid.

40

-

-

... More
M&L for sub class old size of Brick in trenches for cable protection of LT Cables complete all as specified and directed.

4

-

-

... More
M& L for boring through existing road with trench less method for passing of UG cable all as specified and directed.

18

-

-

... More
M& L for cutting of floor/wall/road/footpath for laying of U/G cable of any size/description and making good the same as per existing specification after laying the cable all as specified & directed.

12

-

-

... More
Taking down old unserviceable cable of any size and discription as obtained from site complete all as specified and directed.

200

-

-

... More
Taking down old unserviceable busbar chamber of any size and description as obtained from site of any size and discription as obtained from site complete all as specified and directed.

4

-

-

... More
Taking down old unserviceable GI earthing of any type and description as obtained from site complete all as specified and directed.

4

-

-

... More
Supply and laying of XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 95 sq mm 3.5 core ,laid in trenches/ducts /encased in pipe/fixed in walls with nut bolts clamps all as specified and directed.

300

-

-

... More
Supply and laying of XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 35 sq mm 3.5 core ,aid in trenches/ducts /encased in pipe/fixed in walls with nut bolts caid in trenches/ducts /encased in pipe/fixed in walls with nut bolts clamps all as specified and directed.

560

-

-

... More
S&F,laying in trenches /fixed on pole / wall GI pipe of 80 mm dia light grade,IS-1239 marked with required size of flat iron clamp complete with bolts, nuts and washers of sizes 80 mm bore complete all as specified and directed.

24

-

-

... More
Supply & Fixing HDPE pipe of 40mm dia medium Grade for cable protection at wall including all fixing items clamps,nut bolts of suitable size complete all as specified and directed by Engr-in-Charge.

130

-

-

... More
M & L for Earthing complete with GI earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to GI strip of size 32x6 mm as earth lead up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates,40mm thick precast RCC cover in 1:2:4 reinforced with expanded metal(weight not less than 4 kg/sqm), and frame of angle iron 25x25x6mm with lugs 02 nos with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including light grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI earth wire protection pipe 40mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I , connected to earthing testing point and testing on completion complete all as specified and directed by Engr-in-charge.Note: (i) The unit rate includes GI pipe up to 7.5m for protection of earth lead.(ii) The unit rate includes main earthing lead/strip from earth electrode to test point up to 7.5 meter.

8

-

-

... More
M&L for earth continuity conductor or main earthing lead/strip fixed to wall or burried in ground or drawn in conduit (pipe/fixed to poles) of any type or any other situation for loop earthing etc with GI Strip of size 32 x 6mm complete all as specified and as directed by Engr-in-charge.

40

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.