Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date20 Mar 2024
Closing DateCancelled
Tender Amount₹ 31,50,000
Costs
EMD
₹ 63,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_647230_1Tender No
8748/BKT/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Taking down shutters of any description exc 1 sqm and not exc 2 sqm each complete all as specified and directed
10
-
-
... More
Taking down chowkats with shutter (without taking off shutter from the frame) exc. 1.5 sqm and not exceeding 4 sqm each complete all as specified and directed
7
-
-
... More
S & F 35mm thick, 2nd class HW, plain framed, factory made panelled shutter (two panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile should be as per IS:1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
18
-
-
... More
S & F IInd Class HW 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed
18
-
-
... More
S & F of factory made Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100mm x 8mm sheet metal CSK screws complete all as specified and directed. (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
25
-
-
... More
M&L for 30 mm thick flush shutters, solid core construction, with block board 3 core and plywood face panels, commercial type and laminate mat finish on both sides complete all as specified and directed.
7.5
-
-
... More
S & F of Factory made soild PVC profiled panel door shutter 28mm thick with integral skin as frame & 3mm thick high pressure compact laminate on both side of approved colour as infill, with 'C type Gl or 40mm x 20mm x19mm of MS pipe as stiffner & supplying & fixing in frame at site as per specifications & drawing complete all as specified and directed.
7.5
-
-
... More
S&F butt hinges 100mm size stainless steel complete all as specified and directed
15
-
-
... More
S&F butt hinge ISI Marked 100mm size, medium weight, cold rolled mild steel complete all as specified and directed.
60
-
-
... More
S & F 200mm long stainless steel ISI marked, barrel tower bolts of extruded section complete all as specified and directed
60
-
-
... More
S& F stainless steel ISI marked handles fabricated type anodised 150mm size complete all as specified and directed
60
-
-
... More
S & F 300mm long stainless steel ISI marked, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast pre extruded section and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed
12
-
-
... More
M&L for preparation of new surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying two coat of synthetic enamel paint,over one coat of pink primer complete all as specified and as directed
65
-
-
... More
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and directed
12
-
-
... More
Dismantling of floor hearth and wall tiling including mortar bedding removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
285
-
-
... More
M&L for Non Skid ceramic coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.06 Sqm but not exceeding 0.11 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed
35
-
-
... More
M&L for glazed ceramic coloured/printed tiles (colour & shade as approved by GE) of size 300mm x 450mmx 7-8mm thick in verticle surfaces as in skirting and dado set and jointing neat cement slurry, over & including 10mm thick rendering in cement mortar (1:4) and pointed, in white cement with pigment to match the colour of tiles complete all as specified and directed
60
-
-
... More
Taking down cement plaster on brick walls etc including racking out joints, hacking for keys in scrubbing down and washing with water etc complete all as specified and directed
710
-
-
... More
M&L for 15mm thcik rendering on fair faces of brick work in cement mortar (1:6) and finished even and smooth without using extra cement complete all as specified and directed
330
-
-
... More
Supply only Liquid water proofing compound complete all as specified and directed
21
-
-
... More
M&L for 15mm thcik rendering on other than fair faces of brick work in cement mortar (1:4) complete all as specified and directed
470
-
-
... More
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed
285
-
-
... More
M&L for applying two coats of oil bound distemper over a coat of primer on walls including preparation of new plastered surface complete all as specified and directed.
50
-
-
... More
M&L for preparation of old plastered surfaces of wall including cornices etc by brooming down or steel wire brushing scrapping down smoke soot moulds and efflorescent salt and trading oil and greasy spots and applying one coat of white wash of any colour complete all as specified and directed
650
-
-
... More
Ditto all as per item No-27 here in before but one coat of white wash on ceiling complete all as specified and directed
150
-
-
... More
M&L for preparation of old distempered surfaces of wall by washing rubbing down and stopping of old distempered surface of wall including cornices etc and applying 1mm thick of wall care putty as required for levelling and applying one coat of oil bound distemper (Oil emulsion any tint) on wall complete all as specified and directed
650
-
-
... More
M&L for preparation of old plastered or unplastered decorated surfaces of walls and applying one coat of cement base paint of any colour complete all as specified and directed
600
-
-
... More
M&L for preparation of old plastered or unplastered decorated surface of walls and applying one coat of weather proof paint (camouflage pattern) of any colour complete all as specified and directed
360
-
-
... More
M&L for preparation of old painted surface of wood or wood based material of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enemel paint complete all as specified and directed
65
-
-
... More
M&L for preparation of old painted steel surface of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
25
-
-
... More
Removal of complete existing water proofing membrane of any description on roof ( including taking down plaster/Demolition of cement concrete if any) surfaces of any description and roughening surfaces of old concrete floor by picking sweeping clean and washing down with water to remove dust, foreign items etc complete all as specified and as directed
150
-
-
... More
M&L for high performance waterproofing coating cold applied of spray/brush applied liquid membrance 1.5kg/sqm with an elongation of 600% and tensile strength of 12.6 n/sqmm as per ASTM D2370,crack bridging ability of 3.5mm as per ASTM C1305,shore a hardness of min 75 as per ASTM D2240. The system includes final base preparation as per site requirement,epoxy primer application and applying in two coats at a coverage of 1kg/sqm etc complete as per manufacturer specificationincluding removal of old waterproofing system and repairing and cleaning the surface complete all as specified and directed.
150
-
-
... More
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
156
-
-
... More
S&F Pre-painted galvalume aluminium zinc coating GI bases corrugatede steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /clading to fixed with self tapping screw complete all as specified and directed.
141
-
-
... More
S&F Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
15
-
-
... More
Demolition of brick work or stone/boulder masonary built in cement mortar of any specification and in any position complete all as specified and directed.
36
-
-
... More
M&L for Brick work with subclass `B' bricks (using old size bricks), straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed.
31
-
-
... More
Ditto all as per item No 40 above but except bricks complete all as specified and directed.
5
-
-
... More
M&L for PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in surface channels and drain, mass concrete and filling complete all as specified and directed.
6.5
-
-
... More
M&L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in surface channels, drain and finished even and smooth complete all as specified and directed.
6.5
-
-
... More
Demolition of Bricks (laid flat or on edge) as in channels , drain work built in cement mortar complete all as specified and directed
45
-
-
... More
M&L for bricks pointed in cement mortor (1:3) sub class 'B' old size bricks , laid flat as in drains complete all as specified and directed.
185
-
-
... More
Ditto all as per item No 45 but except bricks complete all as specified and directed.
85
-
-
... More
M&L for bricks pointed in cement mortor (1:3), sub class 'B' old size bricks , laid on edge in drains complete all as specified and directed.
100
-
-
... More
Ditto all as per item No 47 but except bricks complete all as specified and directed.
58
-
-
... More
M&L for cement concrete (1:2:4) type B-1, using 20 mm graded stone aggregate including use and waste of form work as in coping ,kerbss and similar articles including weathering ,slightly rounded or chamfered angles with plain faces complete all as specified and directed.
5
-
-
... More
Dismantling of posts or strutts (wood, steel or RCC) of any section, including taking out embeded portion in concrete, brick work, masonary etc and making good distrurbed surfaces complete all as specified and directed.
50
-
-
... More
Excavation in post holes each not exceeding 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good to distrurbed surfaces complete all as specified and directed.
50
-
-
... More
Fixing only chain link fencing including line wires, any mesh, size and type to any standards, rails, staining bolts, etc. including provision of binding wire etc complete all as specified and directed.
210
-
-
... More
Supply only chain link MS galvanised fencing any type and size complete all as specified and directed.
475
-
-
... More
S&F in repair galvanised, 2 strand, steel barbed wire of 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strainging bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc (each line wire to be measured) complete all as specified and directed.
8
-
-
... More
S&F in repair Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
450
-
-
... More
S&F in repair concertena coil as in fencing of 60 nos spirals shall be strached upto 8 mtrs dia of coil become 600 mm after straching the coil shall be hot drip galvanised with 0.50 mm thickness strip and 2.5 mm dia galvanised steel wire etc. complete all as specified and directed.
30
-
-
... More
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
12
-
-
... More
Returning filling in including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
12
-
-
... More
M&L for 600 mm bore reinforced concrete pipes , class NP3 with collar laid and jointed complete and fixed in travrse upto height of 5 meter and making joints complete all as specified and directed.
6
-
-
... More
Refixing of reinforced concrete hume pipes , class NP3, laid and jointed complete with collars including laying to level fixed in travrse upto height of 5 meter and making joints complete all as specified and directed.
2.5
-
-
... More
M&L for PCC (1:3:6) Type C-2 using 40mm graded stone aggregate as in bed to drain pipes including packing under, and hunching against the sides of pipes after they are laid and tested for 150mm bore pipe complete all as specified and directed
8.5
-
-
... More
M&L for arrangment of soft soil from out side of MoD land and forming embankments including raising (or lowering) earth, spreding in layers as required at site, watering, well ramming/rolling and finishing to required size, shape, etc not exc 5 mtr high from base as slope complete all as specified and directed.
400
-
-
... More
M&L for forming expansion joints 12mm thick filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound grade 'A' for thickness of concrete slab of 150mm thick after cleaning of surfaces complete all as specified and directed.
8
-
-
... More
M&L for 75mm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in plinth protection finished even & smooth without using extra cement complete all as specified and directed.
25
-
-
... More
M&L for Duracrete Chequred tiles of size 300mm x 300mm x 20mm thick, heavy duty laid over and including 25 mm thick PCC (1:2:4) Type B1 using 20mm graded stone aggregate and 15 mm thick screed bed in cement mortar (1:6) set jointed and pointed in neat cement slurry with white/grey cement mixed with admixture or pigment to match the shade of floors, and cut and polished complete all as specified and directed.
60
-
-
... More
Supplying and laying 50mm dia PVC pipe (LDPE) of rating 6kg/cm2 for Weep holes complete all as specified and directed.
25
-
-
... More
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil emulsion distemper and one coat of primer over and including 1mm thick wall care putty complete all as specified and directed
225
-
-
... More
M&L for preparing new by plastered surfaces of walls by affixing birla care wall putty rubbins to smooth finish and applying two coat of 100% premium acrylic emulsion Comouflaging pettern having VOC less than 50gm/Ltr and UV resitance as per IS 15489-2004 alkali and fungal resistance, dirt resitance exterior paint of required shade (company depot tinted) with silicon additives @1.43 ltrs/ 10 Sqm over and including priming coat of exterior primer applied @0.9 ltr/10sqm over new by prepare surface and height upto 9 meter complete all as specified and as directed .
Note: Primer and Emulsion to be carried out through air less spray machine (Mechanical Means)
250
-
-
... More
Supply & filling of baby chips of 6mm grade 40mm thick including spreading and levelling complete all as specified and directed.
13
-
-
... More
M&L for Petty repair works to internal electrification comprising of checking of nonfunctional existing electric circuits /wiring of light points/fan points/power points/energy meter etc and checking of fan/exhaust fan,switch/sockets ,DBS/MCCBs /MCB/ and other faults by deploying trained electrician with helper and tools and saftey equipments for continuous electric supply and carrying out minor repairs as required to make the items functional or to restore electric supply with and including tightening of lose and broken connections ,insulating naked wires ,opening of DBs etc and refixing the same after necessary repair.Replacing defective items provided under relevents items here-in-after with and including petty repairs of items/materials i.e. fuses thimbles small wires of any size screw washer nut bolt etc and cutting of backelite sheet for fixing accessories making all electric connections in Md/OTM Accn and in any location within tech area of GE(AF) BKT complete all as specified and directed
30
-
-
... More
Taking down caefully switch board complete with MS rectangular type box heavy duty from the existing position and supply & fix with suitable size of 8 to 12 module metal flush boxes and including modular front cover plate & back plate for mounting modular type switches /socket/fan/ regulator etc with making good the disturbed surface of wall with colour washing /distempering the surface to match the existing one complete all as specified and directed.
20
-
-
... More
Taking down caefully switch board complete with MS rectangular type box heavy duty from the existing position and supply & fix with suitable size of 4 to 6 module metal flush boxes and including modular front cover plate & back plate for mounting modular type switches /socket/fan/ regulator etc with making good the disturbed surface of wall with colour washing /distempering the surface to match the existing one complete all as specified and directed.
30
-
-
... More
Taking down caefully switch board complete with MS rectangular type box heavy duty from the existing position and supply & fix with suitable size of 1 to 4 module metal flush boxes and including modular front cover plate & back plate for mounting modular type switches /socket/fan/ regulator etc with making good the disturbed surface of wall with colour washing /distempering the surface to match the existing one complete all as specified and directed
30
-
-
... More
Supply & Fixing in repair Modular switch 1 way 6A 1 module type complete all as specified and directed
180
-
-
... More
Supply & Fixing in repair Modular switch 1 way 16A 1 module type complete all as specified and directed
40
-
-
... More
Supply & Fixing in repair Modular Socket 6A -3 pin 2 module complete all as specified and directed
40
-
-
... More
Supply & Fixing in repair Modular Socket 16A - 5 pin 2 module complete all as specified and directed
40
-
-
... More
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fitting and fixture and such as as switches, sockets ceiling rose,pendent holders,regulators,light fittings any type removing materials to store in safe custody or for credite etc, and making good the disturbed surface of walls and floors etc complete all as specified and directed
48
-
-
... More
M & L for point wiring with two single core PVC insulated & PVC unsheathed FRLS-H multistranded copper conductor cable of size 1.5 sqmm 1100 volt grade in and including making good the disturbed surface of wall with colour washing /distempering the surface to match the existing one in non metallic rigid PVC conduit medium grade 2 mm thick medium grade 20/25 mm dia with all accessories mounting all the surface of wall/ceiling/roof/etc with suitable size of 1 to 8 module metal flush boxes and including modular front cover plate & back plate for mounting modular type switches /socket/fan/ regulator etc including provision of one single core PVC insulated and unsheathed multi stranded copper cable of size 1.5 sqmm 1100 volt grade as earth continuty conductor connected to common earth dolly switch board complete all as specified and directed.
Note:- surface Conduit shall be laid in celing portion only.
16
-
-
... More
Ditto all as per item No 79 given here-in-before but for one bell point controlled by one 5 Amp bell push complete all as specified and directed
2
-
-
... More
Ditto all as per item No 79 given here-in-before but for point wiring for One 5 Amp socket point controlled by one 5 Amp switch on same board with cable 1.5 sqmm.
10
-
-
... More
Ditto all as per item No 79 given here-in-before but for point wiring for One 5 Amp socket point controlled by one 5 Amp switch independent board with cable 1.5 sqmm.
10
-
-
... More
Ditto all as per item No 79 given here-in-before but for with two single core PVC insulated & PVC unsheathed copper conductor FRLS-H cable of size 2.5 Sqmm 1100 volts grade and one single core PVC insulated &PVC sheathed solid copper conductor cable of size 2.5 Sqmm 1100 Volts grade as earth continuity conductor including PVC surface / concealed conduict of size 20 to 25 mm with all accessories for 3 pin 15 Amps socket point on independent board complete all as specified and as directed.
10
-
-
... More
S&F in repair decorative box type fitting for LED tube 16 to 22 watt luminaire for 230 volt AC,for LED tube 16 watt to 22 watt complete all as specified and directed
45
-
-
... More
S&F in repair for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 4 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multi standed copper conductor cable of size 4 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC concealed / surface conduit of not less than 25mm dia size on roof/wall/ceiling including making good the disturbed surfaces of wall etc including taking out old unserviceable burnt/damaged sub main wiring from its existing position complete all as specified and directed (Note : Two run of single core cable and one run of earth wire will be measured as one unit length, conduit and its accessories is deemed to be included in the quoted unit rate).
25
-
-
... More
S&F in repair for Submain wiring with 4 single core PVC insulated FRLS-H multistrand copper conductor cable of size 10 Sq mm drawn into and including non metallic heavy duty rigid PVC conduit not less than 25 mm dia ISI marked ivory colour (Pressfit or similar brand ) with all conduit fittings / accessories and 2 run single core 10 Sq mm FRLS-H multistrand copper conductor cable as continuous earth wire complete all as specified and directed. (Note for submain wiring: 4 run of single core cable and two run of earth wire and conduit pipe will be measured as one unit length and rate of conduit shall deemed to be incuded in quoted unit rate).
25
-
-
... More
Taking down old unserviceable main switches/DB’s up to 100 Amps capacity fixed in wall and making good of all disturbed surfaces as per existing .
7
-
-
... More
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 4 way, AC,240 volt with 200 Amp bus bar rating complete all as specified and directed
1
-
-
... More
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 8 way, AC,240 volt with 200 amp bus bar rating complete all as specified and directed.
2
-
-
... More
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 12 way, AC,240 volt with 200 Amp bus bar rating complete all as directed.
2
-
-
... More
S&F sheet metal enclosure double door (MCB DB) three phase and neutral with 200 Amps rated bus bar TPN, 4 way verticall type, with provision of MCB incommer, AC, 415 Volt complete all as specified & directed.
1
-
-
... More
S&F sheet metal enclosure double door (MCCB DB) three phase and neutral with 200 Amps rated bus bar VTPN, 4 way vertical type, with provision of MCCB incommer, AC, 415 Volt complete all as specified & directed.
1
-
-
... More
S&F MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified and directed
40
-
-
... More
S&F MCB Four Pole 40 to 63 Amps 415 Volts, 50 Hz, 10 KA breaking capacity complete all as specified and directed
1
-
-
... More
S&F MCB Four Pole 100 Amps 415 Volts, 50 Hz, 10 KA breaking capacity complete all as specified and directed
1
-
-
... More
Material, labour (Technician & Helper) and T&P including testing of equipments for carring outs comprehensive maintenance and testing of earthing any type as per existing procedure for lighting protection /eqpts/domestic etc in tech area & admin area by tightening of nut bolts arranging earth lead in allighnment manner replacing unservicable earthing lead ,funnel ,pit cover and PCC pits etc (which will be paid as supply only) and testing of earthing and recording result in register (as per procedure provided as directed ,If result found more than permissible limit reconditioning of earthing carried out by pouring water with salt /chemical as per direction and further testing the same earthing result and recordsing in register including levelling, refilling of earth settle down near pit complete all as specified and directed. Note-(i) Necessary compound required for recharging of earthing shall be measured and paid separately under relevant items given here-in-after.
(ii) During AMC of earthing , if any parts of the earthing is required to be replaced the same will be done by the contractyor as per directed by EIC . The cost of such parts shall deemed to be included in the unit rate quoted by th contractor for AMC.
(iii) Pouring of salt/chemical/charcoal water in the earth pit is included in the unit rate quoted the the contractor.
350
-
-
... More
M&L for chemical earthing by drillinmg hole of 100 mm dia and 4 mtr in depth in any kind of soil and providng 3.0 mtr long GI strip of size 32mm x 6 mm duly encapsulated in a medium grade galvenized steel of pipe of 88 mm OD and filling the hole with advance non toxic earth enhancing back fill compound quantity not less than 30 kg and water till complete soaking of chemical water mixture and providing a cylindrical type FRP earth pit chamnber of size 254mm dia at top and 330 mm dia at bottom and 260 mm height and 7.5 m long copper strip of sizxe 32 mm x6 mm as earth lead conductor duly protected with 65 mm bore medium grade GI pipe from terminal point to earth test point duly connected with terminal point through breezing and to connect with earth test point with brass bolt nuts and washer of suitable size and fixed on wall by mounting the strip of FRP /DMC bridge insulator and providng a test point a terminal block made of gun metal of phosphorus bronze of size 75 mmx75mmx25mm duly drilled and screwed and fixed on wall on insulators including 3 nos 8 mm dia 25 mm long having hexagonal haed brass scew complete with removing of excavated soil to a distance not excedding 50 meter and height not exceeding. 1.5 m from the starting point and testing on completion all as specified and directed.
Note- 1. Addl lenght of conductor beyond 7.5 mtr if required at site shal be measured and paid sperately undr respective item given here-in-after.
2.On testting afer completion of job if required earth resistance less than 5 ohm is not found the earthing shall be redone by the contractor & the cost of the same shall be borne by the contractor.
2
-
-
... More
M&L for chemical earthing by drillinmg hole of 100 mm dia and 4 mtr in depth in any kind of soil and providng a 3.0 mtr long pure copper strip 32mm x 6 mm duly encapsulated in a copper of pipe of 88 mm outer dimension and filling the hole with advance non toxic earth enhancing back fill compound quantity not less than 30 kg and water till complete soaking of chemical water mixture and providing a cylindrical type FRP earth pit chamnber of size 254mm dia at top , 330 mm dia at bottom and 260 mm height and 7.5 m long copper strip of sizxe 32 mm x6 mm as earth lead conductor duly protected with 65 mm bore medium grade GI pipe from terminal point to earth test point and duly connected with terminal point through breezing and to connect with earth test point with brass bolt nuts and washer of suitable size and fixed on wall by mounting the strip of frp /DMC bridge insulator and providng a test point a terminal block made of gun metal of phosphorus bronze of size 75 mmx75mmx25mm duly drilled and screwed and fixed on wall on insulators including 3 nos 8 mm dia 25 mm long hex haed brass scew complete with removing of excavated soil to a distance not excedding 50 meter and height not exceeding. 1.5 m from the starting p[oint and testing on completion all as specified and directed.
Note- 1. Addl lenght of conductor beyond 7.5 mtr if required at site shal be measured and paid sperately undr respective item given here-in-after.
2.On testting afer completion of job if required earth resistance less than 5 ohm is not found the earthing shall be redone by the contractor & the cost of the same shall be borne by the contractor.
1
-
-
... More
Supply & fixing copper strip of size 20 mm x 3 mm complete with saddles and fixing screws for fitting the strip for earth continuty conductor up to test points complete all as specified and as directed.
30
-
-
... More
M & L for Galvanised iron tubing, 40 mm bore,light grade with all fittings for fixed to pole/wall/ in ground including all fixing accessories for protection of earth strip complete all as specified and as directed.
20
-
-
... More
M & L for Test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25m long hexagonal head screw including connecting with earthing strip complete all as specified and directed.
10
-
-
... More
Material and labour for Alluminium earting strip of size 25mm X 3 mm including nesassary brazing and connecting existing earthing / lightening conductor system complete all as specified and directed.
50
-
-
... More
Material and labour for GI earting strip of size 25mm X4 mm including nesassary brazing and connecting existing earthing system complete all as specified and directed.
50
-
-
... More
Supply & Laying for 60mm thickness, M-35 Grade machine pressed precast concrete interlocking paver block of any shape and size jointing & painting with grey cement & pigment confirming to IS 15658-2006 complete all as specified and as directed
130
-
-
... More
M&L for pre-cast herb stone of PCC (1:2:4) Type B1 using 20mm graded stone aggregate complete all as specified and directed.
4.5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements