Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date11 Oct 2024
Closing Soon2 Dec 2024
Tender Amount₹ 54,98,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for opening the upper sheet and side sheet of AHU for access to cooling coil including for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing and changing of V Belt both set with necessary fitting and T&P for mounting for AC plant of capacity 3x37.5TR- Plant for OT Millitary Hospital , complete all as specified and directed .

2

-

-

... More
All as per Srl item No. 4.00 here-in-before but for AC plant of capacity 2x75TR-Plant for Selection centre, complete all as specified and directed .

2

-

-

... More
M&L for PCB Package AC plant of capacity 9 TR including in replacement of nut, bolt and other packing material etc; checking the proper electric connection, testing and commissioning for smooth operation at optimum efficiency for 803 FD Workshop, complete all as specified and directed .

4

-

-

... More
Taking out the existing unserviceable the item of packege AC 9 TR capacity, including cooling coil ,air filters,plasma filters etc (indoor uint), condenser, condenser ,fan motor etc electrical/electonic circuits realays,wiring kit,thermostats, swiches, knobs,remote control unit, including PCB , fan blower and refixing the same in ex position complete after replacement with supply and fixing meterial as following item no 7 to 17 complete all as specified and directed .

-

-

-

... More
Supply and fixing cooling coil of 4ft X 3ft , four row deep sutable for 9TR complete all as specified and directed .

2

-

-

... More
Supply and fixing of indoor air bolwer motor 9 TR capacity complete all as specified and directed.

2

-

-

... More
Supply and fixing cooper wounded condensor fan motor packege type AC of 9 TR Capacity out door unit complete all as specified and directed.

2

-

-

... More
Disconnecting the mains and taking out the UNSV condensor coil of packege type AC capacity of 9 TR any make form any location and supply fixing and testing new condenser coil as per exiting size and patterns for complete all as specified and directed.

2

-

-

... More
S&F condensor fan blade of alluminium for package type AC of capacity 9 TR as per Existing size complete all as specified and directed .

2

-

-

... More
S&F in repair of Expansion Valve for package type AC of capacity of 9 TR complete all as specified and directed . Make :- Danfos/Emerson/Temsuch

2

-

-

... More
S&F for Thermostate of package type AC capacity of 9 TR all as per existing, complete all as specified and directed .

2

-

-

... More
S&F in replacement of suction valve set of size 9.52 mm (3/8") for package type AC capacity 9 TR all as specified and directed . Note:- Supply and filling of refigerant gas shall be measured and paid under relevent items.

2

-

-

... More
S&F in replacement of discharge valve set of size 9.52 mm (3/8") for package type AC capacity of 9 TR all as specified and directed . Make :- LG/Voltas /blue star/Hittachi

2

-

-

... More
S&F for Cooling coil package type AC capacity 9 TR including cheking leaking welding and other packing material etc, testing and commissioning for smooth operation complete all as specified and directed .

2

-

-

... More
Removing burnt/defective sealed compressor unit of any make from any type of Package type AC capacity 9 TR by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply and fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc complete all as specified and directed .

2

-

-

... More
M&L for PCB Package AC plant of capacity 6 TR including in replacement of nut, bolt and other packing material etc; checking the proper electric connection, testing and commissioning for smooth operation at optimum efficiency, for 803 FD Workshop complete all as specified and directed. Make :- LG/Voltas /blue star/Hittachi.

2

-

-

... More
Taking out the existing unserviceable the item of packege AC 6 TR capacity, item including cooling coil ,air filters,plasma filters etc (indoor uint), condencer, condencer ,fan motor etc electrical/electonic circuits realays,wiring kit,thermostats, swiches, knobs,remort control unit, including PCB , fan blower and refixing the same in ex position complete after replacement wiht supply only meterial from item no 20 to 30 all as specified and directed.

-

-

-

... More
S&F cooling coil of 4ft X 3ft , four row deep sutable for 6TR complete all as specified and directed.

2

-

-

... More
S&F indoor air bower motor 6 TR capacity complete all as specified and directed.

2

-

-

... More
S&F cooper wounded condensor fan motor packege type AC of 6TR Capacity out door unit complete all as specified and directed.

2

-

-

... More
Disconnecting the mains and taking out the UNSV condensor coil of packege type AC capacity of 6TR any make form any location and supply fixing and testing new condercer coil as per exiting size and patterns for complete all as specified and directed.

2

-

-

... More
S&F condensor fan blade of alluminium for package type AC of capacity 6TR as per Existing size as specified and directed

2

-

-

... More
S&F in replacement of Expansion Valve for package type AC of capacity of 6TR complete all as specified and directed . Make :- Danfos/Emerson/Temsuch

2

-

-

... More
S&F Thermostate of package type AC capacity of 6TR all as per existing, complete all as specified and directed

2

-

-

... More
S&F in replacement of suction valve set of size 9.52 mm (3/8") for package type AC capacity 6 TR all as specified and directed . Note:- Supply and filling of refigerant gas shall be measured and paid under relevent items.

2

-

-

... More
S&F in replacement of discharge valve set of size 9.52 mm (3/8") for package type AC capacity of 6 TR all as specified and directed . Make :- LG/Voltas /blue star/Hittachi

2

-

-

... More
S&F Cooling coil package type AC capacity 6 TR including cheking leaking welding and other packing material etc, testing and commissioning for smooth operation complete all as specified and directed .

2

-

-

... More
Removing burnt/defective sealed compressor unit of any make from any type of Package type AC capacity 6 TR by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply and fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc complete all as specified and directed.

2

-

-

... More
M&L for dismantling of electric driven horizontal induction motor of capacity 20/25 HP of any type and make, by engaging sufficient man power and suitable T&P to ensure safety of motor including disconnecting of electric connections, dismantling of motor, taking out the burnt windings, cleaning and washing of slots and rewinding the same with copper winding wire of existing gauge and quantity (as per original manufacturer design) including replacement of all damaged parts i. e. bearings, bush, thrust plate, thrust bearing, connector plate, insulating materials such as insulating sheets insulating paper (Class "F"), sealing compounds etc and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc and reinstallation of the motor in original location, checking the alignment, making proper electric connection, testing for smooth operation, complete all as directed. Note : (i) The cost of winding wire and all replaced defective parts are deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. (ii) The cost of transportation (to and fro) and other necessary equipment shall be arranged/brought by contractor to complete the job at site or at repair shop and no extra cost shall be paid to the contractor in this effect.

5

-

-

... More
All as per srl item No 32.00 here-in-before but for 10/12.5 HP capacity complete all as specified and directed.

6

-

-

... More
All as per srl item No 32.00 here-in-before but for 5/7.5 HP capacity complete all as specified and directed.

4

-

-

... More
All as per srl item No 32.00 here-in-before but for 3.0 HP capacity complete all as specified and directed.

4

-

-

... More
M&L for complete overhauling of condenser / chiller centrifugal pumpset of 20 HP by engaging sufficient man power and suitable T&P to ensure safety of pump-motor as well as working persons including disconnecting suction & discharge water lines and removing of electric connection, dismantling the U/S pumpset from MS foundation, detaching the pump, opening the pump, remelting the shaft and filling of metal at decayed portions including all kind of machine works i.e. welding, turning, polishing etc as required to make the shaft of required shape and size, as original, balancing the shaft and refitting in pump body complete incl carrying out complete repair / replacement of damaged parts i.e. bearings, bush, gland plate, gland packing, coupling assembly etc and reassembling the pump after greasing of moving parts and reinstallation of the pump with motor in original location using new MS stud, nut, bolt, washer and other packing material etc; checking the alignment; reconnecting the suction and delivery pipes, making proper electric connection, testing and commissioning for smooth operation at optimum efficiency, complete all as specified and directed.

3

-

-

... More
All as per srl item No 36.00 here-in-above but for 10 /12 HP capacity complete all as specified and directed.

1

-

-

... More
All as per srl item No. 36.00 here-in-above but for 5 /7.5 HP capacity complete all as specified and directed.

2

-

-

... More
Overhauling, testing, and commissioning of open type reciprocating compressor 75 TR Capacity including dismantling and disconnecting suction and discharge refrigerant lines, other controls and accessories, loading, transporting to contractors workshop and back to plant room after necessary repairing and then reinstallation in its original position . Note :- (i) Replacement / renewal of minor items not covered in the succeeding items of Sch 'A' but essentially required for completing the Job i.e. gasket kits, cut washers, valve springs, castle nuts, etc shall be provided by the contractor and no extra payment shall be admissible on this account. (ii) Major items requiring renewal shall be measured and paid separately as supply only as given below.

1

-

-

... More
Supply only suction/discharge reeds for compressor of Make:-Blue Star, model No LCWR-1 - 075, 75 TR Capacity complete all as specified and directed.

12

-

-

... More
Supply only new piston with pin & ring set for compressor of Make:-Blue Star, model No LCWR-1 - 075, 75 TR Capacity complete all as specified and directed.

6

-

-

... More
Supply only oil pump for compressor of. Make:-Blue Star, model No LCWR-1 - 075, 75 TR Capacity complete all as specified and directed.

1

-

-

... More
Supply only connecting rod for compressor of 75 TR Capacity complete all as specified and directed.

3

-

-

... More
Supply only new cylinder sleeves for compressor 75 TR Capacity complete all as specified and directed.

5

-

-

... More
Supply only new helical spring discharge / suction for compressor of 75 TR Capacity complete all as specified and directed.

7

-

-

... More
Supply only main bearing front and rear for compressor of 75 TR Capacity complete all as specified and directed.

3

-

-

... More
Supply only water temperature censor for compressor of 75 TR Capacity complete all as specified and directed.

4

-

-

... More
M&L in replacement Y-type strainer flanged type as per existing 50/80mm dia, complete all as specified and directed . Make : Zoloto/Leader /Zenith / Crescent

2

-

-

... More
M&L for dismantling existing water softener and replacement with raw water in to online electrostatic non chemical water treatment system electrically operated control panel to be fixed on sub header/tapping suitable for , the outer casing shall be of 304 grade stainless steel with both ends flanged and capable of preventing scale formation of AC Plants flanged ends including necessary mechanical jointing operation like welding work, nut, bolts and rubber packing with starter panel electronically operated of existing length, complete all as specified and directed . Make: scale off model no 3021 mfg by Weldon Engineers

2

-

-

... More
M&L for cleaning of all condensor tubes of central AC plant by disconnecting the condensors -02 Nos from the system, cleaning by descaling pump using descaling solution of Make:-MAIC / HIBIRD or Hydrochloric acid 20%, cleaning the system through cooling tower by using descaling solution, cleaning condensor tubes by nylon brushes & mild steel rods of suitable size, renewal of suction water filter for 2x75 TR capacity plant at SCE. complete all as specified and directed . (Note:- T&P such as pumps, tube etc & descaling solution etc shall be arranged by the contractor at his own cost.)

2

-

-

... More
M&L for cleaning of all condensor tubes of central AC plant by disconnecting the condensors - 03 Nos from the system, cleaning by descaling pump using descaling solution of Make:-MAIC / HIBIRD or Hydrochloric acid 20%, cleaning the system through cooling tower by using descaling solution, cleaning condensor tubes by nylon brushes & mild steel rods of suitable size, renewal of suction water filter for 3x37.5 TR capacity plant at MH, complete all as specified and directed . Note:- T&P such as pumps, tube etc & descaling solution etc shall be arranged by the contractor at his own cost.

2

-

-

... More
S&F in replacement of scroll compressor unit of Make: Danfoss at OT MH AC plant and including compressor oil of 9.5 TR capacity by cutting of suction and discharge lines, unscrewing the foundation nuts & bolts etc, supply and fixing of new scroll compressor unit of suitable make as existing by connecting suction and discharge lines with filling of refrigerant gas including welding/brazing work and tightening foundation nuts & bolts etc all as specified and directed. Note:- Refrigerant gas shall be measured and paid separately as supply only under respective item of this sch.

4

-

-

... More
Supply and filling Non Freezing polyolester lubricant oil(POE-160PZ) to top up the scroll compressor at OT MH AC Plant . Make :Denfoss/TOTALINE/MANEUROP) complete all as specified and directed.

50

-

-

... More
S&F in replacement of water flow switch as per existing model complete all as specified and directed.

4

-

-

... More
S&F in replacement of Thermostatic expansion valves as per existing model complete all as specified and directed.

4

-

-

... More
S&F in replacement of Y strainer of of cooling tower as per existing sample complete all as specified and directed.

1

-

-

... More
S&F in replacement of strainer filter for hot and cold pipe lines as per existing model complete all as specified and directed..

2

-

-

... More
S&F in replacement of dry type cleanable and easily maintainable AHUS air filter suported by GI wire as per existing sample of air handling unit complete all as specified and directed.

8

-

-

... More
S&F in replacement of ML-3 power contactor 3 phase Make L&T / Legrand or equivalent complete all as specified and directed.

4

-

-

... More
S&F in replacement of water pressure gauge at suction and discharge side of pump in 4 inch round shape (0-100) LB/IN C2 with U or S shaped steel tube of 12mm dia approx length of 300 with pressure regulator valve brass connected with union reducer to the water supply line by making hole and welding and testing complete all as specified and directed.

2

-

-

... More
S&F temperature meter 6 inch long for condenser suction and discharge as per existing model complete all as specified and directed.

4

-

-

... More
Dismantling of burnt fan motor of walk cooler out door unit double shaft and supply & fixing new fan motor (Suitable for Carrier/ Voltas/ Blue star / LG / Samsung Make AC) as per sample complete all as specified and directed.

3

-

-

... More
Servicing of IDU (Indoor unit) of ceiling mounted casset type split Air conditioner of 3 TR/4 TR capacity comprising of Blower, blower motor ,water lifting motor, oiling & greasing of moving parts complete all as specified and directed.

16

-

-

... More
Supply and filling in compressor oil for topping up make- servo friz 68/Freezol 68 or as recommonded by the dealer suitable for existing compressor complete all as specified and directed.

200

-

-

... More
S&F in replacement brass suction valve size 3/8" complete all as specified and directed.

25

-

-

... More
S&F in replacement Discharge valve size 1/2" complete all as specified and directed .

30

-

-

... More
S&F in replacement ML-1 contractor 240 volt, 25 Amp for split type AC complete all as specified and directed .

4

-

-

... More
S&F in replacement copper capillary of size 0.55 mm complete all as specified and directed

4

-

-

... More
M&L for Nitrogen pressure testing Flushing out the system by Nitrogen ,vacumrnation and charging of refrigerant gas R-32/R410A into walking cooler unit complete all as specified and directed. (The refrigerant gas R-32/R410A will be provided by Contractor)

3

-

-

... More
Servicing and overhauling of walk in cooler of any make Blue star Model - PC 1950 with strainer steel product and with two condensing unit installed at any location in cantonment including cleaning and painting internally and externally with two coats of synthetic enamel paint ; reparing/ renewal/replacement of defective parts and component all as specified and directed. Parts renewed shall be measured and paid separately under appropriate items complete all as specified and directed.

4

-

-

... More
S&F in replacement of expanssion device of walk in cooler complete all as specified and directed .

2

-

-

... More
S&F in replacement of PLC unit of walk in cooler 2 ton capacity complete all as specified and directed. Make: Siemens/ Schnieder

2

-

-

... More
S&F in replacement of PCB circuit of walk in cooler complete all as specified and directed .

2

-

-

... More
Removing burnt/defective sealed compressor unit of any make from any type of walk in cooler 1.5/2 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply amd fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc complete all as specified and directed.

2

-

-

... More
M&L for repair to PCB circuit in walk in cooler 1.5/2 ton capacity complete all as specified & directed.

4

-

-

... More
Taking out the existing unserviceable low pressure cut - out switch and supply & fixing new low pressure cut-out switch type. MP - 1 all as specified and directed. (Make:- INDFOSS / RANUTROL)

4

-

-

... More
Taking out the existing unserviceable low pressure cut - out switch and supply & fixing new low pressure cut-out switch type. MP - 5 all as specified and directed. (Make:- INDFOSS / RANUTROL)

4

-

-

... More
Taking out the existing defective pilot control solenoid valve and supply & fixing new pilot control solenoid valve all as specified and directed. (Make: SPORLAIN or as approved by G.E.)

4

-

-

... More
Taking out the existing defective loader / unloader solenoid valve ( Capacity Control solenoid valve) and supply & fixing new loader / unloader solenoid valve all as specified and directed (Make: Nikko / Rotex or equivalent as approved by GE)

6

-

-

... More
S&F in repair single phase preventor to prevent against single phasing, reverse phasing with wiring & testing complete all as specified and directed. (Make:- Minilec / Electromed / L&T/ABB/Seimens)

9

-

-

... More
Supply and topup refrigerant gas Non CFC compatible to R-32 in returnable sealed cylinder all as specified and directed. (Make:- Floran / Mafron)

90

-

-

... More
Supply and topup refrigerant gas Non CFC compatible to R-407 in returnable sealed cylinder all as specified and directed. (Make:- Floran / Mafron/R value)

200

-

-

... More
Supply and topup refrigerant gas Non CFC compatible to R-410 in returnable sealed cylinder all as specified and directed. (Make:- Floran / Mafron/R value)

250

-

-

... More
Taking out the existing silica gel flange type filter drier 1/2" x 1/2" dia flare and supply & fixing new filter drier of the same type & size (Make:- Universal / Unistar) including repairs to flare etc at all as specified and directed by EIC

4

-

-

... More
Supply and replacement of return air grill aluminium with powder coated white collers of size 300 mm x 900 mm complete all as specified and directed.

10

-

-

... More
Supply and replacement of air grill MS air control damper of size 300 mm x 900 mm complete all as specified and directed.

8

-

-

... More
M&L for servicing of air curtain by removing the existing choked fins/filters complete all as specified and directed .

6

-

-

... More
Removing burnt/defective sealed compressor unit of any make from any type of air conditioner split/cassele type 3 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply amd fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc complete all as specified and directed.

2

-

-

... More
S&F in replacement of blower Motor 0.2/0.25 HP for walking cooler/Air curtain complete all as directed and specified (Make - GE/Crompton/Polar)

2

-

-

... More
S&F in replacement of blower Motor 0.5 HP for walking cooler complete all as directed and specified. (Make - GE/Crompton/Polar)

3

-

-

... More
S&F in replacement of PCB circuit as per existing model of walking cooler complete all as specified & directed. (Make – Blue Star/Voltas/Carrier)

3

-

-

... More
M&L for removing the existing choked fins of 2x75/3x37.5 TR cap cooling tower and supply and fixing new fins to cooling tower for AC Plant complete all as specified and directed .

800

-

-

... More
S&F capacitors 6 Mfd capacities 2 pin for ACs/ Walk- in- cooler etc , complete all as specified and directed . Make:- Asian/Tipcon/Usha/Epcos/Havells

11

-

-

... More
S&F capacitors 10 Mfd capacities 3 pin for ACs/ Walk- in- cooler etc , complete all as specified and directed . Make:- Asian/Tipcon/Usha/Epcos/Havells

6

-

-

... More
S&F capacitors 30/40 Mfd capacities 4 pin for ACs/ Walk- in- cooler etc , complete all as specified and directed . Make:- Asian/Tipcon/Usha/Epcos/Havells

9

-

-

... More
S&F capacitors 50/60 Mfd capacities 4 /6 pin for ACs/ Walk- in- cooler etc , complete all as specified and directed . Make:- Asian/Tipcon/Usha/Epcos/Havells

7

-

-

... More
S&F capacitors 80/100 Mfd capacities 4 pin for ACs/ Walk- in- cooler etc , complete all as specified and directed . Make:- Asian/Tipcon/Usha/Epcos/Havells

9

-

-

... More
S&F in replacement of V Belt, 'B' section (17x11mm) of B-29 size, complete all as directed. Make : Fenner / Dunlop.

5

-

-

... More
All as per srl item No. 98.00 here-in-above but B-36 size complete all as specified and directed.

5

-

-

... More
All as per srl item No. 98.00 here-in-above but B-41 size complete all as specified and directed.

4

-

-

... More
S&F of Step Controller with digital display, More than 5 steps, for Hot Water Generator wall as per sample, complete all as specified and directed. Make - Rapid cool / Honeywell.

1

-

-

... More
Quarterly Periodical, preventive & comprehensive maintenance by dis-assembly, repairing, overhauling, servicing & testing of complete inner tank, Elements, inlet and out let pipe, valves of Hot water generator installed at AC plant including descaling, replacement of gaskets complete incl painting with two coat of heat resistant paint of smoke grey colour complete all as specified and directed.

2

-

-

... More
S&F in replacement, of three phase heating element capacity 20KW( set of 06 Nos) capacity, ISI marked of existing shape and size suitable for hot water generator and making electric connections and taking down old unserviceable heating elements, complete all as specified and directed. Make : Daspass / Theata

1

-

-

... More
M&L for indoor type LT panel board and replacement of unserviceable switch/control gears and meters, selector switches, indicator lamps etc including rewiring and extension of incoming and outgoing cables by opening of loops and provisioning of cable lugs /thimbles as required and replacement of rusted sheet metal with existing size MS sheets by necessary arc/gas welding(Approx sheet 1 Sqmtrs ) including two coats of synthetic enamel spray painting over a coat of red oxide primer both inside and outside surfaces of Panel Board including rewriting of identification for controls, complete all as specified and directed . Note: MCCB, contactors, relay, single phase preventer, timer, Change over, Indicator lamp, Selector switch, Ammeter, Voltmeter etc given below will be measured and paid in respective items.

5

-

-

... More
Supply and fixing Single phase preventer with Auto switch . Type- Cat No 2.BSP-2, complete all as specified and directed . Make- Bentex / Minilec

8

-

-

... More
Supply and fixing MCCB (AC 415 V) with adjustable thermal & adjustable magnetic setting Four pole 400 Amp 36 KA, complete all as specified and directed . Make : GE or equivalent C &S /Legrand

2

-

-

... More
Supply and fixing MCCB (AC 415 V) with adjustable thermal & adjustable magnetic setting Four pole 320 Amp 36 KA, complete all as specified and directed . Make : GE or equivalent C &S /Legrand

2

-

-

... More
Supply and fixing MCCB of capacity , 250 Amps ,04 pole ,415 V, 36 KA Breaking capacity with fixed thermal magnetic release, complete all as specified and directed . Make- GE or equivalent C &S /Legrand

1

-

-

... More
Supply and fixing MCCB 200 A, 4 Pole, 415 V, 36 KA Breaking capacity, with fixed thermal magnetic release, complete all as specified and directed . Make- GE or equivalent C &S /Legrand

2

-

-

... More
Supply and fixing MCCB 100 A, 3 Pole, 415 V, 35 KA Breaking capacity, with fixed thermal magnetic release, complete all as specified and directed . Make- GE or equivalent C &S /Legrand

2

-

-

... More
Supply and fixing Moulded Case Circuit Breaker (MCCB) (AC 415 V) with adjustable thermal & adjustable magnetic setting Three pole 63 Amp 25 KA , complete all as specified and directed Make : GE or equivalent C &S /Legrand

2

-

-

... More
Supply and fixing Motor protection circuit breaker thermal overload relays suitable for ML contactors relay range 10-16A, complete all as specified and directed . Make-Havells/L&T/Legrand

2

-

-

... More
Supply and fixing Power contactor 3 pole Type MNX 18 AC 3 rating 18 A with auxiliary contact 2 NO + 2 NC , complete all as specified and directed . Make- L&T/Legrand

2

-

-

... More
Supply and fixing Power contactor 3 pole Type MNX 70 AC 3 rating 70 A with auxiliary contact 2 NO + 2 NC , complete all as specified and directed . Make- L&T cat part No. ST19002 or equivalent in Legrand

2

-

-

... More
Supply and fixing Power contactor 3 pole Type 3 ML AC 3 rating 40 A with auxiliary contact 2NO + 2NC, complete all as specified and directed . Make- L&T cat part No - SS90721 or equivalent in Legrand

2

-

-

... More
Supply and fixing Power contactor 3 pole Type MNX 25 A AC 3 rating 25 A with auxiliary contact 2NO + 2NC, complete all as specified and directed . Make- L&T cat part No - SS90921 or equivalent in Legrand

4

-

-

... More
Supply and fixing Power contactor 3 pole Type 1.5 ML AC 3 rating 25 A with auxiliary contact 2 NO + 2 NC, complete all as specified and directed . Cat No - SS91851 Make- L&T/Legrand

2

-

-

... More
M&L for replacement of Cable 3 core flexible heavy duty copper cable of size 4 sqmm of AC , Water Cooler, stabilizer etc. complete all as specified and directed . (Make-Plaza/Finolex /Polycab)

110

-

-

... More
M&L for replacement of Cable 3 core flexible heavy duty copper cable of size 6 sqmm of AC , Water Cooler, stabilizer etc. complete all as specified and directed . (Make-Plaza/Finolex /Polycab)

100

-

-

... More
M&L for shifting/installing Split type Air conditioner of any 3/4 Ton capacity complete with piping and copper tubing arrangements including fixing the suction unit on wall and making good as existing as well as making electric connections complete all as specified and directed . Note :- Copper tubing ,drain pipe and other insulation material measured under relevant item).

5

-

-

... More
S&F insulation of copper tubing wherever required complete all as specified & directed Note : Insulation of cold&return air copper tuning measured as one running meter.

60

-

-

... More
S&F Copper pipe 20 mm dia with insulation for split AC complete all as specified & directed.

90

-

-

... More
S&F Copper pipe 12 mm dia with insulation for split AC complete all as specified & directed .

70

-

-

... More
M&L for scraping down, cleaning and preparation of old painted surface, applying one coat of synthetic enamelled paint to AC installation Central type AC Plant 2x75 TR all as per existing colour code including sign writing as directed. (AC installation comprising of compressor, motor condenser, pipe line, panel board, valves, AHU cooling tower, Chillar pipe and display board) marking direction of flow and writing SM Nos and MES Nos of size not less than one inch complete all as specified and directed.

1

-

-

... More
M&L for scraping down, cleaning and preparation of old painted surface, applying one coat of synthetic enamelled paint to AC installation Central type AC Plant 3x37.5 TR all as per existing colour code including sign writing as directed. (AC installation comprising of compressor, motor condenser, pipe line, panel board, valves, AHU cooling tower, Chillar pipe and display board) marking direction of flow and writing SM Nos and MES Nos of size not less than one inch complete all as specified and directed.

1

-

-

... More
Supply &Fixing Rotational moulded (3 layered as per IS 12701) polythylene water storage tank cylindrical vertical with closed top hoisted capacity upto 5000 ltrs ISI marked with valid CMLNo and fixed in position complete all as specified and directed .

1

-

-

... More
LIFT

-

-

-

... More
Supply & installation of sheeve (C/I/casting traction sheeve 4 grooves pully Code OD 560x4x13mm in passenger lifts) as per site requirement welding/ brazing etc complete and testing on load complete all as per directed by Engr-in-Charge.

2

-

-

... More
Supply and replacement of LOP of door with digital desplay complete all as specified and directed . (Ground floorF /Top floor)

2

-

-

... More
Supply and replacement of shoe liner as per existing size of lift complete all as specified and directed .

2

-

-

... More
Supply and replacement of PCB unit for MCU, CCU & CTU complete all as specified and directed .

2

-

-

... More
Supply and fixing in replacement of maintenance free battery with initially charged Capacity 12V 18AH complete all as specified and directed .

4

-

-

... More
Supply and replace Guide Shoe liner CWT complete all as specified and directed .

2

-

-

... More
Supply and replace Main Contactors complete all as specified and directed .

3

-

-

... More
Supply and replace Break liner with revits and gasket complete all as specified and directed .

2

-

-

... More
Supply and replace Guide Shoe liner Car complete all as specified and directed .

1

-

-

... More
Supply and replace Door lock rubber bush complete all as specified and directed .

1

-

-

... More
Supply and replace Limit switch Assembly complete all as specified and directed .

2

-

-

... More
Supply and replace DC Magnetic coil for break with spring complete all as specified and directed .

1

-

-

... More
Supply and replace Shaft safety switches full set complete all as specified and directed .

2

-

-

... More
Supply and replace Hall / Car push button unit complete all as specified and directed .

8

-

-

... More
Supply and replace Pick up roller unit complete all as specified and directed .

2

-

-

... More
Supply and laying inreplacement of of 2.5 mm thick insulated synthetic mat of confirming to IS 15652 : 2006 and meeting the requirements of IS 5216 (Part 1.2 & 3) IS 8437, IFC-479 Pub-1, alongwith suitable adhesive/chemibound, PU resin, waterproofing compound and sealing material as per in service recommendation of IS : 15652 class – B suitable for working voltage up to 11 KV with trolley movement complete all as specified and as directed Make : SAFEVOLT/INSULICA

20

-

-

... More
Supply and laying LT XLPE insulated under ground 1100 volt grade with stranded aluminium conductor of following sizes in trenches /passing through pipes/ on poles etc complele all as specified and directed.

-

-

-

... More
16 sqmm 4 core.

115

-

-

... More
25 sqmm 4 core.

120

-

-

... More
35 sqmm 3.5 core.

120

-

-

... More
95 sqmm 3.5 core.

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.