Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil Works Others
Eprocure
Opening Date9 Jul 2021
Closing Date7 Aug 2021
Tender Amount₹ 37,98,271 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 83,700Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_MES_458237_1Bid Award Id
ViewTender No
GE(I)/KAN/T-27 OF 2021-22Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for glazed ceramic coloured tiles 300x450x6 to 7 mm thick on vertical surfaces such as skiting/dado set and jointed in neat cement slurry and pointed in colour cement to match the shade tile over and inclduing 10mm thick rendering in CM (1:4) complete all as specified and directed.Note: Colour, design and pattern shall be approved by GE.
475
-
-
Taking down cement plaster/terrazzo on brick or stone wall etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
175
-
-
M&L for 15 mm thick rendering in cement mortar 1:6 on fair faces of concrete or brick, finished even and fair without using extra cement complete all as specified and directed.
50
-
-
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of concrete or brick surface mixed with waterproofing compound as per manufacturer instructions surface finished even and fair without using extra cement complete all as specified and directed.
100
-
-
M&L for 10 mm thick cement plaster on ceiling in CM 1:3 finished even and smoot without using extra cement complete all as specified and directed.
25
-
-
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
25
-
-
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
25
-
-
M&L for preparation of old decorated plastered surfaces of ceiling and applying one coats of white wash complete all as specified and directed.
1980
-
-
M&L for preparation of old decorated plastered surfaces of walls and applying two coats of white wash complete all as specified and directed.
25
-
-
Taking down existing sunken portion treatment by demolition of old concrete and carry out the sunken treatment as in following steps given below : .
120
-
-
(a) S&F drainage spout pipe GI 40 mm dia bore light grade upto outside of outer wall (Approx 450 mm to 600 mm long)
-
-
-
(b) M&L PCC 1:1.5:3 type B0 (using 12.5mm graded stone agg), 50 mm thick laid in slope towards drainage out spout pipe mixed with waterproofing chemical as per manufacturer instructions of MAKE :FOSROC/SICA/ Pidilite/STP. Khurra 150mmx150mm (min) at appropriate location for free flow (of leaked water if any) towards drainage spouts shall be provided integrally while laying PCC.Fixing of spout shall be done with same PCC as in this item.
-
-
-
(c) M&L18 mm thick cement platster in CM 1:3 on vertical faces mixed with water proofing chemical of MAKE :301 Pidicrete URP of Dr Fixit or other techno commercially Equivalent make of SIKA/ Pidilite/FOSROC/STP
-
-
-
(d) Item no 58.03 shall be executed while concrete is green as per item no 19.02 above and proper curing and ponding test shall be done before laying drainage/water supply pipes upto the entire satisfaction of Engineer in charge.
-
-
-
(e) Applying two coats of SIKA TOP seal 107 of SIKA or other techno commercially Equivalent make of FOSROC /Pidilite/Dr Fixit/STP on vertical as well as horizontal surface.
-
-
-
(f) Drainage and water supply pipe if required & test for leakage/sanitary pipes and shall be laid to slope and a clear gap underneath the pipes shall be made available by providing suitable cement concrete blocks.
-
-
-
(g) M&L PCC1:5:10 type E-2 using 10-40mm down graded stone aggregate as reqd depth at site over and including 150mm thick 20mm single sized stone agg to provide a filter media .
-
-
-
(h) M&L PCC 25 mm thick 1:2:4 type B-0 using 12.5 mm grade stone aggregate as level course.
-
-
-
(j) M&L for 7 to 8 mm thick joint free non skid ceramic coloured printed tiles (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc; laid jointing in neat cement slurry and pointed filled with epoxy chemical make: SIKA/FOSROC/PIDILITE/ Dr Fixit/STP.mixed with pigment to match with shade of tiles over and including 15 mm thick screed bed in CM ( 1:6 ).
-
-
-
Note for item NO 58 (i) Waterproofing Treatment shall be undertaken alongwith laying of drainage pipes/Sanitary pipes/ Drainage Spout etc (ii) The work shall be carried out as per the direction of Engineer in Charge. (iii) The sunken treatment work shall only be carried out after written approval of Engineer in charge for Leakage/seepage of water/sanitary pipes. (iv) Cost of drainage spout shall deemed to be included in the item however sanitary pipe, water pipe line if required shall be paid separately under respective item.
(v) Laying of Chemical required for varios applications shall be as per manufacturer instructions. (vi) Plan area shall only be measured and paid. (vii) The contractor shall give a guarantee of 10 years from the date of completion of work for sunken treatment. The amount Rs. 25.00 (Rupees Twenty five Only) per Sqm and min of Rs 2500/- for sunken treatment shall be withheld from contractor’s final bill till the expiry of guarantee period. The contractor at his own option may furnish fix deposit receipt pledged in favour of GE (I) Kanpur.
-
-
-
Taking up or down 15 mm dia steel tubing and connection including removal complete and all as specified and directed
50
-
-
Taking up or down 20 mm dia steel tubing and connection including removal complete and all as specified and directed
225
-
-
Taking up or down 25 mm dia steel tubing and connection including removal complete and all as specified and directed
237
-
-
S&F 15 mm bore steel tubes medium grade galvanized with all fitting and fixed complete to walls and ceiling or laid in floor complete and all as specified and directed.
50
-
-
S&F 20 mm bore steel tubes medium grade galvanized with all fitting and fixed complete to walls and ceiling or laid in floor complete and all as specified and directed.
225
-
-
S&F 25 mm bore steel tubes medium grade galvanized with all fitting and fixed complete to walls and ceiling or laid in floor complete and all as specified and directed.
237
-
-
Refixing old steel tubing 15 mm dia of bore and connections in new or old position (Walls, ceiling, floors, etc.)
5
-
-
Refixing old steel tubing 20 mm dia of bore and connections in new or old position (Walls, ceiling, floors, etc.)
10
-
-
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps cills sunshades shelves lintels etc, and cuttign chases for concealed water tubing or conceasled conduit wiring etc and making good cutting exc 10cm but not exc 20cm girth.
275
-
-
S&F in repairs 15 mm bore CP brass bib taps fancy type long body screwed to GI pipe of 15 mm bore and fixed including SS flange complete all as specified and directed. Make : Hindware/L&K/Plumber/ Jaguar/Prayag as approved by GE.
78
-
-
S&F in repairs 15 mm bore CP brass angle cock fancy type screwed to GI pipe of 15 mm bore and fixed including SS flange complete all as specified and directed. Make : Hindware/L&K/Plumber/ Jaguar/Prayag as approved by GE.
42
-
-
S&F in repairs 15 mm bore CP brass stop valves fancy type screwed to GI pipe of 15 mm bore and fixed including SS flange complete all as specified and directed. Make : Hindware/L&K/Plumber/ Jaguar/Prayag as approved by GE.
12
-
-
S&F in repair PVC connection 450mm long heavy duty brass check nut bolts for fixing 15mm dia pipe complete all as specified and directed.
42
-
-
S&F 150 mm dia brass CP shower rose with swivel joint fixing to steel pipe or union complete all as specified.Make : Hindware / L&K / Plumber / Jaquar/Prayag as approved by GE(I).
12
-
-
S&F in repair 10 ltrs capacity low level PVC flushing cistern, valveless, symphonic type, white,with inlet,ball float and handle including brackets incl PVC connection 300mm with flanges at both end screwed down to 15 mm bore GI pipe and 32mm bore PVC flush pipe of required length complete and all as specified and directed.Make : Hindware/Cera/Parryware/Prayag as approved by GE.
18
-
-
S&F In repair vitreous china wash down water closet semi-pedestal pattern (anglo-indian Type) white with plastic seat cover (excluding fixing of bolt of flushing cistern and flush pipe) including all fitting complete all as specified and directed. Make : Hindware/ Cera/ Parryware/ Prayag as approved by GE.
6
-
-
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440mm with integral foot rest including all fitting connecting with trap set and including concrete bedding , complete all as specified in SSR Part I and as directed.Make : Hindware/Cera/Parryware as approved by GE.
12
-
-
S&F in repairs 15 mm bore CP brass angle cock two way fancy type with capstan head screwed to GI pipe of 15 mm bore and fixed including SS flange complete all as specified and directed. Make : Hindware/L&K/Plumber/ Jaguar/Prayag as approved by GE.
12
-
-
S&F in repairs brass, chromium plated soap dish complete all as specified and directed.
24
-
-
S&F in repairs stainless steel jet for EWC with flexible chord of approved quality complete all as specified and directed.
6
-
-
S&F in repairs brass, chromium plated toilet paper holder complete all as specified and directed.
6
-
-
S&F in repair hand shower (health faucet) with 15 mm dia 1 mtr long flexible tube and wall hook chromium plated complete all as specified and directed. Make: L&K/ Hindware/ Prayag/ Jaquar/Plumber
6
-
-
S&F in repairs cast iron floor trap of 75 mm dia, chromium plated grating including jointing to waste pipe with lead joints and fixed in cement concrete 1:2:4, type B-0 (using 12.50 mm graded stone aggregate) complete all as specified and directed.
42
-
-
Supplied and fixed CI soil waste & vent centrifugally cast spun pipe in any length with or without ears, with cement joints 100 mm bore laid in floor/trenches all as specified & directed.
15
-
-
Supplied and fixed CI soil waste & vent centrifugally cast spun pipe in any length with or without ears, with cement joints 100 mm bore laid on walls with MS flat iron clamps with 50x6mm and 16mm dia round bar stay of required shape and size inclduing drilling holes and embedded in CM 1:3 surface finished all as specified & directed.
30
-
-
Supplied and fixed CI soil waste & vent centrifugally cast spun pipe in any length with or without ears, with cement joints 75 mm bore laid in floor/trenches all as specified & directed.
95
-
-
Supplied and fixed CI soil waste & vent centrifugally cast spun pipe in any length with or without ears, with cement joints 75 mm bore laid on walls with MS flat iron clamps with 50x6mm and 16mm dia round bar stay of required shape and size inclduing drilling holes and embedded in CM 1:3 surface finished all as specified & directed.
40
-
-
Supplied and fixed CI spun type bend 100 mm bore ( any radius ) with oval access door diminishing pieces or tapers (large bore measured) all as specified and direced.
18
-
-
Supplied and fixed CI spun type bend 75 mm bore ( any radius ) Tee single or double with oval access door diminishing pieces or tapers (large bore measured) all as specified and direced.
36
-
-
S&F in repair PTMT half or full threaded 32 mm bore waste coupling complete all as specified and directed.
18
-
-
S & F in repair looking mirror of size 600 mm x 450 X 4 mm thick glass with 5 mm thick plain PVC sheet fixed at back side and 5mm thick prelaminated PVC sheet frame around the mirror including hanging arrangement complete all as specified and directed .Make : Rajshree Plastiwood Make of glass :-(a) Saint Gobain (b) Modi Guard (c) Hindustan Pilkington Glass works as approved by GE.
12
-
-
M&L for 25 mm thick PCC Type B0 1:2:4 (12.5 mm graded agg) as in leveling /sub base of flooring complete all as specified and directed.
60
-
-
M&L for 7 to 8 mm thick non skid ceramic coloured tiles (Joint free) (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc; laid jointing in neat cement slurry and pointed in white cement mixed with pigment to match with shade of tiles over and including 15 mm thick screed bed in CM ( 1:4 ) complete all as specified and directed. Note: Colour, design and pattern shall be approved by GE.
60
-
-
Material and Labour for 20mm thick granite slab on floor/ vertical surface of any colour ( table rubbed and polished) including pointing with white cement (1:2) using marble dust, of superior quality set and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing with edges to be bullnosed, and including 20 mm thick screed bed in CM ( 1:4 ) complete all as specified and as directed
10
-
-
Taking down chowkhats with shutters (without taking off shutters from the frame) area not exc 1.5 sqm each complete all as directed by Engineer-in-Charge.
86
-
-
Taking down chowkhat or frames with shutter (without taking of shutters from the frame) exc 1.5 sqm n exc 4 sqm each complete all as specified and as directed
12
-
-
Taking down shutter of any description exc 1 sqm and n. exc. 2 sqm each complete all as directed by Engineer-in-Charge.
12
-
-
M&L for welding in repairs n exc 6mm thickness of metal to be welded
5
-
-
S&F in repair HDPE triple layer rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 2000 litres capacity hoisted and fixed in position all as specified in SSR Pt-I including for hoisting into position either inside or outside of building, connecting up pipes, securing access cover etc including GI nipple of suitable size including Supplied and fixed 20mm dia pvc float valve assembly complete all as specified and directed. Make: Sintex/ Dhara/Tuff/JS Polyplast as approved by GE(I).
3
-
-
S&F in repairs 25 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe and fixed (min wt-210 gram) complete all as specified and directed. Make :Symet prayag
2
-
-
Removing of demolished meterial to a distance of 200m or under, beyond the lead included in the rates, including loading, unloading complete all as specified and directed
40
-
-
M & L factory solid panel PVC door shutter 30mm thick (style) consisting of frame made ourt of M.S. tubes for top & bottam rails. M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with soilvent cement for stiles and plain colour PVCsheets for rail, lock rail & bottam eail on either side & asinsert for top rail & bottam rail, penelling of plain colour PVC sheet to be fitted in the M.S. frame welded /sealed/ with copper screws to the stules & rails with suitable PVC sheet beading and jointed together with solvent cement suppling & fixing in the frame at site all as specified and directed.
60
-
-
M & L Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling & fixing with copper screws in opening as per specification & drawing, including making good the damaged wall with plaster or concreteall as per specified and directed.
180
-
-
S&F of 100 mm long PVC butt hinges, complete all as specified and directed. Make – Prayag or equivalent as approved by GE.
114
-
-
S&F of 150 mm long PVC handles, complete all as specified and directed. Make – Prayag or equivalent as approved by GE.
38
-
-
S&F of 150 mm long PVC barrel tower bolt complete all as specified and directed. Make:– Prayag or equivalent as approved by GE.
38
-
-
S & F of factory made 35 mm thick second class hard wood plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003(Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
24
-
-
S&F factory made 35mm thick glazed and skelton shutters (Three panel) of IInd class HW, , open rebated and prepared to receive glass, gauze, etc. ( without sash bars) edge of framming plain chamfered, or rounded, fitted with cut and mitred beads for securing glass etc, size of member of shutters as specified in SSR part I , section 8, clause 8.20(a) , supplied and fitted to chowkhats.
18
-
-
Supply and fix 100 mm butt hinges medium weight cold rolled mild steel ISI marked and fixed with mild steel wood screws complete all as specified and directed.
32
-
-
S&F 300 mm long aluminium anodised Sliding door bolt with haps, staple (bolt type)and fixing clips of sheet, cast or extruted section and fixing bolts and sliding bolts of extruted sections or cast-aluminium alloy all as specified and directed.
6
-
-
M&L Painting to wood and wood based surface of any description over 10cm width or girth including two coat of synthetic enamel paint over a coat of pink primer including preparation of newly or previously untreated surface complete all as specified and directed.
86.4
-
-
M&L Painting to wood and wood based surface of any description over 10cm width or girth including one coat of synthetic enamel paint on old surface complete all as specified and directed.
230
-
-
S&F of 150 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
48
-
-
S&F of 150 mm long barrel tower bolt aluminium anodised of extruded section and fixed complete all as specified and directed.
48
-
-
M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
35
-
-
M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint on old surface complete all as specified and directed.
650
-
-
S&F factory made steel tubular window with side hung shutters including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded etc including taking down old window complete all as specifed as per HQCELZ Lucknow Drg no LZ/C-TD/130 sheet 1/4 to 4/4 and as directed by Engineer in Charge.
12
-
-
S&F factory made steel tubular window with side hung shutters including box type hindes with steeel handleand steel peg stay complete without glazing bars dovetailed or welded etc including taking down old window complete all as specified as per HQCELZ Lucknow Drg no LZ/C-TD/130 sheet 1/4 to 4/4 and as directed by Engineer in Charge.
12
-
-
S&F factory made steel tubular Steel ventilators with top hung shutter including hinges, steel peg stay complete as as per HQ CELZ Lucknow Drg No LZ/C-TD/130 sheet 1/4 to 4/4 specified and directed.
10.8
-
-
S&F Framed work such as grills, grating etc. with ends of bars shouldered and / or riveted or forget into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
120
-
-
S&F 3mm thick figured glass pin haded type and glazing with oil putty in squares n. exc 0.5sqm in each pane complete all as specified and directed.
10
-
-
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and 1.40 mm averaage width of operature fixed with tinned tacks or galvanished wire staple complete all as speficied & directed.
10
-
-
S&F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and 1.40 mm averaage width of operature fixed with tinned tacks or galvanished wire staple complete all as speficied & directed.
5
-
-
Supply & Fixing 3mm thick Sheet glass ordinary quality and glazing with oil putty in squares n. exc 0.5sqm in each pane complete all as specified and directed.
5
-
-
S&F in repair Vitreous China urinals half stall type complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinals to plugs with and including 60mm long brass screws pointing around urinal back in cement fixing flush pipe grating and union for discharge pipe complete all as specified and directed.
12
-
-
Dismantling of brick work built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facing etc.complete all as specified and directed.
0.73
-
-
M&L Brick work with old size sub class B brick straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1:6 comlete all as specified and as directed.
0.5
-
-
M&L Brick work with old size sub class B brick straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 with complete all as specified and as directed.
2
-
-
S&F framed work of angle or tees with web and flanges cut to shape, drilled and countersunk for screw, incl bending & welding angles as necessary conforming to Fe 290 Gde for cage to PVC water tank rested on RCC roof slab/other similar work complete all as specified.
575
-
-
S & F in repair vitreous china wash hand basin, white flat/angle back size 550 x 400 mm complete incl necessary cutting holes and pinning in ends of brackets and one CP pillar tap 15 mm dia bore of make L&K/Jaquar/Prayag/Plumber as approved by GE and 32 mm bore PVC waste pipe and 32 mm brass CP waste coupling complete all as specified in repairs. Make : Hindware/Cera/Parryware as approved by GE.
2
-
-
M&L 40 mm thick PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in floor finishing surface even and smooth wihtout using extra cement including mastic filling in joints complete all as specified and as directed
15
-
-
M&L for preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper over a coat of primer including 1mm thick birla wall care putty complete all as specified and directed.
50
-
-
M&L for two coat of oil bound distemper over a coat of primer including 1mm thick birla wall care putty after complete removal of old treatment of wall complete all as specified and directed.
730
-
-
M&L Applying two coats of cement base paint over a coat of primer including preparation of newly plastered untreated surface of wall complete all as specified and directed.
75
-
-
M&L for Applying two coats of cement base paint after complete removal of old treatment of wall complete all as specified and directed.
1300
-
-
Demolition by using hand held electric drills, cutting machine, chisels etc (direct use of hammers on RCC roof for demolition is strcitly prohibited) of roof treatment including padding concrete of any description including mud in roof any thickness with and including roughening old concrete surfaces by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed by the Engineer-in-charge.
690
-
-
M&L water proofing treatment to roof slab with APP modified polymeric membrane thickness not less than 3 mm plain finish (weight of membrane not less than 3.90 Kg +/- 10% per Sqm) and weight of mineral filler shall be 160 gram +/- 15% per Sqm complete all as specified and directed by Engineer-in-Charge with following courses of descriptions below :-Make of membrane shall be SIKA/Super Thermolay APP (STP) / IWL as approved by GE
690
-
-
(a)The surface of roof, parapet and gutters and drains mouth etc over which waterproofing treatment is to be applied shall be thoroughly cleaned of all foreign matter, moss dust etc by wire-brushing and dusting. For cast iron/PVC drains outlets a grove shall be cut around to tuck in the treatment. Concrete angles-fillets provided at junctions between roofs and verticals faces of walls (parapet and other walls) around obstacles such as pipe, chimney stacks etc and other similar situation to ease up about corners..
-
-
-
(b) On the prepared surface one coat of Solvent based bituminous primer (Sika® WP shield Primer or other techno commercially Equivalent make of STP/IWL ) shall be applied @ 0.35 to 0.50 Kg/sqm till the surface is properly impregnated. The time delay of laying of membrane after application of primer shall be as per manufacturer instructions
-
-
-
(c) Laying of polymeric waterproofing membrane and bonded completely to the substrate & the overlaps are then sealed /fused by flame torch as per manufacturer instructions.
-
-
-
(d) The overlaps shall be of minimum 4 Inch (100 mm) side lap and 150mm at end ,sealed by the flame-torch.
-
-
-
(e) Special care is to be taken at singularities such as drains expansion-joints etc
-
-
-
Dismantling of terracing tiles/brick tiles single layer on roof,laid bedded and pointed in any mortar complete all as specified and as directed by the Engineer-in-charge.
69
-
-
M&L for brick tiles (Except tiles), joints grouted flush in CM 1:3 mixed with water proofing chemical as per manufacturer instruction of MAKE :FOSROC/SIKA/ Pidilite/STP as approved by GE over 15 mm thick screed bed in CM 1:4 , ponding test shall be done after laying of tiles complete all as specified and as directed by the Engineer-in-charge. (NOTE: (i) BRICK TILES RECEIVED FROM ITEM NO 91 SHALL BE REUSED) (ii) The work shall be be carried out in patches and the site shall be decided by the Engr-in-Charge on requirement basis. (iii) Liquid Water proofing chemical shall be measured and paid separately.
285
-
-
M&L for brick tiles 40mm thick with min flexural strength 1.5 N/Sqmm set, joints grouted flush in CM 1:3 mixed with with water proofing chemical as per manufactur instruction over 15 mm thick screed bed in CM 1:4 , ponding test shall be done after laying of tiles complete all as specified and as directed by the Engineer-in-charge.Note : Liquid Water proofing chemical shall be measured and paid separately.
405
-
-
M&L for plain cement concrete type B0 (1:2:4 ) using 12.5 mm graded stone aggregate as in coping, roof kerb incl hunching, benching etc surface finished smooth for dhesion of tar felt as specified and directed.
17.25
-
-
Conducting the field investigation (soil testing) (No of boring holes 02 nos , depth of bore holes required 6 RM Each hole) for the building area. The process of field investigation (soil testing)shall be as under: (A) (a) Boring of 150mm dia holes through overburden soil including shifting bore hole. (b) Carrying out standard penetration test of every 1.50 meter interval and at change of strata. (c) Collection of disturbed samples at every 1.50 meter interval including handling and transporting complete to the laboratory from 0.00 meter to 6.00 meter)
(d) Collection of undisturbed soil samples at 1.50 mtr interval & transporting including handling complete to the laboratory. From 0.00 mtr to 6.00 mtr)
(B) Conducting laboratory test on undisturbed and disturbed soil samples :- (a) Natural moisture contents as per IS : 2720 (Part III) - 1973. (b) Tri-axial compression test /direct shear test as per IS : 2720 (Part XIII)-1972 (c) Consolidation test as per IS: 2720 (Part XV) -1965 (d) Mechanical sieve analysis as per IS : 2720n (Part IV) - 1965 (e) Atterberg limit test as per IS: 2720(Part V) -1970 (f) Particle size analysis hydrometer test as per IS : 2720 (Part IV)-1965 (g) Dry and bulk density test as per IS: 2720 (Part XXVII)-1980 (h) Specific gravity test as per IS: 2720 (Part III) - 1980
(C) Submission of test report in quadruplicate including recommendation of depth, type and safe allowable bearing capacity for the foundation.
(D) The work shall be carried out from an agency having minimum five years experience in the respective field and should have conducted at least five soil explorations and report shall be vetted by Govt Engineering college/IIT/HBTI before submission to this office.
12
-
-
Conducting the field investigation (soil testing) (No of boring holes 06 nos , depth of bore holes required 10RM Each hole) for security wall pile/well foundation over Kachha Nallah. The process of field investigation (soil testing)shall be as under: (A) (a) Drilling of bore holes (BHS), taking and testing of soil samples to find soil parameters SPT 06 Nos Bore hole (Bore hole upto 10 mtr depth). (b) CBR test including proctor test soil samples. (c) Collection of disturbed samples at every 1.50 meter interval and at change of strata
(d) Collection of undisturbed soil samples at 2.50 mtr interval & transporting including handling complete to the laboratory. (B) Conducting laboratory test on undisturbed and disturbed soil samples :- (a) Natural moisture contents as per IS : 2720 (Part III) - 1973. (b) Tri-axial compression test /direct shear test as per IS : 2720 (Part XIII)-1972 (c) Consolidation test as per IS: 2720 (Part XV) -1965 (d) Mechanical sieve analysis as per IS : 2720n (Part IV) - 1965 (e) Atterberg limit test as per IS: 2720(Part V) -1970 (f) Particle size analysis hydrometer test as per IS : 2720 (Part IV)-1965 (g) Dry and bulk density test as per IS: 2720 (Part XXVII)-1980 (h) Specific gravity test as per IS: 2720 (Part III) - 1980
(C) Submission of test report in quadruplicate including recommendation of depth, type and safe allowable bearing capacity for the foundation.
(D) The work shall be carried out from an agency having minimum five years experience in the respective field and should have conducted at least five soil explorations and report shall be vetted by Govt Engineering college/IIT/HBTI before submission to this office.
1
-
-
EnM Schedule
-
-
-
Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan / plug / bell but including fittings such as switches, ceiling rose, pendents, regulator etc. and making good disturbed surface to match with the existing surface of roof / wall / floor by applying putty, plaster of paris etc. and applying finishing coat of existing treatment complete all as specified and directed.
513
-
-
M&L for point wiring with PVC (FRLS) insulated and unsheathed cable 1.5 Sqmm (Nominal area) multi-stranded copper conductor single core with proper colour coding including PVC conduit medium grade of 25 mm dia concealed in walls and surface on ceiling with and including pressed steel concealed terminal boxes of appropriate size and top cover 2.5-3.0 mm thick of plastic laminated sheet ISI marked of desired colour of make : Super Hylam, painting terminal boxes inside and outside with a coat red oxidé primer complete with all accessories with and including 1.5 Sqmm PVC insulated and unsheathed green colour multi-stranded copper conductor cable to common earth and connected to earth dolly complete all as specified and directed for the following points:-Note: Cutting chases in walls required for concealed conduit wiring shall be finished with cement mortar 1:4 and, surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor. Make of cable : Finolex/Polycab/ Havells/Plaza/Grandlay/ Gloster, Make of conduit : AKG/D-PLAST/FINOLEX/PLAZA as approved by GE
-
-
-
(a) One light/fan/bell/exhaust fan point controlled by one switch.
238
-
-
(b) One 3 Pin socket outlet 5 Amps on Independent board.
130
-
-
(c) One 3 Pin socket outlet 5 Amps on same board.
45
-
-
(d) One light/fan/bell/exhaust fan point controlled by one switch but upto ceiling height and on surface at ceiling.
60
-
-
(e) One light point controlled by two nos two way switch.
3
-
-
All as per item No. 99 here in before but for one power point, independent point with 2.5 Sqmm (Nominal area) PVC insulated and unsheathed copper conductor (FRLS) multi-stranded single core cable including green colour earth wire of size 1.50 Sqmm PVC insulated and unsheathed copper conductor (FRLS) multi stranded single core cable.
40
-
-
S & F of switch piano flush type 6 Amps single pole one way complete all as specified and directed.
40
-
-
S & F of switch piano flush type 6 Amps single pole two way complete all as specified and directed.
6
-
-
S & F of switch piano flush type 15 Amps 240 Volts single pole one way complete all as specified and directed.
40
-
-
S & F of socket outlet flush type, 5 pin 6 Amps, 240 Volts complete all as specified and directed.
175
-
-
S & F of socket outlet flush type, 6 pin, 5 and 15 amps multi purpose 2 in 1 flush type , 240 Volts complete all as specified and directed.
40
-
-
S & F electronic fan regulator step type,hum free suitable to control speed of fan from 0 to 100% and connecting electricity complete all as specified and directed.
60
-
-
S & F Electronic bell , AC 220 V all as specified and directed
12
-
-
S & F of ceiling rose surface bakelite of three terminals 240 Volts complete all as specified and directed.
280
-
-
S & F of lamp holder insulated body. Make of item No 101 to 109 : Anchor / CONA (WAWA) / Havells / Legrand.
18
-
-
M & L in replacement of sub main wiring with two single core of 4 sqmm copper conductor FRLS, PVC insulated and unsheathed multi-stranded cable including PVC conduit medium grade of 25 mm dia, concealed in / surface on walls for sub main connection and 4 sqmm FRLS, PVC insulated and unsheathed multi-stranded green colour copper conductor cable as an earth wire to common earth and connected to earth dolly complete all as specified and directed. Make of cable : Finolex/Polycab/ Havells/Plaza/Grandlay/ Gloster, Make of conduit : AKG/D-PLAST/FINOLEX/PLAZA as approved by GE
250
-
-
M & L in replacement of sub main wiring with two single core of 6 sqmm copper conductor FRLS, PVC insulated and unsheathed multi-stranded cable including PVC conduit medium grade of 25 mm dia, concealed in / surface on walls for sub main connection and 6 sqmm FRLS, PVC insulated and unsheathed multi-stranded green colour copper conductor cable as an earth wire to common earth and connected to earth dolly complete all as specified and directed. Make of cable : Finolex/Polycab/ Havells/Plaza/Grandlay/ Gloster, Make of conduit : AKG/D-PLAST/FINOLEX/PLAZA as approved by GE
450
-
-
M & L in replacement of sub main wiring with four single core of 16 sqmm copper conductor FRLS, PVC insulated and unsheathed multi-stranded cable including PVC conduit medium grade of 32 mm dia, concealed in / surface on walls for sub main connection and 16 sqmm FRLS, PVC insulated and unsheathed multi-stranded green colour copper conductor cable as an earth wire to common earth and connected to earth dolly complete all as specified and directed. Make of cable : Finolex/Polycab/ Havells/Plaza/Grandlay/ Gloster, Make of conduit : AKG/D-PLAST/FINOLEX/PLAZA as approved by GE
50
-
-
S&F in replacement of old light fitting with LED tube light fitting high efficiency extruded aluminium housing linear batten 20/22 watt fixed on wall/ceiling complete with all accessories along with LED tube rod 20/22 watt and provision of three core flexible of 1.50 Sqmm copper conductor cable from ceiling rose to light fitting and other fixing arrangement as required at site complete all as specified and directed..Make:- Philips Cat Part No BN021C LED 20S PSU NW GR / Wipro TRIM LED LL20-281-XXX-65AL1 / Havells cat part no ENDURALINEARNEOBS 20WLED865SPCWH /Bajaj cat part no BCLAB 20W or technocommercially equivalent of Cromton Greaves/C&S Note : Contractor will submit guarantee/warranty certificate from manufacturer.
200
-
-
S & F in replacement of LED mirror light fitting 10/11watt, 6500K, IP65, with efficient heat dissipation & intigrated electronic driver complete including connecting electrically with 1.5 sqmm 3 core wire all as specified and directed. Make : Havells Cat part no LUMILINEPLUSBS10 WLED865SPCSS / Wipro LL20-111-XXX-65NE3 /Bajaj Cat part no BCLSB 10NW/C&S cat part no NAKSHATRA/10W LTTB2F10WLED/W or technocommercially equivalent of Philips/Cromton Greaves/C&S as approved by GE.Note: Contractor will submit guarantee/warranty certificate from manufacturer.
12
-
-
S&F in replacement of LED wall security light 25 watt, pressure die- cost aluminium IP-66 road way luminaries with high power LED as light source with acrylic cover with suitable size bracket fixed with clamps, nut bolt, washer and provision of three core flexible of 1.50 Sqmm copper conductor cable from ceiling rose to light fitting complete all as directed Make: Havells cat part no SL25WLED 757SASYTOPCMP/ WIPRO cat part no LR02-291-xxx-57-xx/ C&S cat part no INDUS-E/25W LTESSE25WLED/Bajaj cat part no BCLST25WLEDIV2 or technocommercially equivalent of Philips/Cromton Greaves as approved by GE.Note: Contractor will submit guarantee/warranty certificate from manufacturer.
8
-
-
S & F in repair of sheet metal enclosure factory made, TPN DB 4 way ,MCB Metallic modular distribution board (Vertical DB), 415 Volts, including 1 x MCCB 100 A, 4 pole, 25 KA as incomer, MCB SP (5-32A) - 12 Nos as outgoing with shrouded neutral bar & pan assembly with suitable flexible connecting link with neutral and earth bus bar having IP-43 protection and double metal door concealed / flush to wall surface including making connections with thimbles as required complete all as specified and directed. Make : (i) Schneider / L & T / Legrand/Indo Asian/C&S/Havells (Note : MCB DB & MCCB / MCB any type should be same make) (ii) The cost of MCCB and MCBs shall deemed to be included in the unit cost.
3
-
-
S & F in repair of sheet metal enclosure double door factory made MCB distribution board Single pole and neutral 240 Volts, 8 way with neutral and earth bus bar having IP-43 protection and double door metal concealed/flush to wall surface including making connections with thimbles as required complete all as specified and directed. Make : Schneider / L & T / Legrand/Indo Asian/C&S/Havells
18
-
-
S&F of MCB single pole, 6 to 32 Amps, 240 Volts, 10 KA complete all as specified and directed. Make: Legrand/Havells/Indo Asian/Schneider/ABB as approved by GE.
108
-
-
M&L MCB SPN, 240 volts 32 to 63 amps,with rupturing capacity 10 KA using thimbles of required size. Make : Schneider / L & T / Legrand/Indo Asian/C&S/Havells
18
-
-
Supply and fix single pole and neutral enclosue with a top pin and earth plug and socket complete with one SPN MCB 25 Amp 240 Volt Make : Havells Cat Part No. DHDMCDPO253025 or equivalent make of Legrand/Siemens/ABB/Indo Asian
6
-
-
Disconnecting electrically, taking down existing ceiling/exhasut fan any type and capacity with due care, for servicing, strip opening of fan, including servicing and greasing complete reassembling and refixing to the same/other location including testing of fan after servicing for smooth and noise free operation complete all as spfd and directed.
6
-
-
Disconnecting electrically, taking down existing electric geyser any type and capacity with due care, and refixing on the same or other location including grouting with suitable size of nut/bolts or fastner and making electric connection and testing on completion complete all as spfd and directed.
6
-
-
M&L for earthing with galvanised steel earth plate electrode 600x600x6mm thick buried directly in the ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below the ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washers of galvanised or steel all as specified or shown in electrical plate of SSR (Part-l) including necessary excavation, earth work, GI pipe 15 mm dia light grade for protection of galvanised iron earthing wire, GI pipe 20 mm dia light grade watering pipe etc. including concrete chamber of PCC 1:2:4 type B-2 (using 40mm graded stone aggregate), copping in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate), internal surface of concrete chamber shall be plastered with 12 mm thick cement mortar 1:4 and 50 mm thick RCC cover in pre-cast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) duly reinforced with 8 mm dia1or bar @ 80 mm c/c both ways and charcoal dust, common salt etc. including testing after completion complete all as specified and directed.
3
-
-
Disconnecting and taking out existing unserviceable LT Cables of sizes upto 50 sqmm 3.5 core in any position and removing from site complete all as specified and directed by Engineer-in-Charge.
100
-
-
Supply laying , jointing, testing and commissioning of XLPE insulated, PVC sheathed, strip armoured heavy duty electric cable with aluminium conductor (stranded) working voltage upto 1100 volt confirming to IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of aluminium lugs duly crimped with die press crimping device and cable gland of size 50 Sqmm 3.5 core complete all as specified and directed : Make: Gloster/Havells/ Paragon/ Grandlay/Finolex Note : 1.Necessary excavation and earth work , sand cusioning, cable cover will be measured and paid separately.
100
-
-
Excavation in trenches / foundation in soft / loose soil not exc. 1.5 metre wide and n'exc. 1.5 m deep for LT under ground cable and getting out including forming bottom surface to required level or slop, complete all as specified and directed by Engineer-in- Charge.
18
-
-
Returning filling including spreading levelling watering and well ramming in layers not exc 25 cm in soft / loose soil, complete all as specified and directed.
10
-
-
Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed.
8
-
-
M&L for sand cushning to U/G cable in layers of 23cm thick( 8 Cm before laying the cable and 15 cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed. Note: Only punned thickness 18 cm shall be measured and paid.
7
-
-
Supplying and laid flat sub class 'B' bricks, old size, laid dry in trenches for the protection of U/G cable, complete all as specified and directed.
0.8
-
-
Supply & laying in replacement of GI tubing of 50 mm bore dia, light grade conforming to IS 1239- Part-I and ISI marked, in trenches, along pole, culvert etc of required length for cable protection complete all as specified and directed.Make: Jindal / Tata / Prakash Surya as approved by GE.
12
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements