Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical Cables And Wires
Electrical and Electronics
Eprocure
Opening Date4 Jan 2024
Closing Date30 Jan 2024
Tender Amount₹ 47,49,500
Costs
EMD
₹ 95,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_635747_1Bid Award Id
ViewTender No
8854/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply , laying, jointing and testing (in replacement) of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
200
-
-
Supply , laying, jointing and testing (in replacement) of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core aid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
250
-
-
Supply , laying, jointing and testing (in replacement) of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
190
-
-
Supply , laying, jointing and testing (in replacement) of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
160
-
-
Supply , laying, jointing and testing (in replacement) of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
180
-
-
Supply , laying, jointing and testing (in replacement) of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
850
-
-
Supply , laying, jointing and testing (in replacement) of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
1010
-
-
Excavation in trenches not exceding 1.5m wide and noe exceding 1.0 sq m on plan and not exceding 1.5m depth and getting out soft soil all as specified and directed
820
-
-
Returing filling in including spreading leveling watering and well ramming in layer not exceding 25 cm as in soil all as specified and dirceted all as specified and directed
600
-
-
Removing excavated material not exceding 50 m and depostingwhere directed at a level not exceding 1.5 m above the starting pointall as specified and directed
220
-
-
M & L for sand cushioning all around the cable for protection by natural sand all as specified and directed
245
-
-
Supplying and Laying old size bricks of size 230mm x 113 mm x 75 mm for cable protection all as specified and directed
24.15
-
-
Supply and Laying in trenches for road/plinth and fixing alongwith pole/wall GI Tube 80 mm light grade for protection of cable all as specified and directed
30
-
-
Supply and Laying in trenches for road/plinth and fixing alongwith pole/wall GI Tube 50 mm light grade for protection of cable all as specified and directed
45
-
-
Supply and Laying in trenches for road/plinth and fixing alongwith pole/wall GI Tube 40 mm light grade for protection of cable all as specified and directed
120
-
-
M & L for boring holes (manually) under road, hard standing without damaging surface for 80/50/40 mm dia GI pipe etc complete all as specified and directed
100
-
-
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 300/240 sqmm, Outdoor type complete all as pecified and directed by Engr-in-charge.
2
-
-
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 185/150 sqmm, Outdoor type complete all as pecified and directed by Engr-in-charge.
4
-
-
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 120/95 sqmm, Outdoor type complete all as pecified and directed by Engr-in-charge.
6
-
-
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 70/50 sqmm, Outdoor type complete all as pecified and directed by Engr-in-charge.
5
-
-
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 35 sqmm, Outdoor type complete all as pecified and directed by Engr-in-charge.
4
-
-
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 4 core XLPE, armoured, Al conductor cable of size 25/16 sqmm, Outdoor type complete all as pecified and directed by Engr-in-charge.
6
-
-
Taking up old U/S LT UG cable of size between 10 to 16 Sqmm 4 core all as specified and directed.
260
-
-
Taking up old U/S LT UG cable of size between 25 to 35 Sqmm 3.5/4 core all as specified and directed.
380
-
-
Taking up old U/S LT UG cable of size between 50 to 70 Sqmm 3.5 core all as specified and directed.
350
-
-
Taking up old U/S LT UG cable of size between 95 to 120 Sqmm 3.5 core all as specified and directed.
450
-
-
Taking up old U/S LT UG cable of size between 150 to 185 Sqmm 3.5 core all as specified and directed.
410
-
-
Taking up old U/S LT UG cable of size between 240 to 300 Sqmm 3.5 core all as specified and directed.
170
-
-
S&F (in replacement) following items in the existing out door/ indoor LT panels and connection with using aluminum lugs/ferruls incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection complete all as specified and directed as below :-
-
-
-
MCCB 4 Pole 100 amps rating, 16 KA breaking capacity, 415 Volt
5
-
-
MCCB 4pole 125 amps rating, 16 KA breaking capacity with spreader at both side
6
-
-
MCCB 4 pole150/160 amps rating, 36 KA breaking capacity with spreader at both side
4
-
-
MCCB 4 pole200 amps rating, 36 KA breaking capacity with spreader at both side
5
-
-
MCCB 4 pole250 amps rating, 36 KA breaking capacity with spreader at both side
8
-
-
Microprocessor based MCCB 4pole 250 amps rating, 36 KA breaking capacity with spreader at both side
5
-
-
Microprocessor based MCCB 400 amps rating, 36 KA breaking capacity with spreader at bothe side
2
-
-
Volt meter (0 to 500 volts) anolog type with selector switch for three phase
3
-
-
Amp meter (0 to 500 amps) anolog type, witch selector switch for three phase measurement .
3
-
-
CTs of existing ratio and capacity fixed in LT panels and connect with ammeter
4
-
-
Indicator lamp, LED type incl 1.5 sqmm wire for connection to desired point of bus bar.
5
-
-
MCB TPN 100 amps, 'C' series, 415 volt
12
-
-
Microprocessor based MCCB 630 amps rating, 50 KA breaking capacity with spreader at bothe side
1
-
-
Supply and fixing in replacement of three phase combination of Nature timer switch-02 (sensor) based illuminance level for switching ON 60 Lux & for switching OFF 10 Lux & Analog Timer for part-night operation facility of minimum 04 hrs to maximum 12 hrs with hensel enclosure integrated models of rating 32 Amps, suitable contactor, incoming and outgoing MCBs and enclosure etc conforming to IP 66 protection type all as specified and directed. Cat part Swadeep-02EC-8kW3P- DUAL make: Swadeep or its equivalent as approved by Engr-in-Charge.
11
-
-
Supply and fixing in replacement of Single phase combination of Nature timer switch-02 (sensor) based illuminance level for switching ON 60 Lux & for switching OFF 10 Lux & Analog Timer for part-night operation facility of minimum 04 hrs to maximum 12 hrs with hensel enclosure integrated models of rating 63 Amps, suitable contactor, incoming and outgoing MCBs and enclosure etc conforming to IP 66 protection type all as specified and directed. Cat part Swadeep-02EC-8kW1P- DUAL make: Swadeep or its equivalent as approved by Engr-in-Charge.
6
-
-
Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
600
-
-
Supply and fixing in replacement of contactor ML-6 type all as specified and directed by engr-in - charge
12
-
-
Supply and fixing (in replacement) 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN, 32 amp current carrying capacity, complete with connection testing and commissioning complete all as specified and directed by Engr-in-charge
12
-
-
Supply and fixing (in replacement) 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN, 63 amp current carrying capacity complete with connection testing and commissioning complete all as specified and directed by Engr-in-charge
10
-
-
Supply and fixing in replacement of KIOSK junction box of size 205x255x112 suitable for 10-25 sqmm cable connection of packing quantity-02Nos, IP 65 protection all as specified and directed by Engr-in-charge
76
-
-
Supply and fixing (in replacement) Nature timer switch-02 (sensor) based illuminance level for switching ON 60 Lux & for switching OFF 10 Lux & Analog Timer for part-night operation facility of minimum 04 hrs to maximum 12 hrs complete all as specified and directed
10
-
-
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
-
-
-