Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date11 Jan 2024
Closing Date8 Feb 2024
Tender Amount₹ 10,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width not exceeding 60 cm in depth for passing of GI/CI pipes all as specified and directed .Note : Making good with PCC shall be measured and paid separetely under respective item.

20

-

-

... More
M & L for cement concrete(1;2;4) type B-0 using 12.50 mm graded granite stone aggregate for repairing to disturded surfaces complete all as directed.

3

-

-

... More
M&L for replacement of cast iron special fittings such as bends (any type, radius and angle) tapers any type, (straight bend, increasing, decreasing or double socket etc) Tee pieces single branch. Y junction double branch cross (all sockets or socket and spigot) collers, caps and plugs for upto 150 mm bore in mm all as specified and directed

50

-

-

... More
M&L for replacement of connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth for upto 150 mm bore all as specified and as directed.

45

-

-

... More
Material & Labour to repair leakages through lead joints from existing CI pipe, fittings, tee, bends tail pieces, connecting pieces etc by using previously used and additional run lead , spun yarn including caulking to make the joints water tight including excavation works as required complete all as specified and directed for the following bore pipe line :-

-

-

-

... More
(a) 150 mm bore pipe

6

-

-

... More
(b) 100 mm bore pipe

5

-

-

... More
(c) 80 mm bore pipe

5

-

-

... More
Taking up/ down of following bores of steel tubing and connections from excavated trenches and building up to tripple storey with due care from site complete all as specified and directed.

-

-

-

... More
(a) 15 mm nominal bore

60

-

-

... More
(b) 20 mm nominal bore

400

-

-

... More
(c) 25 mm nominal bore

50

-

-

... More
(d) 40 mm nominal bore

24

-

-

... More
(e) 50 mm nominal bore

24

-

-

... More
Supply & Fixing for replacement of following bore of GI tube medium grade/ ISI marked complete with all fittings (such as bends, elow, tees, connectors, caps, plugs, unions etc) including cutting, screwing as required and fixed to wall or roof or laid in plinth protection floor including fixing wall hooks, cutting through wall, floors etc and making good the disturbed surface with cement mrtar 1:3 after fixing the tubes complete all as specified and directed. Make – Jindal /Tata//Prakash Surya.

-

-

-

... More
(a) 15 mm nominal bore

30

-

-

... More
(b) 20 mm nominal bore

200

-

-

... More
Re-fixing old steel tubing and connection in new or old position in trenches/wall/ ceiling/ floors etc with using all new fittings complete including making good the disturbed portion as per existing pattern (PCC, road, path etc) as directed for the following bore pipe line :-

-

-

-

... More
All as per item No 11 but size 15mm bore

30

-

-

... More
All as per item No 11 but size 20mm bore

200

-

-

... More
All as per item No 11 but size 25mm bore

50

-

-

... More
All as per item No 11 but size 40mm bore

24

-

-

... More
All as per item No 11 but size 50mm bore

24

-

-

... More
Supply and fix in repair of Bib tap 15 mm size ISI marked standard of PTMT any colour high pressure screwed for iron pipes and fixed. Make Prayag /polytuf/symet

30

-

-

... More
Supply & Fix Gland packing suitable for 200/150mm dia sluice valve ISI marked allasspecifiedand directed by GE (I) R& D Kanpur.

20

-

-

... More
Testing of drinking water for chemical analysis as per IS 10500 .2012 guideline after lifting the sample from Pump as per testing guidline enumerated in test Physical Parameter ( PH Value,Turbidity,colour,odour) Chemical Parameter ( Ammonia free& saline, Ammonia Albuminoid,O2 absorbed,Nitrates,chlorides,Hardness temp& Permanent ,TDS,Metal Iron ,Manganease,Zinc,Calcium,Magnesium,Sulphate,Phenolic Substances) all as directed by Engr-in-Charge. Make Bharat test House/HBTIKanpur/Spectro /Balajee Lab

3

-

-

... More
Supply, fixing, connecting, lifting & lowering MS column pipe of 150 mm nominal dia having wall thickness not less than 7.0 mm in 3.0 Mtr length, coupled/threaded and welded with MS Flange of 12 mm thick on both end with supporting ribs (4 Nos.) including jointing with rubber or fiber board gasket with all nuts, bolts and washer set and making edge cutting for passing the submersible cable complete in all respect and directed.

4

-

-

... More
Supply and fix in replacement of air release valve flanged type 150 mm dia complete with fixing all as required and directed at site.

1

-

-

... More
Material and Labour for brick masonry valve pit chamber of size 1200mm x 1200mm x 1200 mm (internal) complete with PCC (1:3:6) type C-2 for foundation, brick work in Cement Mortar (1:6), 15 mm thick plastering in Cement Mortar (1:4) (internally) including 6.0 mm thick MS plate covering and angle iron frame of 40mm x 40mm x 6.0 mm including coping, 100 mm thick, PCC flooring in 1:2:4 type B-1 and two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces with locking arrangement complete all as specified and directed.

2

-

-

... More
Material and Labour for brick masonry valve pit chamber of size 1000mm x 1000mm x 1000 mm (internal) complete with PCC (1:3:6) type C-2 for foundation, brick work in Cement Mortar (1:6), 15 mm thick plastering in Cement Mortar (1:4) (internally) including 6.0 mm thick MS plate covering and angle iron frame of 40mm x 40mm x 6.0 mm including coping, 100 mm thick, PCC flooring in 1:2:4 type B-1 and two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces with locking arrangement complete all as specified and directed.

2

-

-

... More
Material and Labour for brick masonry valve pit chamber of size 800mm x 800mm x 800 mm (internal) complete with PCC (1:3:6) type C-2 for foundation, brick work in Cement Mortar (1:6), 15 mm thick plastering in Cement Mortar (1:4) (internally) including 6.0 mm thick MS plate covering and angle iron frame of 40mm x 40mm x 6.0 mm including coping, 100 mm thick, PCC flooring in 1:2:4 type B-1 and two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces with locking arrangement complete all as specified and directed.

2

-

-

... More
Labour for daily maintenance of chloronome plant (Granuals based dosing plant) as per manufacturers reccomendation which include the following::- (i) feeding of chlorine in appropriate manner,Cleaning of plant room once in a week. (ii) Daily Checking of Chlorination plants /testing of complete system for serviceability of plant. (iii) Daily Testing of chlorine at consumer end with medical authority and maintained chlorine test record . (iv) Routine maintenance and servicing of Agitator of by using necessary lubricant, replacement of bush/bearing, alingning the shaft , key etc. all as directed. Note : (i) If any defect found in plant contractor should rectify the defect with in 24 Hrs, if failed to rectify the decfect the contractor shall be liable to pay compensation Rs 500/- (Rupees five hundred only) per plant per day. (ii) clorine/calcium hypocloride will measured and paid in relevant item.

600

-

-

... More
S&F Gear motor as per existing 230 volt, 50 Hz complete all as specified and directed.

1

-

-

... More
S&F Roller assembly as per existing model complete all as specified and directed.

1

-

-

... More
S&F Pump tube as per existing model complete all as specified and directed.

1

-

-

... More
S&F Injection check valve 3/8" size.as per existing model complete all as specified and directed.

1

-

-

... More
S&F Weightned suction line strainer 3/8" size.as per existing model complete all as specified and directed.

1

-

-

... More
S&F Agitator Shaft with impeller made poly propylene rigid 32 mm dia and 500 mm length complete as per existing model complete all as specified and directed.

2

-

-

... More
S&F Check valve duck bill as per existing model complete all as specified and directed.

2

-

-

... More
S&F of PVC Tubing suction /discharge line 3/8" size heavy duty as per sample complete all as specified and directed..

10

-

-

... More
M&L for replacement of Dosing Pump High Pressure Single Head Gear Motored Adjustable dosing pump with accessories including Lead Tubing, Connecting Nuts, Injection Check Valve,Clay Weight, and Ferrules all as directed.

1

-

-

... More
M&L for replacement of agitator motor of capacity 120 watts, 920 RPM single phase 230 V with impeller Shaft made poly propylene rigid 32 mm dia and 500 mm length and blade complete all as directed.

1

-

-

... More
M & L for rewinding of agitator motor of capacity 120 watts, 960 RPM single phase 230 V and using copper winding wire of existing gauge with necessary insulation material including testing after repair and refixing of the same complete all as directed.

1

-

-

... More
Taking out the defective submersible pump set of 20000 GPH capacity with 30/40/41 HP motor from bore well with column pipe rope cable and other accessories etc and depositing as where directed.

3

-

-

... More
Lowering submersible pump set of 30/40/41 HP with three phase electric motor suspended including column pipe of 3.0 metre each or to replace the worn out column pipe to avoid any leakage in bore by unscrewing the nut & bolts at flange joints, steel rope , submersible cable and lowering , commissioning the same after rectification complete all as specified and directed.

3

-

-

... More
Repair and rewinding of submersiable pump set of capacity 30/40/41 HP with PVC insulated /coated copper winding wire of existing gauge with other winding material including rewinding of motor, repalcement of insulating paper sleeves bamboo sticks etc as per starnadrad manufacturer specification including cleaning of starter slots and replacement of defective parts and testing complete all as specified and directed by Engr- In - Charge

2

-

-

... More
Dismantling of pump and motor set complete cleaning all dismentalled spare/parts /winding for inspection of Engg in charge to acrtain the scope of works for repair and replacements

2

-

-

... More
Machining work required for repair to submirsible pump set by straightning polishing of pump shaft. Making screw and key way, including replacement of wornout parts re-assembling pump after repair for smooth functioning of pump. Note:- Fixing payment shall be deemed to be including in quoted rates.

2

-

-

... More
Supply only components/spare parts of existing discription and make for the submersible pumps and motors of capacity as under:-

-

-

-

... More
(a) SS impellers with Key and distance bushes suitable for 20000 GPH

8

-

-

... More
(b) NRV for sunmersible pump set 20000GHP

2

-

-

... More
(C) Bearing bush upper & lower for submersible pump for 20000 GPH

6

-

-

... More
(d) Neck ring submersible pump set 20000 GPH

4

-

-

... More
(e) Distance sleeves for 20000GPH

8

-

-

... More
(f) High tensile nut bolts suitable for 20000 GPH pump.

60

-

-

... More
(g) GM motor bush upper and lower (set of two)

4

-

-

... More
(h) Rotor bearing sleeve upper and lower

4

-

-

... More
(i) Coupling with key for motor pump

2

-

-

... More
(j) Sand Guard for submersible pump set

2

-

-

... More
(k) Housing upper & lower

4

-

-

... More
Supply & Fixing in replacement ML - 3 Type three Pole Power contactor conforming to IS:13947-4-1/IEC:60947-4-1 having 02 NC & 02 NO auxilary contacts, AC operated of coil voltage 240 /415 Volt, 50 Hz AC 3 rating 70 A, ACI Rating 100A Make - L&T / Havells/ Siemens/ HPL as approved by GE(I).

1

-

-

... More
Dismantling & taking out old u/s worn out 415 Volt, 3 Phase, 4 Wire system, Main LT Panel board ( Indoor Type/outdoor type ) of any size with complete accessories after taking proper shutdown from concern staff and disconnecting all incoming & outgoing cables with due care complete with making the disturbed surface smooth all as specified and directed.

1

-

-

... More
Supply of water pressure gauge, 100 mm dial size of range 0 to 7.0 Kg/Cm2, Accuracy ± 2% with pressuge gauge cock complete all as specified and directed. Make - RMCO/Fiebig/Mass/Hy tech or as approved by GE(I)

1

-

-

... More
S&F in replacement Single phase preventer VSP 3 auto reset 50 Volts unbalanced type complete all as specified and directed. Make -Minilec/L&T/Schnedier approved by GE(I)

1

-

-

... More
M&L for disconnecting and stopping of incoming and outgoing pipes of RCC over head tank cap. 1,00,000 gallen by means of hassen cloth to avoid choking of distribution pipe lines,removing total water ,frame the over head tank,cleaning tank complete with steel brush re moving complete settled dirt /sand/silt and flushing the complete tank through wash out pipes,cleaning of pipes(Rising delivery wash out over flow pipes).Sluice valve of any size including painting with coats after cleaning surface of pipes with existing shade of synthetic enamel paint and date of cleaning shall also be mentionedon over head tank of pillar with synthetic enamel paint as approved by Engr-in-Charge at site complete all as specified and directed Note:- (a) The work shall be carried out through traned staff with hygiene and safety equipment. (b) Responsibility for insurance and safety of team will solely rest with the contractor.

1

-

-

... More
All as per serial item No 42 above but 75000 gallon capacity

1

-

-

... More
S & F in replacement Digital AC Volt meter ( 0 to 500/600 Volt) , square size, flush mounted case, complete all as specified and directed Make: L&T (Risabh) /AE/Secure/Kaycee as approved by GE(I)

1

-

-

... More
S & F in replacement Digital AC Ammeter ( 0 to 200 Amp ), CT Operated - 5 Amps square type, flush mounted case,complete all as specified and directed of Make: L&T (Risabh)/AE/Secure/Kaycee as approved by GE(I)

1

-

-

... More
Supply & Fixed in replacement Gun metal Gate valve with iron wheel head conforming to IS : 778/ 1984, Class-1, Screwed both end as per IS: 554 Parallel, ISI marked including taking out the worn out/ old GI gate valve complete all as specified and directed of the following sizes :-

-

-

-

... More
All as per item No 46 but size 50mm bore.

4

-

-

... More
All as per item No 46 but size 40mm bore.

5

-

-

... More
All as per item No 46 but size 25 mm bore.

2

-

-

... More
All as per item No 46 but size 20mm bore.

20

-

-

... More
All as per item No 46 but size 15 mm bore.

1

-

-

... More
Supply & fix in replacement of cast iron non-return valve 150 mm dia ISI marked with CML No including nut ,bolt ,washer and rubber packing complete all as specified :-Make Kirloskar/Upadhaya/ Zoloto/Leader

2

-

-

... More
supply of calcium Hypo chlorite having 65% to 70% chlorine content Granular Chlorination Chemical (Water Treatment Chemical ), free flowing granular material free of foreign matter in 45 Kg in sealed packing complete all as specified and directed.Make as approved by GE (I) Note :-Cost of labour for use of items shall be measured and paid separately under items of 24 of Sch A.

1575

-

-

... More
Routine/periodical cleaning the inside area of pump area including cutting/removal of uprouting of unwanted grass,bushes and small trees near all around sub station and pump house complex complete including surface dressing and levelling by surfave excavation complete all as directed.

900

-

-

... More
M&L for painting of CI/MS pipe line with existing colour by means of scafolding of following sizes.

-

-

-

... More
(a) 200 mm dia

20

-

-

... More
(b) 150 mm dia

40

-

-

... More
S&F in replacement of flat PVC Insulated & Sheathed Industrial Submersible Cables with Bare Bunched Copper Conductor for Submersible Pump Motors with Voltage Grade 1100 Volts generally conforming to IS 694/1990. of size16 Sqmm x 3 core including connecting both end with proper size of copper lugs duly crimped with die press crimping device complete all as specified and directed by GE (I).

125

-

-

... More
Total amount with taxes in Figures

-

-

-

... More
Total amount with taxes in words

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.