If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Solar Installation and Products
Electrical Works
Eprocure
Opening Date8 Jul 2024
Closing Date16 Sep 2024
Tender Amount₹ 31,00,000 
Notes
Download

Costs

Summary

8124/sar-t-39/2024-25 Repair Of Certain Internal Electrification Incl Fans Geysers And Connected Items, Repair/maint Of External Water Supply Line, Repair/maint Of Summer Cooling Appliances, Solar Heaters And Connected Items At 1 Afsb Dehradun Under

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No 2 here in before but One socket out let 5 Amps 5 pin on independent board

10

-

-

... More
All as per item No 2 here in before but One socket outlet 5 Amps 5 Pin on same board with other switches

15

-

-

... More
All as per item No 2 here in before but with cable size 2.5 Sq mm for one 5 pin 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 1.5 sqmm all as specified and directed by Engr-in-Charge. (circuit to be laid seperatly )

8

-

-

... More
M&L for point wiring with 1.5 Sq mm nominal area PVC insulated and unsheathed cable single core FRLS copper cable 1100 Volts with multistranded, copper conductor in and including PVC non metalic casing capping of size not less than 25 mm ss and all required accessories along with continous earth wire 1.5 sqmm PVC insulated and unsheathed single core FRLS cable 1100 Volts grade with standard copper conductor and connected to common earth dolly, with and including cadmium plated sunk Modular metal flush boxes for modular switches complete all as specified and directed, One light point controlled by one switch one way . (Note:- modular white cover and plate with frame will be measured and paid saperately under respective item)

35

-

-

... More
All per item No 7 here in before but one ceiling fan point controlled with one 5A switch

18

-

-

... More
All per item No 7 here in before but one exhaust fan point controlled with one 5A switch

5

-

-

... More
All per item No 7 here in before but one 3 pin socket outlet 5Amps on independant board.

10

-

-

... More
All per item No 7 here in before but one 3 pin socket outlet 5Amps on same board with other switches.

14

-

-

... More
All as per item No 6 here in before but with cable size 2.5 Sq mm for one 5 pin 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 1.5 sqmm all as specified and directed by Engr-in-Charge. (circuit to be laid seperatly )

10

-

-

... More
Supply and fix in repair modular switch 1 way 6 amps 1 module.

156

-

-

... More
Supply and fix in repair modular socket outlet 2/3 pin 6 Amps combined 2 module

49

-

-

... More
Supply and fix in repair modular socket 6A/16 A-2/3 pin combined 2 module.

10

-

-

... More
Supply and fix in repair modular switch 1 way 16 amps 1 module.

18

-

-

... More
Supply and fix in repair modular Bell push 6 A 1 module.

6

-

-

... More
Supply and fix in repair Buzzer,Ding Dong AC.230 Volts,single pole

6

-

-

... More
Supply and fix in repair Fan step regulator,120 W -2 module.

28

-

-

... More
Supply & fix in repair white modular cover plate with frame for fixing of modular switches of following :- 2 module

4

-

-

... More
All as per item No 20 here in before but 3 module

12

-

-

... More
All as per item No 20 here in before but 4 module

14

-

-

... More
All as per item No 20 here in before but 6 module

18

-

-

... More
All as per item No 20 here in before bu Ditto but 8 module

16

-

-

... More
All as per item No 20 here in before but12 module

14

-

-

... More
S& F blank spacer plate for single module

8

-

-

... More
S&F in replacement of MCB distribution board VTPN, 4 way double door type including with MCCB 4 Pole, 63 Amps, 16 KA fixed type as incomer with 200 amp rated bus bar incl lugs/timbles making good the disturbed surface complete all as specified.

4

-

-

... More
Taking down old unserviceable TPN DB and supply & fix in repair MCB distribution board triple poele and neutral 4 way double door factory made sheet steel, phosphates, powder coated with 200 Amps rated bas bar, 415 volts, neutral link, earth bar and Din rail and making good disturbed surfaces of walls, floors, etc. complete all as specified.

2

-

-

... More
Taking down old unserviceable DB and supply & fix in repair MCB distribution board single pole and neutral 12 way double door factory made sheet steel, phosphates, powder coated with 200 Amps rated bas bar, 240 volts, neutral link, earth bar and Din rail and making good disturbed surfaces of walls, floors, etc. complete all as specified.

4

-

-

... More
Taking down old unserviceable DB and supply & fix in repair MCB distribution board single pole and neutral 8 way double door factory made sheet steel, phosphates, powder painted with 200 Amps rated bas bar, 240 volts, neutral link, earth bar and Din rail complete including making good disturbed surfaces of walls, floors, etc. complete all as specified.

4

-

-

... More
Taking down old unserviceable DB and supply & fix in repair MCB distribution board single pole and neutral 6 way double door factory made sheet steel, phosphates, powder painted with 200 Amps rated bas bar, 240 volts, neutral link, earth bar and Din rail complete including making good disturbed surfaces of walls, floors, etc. complete all as specified.

6

-

-

... More
Taking down old unserviceable DB and supply & fix in repair MCB distribution board 4 way double door factory made sheet steel, phosphates, powder painted with 200 Amps rated bas bar, 240 volts, neutral link, earth bar and Din rail single door complete including making good disturbed surfaces of walls, floors, etc. complete all as specified.

4

-

-

... More
S&F in repair MCB SP 6 to 32 Amps, 10 KA rating, 240 Volts C Curve type

152

-

-

... More
S&F in repair MCB DP 40 Amps 10 KA rating, 240 Volts C Curve type

26

-

-

... More
S&Fin repair MCB TP 63 Amps 10 KA rating, 415 Volts C Curve type

5

-

-

... More
S&F in repair MCB TPN 63 Amps 10 KA rating, 415 Volts C Curve type

2

-

-

... More
M&L for sub-main wiring with two single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 4 sqmm 1100 volts grade and including non metallic rigid 25 mm dia PVC casing caping with all fitting and fixing accessories and including PVC insulated unsheathed, multistranded copper conductor cable of size 2.5 sqmm for earth continuity conductor and including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed.

390

-

-

... More
S&F in repair sheet metal enclosure with socket plug top and MCB single pole and neutral with two pin and earth plug with one SP MCB 20 Amp 240 volt complete all as directed.

18

-

-

... More
Supply and fix in repair ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified

50

-

-

... More
M&L for Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for batten fittings complete all as directed by engr-in-charge.

30

-

-

... More
Supply and fix inrepair plug top 15A, 240 volts

10

-

-

... More
Supply and fix inrepair plug top 5A, 240 volts

2

-

-

... More
Supply and fix inrepair call bell, Ding dong type, 230 volts AC single pole complete all as directed.

4

-

-

... More
S&F in repair fan regulator electronic step type 40 Watts, complete ISI marked all as specified and directed

20

-

-

... More
S&F in repair fan regulator electronic rotary type 40 Watts, complete ISI marked all as specified and directed

20

-

-

... More
Supply and fix in repair 6 amps single pole switch one way

100

-

-

... More
Supply and fix in repair 6 amps single pole switch two way

10

-

-

... More
Supply and fix in repair bell push 6 A 1 module.

10

-

-

... More
Supply and fix in repair socket outlet 2/3 pin 6 Amps

40

-

-

... More
Supply and fix in repair socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type

40

-

-

... More
Supply and fix in repair 16 Amps switch one way

40

-

-

... More
S&F in repair switch socket combination multipurpose 2 in 1 for 3 pin 15 Amps & 3pin 5 Amp controlled by one switch flush type complete all as specified and directed.

26

-

-

... More
Taking down old unserviceable/broken hylum sheet and supply and fix in repair hylum sheet of size 5" x 5", 3 mm thick with brass screw and washers complete all as specified and directed

10

-

-

... More
All as per item No 53 here in before but size 8" x 5"

8

-

-

... More
All as per item No 53 here in before but 9" x 11"

12

-

-

... More
All as per item No 53 here in before but 9" x 13"

8

-

-

... More
Taking down old unserviceable/rusted sunken box and supply and fix sunken box size 4" x 4",including making good disturbed surface complete all as specified and directed

10

-

-

... More
All as per item No 57 here in before but size 7" x 4"

14

-

-

... More
All as per item No 57 here in before but 8" x 10"

8

-

-

... More
All as per item No 57 here in before but 10" x 12"

6

-

-

... More
Supply and fix in repair gang box 3 module 6 Amp capacity

10

-

-

... More
Supply and fix in repair gang box 4 module 6 Amp capacity

12

-

-

... More
Supply and fix in repair gang box 6 module 6 Amp capacity

11

-

-

... More
Supply and fix in repair gang box 8 module 6 Amp capacity

8

-

-

... More
Supply and fix in repair gang box 4 module 16 Amp capacity

6

-

-

... More
Supply and fixing in replacement of 20 Watt 6500K LED batten 2000 lumens cool light fitting with extruded aluminium housing four feet with integrated LED & electronic driver and all accessories pre-wired including connecting up complete all as directed.

200

-

-

... More
Taking down old broken round sheet from various places and supply and fix in replacement PVC round block complete all as specified and directed.

50

-

-

... More
Supply and fix in repair LED Lamp 12 watt.

50

-

-

... More
Supply and fixing & replacement of LED mirror light fitting, 10 Watt, 1000 lumens 6500K comprises of aluminium extruded channel, frosted diffuser, integrated electronic driver, IP 20 protection and all accessories pre-wired including connecting up complete all as directed.

20

-

-

... More
Supply and fix in replacement bulkhaed fitting 5700k, 10 watt capacity, IP 65 rating along with with die cast aluminium housing with complete assembly and PC opal diffuser for uniform illumination suitable for wall/surface mounted complete all as specified and directed.

25

-

-

... More
Supply and fixing in replacement recessed mounted 3600lumens, 6500K, 2'x2' LED ceiling light fitting with 60mm width CRCA body, opal acrylic diffuser, electronic driver, system life 50000hrs@L70%, PF 0.95, THD 10%, CRI 80,etc and all accessories pre-wired includingconnecting up complete all as directed.

8

-

-

... More
Supply and fix in repair round ultra sleek surface mounted slim aluminium body LED downlight 18 watts complete all as specified and directed by Engineer-in-Charge. Make : C&S/philips/havells

4

-

-

... More
Supply and fix in repair square ultra sleek surface mounted slim aluminium body LED downlight 18 watts complete all as specified and directed by Engineer-in-Charge. Make : C&S/philips/havells

4

-

-

... More
Supply and fix in repair square white powder coated CRCA full glow surface mounted slim aluminium body 2' x 2' LED downlight 36 watts complete all as specified and directed by Engineer-in-Charge. Make : C&S/philips/havells

2

-

-

... More
Supply and fixing LED attractive and decorative strip type Warm lights 11/15 watts,system Lumen Efficiency110 Lm/W operating voltage between 140-270 Vac, power factor more thn 0.90% LED driving current70% of rated maximum forward current, THD less than 20% CRI more than 80%,Luminaire intergal driver with 2 KV surge protection, overload protection,No load protection and BIS marking (Ref no for Driver),Driver certification IEC6437-2-13 IS (15885) Over all electrical Eficiency more than 90%, driver electrical efficiency will be85%..(Note:- Each strip have minimum 5 Mtr lambai, seperate led driver and seperate point wiring. The point wiring and swithes measured seperately.) all as specified and directed.

1

-

-

... More
Supply and fixing & replacement of Recess mounted round LED downlight 6/7 Watt, 1000lumens, 6500K comprises of aluminium die cast housing, frosted diffuser, integrated electronic driver, IP 20 protection, complete all as directed.

10

-

-

... More
Taking down rusted exhaust fan louver of any type and supply and fix in repair exhaust fan louver of tin/iron sheet body flap suitable for exhaust fan upto 400 mm complete all as specified and directed.

30

-

-

... More
Material and labour for painting of ceiling fans complete, in situ with synthetic enamel paint by spray painting including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed

40

-

-

... More
Material and labour for painting of exhaust fans complete, in situ with synthetic enamel paint by spray painting including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed

30

-

-

... More
Material and labour for dismantling ceiling fans for servicing from any location and thoroughly checking the nuts, bolts and rubber reel if necessary replace the defective items, including cleaning the fans. Re-fixing the same at the location complete all as specified and directed.

240

-

-

... More
Rewinding of unserviceable ceiling fans of size1200/1400mm sweep with approved copper enamelled wire of suitable gauge, varnishing, replacing existing split/quater pins, rubber bushing, capacitor 2.5 Mfd and testing complete all as specified.

35

-

-

... More
Rewinding of exhaust fans of size 225/300 mm sweep with approved copper enamelled wire of suitable gauge varnishing replacement of capacitor, rubber packing, suitable size bearing , bush etc and testing complete all as specified & directed

20

-

-

... More
S&F in replacement of condenser 2.5 mfd all as specified and directed.

100

-

-

... More
M& L for earthing complete with galvanized steel earth plate electrode 60cm x60 cm x6.0 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to earthing test point all as specified or indicated including testing on completion including PCC pit in (1:3:6) type C-2 cement concrete .RCC 1:2:4 Mix type B reinforced with 6 mm dia MS bars @ 150mm RCC cover slab 40mm thick with two no’s fitting handle, GI pipe 20 mm dia light grade with funnel & wire mesh for watering and 25 mm dia light grade GI pipe for earth wire 4 mm protection etc. complete all as specified and directed by Engr-in-Charge

10

-

-

... More
Exavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for taking out/laying of pipe lines, cables and getting out and forming bottom surfaces to required gradient all as specified and as directed.

94

-

-

... More
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25 centimetre thick in layer in any type of soil complete all as specified and as directed.

85

-

-

... More
Removing excavated materials to a distance not exceeding 50 metres and depositing where as directed at a level not exceeding 1.5 metres above the starting point complete all as specified and as directed .

9

-

-

... More
Demolition cement concrete (un-reinforced) in ground floor and paving n.exc 15cm thickness (below or above ground level) complete all as specified and directed.

1

-

-

... More
Repair to road cutting on PCC path by providing 1:3:6 type C1 in 20 mm graded aggregate 10 cm thick slab complete.

2

-

-

... More
Supply,laying and connection of Ductile iron pipe in replacement with spigot and socket end suitable for rubber gasket tighton hoint centrufugally cast, class LA in any length laid in trenches of 100 mm bore dia including cutting the existing pipe with suitable joints all as specified and directed. Make : Tata/Jindal

100

-

-

... More
Taking up or down steel tubing and connection 20 mm bore including cleaning for re-fixing or removal from site complete all as specified.

20

-

-

... More
All as per item No 91 here-in-before, but 25 mm bore pipe.

48

-

-

... More
All as per item No 91 here-in-before, but 40 to 50 mm bore pipe.

30

-

-

... More
S&F in repalcement of unserviceable 20 mm bore tube medium grade galvanized with all fitting and fixed to wall, ceiling or laid in floor and trench complete all as specified and directed.

40

-

-

... More
All as per item No 94 here-in-before, but 25mm bore pipe.

45

-

-

... More
All as per item No 94 here-in-before, but 40mm bore pipe.

42

-

-

... More
All as per item No 94 here-in-before, but 50 mm bore pipe.

80

-

-

... More
All as per item No 94 here-in-before, but 80 mm bore pipe.

36

-

-

... More
All as per item No 94 here-in-before, but 100mm bore pipe.

30

-

-

... More
Dismantling all electrical connection from centrifugal pump and motor of capacity 35 HP, 415 Volts, 50 Hz, removing coupling, servicing pump, greasing, replacing worn out bearings, packing/gland and refit after completion of work complete all as specified and directed.

1

-

-

... More
Material & Labour for rewinding of motor starter or rotor of 35 HP capacity, 415 Volts, 50 Hz after removing the burnt out winding wire completely, cleaning the slots of stater or rotor throughly and rewinding with same gauge, number of turns, weight of super enamelled specified and as directed of the following sizes:-

1

-

-

... More
Supply and fixing inreplacement stop valve copper alloy , screwed down, high pressure with crutch or butterfly handle screwed both ends, 20 mm bore including fittings and fixtures, as required, complete all as specified and as directed.

5

-

-

... More
Supply and fixed gun metal globe or gate valve of 50mm complete, all as speceifed and as directed.

2

-

-

... More
All as per Serial Item No-103 here-in-above but 40mm bore.

3

-

-

... More
All as per Serial Item No -103 here-in-above but 25mm bore.

12

-

-

... More
All as per Serial Item No -103 here-in-above but 20mm bore.

8

-

-

... More
Supply and fixing inreplacement CI sluice valve class PN-1.6 type of size 80 mm dia ISI marked with iron wheel head brass spindle. Confirming to IS - 14846 flanged ends including rubber joints and jointing material all as required at site including any addition alteration for fixing at site of following size all a directed by Engr-in-Charge.

3

-

-

... More
Supply and fix CI sluice valve class PN-1.6 type of size 100 mm dia ISI marked with iron wheel head brass spindle. Confirming to IS - 14846 flanged ends including rubber joints and jointing material all as required at site including any addition alteration for fixing at site of following size all a directed by Engr-in-Charge.

2

-

-

... More
Supply and fix CI sluice valve class PN-1.6 type of size 150 mm dia ISI marked with iron wheel head brass spindle. Confirming to IS - 14846 flanged ends including rubber joints and jointing material all as required at site including any addition alteration for fixing at site of following size all a directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing in replacement gun metal valve (ISI marked) with spindle and CI wheel, both ends flanged, 80 mm bore including fittings and fixtures, as required, complete all as specified and as directed.

1

-

-

... More
Taking out old unserviceable sluice valve by opening the flanged joints, of 80 mm to 150 mm bore, including cutting the existing pipe, threading , welding etc after dismantling the existing floor, road if required including excavation and earth work complete all as specified and as directed.

1

-

-

... More
Cutting into the existing CI pipe 150/100 mm bore, in position for insertion of Tee, junction etc, of any size, for diversion the pipe line, including necessary excavation and earth work complete all as specified and as directed.

2

-

-

... More
Supply and fixing inreplacement Cast iron fitting such as bends (any type , radius and angle), tapers any type, tee, Y junction, collar , tail piece, dummy plate etc flanged and/or socket ends required upto 150 mm bore pipes including joints and jointing materials for run lead joints and flanged joints complete all as specified and as directed.(Run lead joints shall be measured and paid separately)

45

-

-

... More
Repairing the run lead joints by burning out and taking out the existing run lead and filling the joint with pig lead/lead wool and caulking properly for 150mm bore CI pipe including necessary excavation and earth work complete all as specified and as directed (New Run lead shall not be less than 3.500 Kg per joint and spun yarn 0.30 Kg per joint)

4

-

-

... More
Taking out the unserviceable non return valve 150 mm dia by opening of flange joints supply fixing inreplacement of non return valve 150 mm dia cast iron flanged ends complete with joints and jointing materials all as specified and directed.

1

-

-

... More
Taking out the unserviceable non return valve 100 mm dia by opening of flange joints supply fixing inreplacement of non return valve 100 mm dia cast iron flanged ends complete with joints and jointing materials

1

-

-

... More
Supply and fix MCCB 4 pole, 415 V, adjustable type 160 Amp with braking capacity 35KA .

1

-

-

... More
Supply and fix Pvc insulated 3 core summersible flat cable of size of 25 sqmm for 27.5 HP and 35 HP summersible pumps.

145

-

-

... More
Cleaning of Over Head water tank of capacity 50000 Gallon complete all as speciefied and as directed by engr -in-charge

2

-

-

... More
Cleaning of Under Ground sump of capacity 50000 Gallon complete all as speciefied and as directed by engr -in-charge

1

-

-

... More
Labour only for lifting/taking up of defective submersible pumping set of capacity 27.5 HP-60HP from tube well 110 meter deep approximate dismantling of connected raising main, non return valve, bend etc from delivery of pumping set, lifting of column pipe of size 150/ 100 mm fixed with pumping set column pipe from socket/flange cutting of welded slip unscrewing of cable, holding clamps and disconnecting of submersible cable joint complete and refitting the mortor and pump set and connection with necessary cables and pipes with nuts bolts and lowering the same all as specified and as directed.

2

-

-

... More
Supply and replacement of stainless steel nuts and bolts 5/8 inch dia, 3 inch long, CRC washer 3 mm thick having 16 mm internal dia and 40 mm outer dia complete all as specified and as directed.

3

-

-

... More
Dismantling of motor and pump of capacity 60 HP in to part for repair and over hauling assembling of motor including rotor turning, grinding, polishing and balancing the motor and pump including repair to shaft by means of grinding, polishing and balancing of pump after necessary repair and testing complete all as specied and as directed.

1

-

-

... More
Supply only winding kit with insulating material of 60 Hp Motor.

1

-

-

... More
Supply only bearing bush set of 60 Hp Motor.

1

-

-

... More
Supply only thrust bearing of 60 Hp Motor.

1

-

-

... More
Supply only GM impeller of 60 hp pump

5

-

-

... More
Dismantling of motor and pump of capacity 27.5 HP in to part for repair and over hauling assembling of motor including roter turning, grinding, polishing and balancing the motor and pump including repair to shaft by means of grinding, polishing and balancing of pump after necessary repair and testing complete all as specied and as directed.

1

-

-

... More
Supply only winding kit with insulating material of 27.5 Hp Motor.

1

-

-

... More
Supply only bearing bush set of 27.5 Hp Motor.

1

-

-

... More
Supply only thrust bearing of 27.5 Hp Motor.

1

-

-

... More
Supply only GM impeller of 27.5 hp pump

5

-

-

... More
Supply only Calcium based granual chlorination chemical (Altech-GP) for water treatment 60% to 70% availablen chlorine must contain appropriate quantities of despensants/corrosion enhibitors to note contractor/supplier must submit toxicity free report from Govt institute test report of calcium hypochlorite alongwith each delivery all as specified and directed. Make : Rayalaseema/Declibac Technology or equivalent

265

-

-

... More
M&L for Collecting water sample from any pump houses at 1 AFSB in sterilized glass jar and get it bactoroligical/chemical analysis test from Govt/Approved laboratory complete all as specified and directed.

3

-

-

... More
Supply only Chlorine Test Kit ranging from 0.05 - 5mg/l complete all as specified. Make:- Aquasol Product Code: AE409 or equivalent.

2

-

-

... More
M&L in replacement valve pit chamber of size 1200x1200x1200 mm internal dimension, 6 mm thick MS steel cover with 2 Nos MS hinges suitable size wekded with angle iron frame of 40x40x6 mm thick with lifting hooks and locking arrangement complete with necessary earth work, brick work in cm (1:6) 230 mm thick PCC bed (1:4:8) type D-2, 15 mm thick cement plaster in cm 1:4 internal surface complete and external surface of wall upto 300 mm front top and applying a coat of black bituminious paint to the steel surface complete incl demolition and removal of old u/s valve pit all as specified and directed by Engr-in-Charge.

4

-

-

... More
All as per item No-136 but size 900x900x900 mm

3

-

-

... More
All as per item No-136 but size 600x600x600 mm

3

-

-

... More
Supply only O- Tolidine Reagent (OT Solution) for chlorination testing of 500 ml bottle complete all as specified and directed.

2

-

-

... More
Service and repair of Chloination Dosing Pump Installed in Pump house of any Make any size,completed as specified and directed by Engr-in- Charge. (Note :- Replacement of worn out/unserviceable parts shall be measure separately and paid under respctive items )

2

-

-

... More
Gearmotor complete 230 V 50 Hz, suitable for Altoch decrine dosing pump

1

-

-

... More
Pump head (ferrules 1/4' and duckbill included)

1

-

-

... More
Pump tube

1

-

-

... More
NRV for dosing pump

1

-

-

... More
White Suction/discharge tubing 3/8"

13

-

-

... More
S&F and testing, commencement of star delta star suitable for 75 HP submersible pump along with the enclosure and over current relay, timer, single and three phase protection, multifunctional meter and indicating lamps complete all as specified and directed. Make :- L&T/C&S/equvalent

1

-

-

... More
Taking down old unserviceable pump house board and supply and fix in repair glow sign board showing "PUMP HOUSES NO-2 AGE B/R (AF) DEHARDUN" with radium letter of size 6 x 4 inch covering complete length of main entrance gate along with two legs & frame of stainless steel of size 11.5 x 2 x 0.5 feet along with two nos LED tuble light 20 watt capacity for night illumination complete all as specified and directed.

1

-

-

... More
Air conditioners :- Comprehensive maintenance of air conditioner split type 1.5/2 tonne capacity of any make including performing following tasks at different locations at 1 AFSB Stn :- (a) Inspection, taking down, removing grills and outer housing. (b) Descalingindoor/out door unit fins by means of water pressure technic, brushing and cleaning thoroughly and replacing filter pad of AC. (c) Servicing the cooling fan by greasing/oiling the bearing, bushes after opening the motor, cleaning the armature, checking and tightening all nuts and bolts etc. (d) Checking, rectifying the connection, working of thermostat assembly, relay, condenser, heater assembly, compressor and earth connection etc including replacing defective wire and sleves etc. (e) Re-fixing AC and outer unit of in position, after assembling including packing as required at site and testing complete to make it functional. Note :- Supplying and replacement of parts shall be measured and paid separately.

92

-

-

... More
Gas charging of spilit type AC with gas R-22/F-32 after cleaning including making necessary connection, vacumising, brazing, soldering, welding the copper tube and testing on completion all as specified and as directed.

22

-

-

... More
S & F of running capacitor 36/45/50 MFD including testing complete all as specified and as directed.

8

-

-

... More
S&F of starting capacitor 100/120 MFD including testing complete all as specified and as directed.

8

-

-

... More
S&F of starting relay for AC of capacity 1.5 TR complete all as specified and as directed.

7

-

-

... More
Supply and fixing in replacement compressor assembly (sealed unit) for air conditioner spilit type 1.5 tonne capacity including filling/charging of gas complete all as specified and as directed. Make : Hitachi/Coopeland/equivalent (Note : Gas charging shall be measured and paid separately)

5

-

-

... More
Supply and fixing in replacement compressor assembly (sealed unit) for air conditioner spilit type 2 tonne capacity including filling/charging of gas complete all as specified and as directed.Make : Hitachi/Coopeland/equivalent (Note : Gas charging shall be measured and paid separately)

8

-

-

... More
Supply and replacement of capillary tube complete all as specified and as directed

1

-

-

... More
Supply and fixing in replacement of all coils of blower motor of AC 1.5 tonne split AC with super enamel copper winding wire of proper gauge, weight etc (having same No’s of turn) winding, using insulating material varnishing, heating, re-assembling the motor after making it functional and testing complete all as specified and as directed.

5

-

-

... More
Same as item No 156 here in before but 2 tonne split AC complete all as specified and directed,

4

-

-

... More
S&F in repair wiring kit for AC 1.5/2 ton cap of any make complete all as directed.

3

-

-

... More
S&F of starting relay for AC of capacity 2.0 TR complete all as specified and as directed.

1

-

-

... More
S&F in repair thermostate switch for AC 1.5/2 ton cap all as directed.

3

-

-

... More
S&F in repair sensor remote switch for AC 1.5/2 ton cap all as directed.

3

-

-

... More
Taking out the old/unserviceable heating element from the machine and S&F reversable unit (Hot and Cold) complete all as directed.

2

-

-

... More
M& L for shifting of split type AC of any capacity from one place to another place along with taking down indoor/outdoor unit carefully and re-fixing the same as required incl making good the disturbed surface with existing distumber/paint all as specified and directed by Engr-in-charge.

3

-

-

... More
S&F in repalcement of out door unit PVC insulated grill to protect the fan blade all as specified and directed.

10

-

-

... More
S&F in replacement of outer unit splic AC stand made of 2 mm thick high grade steel with suitable fasteners complete including making good the disturbed surface all as specified and directed.

15

-

-

... More
S&F in replacement of copper pipe 1/2 inch along with brazing complete all as specified and directed.

36

-

-

... More
S&F in replacement of copper pipe 3/4 inch along with brazing complete all as specified and directed.

36

-

-

... More
S&F in repalcement of PVC insulation foam over copper pipe any size all as specified and directed.

50

-

-

... More
S&F in repalcement of PVC inlet hose tube pipe for window/split type AC along with suitable clamps complete all as specified and directed.

100

-

-

... More
Geysers:-:- Inspection and maintenance of water heater (Geysers) of capacity, 25 ltrs to 50 litres including performing the following task at different locations at AF Stn Sarsawa. (a) Removing the heather plate assembly and decaling the heating element/pipe either by use of acid or equa cleaner to make it functional complete. (b) Checking and setting of thermostat between 70 to 80 degree Celsius. (c) Check working of NRV stop cock, pressure release valve and servicing carefully to make it functional. (d) Repairing of earthing connection, power switch, socket connection replacement of indicator lamp to make it functional. (e) Examine water leakage and rectifying as required and replacement of rubber washer gasket etc to make it functional. (f) Inspect over flow vent pipe, safety valve and remove blockage if required to make it functional.

50

-

-

... More
Supply and Fix of heating element ISI marked of rating 2 KW to geyser 25 to 50 litres capacity, any type, complete all as specified and as directed.

25

-

-

... More
Supply and Fix of heating element ISI marked of rating 1.5 KW to geyser 25 to 50 litres capacity, any type, complete all as specified and as directed.

15

-

-

... More
Supply & Fix in repair inner copper tank made out of cold rolled pure electrode type copper sheet double lapped welded internally and hydraulically tested for geyser 35 litres capacity complete all as specified and as directed.

1

-

-

... More
Supply & Fix in repair inner copper tank made out of cold rolled pure electrode type copper sheet double lapped welded internally and hydraulically tested for geyser 25 litres capacity complete all as specified and as directed.

1

-

-

... More
Supply only of the thermostat (adjustable type) suitable for upto 50 litres capacity of geysers.

22

-

-

... More
Supplying and fixing in replacement of geyser plate assembly suitable for 25 to 50 litres capacity geysers, of brass with inlet, outlet pipe, drain plug, thermostat chamber fixing heating element gasket nut, bolt etc are fixing the assembly to make it functional complete all as specified and as directed.

12

-

-

... More
Supply and fix in repair of flexible PVC pipe connection, nylon thread reinforced 15 mm dia, 450 mm long with brass union at both ends for 15 mm dia pipe complete all as specified and as directed.

38

-

-

... More
Supply and replacement of fusable plug complete all as directed

6

-

-

... More
Supply only gasket of thickness 5 mm for geyser assembly of 08 holes/09 holes complete all as specified & directed..

10

-

-

... More
S&F in repair indicating lamp for geyser rectangular type complete all as specified & directed.

12

-

-

... More
S&F in repair indicating lamp for geyser round type complete all as specified & directed.

24

-

-

... More
S&F non return valve for geyser all as directed.

4

-

-

... More
M & L for preparation of body of geyser for painting complete outer surface of any size/capacity with one coat of synthetic enameled paint complete all as specified & directed.

3

-

-

... More
Dismantling/taking out the geyser assembly & copper tank and making soldering & brazing of tank and fixing the same in the geyser of any cap.

3

-

-

... More
Water Cooler:- Comprehensive maintenance of water cooler various capacity including performing following tasks at different locations at AF Stn Dehradun :- (a) Inspection, dismantling front and rear shutters disconnecting electric and water connection. (b) Cleaning thoroughly the body of water cooler including cleaning of cold water tank with bleaching powder solution (c) Servicing of cooling fan by greasing to bearing, oiling to bushes after opening the motor. (d) Checking/rectifying the connection and working of thermostat relays, condenser, evaporator, capacities, switches, electrical connection, float valve, compressor earth connection including replacement of defective wire sleeves etc. (e) Replacement of PVC drain pipe from water cooler tray to neared drain. (f) Reconnecting power and water lines and testing to make it functional complete all as specified and as directed. (Note : Gas charging shall be measured and paid for separately)

4

-

-

... More
Gas charging the water cooler with gas F-22 capacity 40/80/60/150 litres capacity including making necessary connection, testing etc to make it functional complete all as specified and as directed.

4

-

-

... More
Supply and replacement of starting relay for water cooler any cap to make functional complete.

4

-

-

... More
Supply only of running capacitor 60/80 MFD for water cooler complete all as specified and as directed.

3

-

-

... More
S&F in replacement sealed compressor unit for 40 Ltrs cap single phase, 230 V and for water cooler, welding/brazing of gas pipe line, vaccume/ pressure leakage testing etc,Supply and charging of refrigerant gas of adequate quantity complete and testing incl taking down the old U/S sealed unit compessor all as specified and & directed.

1

-

-

... More
Supply and fix Gun metal gate valve with iron wheel head screwed both ends suitable for GI pipe of size 15mm dia bore all as specified & directed by Engineer-in-Charge

2

-

-

... More
Supply and fix stop valve with crutch or butterfly handle screwed down screwed both ends suitable for GI pipe of size 15mm dia bore all as specified & directed by Engineer-in-Charge

2

-

-

... More
REFRIGERATOR/Deep Freezer:- Comprehensive maintenance of refrigerator/Deep Freezer of any capacity make etc by performing the following tasks :- (a) Cleaning the refrigerator from inside with bleaching powder solution including cleaning the attached trays. (b) Cleaning the complete body thoroughly checking relay and rectifying the functioning of relays, compressor, thermostat electrical connection and condenser pipe including, checking and tighten of all bolt and clamp. Note : Supplying and replacement of parts shall be measured and paid separately.

5

-

-

... More
Supply & Fix of starting relay suitable for refrigerator of any capacity complete all as specified and as directed. MAKE : USHA, ASIAN, RENUTRAL, INDFOSS.

2

-

-

... More
Supply & Fix only of thermostatic switch with defrosting arrangement suitable for refrigerator of any capacity make and size all as specified and as directed.

2

-

-

... More
S&F in Replacement of electronic chip(PCB) including defrost timer,biometal for refrigerator of capacity 165 to 315 ltrs of LG/Samsung.

3

-

-

... More
M&L for Gas charging of refrigeratorof any capacity including making necessary connection, testing complete all as specified and as directed.

2

-

-

... More
S&F in replacement sealed compressor unit for Refrigerator/Deep freezer single phase, 230 V and welding/brazing of gas pipe line, vaccume/ pressure leakage testing etc,Supply and charging of refrigerant gas of adequate quantity complete and testing incl taking down the old U/S sealed unit compessor all as specified and & directed.

1

-

-

... More
Dismantling the voltage stabilizer 230/250 Volts 0.5 KVA and replace the unserviceable parts and reassembling the same after necessary repair & testing & commissioning the repaired stab in presence of Engr-in-charge complete all as specified & directed. (Note : Cost of UNSV parts deemed to be included in the quoted rates)

1

-

-

... More
All as per item No 198 here in before but 1.0 KVA cap.

2

-

-

... More
All as per item No 198 here in before but 2.0 KVA cap.

4

-

-

... More
All as per item No 198 here in before but 4/5.0 KVA cap.

42

-

-

... More
Desert cooler:- Comprehensive maintenance of desert cooler of any type and any make, fixed at different location at 1 AFSB Dehradun including taking down, cleaning gall dirt, dust, oiling of motor and pump, checking of parts, including replacement of nuts bolts, screw etc and preparation of the desert cooler body and tank by scrubbing the old paint and spray painting with two coat of synthetic enamel paint and spray painting with two coats of synthetic enamel paint complete all as specified and as directed Note : Supply and replacement of parts shall be measured and paid separately.

12

-

-

... More
Supply only of show grill of any size make and capacity of desert cooler of PVC of make as approved by GE.

10

-

-

... More
Supply only of wood wool pads of best quality as approved with and including wire mesh jalli for desert cooler of any size make and capacity all as specified and as directed.

20

-

-

... More
Supply and fixing in replacement of PVC elbows of suitable size all as specified and as directed.

10

-

-

... More
Supply and fixing in replacement of PVC pipe of superior quality 15 mm dia suitable for desert cooler all as specified and as directed.

20

-

-

... More
Supply and fixing in replacement of fan motor for desert cooler complete with blade, locknut, with all accessories 220/250 Volt of all as specified and as directed.

8

-

-

... More
Supply and fixing in replacement of desert cooler pump motor 230/250 Volt, 50 C/S complete with mounting accessories all as specified and as directed.

8

-

-

... More
Supply and fixing in replacement of indicating lamp for motor and pump including holder all as specified and as directed.

10

-

-

... More
Supply and fixing in replacement of plug top 5 amp 3 pin suitable for desert cooler all as specified and as directed.

2

-

-

... More
Supply and fixing in replacement of fan mounting bracket set as required for desert cooler all as specified and as directed

5

-

-

... More
Material and labour for disconnection of electric supply and water pipe line connections and taking out all type of clamp, nut bolt or connected fixing accessories from the existing position of each solar plate from solar heating collector plate system and removing all fixing accessories like aluminum side frame cladding ,heating top glass with rubber packing materials , copper fins with tubing plates jal assembly for the proposed of cleaning in side / removing blockage / depositing the scale ,sult, sludge, dirt etc particle material from in side of copper tubes jal assembly including cleaning ,checking, serviving , tighting , adjusting and also calibration and descaling through chemical acid solution method / manually mechanically system for making of nos of hole on each blockage copper tube assembly through suitable size of drilling rod with cleaning of wire brush in each copper tubing system and their after duly fill up the all nos of making hole work in copper tubes through hot & cold welding / brazing (gas or electric welding) work system and applying two coats of black bituminous paint over on distrubed place of copper fin and tubing jal system and after circulation of chemical acid solution through proper pressure washing pump in complete entire system and also rectification the leakage problem of entire tube system complete and after repair reaasembly and proper filling the all replacement item like insulation wool and aluminium foiling Glass work in side and around the collector plate system and replacement of defected nut, bolt & washer and fixing on same position and testing on system complete. NOTE APPLICABLE TO SERIAL ITEM 212: (i) Spare parts will be measured and paid separately under respective items of BoQ. (ii) Descaling, driiling ,Servicing, adjusting etc and testing run work will be carried out by well qualified techanician having good experience in the about repairing field of solar water heating system .

10

-

-

... More
Taking down old unserviceable digital timer and Supply and fix in repair digital 2 ACl timer switch, installing, testing and comissioning complette all as specified and directed.

1

-

-

... More
Taking down old unserviceable ball valve and supply and fix in replacement Ball brass valve, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule 20mm bore, ISI marked, IN REPLACEMENT complete all as specified.

4

-

-

... More
S&F u/s Aluminium foil rapping work in side of solar heating collector each panel plate system as per existing size and type including providing of adaptor solution material including taking down existing broken/defected aluminium foil IN REPLACEMENT complete .

2

-

-

... More
S&F u/s Insulation material suitable for filling of inside of solar heating collector panel plate system and solar tank ,and it connecting hot pipe lines system proposed including taking down existing insulation material IN REPLACEMENT complete.

1

-

-

... More
S&F u/s MS flanges fitted GI nipple of size 20 mm dia up to 4 inch long as per existing size and type IN REPLACEMENT complete .

1

-

-

... More
S&F u/s Rubber hose pipes of size 20 mm dia ,150 mm long with adaptor clamp as per existing size and type IN REPLACEMENT complete .

2

-

-

... More
Supply and Fix of heating element ISI marked of rating 2 KW suitable for existing solar water heater 500 ltrs capacity including testing complete all as specified and as directed.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.