Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Nov 2024
Closing Date21 Dec 2024
Tender Amount₹ 45,00,000
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_685552_1Bid Award Id
ViewTender No
8000-2196/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Removing surplus excavated material not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
109
-
-
... More
M & L for drilling suitable dia horizontal bore holes for insertion / laying of 50 to 150 mm bore GI/HDPE tubing of any description below/under road surface/floors etc with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing streta after laying pipes complete all as specified and directed.
50
-
-
... More
Supply and laying in replacement of brick, double walled corrugated (DWC) HDPE duct pipe in 6 mtr length conforming to IS 16205 Pt -24 of approved color complete with fittings for cable protection of size 63 mm outer dia and 50 mm inner dia complete all as specified and directed.
1440
-
-
... More
All as per item No- 6 here in above but 75mm outer dia and 63 mm inner dia
990
-
-
... More
All as per item No- 6 here in above but 90mm outer dia and 75 mm inner dia
990
-
-
... More
All as per item No- 6 here in above but 50mm outer dia and 38 mm inner dia
2460
-
-
... More
Supply and Laying including testing in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 150 Sqmm 3.5 core , including taking out old unserviceable LT UG cables of existing size from trenches, poles/walls and floor for removing of fault etc complete all as specified and directed.
500
-
-
... More
All as per item No- 10 here in above but 120 Sqmm 3.5 Core
500
-
-
... More
All as per item No- 10 here in above but 95 Sqmm 3.5 Core
500
-
-
... More
All as per item No- 10 here in above but 70 Sqmm 3.5 Core
500
-
-
... More
All as per item No- 10 here in above but 25 Sqmm 4 Core
1500
-
-
... More
All as per item No- 10 here in above but 16 Sqmm 4 Core
1600
-
-
... More
All as per item No- 10 here in above but 10 Sqmm 2 Core
1200
-
-
... More
Supply and fixing in replacement thermoplastic polystyrene /polycarbonate enclosure bus bar chamber of out side dimension 300X200X105 mm, shock proof, vermin proof and dust proof complete with 04 Nos with colour coded heat shrinkable sleeves and shall be mounted on F class insulators of capacity 100 amps with 01 No 20Amp SPN MCB including 02 Nos non metalic clamps and GI nut bolts and washers of suitable size and fixed on pole/wall including taking down old unsv complete all as specified and directed.
60
-
-
... More
S&F in replacement 1100 volts grade heavy duty PVC insulated aluminium conductor, bedded unarmoured cable of size 10 Sqmm 2 core fixed on wall/floor/poles complete all as specified and directed.
300
-
-
... More
S&F in replacement 1100 volts grade heavy duty PVC insulated aluminium conductor, bedded unarmoured cable of size 4 Sqmm 2 core fixed on wall/floor/poles complete all as specified and directed .
500
-
-
... More
Taking down existing old unserviceable LT Panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board, 415 Volts, 3 Phase & 4wire system, cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley protected with bakelite sheet between bus bar & cable alley with front side shutters with locking arrangement, including TPN Aluminium bus bar insulated with colour coaded heat shrinkable sleeve of rating not less then 1.5 times the rated capacity of the incomer ACB/MCCB and bus bar chamber covered both side using bakelite sheet partition and wire mesh to the back side of cable alley for the protection purpose . All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test at 65 KA, should be submitted by the contractor before executing the job. The TPN bus bar shall be mounted on F class insulators with intervals not more then 500 mm. All interconnections between the main bus bar as well as incoming/outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less then 1.5 times rated capacity of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 2.5 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm properly welded with 45 CM long 04 legs of angle iron 50x50x6 mm using 3 mm thick CRCA sheet corners to all legs and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of Aluminum lugs and suitable size of chrome plated brass double compression glands provided for incoming and out-going cables comprising the following :- Make of ACB/ MCCB/MCB/Change over switch: L&T/ABB/LEGRAND/SCHNIEDER/SIEMENS
6
-
-
... More
INCOMING MCCB
a) 400 Amp 4 pole MCCB 50 KA breaking capacity with adjustable thermal magnetic setting with earth fault protection and rotary handle Ics= 100% Icu-01 Nos. OUTGOING MCCB
a) 160 Amp 4 pole MCCB 25 KA breaking capacity with adjustable thermal magnetic setting Ics= 100% Icu - 01 Nos. c) 100 Amp 4 pole MCCB 16 KA breaking capacity with adjustable thermal magnetic setting Ics= 100% Icu - 04 Nos. d) Space for spare MCCB - 01 No.
Metering:
a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos
b) 0-500 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 No..
c) LED Indicating lamps RYB set of three -01 Sets
Note: (a) Cable entry should be incoming/ out going from separate cable gallery.
(b) All incoming/outgoing MCCBs shall be provided with suitable size of copper connection plates.
(c) All incoming/outgoing MCCBs shall be provided with suitable spreader links – 04 Nos.
(d) Provision of gland hole, brass glands and heat shrinkable end joints of all incoming and out going cables all as directed.
(e) All incoming/outgoing MCCBs should be marking label/end plate/end clams/ suitable size of terminal block stud/screw less type etc.
(f) Main bus bar/ link bus bar should be full covered including back side
-
-
-
... More
Supply, installing, erecting, commissioning and testing new factory made Bus Bar panel board cubical out door type of size 1.00 MtrX 0.750mtrX0.600mtr for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 60 cm legs & bottom channel of size 75 x 40 mm for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating 400A, 4Pole The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators complete all as specified and directed.
Note : Bus bar should be fixed on PCC and its rate included in quoted rate.
5
-
-
... More
Supply, installing, erecting, commissioning and testing new factory made Bus Bar panel board cubical out door type of size 0.750 MtrX 0.600mtrX0.500mtr for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 60 cm legs & bottom channel of size 75 x 40 mm for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating 250A, 4Pole The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators complete all as specified and directed. Note : Bus bar should be fixed on PCC and its rate included in quoted rate.
4
-
-
... More
M&L for replacement of existing old unsv earthing with steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground to a depth not less than 3.25 mtr deep below normal ground level with top edge of the earth plate not less than 2.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I complete all as specified and directed.
12
-
-
... More
Clearing of bushes/small plants upto root level around and surroundings areas E/M installations (i.e. Two Pole/ Four structures, outdoor-substation yards & other Misc E/M installations etc.) soft and loose soil including surface dressing n.exc 15 cm deep and removing debris to a distance not exc 50m complete all as specified and directed.
6000
-
-
... More
Trimming up of tree branches upto 3 mtr all around LT overhead lines, removing cut branches from site complete all as specified and directed.
Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 3 mtr all around the line. (ii) Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department.
100
-
-
... More
M & L for disconnecting of burnt/damaged cables from panels/junction boxes etc , cutting out the burnt out ends , making new end joints by supply and fixing new aluminium lugs/insulation tapes etc and reconnecting using new nuts/bolts/washer etc and restoring three phase and neutral in the junction box for the 10 to 240 sqmm 2/3.5/4 core size of LT underground armoured cables complete all as specified and directed. Note - Earth work required for extending the incoming/outgoing cable in junction box/panel board etc shall be deemed to be included in the unit rate quoted.
20
-
-
... More
Material and labour for PCC (1:3:6) type C1 (using 20mm graded aggregate) in coping/pedestal of poles/foundation including necessary form work and finishing surfaces fair and even using extra cement complete all as specified and directed.
3
-
-
... More
Supply only Brown Bamboo Ladder of height/length 40 Fit, the steps are spaced 30cm to 34cm complete all as specified and directed.
2
-
-
... More
Supply only Brown Bamboo Ladder of height/length 30 Fit, the steps are spaced 30cm to 34cm complete all as specified and directed.
2
-
-