Madhyanchal Vidyut Vitran Nigam Limited Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender
Eprocure
Opening Date28 Sep 2024
Closing Date9 Oct 2024
Tender Amount₹ 1,16,49,000
Costs
EMD
₹ 1,17,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MVVNL_959817_1Bid Award Id
ViewTender No
22/SE/EWC/AYO/2024-25Tender Authority
Madhyanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://www.mvvnl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M.S. Top Channel 125x65 mm 3200 mm
88
-
-
... More
M.S. Angle 65x65x6 mm Bracing, 4300 mm
74
-
-
... More
MS Angle for guarding 65x65x6 mm, 3500 mm long
812
-
-
... More
GI Wire 8 SWG
145.2
-
-
... More
GI Wire 6 SWG
1436.8
-
-
... More
33 KV Disc Insulator B & S Type polymer
201
-
-
... More
V Type channel cross arm
238
-
-
... More
33 KV Pin Insulator polymer type
915
-
-
... More
Stay Wire 7/8 SWG
2112
-
-
... More
Cost of ACSR Dog Conductor
43.79
-
-
... More
Cost of 33 KV 3x300 sq mm XLPE Cable
6340
-
-
... More
33 KV Outdoor jointing Kit for 3x300 sq mm XLPE Cable
76
-
-
... More
33 KV Straight through jointing Kit for 3x300 sq mm XLPE Cable
2
-
-
... More
M.S. Channel 125x65 (for Structures )
103
-
-
... More
M.S. Angle 75x75x6 (for Structures )
20
-
-
... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Single Pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 1 no Channel Cross Arm, 3 No. polymer Pin insulator as per norms. (Contractor shall provide , necessary clamps, F-brackets, Nut - Bolts, Washers etc.)
202
-
-
... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Sectional Double pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 1 No Top channel of 125x65x6 mm size 3200 mm , Bracing angle 1 set.,33 Kv , Disc insulator 6 No. and 3 No. Pin insulator as per norms. (Contractor shall provide , E- Bracket , necessary clamps, Disc Fitting, Nut - Bolts etc.)
14
-
-
... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Sectional Double pole for 33 KV Line on 11.0 Mtr STP Pole with fitting of necessary clamp & other acessories like 1 No Top channel of 125x65x6 mm size 3200 mm, 6 No. Disc. Fitting , Bracing angle 1 set., 33 kv Disc insulator 6 No. and 3 No. Pin insulator as per norms. (Contractor shall provide , E- Bracket, necessary clamps, Disc Fitting, Nut - Bolts etc.)
4
-
-
... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Single Pole for 33 KV Line on 11 Mtr ST Pole with fitting of necessary clamp & other acessories like 1 No. Channel Cross Arm,3 No. polymer Pin insulator as per norms. (Contractor shall provide necessary clamps, F-brackets/top cleet, Nut - Bolts, Washers etc.)
36
-
-
... More
Erection of single stud pole support on PCC Pole 9.0 Mtr long with fixing of necessary clamps and other accessories required for erection. (Contractor shall provide necessary clamps, Nut - Bolts, Washers etc)
8
-
-
... More
Erection of single stud pole support on STP Pole 11 Mtr long with fixing of necessary clamps and other accessories required for erection. (Contractor shall provide necessary clamps, Nut - Bolts, Washers etc)
3
-
-
... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Dead end Double pole for 33 KV Line on 11.0 Mtr STP Pole with fitting of necessary clamp & other acessories like 1 No Top channel of 125x65x6 mm size 3200 mm . , Bracing angle 1 set., 03 No disc insulator etc as per norms. (Contractor shall provide all necessary clamps, Nut - Bolts & washer and E-bracket, Disc fitting if required etc)
3
-
-
... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Dead end Double pole for 33 KV Line on 9.0 Mtr Pcc Pole with fitting of necessary clamp & other acessories like 3 No Top channel of 125x65x6 mm size 3200 mm . , Bracing angle 1 set. , 03 No disc insulator etc as per norms. (Contractor shall provide all necessary clamps, Nut - Bolts&washer and E-bracket, Disc fitting if required etc)
8
-
-
... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Tri pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 3 No Top channel of 125x65x6 mm size 3200 mm ,Disc insulator 6 No, 6 Polymer Pin insulator, Bracing angle 3 set, as per norms. (Contractor shall provide , necessary clamps, Disc fitting , Nut - Bolts etc.)
1
-
-
... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Tri pole for 33 KV Line on 11.0 Mtr STP Pole with fitting of necessary clamp & other acessories like 3 No Top channel of 125x65x6 mm size 3200 mm ,Disc insulator 6 No, 6 Polymer Pin insulator, Bracing angle 3 set, as per norms. (Contractor shall provide , necessary clamps, disc fitting, Nut - Bolts etc.)
1
-
-
... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Four pole for 33 KV Line on 11 Mtr ST Pole with fitting of necessary clamp & other acessories like 4 No. Top channel of 125x65x6 mm size 3200 mm, Bracing angle 4 set, 6 No. 33 kv disc insulator B &S , Pin insulator 09 No. as per norms. (Contractor shall provide , E- Bracket, necessary clamps, Disc Fitting, F-clamp , Nut - Bolts washers etc. )
3
-
-
... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Four pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 4 No. Top channel of 125x65x6 mm size 3200 mm, Disc Fitting 6 No. Bracing angle 4 set, 6 No. 33 kv disc insulator B &S , Pin insulator 09 No. as per norms. (Contractor shall provide , E- Bracket ., necessary clamps, Disc Fitting, F-clamp , Nut - Bolts washers etc. )
5
-
-
... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Expoure Double pole for 33 KV Line on 11.0 Mtr STP Pole with fitting of necessary clamp & other acessories like 3 No Top channel of 125x65x6 mm size 3200 mm . , Bracing angle 1 set., and 9 No. Pin insulator as per norms. (Contractor shall provide all necessary clamps, Nut - Bolts&washer and e-bracket if required etc)
4
-
-
... More
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Expoure Double pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 3 No Top channel of 125x65x6 mm size 3200 mm . , Bracing angle 1 set., and 9 No. Pin insulator as per norms. (Contractor shall provide all necessary clamps, Nut - Bolts&washer and e-bracket if required etc)
3
-
-
... More
Cradle Guarding of 33 KV line at road crossing/ 11 KV line crossing, canal/telephone line crossing by fixing Guarding Angle 65x65x6 mm, 3500 mm at double pole and 2600 mm long at single pole by stringing and sagging of 3 No. G.I.wire with lacing and tightening with mounting. (Contractor shall provide Necessary clamps for fitting of guarding angle and 6 No. Eye hook&bolt 12x110 mm etc.)
20
-
-
... More
Angle for Cross arm Support at Angle Location 65x65x6 mm 1600 mm long with clamps and nut & bolt. (All materials will be supplied by the contractor)
10
-
-
... More
Cable stand Structure
Fabrication & erection of 33 KV Cable Stand made of 02 No. M.S chanel 125x65x6 mm 3 Mtr. Jointed to each other by M.S Channel horizontally and also jointed to each other by means of 05 No. M.S Strip (m.s flat) 50x6 mm of size 200 mm long each by welding at actual distance interval as per norms. And grouting in block of 300x300x700 completely providing 02 no. cable clamps also and eathing by G.I strip 50x6 mm size with the earth mat of switchyard both side of legs and provideing clamps , post/ pin insulator for holding cable. (All the materials will be arranged by the contractor such that clamps nut bolts and civil materials except M.S channel.)
1
-
-
... More
Nozeling and grouting of stay at sectional pole and extra stay sets at angle locations (All the civil material and 33 KV G.I stay set 20x1800 mm, stay clamp will be arranged by the contractor except stay wire)
20
-
-
... More
Stringing, sagging, binding and Jumpering of ACSR Dog conductor. 3 Phase of 33 KV Line including fixing, mounting of P.G.clamp suitable for Dog Conductor at sectional point. (Contractor shall provide necessary PG clamps etc)
13.9
-
-
... More
Laying & Dressing of 3x300 sq. mm XLPE Cable underground Double Circuit.
Laying of double circuit 3x300 sq .mm XLPE Cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required materials, as 1st class Bricks, Stone slabs and fine sand. Providing 150 mm fine sand cusion beneath, and 150 mm sand cusion above the cable. The cable shall be duly protected by Bricks, sand and stone slab. The inter axial spacing between two cables should be in between 0.25 to 0.04 M. After laying the cable refilling and ramming of the left out soil,closing the trench and leveling.
2550
-
-
... More
Installation of Heat Shrinkable Type cable jointing kits of following types/sizes for 33 XLPE Cable.
1
-
-
... More
(a) Fixing of 33 KV 3x300 sq. mm Straight Through joints. (jointing kit supplied by dept.)
2
-
-
... More
(b) Fixing of 33 KV 3x300 sq. mm Outdoor End Terminations (jointing kit supplied by dept.)
76
-
-
... More
High Pressure testing to which 33 KV Line & cable to be stand for duration of 5 minutes after completion of Laying, Stringing, sagging, binding and Jumpering of ACSR Dog conductor. ( Testing equipment will be arranged by the contractor)
6
-
-
... More
Hoisting of 33 KV Cable on existing/erected support with provision of MS Pipe 150 mm dia 3 mtr long suitable for 3x300 sq mm cable fixing of proper support and its clamping, providing long barral lugs 6 nos and P.G. Clamps & "Y" shape jumpering properly and 02 nos. supporting angle 65X65X6, 2240 mm long and making connection including supply of jumpering cable ,mounting clamps as per RESSPO Norms. (All material will be supplied by the contractor like M.S Pipe , P.G. Clamps, Al. Lug And Supporting Angle 65X65X6, 2240 mm and jumpering cable suitable for 33 KV jumper).
74
-
-
... More
Grouting of following structure by digging of pit 1.5 Mtr/1.83 Mtr deep for 9.0 Mtr PCC / 11 Mtr STP respectively, placing stone pad at bottom 450x450 size foundation is provided with help of steel or wooden formers, groutung with 1:4:8 Ratio cement, sand & first class brick ballast 0.268/0.285 cu mtr for 9.0 mtr PCC Pole & 11 mtr STP, plinthing 0.3 Mtr above G/L and proper plastering.
1
-
-
... More
11 Mtr ST Poles
76
-
-
... More
9.0 Mtr PCC pole
283
-
-
... More
Supply and fixing of a stone pad of size 300x300x75 mm at PCC/STP Bottom of the pit ( Contractor shall provide all materials)
359
-
-
... More
Fabrication, Erection and grouting of route marker and marking 33 KV line by painting after grooving on the stone. (Contractor shall provide all materials)
52
-
-
... More
Providing of barbed wire
718
-
-
... More
Fixing of barbed wire on pole on STP/PCC pole
fixing of barbed wire on the pole above 2750 mm ground level. Barbed wire wrapped for a distance of 0.9 mtr. with a pitch of 13.mm at a height. (All materials supplied by the contractor)
359
-
-
... More
Fixing of Danger board .
Supply and fitting of Danger board of size 250x200x2 mm 3650 mm above ground level with the help of proper size of nuts, Bolts , washers and clamps as per Respo norms. RESPO Drawing No-55 (All materials supplied by the contractor)
359
-
-
... More
Fixing of Number plate .
Supply and fitting of Number plate of size 250x200x2 mm 3650 mm above ground level with the help of proper size of nuts, Bolts , washers and clamps as per Respo norms. RESPO Drawing No-55 (All materials supplied by the contractor)
359
-
-
... More
Earthing of Pole
Earthing of Pole STP/PCC by 6 SWG Wire by providing and fixing of 20 mm dia' earthing rod 2.550 Mtr. long as per norms complete in all respect. (Contractor shall provide all the material Like Earthing rod, Earthing clamps and nut & bolt etc.)
348
-
-
... More
Nozeling and grouting of stay (All the civil material and 33 kv G.I stay set 20x1800 , stay clamp will be arranged by the contractor except stay wire)
244
-
-
... More
Petrolling in feet from starting to end and removal/lopping and chopping of tree branches which are lying in routre of 33 KV overhead line.
13
-
-
... More
Providing of HDPE 6"Dia Pipe PN-6 Specification
100
-
-
... More
Laying of cable & HDPE Pipe
Laying of Single circuit 33 KV 3x300 Sq mm XLPE cable and HDPE Pipe by drilling method below NHAI road crossing. The cable be laid at the depth of 3 mtr from the under surface in HDPE pipe (200 mm. dia.) casing.
100
-
-
... More
NOC will be granted from Central/ state Electrical safety department.( Final settlement of the payment will be done after providing receipt, agreement and permission paper).
1
-
-
... More
restoring the road as it is before after completion of work
34
-
-
... More
Permission of NHAI/PWD etc. for road crossing.( Final settlement of the payment will be done after providing receipt, agreement and permission paper)
1
-
-
... More
permission of cutting and chopping of tree from forest deppt. ( Final settlement of the payment will be done after providing receipt, agreement and permission paper)
1
-
-
... More
Carraige and erection of A-type tower (fully submerged) All materials will be provided by the contractor with stringing of ACSR Dog conductor
1
-
-
... More
33 KV Disc Insulator B & S Type 70 KN porcelain
24
-
-
... More
33 KV Disc fitting suitable B & S type porcelain Disc 70 KN
12
-
-
... More
Galv. Stub
0.36
-
-
... More
Galv. Towerpart
5.61
-
-
... More
Nut Bolt & Accessories
0.34
-
-
... More
Stub Setting
2
-
-
... More
Excavation ( for-FS)
174.96
-
-
... More
Cost of Concreting for all types of tower foundation including cost of cement,dewatering,shoring and shuttering, forming, curing but excluding cost of reinforcemnt (for-FS)
16.99
-
-
... More
Steel Rainforcement
134
-
-
... More
Erection of tower with fitting
5.95
-
-
... More
Tack welding
400
-
-
... More
Pipe Type Earthing
2
-
-
... More
Number Plate
2
-
-
... More
Danger Plate
2
-
-
... More
Phase Plate in set of RYB
2
-
-
... More
Bird guard
6
-
-
... More
Hoisting of 33 KV Cable on erected support on 33 kv cable stand by using clamp with nut bolt and suitble size of G.I. pipe. (All material will be supplied by the contractor like G.I Pipe ,P.G. Clamps, Al. Lug And and jumpering cable suitable for 33 KV jumper).
2
-
-
... More
Painting of poles Painting of poles with one coat of red oxide, two coats of enamel paint ISI mark. (All required material will be supplied by the contractor)