Madan Mohan Malaviya University Of Technology Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Madan Mohan Malaviya University Of Technology - MMMUT Tender
Eprocure
Opening Date29 Oct 2021
Closing Date22 Nov 2021
Tender Amount₹ 99,92,000
Costs
EMD
Refer DocumentsDocument Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_MMMUL_637874_1Bid Award Id
ViewTender No
MUT/NIRMAN/tender/06/2021Tender Authority
Madan Mohan Malaviya University Of Technology ViewPurchaser Address
-Website
http://http://www.mmmut.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
P/L Brick coba 12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gaps of 15 mm to each other,over 20 mm thick base cement mortar 1:4 with cement & C. sand mixed with water proofing compound spreding cement slurry mixed with aerelic cement concrete water proofing compound filled gaps of coba & top of coba 1:4 cement & C. sand mortar finished smooth & top mashed false square 30x30 cm and side wall parrapet shall be mono lythic plaster wall up to 30 cm hibher and junction & corner shall be round by brick ballast cement & c. sand masonary coba with top finished plaster mixed with acetic water proofing compound @ 2.00% by weight & including S/o all material,labour & T/P etc. complete as per (SI-Ch-11 New )
1902.22
-
1100
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 cement,C. sand & 20 mm gauge stone agregates over PVC sheet 1mx1mx400 micron finished with 12 mm thick plaster in 1:3 with cement & C. sand and a floatong coat of neat cement,rounding the edges and making & finishing the outlet complete as per (DSR-12.22)
55
-
233.75
Providing Gola 75x75 mm in cement concrete in 1:2:4 with cement,C. sand & 10 mm & down gauge stone agregates including finishing cement mortar in 1:3 with cement & F. sand as per standard design complete as per (DSR-12.21.1)
732.99
-
228.14
P/F on wall face 110 mm dia unplasticised Rigid PVC rain water pipes complete as per (DSR-12.41.2)
196
-
280.35
P/F on wall face 110 mm dia unplasticised-PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes complete as per (DSR-12.42)
-
-
-
(i) Bends 110 mm dia (DSR-12.42.5.2)
30
-
115.47
(ii) Plain Shoe 110 mm dia (DSR-12.42.6.2)
30
-
101.66
(iii) Coupler 110 mm dia (DSR-12.42.1.2)
30
-
105.17
P/F unplasticised -PVC pipe clips of approved design to unplasticised PVC rain water pipes by means 50x50x50 mm hard wood plugs,screwed with M.s screws of required length including cutting brick work & fixing in cement mortar in 1:4 with cement & C. sand & making good the wall etc. complete as per (DSR-12.43.2)
83
-
271.37
P/L Cement concrete in retaining walls, return walls, including attached pilasters, columns, piers, etc. with cement, C.sand & 3 graded stone aggregate 20mm nominal size in 1:1.5:3 complete as per (DSR-4.2.2)
12
-
8587.16
12 mm thick plaster in 1: 4 with cement & C.sand mortar (DSR-13.4.1)
628.48
-
269.4
12 mm thick plaster in 1:3 with cement & C.sand mortar (DSR-13.9.1)-(13.7.2-13.1.1)
626.36
-
280.66
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as perASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loadingrequirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -inCharge. (Material shall confirm to ASTM 6063) (DSR-5.44.1)
13.8
-
5085.57
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profileand flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). (DSR-5.46.1)
25.9
-
4755.94
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-InCharge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as perASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System.The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063) complete as per (DSR-5.45.1)
7.5
-
4239.77
Providing & Applying Fiber reinforced elastomeric liquid water proofing membrane with resilient acrylic polymer having Sun reflectivity index of 105 on top concret roof in three coats @ 10.76 Lit. /10 sqm . One coat of self primming elastomeric water proofing liquid (dilusion with water in the ratio of 3:1) and two coat of undilutaed elastomeric water proofing liquid (dry film thickness of complete application not less than 500 microns) complete as per (DSR-22.22A)
626.36
-
415.73
Removing dry or O.B.Distemper,water proofing cement paint & the like by scraping,sand papering & repairing the surface smooth including necessary repair to scratches etc. complete as per (DSR-13.91)
16052.32
-
18.28
Providing & laying 1.0 mm thick white cement based wall puty two coat complete as per (DSR-13.80)
7223.54
-
108.59
Finishing wall with Premium Acrylic Smooth exterior pint with silicon additives of required shade tow or more coat complete as per (DSR-13.47.1)
16052.32
-
142.35
S/F 1.50 Ton 3 star Split A.C. including all fitting & fixture as per direction Enginner- in -charge complete as per (MR)
40
-
49000
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements