Indian Oil Corporation Limited Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Indian Oil Corporation Limited - IOCL Tender
Software and IT Solutions
Eprocure
Opening Date18 Feb 2025
Closing Soon11 Mar 2025
Tender AmountRefer Documents
Costs
EMD
₹ 16,41,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Group A - Rate Contract For Design, Supply, Installation, Testing And Commissioning Of It Hardware And Rtus At Cgd Stations For A Period Of 3 Years
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PLHO_183818_1Tender No
PLCC/Rate Contract/TI/25010Tender Authority
Indian Oil Corporation Limited ViewPurchaser Address
-Website
http://https://www.iocl.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Special Instructions to the Bidders
Bidders_help_Document_for_Preferencial_ Bidding_20230207_v1
BOQ Items
... More
"Type-1A RTU for CGS stations c/w processor module, I/O modules, redundant min 4 port L2 ethernet switches, relay modules, power sup plies, dual redundant field interrogation power supply & DC-DC/ AC-DC converters, Data Panel, communication ports, serial & Ethernet interfaces, necessary operating & application s/w, all interconnecting cables, connectors, RTU cabinet etc. complete in all respect s as per I/O list & tender specifications etc. "
10
-
-
... More
"Type-2 RTU for CNG RO stations & LNG Hubs c/w processor module, I/O modules, relay modules, power supply, dual redundant field inte rrogation power supply & DC-DC/ AC-DC converters, communication ports, serial & Ethernet interfaces, necessary operating & applicati on s/w, all interconnecting cables, connectors, RTU cabinet etc. complete in all respects as per I/O list & tender specifications et c. "
703
-
-
... More
"Type-3 RTU for GOOV/GAV / DRS /MRS stations c/w processor module, I/O modules, relay modules, power supplies, dual redundant field interrogation power supply & DC-DC/ AC-DC converters, communication ports, serial interfaces, necessary operating & application s/w, all interconnecting cables, connectors, RTU cabinet in form of FLP JB , suitable for Hazardous Area Installation etc. complete in all respects as per I/O list & tender specifications etc. "
21
-
-
... More
Type-4 RTU for CGD Control Rooms for interfacing of all the RTUs under GA with the supplied RTU as Master c/w processor module, I/O modules, redundant min 6 port L2 ethernet switches, power supplies, Data Panel, DC-DC/ AC-DC converters communication ports, seria l & Ethernet interfaces, necessary operating & application s/w, all interconnecting cables, connectors, RTU cabinet/ kiosk etc. comp lete in all respects as per I/O list & tender specifications etc.
10
-
-
... More
Zener Barriers
-
-
-
... More
For AI
250
-
-
... More
For AO
50
-
-
... More
For Pulse
10
-
-
... More
Surge Protection Devices
-
-
-
... More
For RS 232/485 signals
2976
-
-
... More
1 Phase 2 wire (230 V/48VDC) applications
1468
-
-
... More
MODBUS GATEWAY
-
-
-
... More
Industrial Grade Ethernet to 4 port Serial Gateway/ MODBUS TCP to MODBUS RTU Converter with required connectors, cables, power suppl y etc. as per tender specifications
50
-
-
... More
SOFTWARE
-
-
-
... More
Programming / ladder logic / testing software for RTUs programming including one time license fee as per tender specifications.. (1 Set= 1 programming/ladder logic/ testing software per site)
20
-
-
... More
HMI Programming & Runtime Software of the HMI on the data panel as per tender specifications.
20
-
-
... More
IT Hardware
-
-
-
... More
HMI machines as per tender specifications , along with accessories and softwares as per scope of work and technical specifications.
10
-
-
... More
Supply of 23" Display Monitor as per tender specifications.
10
-
-
... More
Industrial Grade Programming Terminal (Laptop) for BV-RTUs: 10/100/1000 MBPS Ethernet card, rain, spill, dust and vibration resistan t, Li-ion battery, Power Adapter, necessary interfaces (serial & parallel), necessary operating & application s/w, diagnostic s/w, s /w for operating RTU, carrying case complete with all interconnecting cables, cords, connectors, USB to Serial (RS485) Converter & p eripherals etc. complete in all respects as per tender specifications.
20
-
-
... More
WAN Router (8 port) system with software, cables, connectors etc complete in all respects as per tender specifications (PLNET router )
20
-
-
... More
Firewall (Type-II) for Control System to ensure Control System security as per tender specifications complete with cables, connector s, software etc.as per specifications
10
-
-
... More
3G/4G/GSM routers for RTUs for communication of the RTUs over GPRS/3G/4G in case of failure of the OFC communication System. GSM rou ter should be complete with antenna, cable, connectors etc. and suitable for 2G / 3G / 4G data enabled SIM cards of major service p roviders like BSNL, Vodafone, Airtel, Reliance, Tata etc. as per tender specifications.
818
-
-
... More
LARGE SCREEN MIMICs
-
-
-
... More
LED Display Unit (50" & above) System with interface complete with all inter connecting cables, cords, connectors, peripherals, OEM' s make Mounting Kits etc complete in all respects as per the tender specifications & datasheet.
10
-
-
... More
Wireless Solution for RS 485 data transfer
-
-
-
... More
Wireless IO Module With RS-485 ports complete with power convertors, antenna, all inter connecting cables, cords, connectors, periph erals, OEM's make Mounting Kits etc complete in all respects as per the tender specifications & datasheet.
2109
-
-
... More
Wireless Gateway for interfacing the wireless IO module with RTU complete with power convertors, all inter connecting cables, cords , connectors, peripherals, OEM's make Mounting Kits etc complete in all respects as per the tender specifications & datasheet.
703
-
-
... More
Flame proof and weather proof junction boxes including supplyof EP/WP double compression cable glands, plugs for unused cable entrie s including EP/WP certificates as per the tender specifications for Wireless modules in hazardous areas.
2109
-
-
... More
RTU Card Wise Rates
-
-
-
... More
RTU Processor module as per the tender specifications & datasheet.
74
-
-
... More
RTU DI card as per the tender specifications & datasheet.
31
-
-
... More
RTU DO card as per the tender specifications & datasheet.
16
-
-
... More
RTU AI card as per the tender specifications & datasheet.
16
-
-
... More
RTU Processor Power supply as per the tender specifications & datasheet.
74
-
-
... More
RTU Communication card for third party interface as per the tender specifications & datasheet.
74
-
-
... More
RTU Analog Output card as per the tender specifications & datasheet.
6
-
-
... More
Services
-
-
-
... More
Erection, testing & commissioning of RTU and interfacing instruments and Modbus enabled IED like Dispenser, Compressor, Mass Flow M eters , UPS with RTU including supervision of termination of control cables and supervision for interfacing & integration of wirele ss devices / antennas / modem /gateways / hardware etc with RTU and with Centralized SCADA and GA Control Rooms and field instrument ation systems including supplied hardware/ software with station on remote& auto including development of control logics etc making all jobs complete as per drawings / specifications and acceptance of system by Owner. This include supply of all labour, consumables , tools, services rendered etc. The scope includes testing of Modbus data using Modbus Simulator ( including arranging necessary Sof tware and Hardware ) and establishing the availability of data at the RTU terminal and assisting owner in integration of the RTU dat a with owners extsing SCADA.
-
-
-
... More
At CGD Control Rooms for Type-4 RTUs
10
-
-
... More
At CGS for Type-1A RTUs
10
-
-
... More
AtCNG RO/ LNG locations and GOOV/GAV / DRS /MRS stations for Type-2 & 3 RTUs
724
-
-
... More
Composite
-
-
-
... More
INSTALLATION OF RTU/ KIOSK/ SERVER CABINET/ LED - Taking delivery, shifting the panels to installaion site and erection, installatio n of RTUsRTU/ KIOSK/ SERVER CABINET/ LED including steel structure/ fixtures aligning, levelling, grouting, inter-wiring outgoing, t ermination of field cables, earthing, testing, complete in all respects as per drawings, specifications and directions of the engine er in-charge/site engineer, including supply of suitable size non-flame proof cable glands for all incoming/outgoing cables and the cost of the materials, tools, labour, glanding, ferruling etc. complete in all respects.The indicated quantity is cumulative weight of panels.
744
-
-
... More
Installation of explosion proof / flame proof junction boxes for marshalling of control / signalling cables, terminating the cables at field and control panel end, mounting the junction boxes, connecting to earthing grid by supplying and installing all the require d materials such as supporting structure, painting, GI wire etc.(excluding supply of the Junction Boxes) complete in all respects a s per specifications, approved drawings and direction of EIC / Site Engineerincluding all labour, tools, materials, glanding, ferrul ing etc.complete in all respects.
2109
-
-
... More
ARC FOR 5 YEARs
-
-
-
... More
Manday charges for site visit for additional configuration/ Modification/ diagnosis/ rectification works at site for RTU panels and other contract items complete in all respects as per the directions of EIC.
1000
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%