Indian Institute Of Toxicology Research Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Indian Institute Of Toxicology Research - IITR Tender
Eprocure
Opening Date4 Oct 2019
Closing Date14 Oct 2019
Tender Amount₹ 18,72,000
Costs
EMD
₹ 37,450Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Sitc Of Fire Hydrant And Fire Alarm System
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_CSIR_33463_1Bid Award Id
ViewTender No
IITR/EME-17(14)/2019Tender Authority
Indian Institute Of Toxicology Research ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying & Fixing Single Headed Internal/ Extrnal Hydrant Valve with intantaneous stainless steel coupling of 63 mm. dia with cast iron wheel ISI marked, conforming to IS: 5290 (Type -A) with blank ABS cap & chain complete with all accessories etc. as required.
7
-
-
Supplying & Fixing 63 mm. dia,Stainless Steel Branch Pipe with 16/20 mm dia Stainless steel nozzle conforming to IS:903 suitable for instantananeous connection to hose pipe coupling .
12
-
-
Supply, installation, Testing & commissioning of 63 mm dia, 15 mtr. long RRL non-percolating FIRE hose with stainless steel male & female coupling (ISI marked) duly binded with G.I. wire rivets conforming to IS 636 Type A as required.
24
-
-
Supplying, Laying, Testing & Commissioning of Ring Mains for external hydrant with C-class heavy duty black MS pipe Conforming to IS 1239 complete with all fitting and accessories like elbows , tees, flanges, taper, reducers , nuts, neoprene gasket & washer including cutting, welding etc.,excavation of trench in ground & providing cement, concrete blocks as supports, anti corrossive treatment with pypekote cloth /coaltar/asphalt tape 4 mm thick as per IS 10221 and laying the pipe so that the top of the pipe is at the depth of 1 Mtr below ground level, refilling & ramming ,watering the trench with soil in layers not exeeting 20 cm in depth etc.complete as required of following sizes.
-
-
-
(a) 100 mm dia
85
-
-
Providing, Laying, Testing & Commissioning of C- class heavy duty MS black pipe on surface Conforming to IS 1239 for riser complete with all fittings and accessorries like elbows,tees, flanges ,tapers, reducers, nuts, brackets/clamps,neoprene gasket and washers including cutting & welding etc , fixing the pipe on the Wall / Ceiling with suitable clamps and painted with two or more coats of synthatic enamal paint after primer coat of required shade, cutting hole & chase in brick wall / RCC slab & making good the same etc. complete as required.
-
-
-
(a) 100 mm dia.
39
-
-
(b) 80 mm dia.
17
-
-
Supplying, Fixing, Testing & Commissioning of butterfly valve PN 1.6 flanged at both ends, with non rising spindle, bronze / G.M. seat ISI mark complete with neoprene gaskets, nuts, bolt & washer etc. conforming to IS 13095 as required of following sizes.
-
-
-
(a) 100 mm dia
2
-
-
Providing, Installation, Testing & commissioning of dual plate double flange cast iron Non Return Valve PN 1.6 of following size conforming torelevant IS complete with neoprene gaskets,GI bolts, nuts , washer, etc complete as required.
-
-
-
(i) 100 mm dia
2
-
-
(ii) 80 mm dia
1
-
-
Supplying, Installation, Testing & Commissioning of 100 mm dia bourden type, stainless steel Pressure gauge including brass isolation valve & siphon pipe having calibration of 0-16 Kg / sq. cm.
1
-
-
Supplying and fixing of air vessel made of 200 mm dia, 8 mm thick MS sheet, 1200 mm. in height with air release valve on top and flanged connection riser, drain arrangement with 25 mm dia valve, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade complete as required.
1
-
-
Supplying & fixing First Aid Hose Reel, wall mounting swinging type complete with drum & bracket of MS construction,spray painted in Post Office Red, conforming to IS 884 / 1985 with upto date amendments, complete with the following as required.
4
-
-
(a) 30 Meter long 20 mm dia water hose Thermoplastic (Textile Reinforced) Type-2 as per IS :12585
-
-
-
(b) 25mm dia gun metal ball valve & nozzle.
-
-
-
(c)Drum & Bracket for fixing the equipment on wall.
-
-
-
(d) Connection from riser with 40 mm. dia MS pipe.
-
-
-
Supply,installation,testing and commissioning of fire brigade inlet 2 way with 63 mm dia instanteneous inlet along with 100 mm dia butterfly valve, NRV and MS sheet enclosure fabricated from 16 gauge MS Sheet of fully welded construction with hinged double front shutters glazed with 4 mm thick glass with locking arrangement duly powder painted with synthatic enamel paint with post office red colour externally & white internally . The enclosure shall be mounted on raised brick plateform complete with plaster and all other necessary supports etc as required.
1
-
-
Total: Sub Head-I (Fire Hydrant System)
-
-
-
Sub Head-II: Fire Alarm System
-
-
-
Supply,installation,testing and commissioning of photo electric type optical smoke detectors with base etc complete in all respect as required for conventional type automatic fire alarm system.
120
-
-
Supply,installation,testing and commissioning of fixed temperature cum rate of rise heat detectors including base with thermistor as temperature sensing element as per detailed specifications complete in all respect as required for conventional fire alarm system.
8
-
-
Supply,installation,testing and commissioning of dust tight push button MS body manual call boxes to initiate audio/visual alarm with breakable glass in the front complete with small steel hammer attached with steel chain in surface/recess including chase cutting of wall and making good, making connection with wires etc complete work in all respect as required.
8
-
-
Supply,installation,testing and commissioning of fire alarm electronic hooter/sounder (5W) alongwith line matching transformer for PA system housed in sheet steel housing in wall or ceiling including chase cutting and making good complete with connection with wires, painting etc complete work as required.
9
-
-
Supply,installation,testing and commissioning of response indicator housed in dust tight sheet steel housing in wall /partitions,surface/recess including chase cutting and making good, making connection with wires painting etc complete work as required.
30
-
-
Supply,installation,testing and commissioning of wall mount six zone conventional micro processor based Automatic Fire alarm main control and indicating panel having six zones detection circuit to monitor all local/zonal control panels on each floor complete with indicators with SMPS and battery polarity & deep discharge protection, battery charger,battery box with required nos. of 24V sealed lead acid battery suitable for operating the system for 30 minutes in emergency condition .Each zone shuld have provision of activation of hooters with PA system including electrical wiring etc complete work in all respect as required.
1
-
-
Supply, installation,testing and commissioning of four zone capacity local automatic fire control panel complete with connections etc complete in all respects as required.
4
-
-
Supply and laying of pvc insulated armoured copper conductor following size cable on surface complete with connections etc complete as required.
-
-
-
(i) 2x1.5 sq mm
800
-
-
(ii) 3x1.5 sq mm
700
-
-
Supply and fixing of self glow type Exit/Fire Exit signage in dual language of Hindi and English complete work as required.
10
-
-
Supply of new ABC powder type (stored pressure) 6 kg capacity fire extinguishers filled with MAP powder along with squeez grip release valve,pressure gauge,discharge pipe and locking arrangement etc complete in all respect as required.
17
-
-
Supply of new CO2 type 4.5 kg capacity fire extinguishers filled with CO2 gas along with pvc bend horn and fixing hook etc complete in all respect as required.
17
-
-
Total: Sub Head-II (Fire Alarm System)
-
-
-
Grand Total: (Sub Head-I+Sub Head-II)
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements