Government Institute Of Medical Sciences Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Government Institute Of Medical Sciences - GIMS Tender
Eprocure
Opening Date24 Feb 2021
Closing Date17 Mar 2021
Tender AmountRefer Documents
Costs
EMD
₹ 2,00,000Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_RASGN_556569_8Bid Award Id
ViewTender No
GIMS/2021/TENDER/07 dtd. 17.02.2021Tender Authority
Government Institute Of Medical Sciences ViewPurchaser Address
-Website
http://etender.up.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
pH - 5.5 - 9.0
-
-
-
BOD5 - 250 - 600 mg/l
-
-
-
S. Solids - 200 - 650 Mg/l
-
-
-
COD - 600 - 1200 mg/l
-
-
-
Oil & Grease - 220 Mg / L
-
-
-
DISCHARGE EFFLUENT CHARACTERSTICS AFTER TREATMENT
-
-
-
pH - 7.0 - 8.5
-
-
-
BOD - Less than 30 Mg/L
-
-
-
S. Solids - Less than 100 Mg/L
-
-
-
COD - Less than 100 Mg/L
-
-
-
Effluent treatment plant shall include the following items:
-
-
-
Screen Chamber
-
-
-
Oil & Grease Trap
-
-
-
Effulent collection tank
-
-
-
Batch Reactor
-
-
-
Primary Tube Settler Tank
-
-
-
MBBR 1 & 2 Tank
-
-
-
Secondary Tube Settler Tank
-
-
-
Filter Feed Tank
-
-
-
Dosing system
-
-
-
Air Blowers, Pumps & equipment
-
-
-
Piping, valves etc
-
-
-
Treated Water Storage Tank
-
-
-
Tertiary Treatment
-
-
-
Electrical Control Panel & Cabling
-
-
-
EFFLUENT TREATMENT PLANT
-
-
-
Contractor shall ensure submission of detailed GA drawings (Plan & Section), P & I diagram, schematic diagram for the above mentioned components and additional components if so required for the complete work.
1
-
-
Supply, installation, testing & commissioning of 2 Nos Stainless Steel Perforated Screen with suitable lifting arrangement(size 400 x 500 mm high approx). Required perforation of 10 mm and 8 mm respectively.
2
-
-
Make-EESPL/Thermax/Ion Exchange
-
-
-
Supply, installation, testing & commissioning of non clogging type pumps capable of handling solids (as stated for respective pump type), having C.I casing & C.I impeller complete with all accessories, motor of required capacity, with isolation cock, integration with level controller (with wiring) to control the level of sump automatically. Cost Shall also be inclusive of Isolation Ball Valve and NRV as stated under respective pump item. Pumps shall have following duty:
-
-
-
Effluent transfer pump : 2 No(1W+1S)
4
-
-
Flow rate (each) = 1.0 m3/hr
-
-
-
Head = 8-10 Mtr
-
-
-
EFFLUENT TREATMENT PLANT
-
-
-
(Solid handling size for this pump shall be 25-30 mm).
-
-
-
Plant room pump : 2 No(1W+1S)
2
-
-
Flow rate (each) = 2 m3/hr
-
-
-
Head = 10-12 Mtr
-
-
-
(Solid handling size for this pump shall be 11 mm).
-
-
-
Sludge transfer/Recirculation pump 2 No (1W+1S)
2
-
-
Flow rate (each) = 0.5 m3/hr
-
-
-
Head = 8-10 Mtr
-
-
-
Make- wilo/Kirloskar
-
-
-
Air diffusion system shall include the following:
-
-
-
2 Nos. twin type rotary air blowers (1W+1S) capable of delivering 35 cum/hr of free air at 0.30 kg/cm2 driven through “V” belt or directly coupled through flexible coupling to a TEFC motor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply.
2
-
-
Make- Akash/Airvak/Beta
-
-
-
Non clog type air dispersion system capable of handling 3-5 cfm of air with oxygen transfer efficiency of 3-4% per/meter water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired.
1
-
-
Make- MM Aqua/Universal
-
-
-
Air piping shall comprise of pipes droppers/ laterals with MS header complete with all fittings such as tees, crosses, plugs, sockets, elbows, reducers, supports & clamps, puddle flanges etc cutting chases & making good. Contactor to submit detailed P & I indicating their proposal.
1
-
-
Make - Jindal Hisar
-
-
-
Providing and fixing all piping (as described below) and isolation control valves for making the system complete. All valve shall have flanged joints. Flange connection shall be provided wherever required.
-
-
-
uPVC - All piping before & after Filter feed tank.
-
-
-
GI - All Submerged Pipe
1
-
-
Make- MS/GI - Jindal, upvc - Astral/Prince
-
-
-
Supply, installation, testing and commissioning of PVC tube deck settling media to be installed in Primary & Secondary tube settler Tanks.
1
-
-
Make- MM Aqua/Universal
-
-
-
Supply, installation, testing and commissioning of manual operating Filter Press suitable for 15 KLD daily average flow, Plate Size = 12"x12", 12 nos plate, operating pressure 1-2 Kg/Cmsq., PP Butterfly type filter cloth, poly dosing tank=100 ltrs., poly electrolyte fluid to be dosed with interconnecting piping complete in all respect with screw pump.
1
-
-
Make- Universal/Pharmatech
-
-
-
Supply,installation,testing and commissioning of 100 liter dosing tanks in HDPE
3
-
-
Make - Syntex
-
-
-
Supply, installation, testing and commissioning of chemical dosing pump of 0-6 lph
3
-
-
Make- Asia LMI
-
-
-
Online Digital PH Meter
1
-
-
Make - Aster
-
-
-
Supply, installation, testing & commissioning of Electro-magnetic type Flow Meter .
1
-
-
Make - Kushal
-
-
-
EFFLUENT TREATMENT PLANT
-
-
-
Supply, installation, testing and commissioning of PVC Floating media to be installed in Moving Bed Bio- Reactor for 15 KLD plant of required surface area for 400 m2 bacteria culture complete in all respect.
1
-
-
Make- MM Aqua/Bio Tech
-
-
-
TOTAL OF EFFLUENT TREATMENT PLANT CARRIED OVER TO SUMMARY
-
-
-
TERTIARY TREATMENT SYSTEM AND EQUIPMENT
-
-
-
Supply, Installation, Testing & Commissioning of Single Stage Horizontal centrifugal Monoblock pumping set with CI body and CI impeller, shaft of stainless steel SS and SS shaft sleeve, mechanical seal, connected to a TEFC induction motor suitable for 400/440 volts, 3 phase 50 cycles A.C. supply with 150 mm dia pressure gauge with gunmetal isolation cock, level controller, vibration eliminating pads as required, M.S fabricated base plate bolted to cement concrete foundations complete.
-
-
-
Filter Feed Pump
2
-
-
Capacity : 1.5 m3/hr each
-
-
-
Head : 30 M
-
-
-
2 nos.(IWorking + 1Standby)
-
-
-
Make- Kirloskar/wilo
-
-
-
Supplying, installing, testing and commissioning of MSEP filter with media, uPVC Heavy Duty frontal piping complete with Multipord valve Arrangement. Filter shall be suitable for working pressure of 2.5 - 3.0 kgf / sq cm and shall include standard fittings like Legs, pressure gauges, sampling cock, rinse drain.
-
-
-
Pressure SandFilter
-
-
-
Test pressure : 5.5 Kg/Sq.cm
-
-
-
Filteration Rate 12-15 m3/m2/hr
-
-
-
Flow Rate : 1.5 m3/hr
-
-
-
Make-EESPL/Thermax/Ion Exchange/Levana
1
-
-
Activated Carbon Filter
-
-
-
Test pressure : 5.5 Kg/Sq.cm
-
-
-
Filteration Rate 12-15 m3/m2/hr
-
-
-
Flow Rate :1.5 m3/hr
-
-
-
Make-EESPL/Thermax/Ion Exchange/Levana
1
-
-
Supply, installation, testing & commissioning of 100 ltrs HDPE/FRP tank with chemical for with 0-6 lph electronic metering type pump.
1
-
-
Make-Asia LMI
-
-
-
Providing and fixing uPVC pipes complete Fittings, Tee, bends, reducers flanges, plugs unions, Multiport Valve etc., and clamps, including cutting and making good the walls etc. wherever required.
-
-
-
Schedule 40
-
-
-
40 mm nominal bore
45
-
-
50 mm nominal bore
80
-
-
TOTAL OF TERTIARY TREATMENT SYSTEM AND EQUIPMENT CARRIED OVER TO SUMMARY
-
-
-
MS FABRICATED WORK ( Sheet Thickness- 5 mm & FRP-2 mm)
-
-
-
Effluent Equalization Tank
-
-
-
Batch Reactor
-
-
-
Primery Tube Settler Tank
-
-
-
MBBR 1 & 2
1
-
-
Secondary Tube Settler
-
-
-
Filter Feed Tank
-
-
-
Treated Water Storage Tank
-
-
-
Make - Ion Exchange/Thermax/EESPL/Levana
-
-
-
TOTAL OF TERTIARY TREATMENT SYSTEM AND EQUIPMENT CARRIED OVER TO SUMMARY
-
-
-
EFFLUENT TREATMENT PLANT
-
-
-
ELECTRICAL PANEL
-
-
-
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre fabricated out of 14 gauge CRCA sheet steel. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Quoted rates shall be inclusive of cables (in accordance to specification) with earthing from panel to each motor / equipment.
-
-
-
200 amps TPN MCCB with the following accessories:
-
-
-
a. 0-500 volts 96 x 96 mm square electronic voltmeter with selector switch shall be protected by 2 amps TP MCB. 1 Set
-
-
-
b. 0-100amps 96 x 96 mm square digital electronic ammeter with selector switch and 100./5 amps 10 VA CL:1 CTs. 1 Set
-
-
-
c. Phase indicating lamps shall be protected by 2 amp SP MCB 3 Sets
-
-
-
Bus Bar
-
-
-
200 amps TPN (25 KA) copper bus bar with heat shrinkable insulation sleeves.
-
-
-
Single Phase Preventer.
-
-
-
Note :-
-
-
-
Spare : 2 nos,one 32 amp & 63 amp.
-
-
-
Provision shall be made to ensure system protection from dry running of the pump.
-
-
-
All MCCBs shall be of 25 KA breaking capacity and suitable for motor duty application.
-
-
-
Connection Of Star Deta/Dol Strater as per requirement/ approved shop drawing .
-
-
-
Incoming /Busbar/Outgoing as per shop drawing approval.
-
-
-
Including all nessary cable, earthing from panel to pump motor.
1
-
-
TOTAL OF ELECTRICAL PANEL CARRIED OVER TO SUMMARY
-
-
-
Make-Adlec/Tricolite/Delta Design
-
-
-
COMPREHENSIVE OPERATION AND MAINTENANCE
-
-
-
To operate the STP under available load condition. Plant operate in one Shift with minimum 8 hr. Comprehensive Maintanace including consumable chemical, electro mechanical spare, etc. Complete for plant operation.
-
-
-
Company's back up services of senior engineers and experts for any major problems, generals check up and maintanace and advice. One a week for 2 hours minimum more or more if required.
-
-
-
One Plant Operator one in a shift of a day.
-
-
-
Note : AMC will start after handover the plant and after confirmation from client.
-
-
-
First Year after Installation & Commissioning of the plant (Inclusive all type of chemical, chlorine, compressior oil etc.
1
-
-
TOTAL OF OPERATION AND MAINTENANCE CARRIED OVER TO SUMMARY
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements