Tube Investments Of India Limited Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.
Tube Investments Of India Limited - TIDC Tender
Eprocure
Opening Date14 Aug 2020
Closing Date28 Aug 2020
Tender Amount₹ 22,38,263 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 23,613Document Cost
₹ 10,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MTIDC_12098_1Bid Award Id
ViewTender No
TIDC/EE/DNIeT/2020-21/03Tender Authority
Tube Investments Of India Limited ViewPurchaser Address
-Website
http://tripuratenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil
24.09
-
116.4
Banking excavated earth in layers not exceeding 20 cm. in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m. - All kinds of soil
77.25
-
224.9
Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
18.03
-
615.7
CEMENT CONCRETE
-
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering –all work up to plinth level 1:5:10 ( 1 Cement: 5fine sand : 10 graded stone aggregate 40 mm nominal size)
26.87
-
6207.7
R.C.C WORK
-
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level: 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
7.06
-
8489.6
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement- (i) In plinth and skirting courses, fillets, columns, pillars, posts and struts ( 1 Cement: 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
4.57
-
8967.3
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- RCC work in beams, lintels, bands, plain window sills, staircases and spiral staircases excluding precast spiral staircase. (i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
4.64
-
8807.5
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level. (i) Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars
2441.1
-
59.7
Centering shuttering including strutting, propping etc. and removal of form work for:
-
-
-
(i) Foundations, footings, bases for columns etc. for mass concrete with timber plank
39.48
-
226.1
(ii) Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply
114.3
-
327.7
(iii) Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply
73.2
-
429.3
BRICK WORK
-
-
-
First class brick work in foundation and plinth including cost of all materials as required complete:-
(i) In cement mortar 1:4 ( 1 cement : 4 fine sand ).
36.03
-
5408.6
Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:- (i) In cement mortar 1:4 ( 1 cement : 4 fine sand ).
296.34
-
787.3
FLOORING
-
-
-
Providing and laying cement concrete 1:2:4 (cement: 2 fine sand: 4 graded stone aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips etc. complete.
-
-
-
(i) 25 mm thick with 12.5 mm stone aggregate
174
-
348.5
STEEL WORK
-
-
-
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (i) Hot finished welded type tubes - 88mm Dia MS Pipe
3358.42
-
107.2
Providing structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required.
-
-
-
(i) Ms plates 8mm thick
542.59
-
63.7
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:- In grating, frames, guard bar, railing, brackets, gates and similar works, all complete.
-
-
-
(i) Plate 50x5mm
144
-
88.7
Providing and fixing M.S. round holding down bolts with nuts and wahser plates complete as per standard design.
202.24
-
76.3
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 275mm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters & with handles, hold fast including embedding in cement concrete of required grade required for fixing in position, all necessary fittings, including applying of approved steel primer etc. complete as required:-
182
-
1830.5
ROOFING
-
-
-
Supply & installation of pre painted Galvalume sheets (size, shape and pitch of corrugation as approved by Engineer-incharge) in 550mpa steel grade, made out of Cold rolled steel coated with Znic-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to ASTM A 792/A782M, ASTM A90/A90M, ASTM AS 1937, ASTM A924/A92M, Alloy coating AZ150/AZ100, colour coated with high quality polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required. (i) 0.40mm thickness
280.8
-
618.6
Supply & installation of pre painted Galvalume sheets roofing accessories in 550mpa steel steel grade, made out of Cold rolled steel coated with Znic-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to ASTM A 792/A782M, ASTM A90/A90M, ASTM AS 1937, ASTM A924/A92M, Alloy coating AZ150/AZ100, colour coated with high quality polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation. The sheet shall be fixed using self drilling /self tapping screws with EPDM seal or with polymer coated J or L hooks, bolts and nuts G.I. seam bolts and nuts, G.I. plain and bitumen wishers complete for Ridges/Valley/Gutter/Flashing of width 610mm: (i) 0.40mm thickness
36
-
349
FINISHING WORK
-
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix: (i) In cement mortar 1 : 4 ( 1 cement : 4 fine sand )
218.8
-
174.8
12 mm cement plaster of mix (i) In cement mortar In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) Plinth protection
493.96
-
150.5
Neat cement punning.
118.4
-
44.3
Painting with synthetic enamel paint ( two or more coats ) of required colour of approved brand and manufacture on new work to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]
323.12
-
73.9
Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]
493.96
-
73.7
Finishing walls with water proofing cement paint of required shade of approved brand and manufacture on new work ( two or more coats applied @ 3.84 kg/10 sqm) complete. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]
218.8
-
53.3
Electrification
-
-
-
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLSPVC insulted copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switsh, modular plate, suitable GI box and earthing the point with 1,5 sq.mm FRLSPVC insulted copper conductor single core cable etc.as required.
-
-
-
(i) Group C
100
-
644
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLSPVC insulted copper conductor single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
i) 2x 2.5 sq.mm+1x 2.5 sq.mm earth wire
183.45
-
131
ii) 2x 4sq.mm+1x 4sq.mm earth wire
100
-
162
Supplying and fixing suitable size GI box with modular plate and cover in front of surface or in recess,including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet &15/16 modular switch, connections etc.as required
10
-
366
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc.as required.
-
-
-
i) 5/6 A switch
10
-
75
ii) 3 pin 5/6 A socket outlet
10
-
96
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc as required
10
-
322.99
Installation, testing & commissioning of ceiling fan, including wiring the down rods of standard length(upto 30 cm) with 1.3 sq.mm FRLSPVC insulted copper conductor single core cable etc. as required
10
-
73.5
Supplying and fixing following way, single pole & neutral, sheet steel, MCB distribution board,240 v, on surface/recess, complete with tinned copper bus bar, neutralbus bar ,earth bar, din bar, interconnections, powder pointed including earthing etc as required(but without (MCV/RCCB/ISOLATOR)
-
-
-
(i) 8 way Double door
10
-
778
Supplying and fixing 5A and 32 A rating, 240/415V,10KV, curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc as required.
-
-
-
(i) Single pole
80
-
141
Supplying and fixing following rating, double pole,240V, isolator in the existing MCB DB complete with connections testing and commissioning etc as required.
-
-
-
(i) 40A
10
-
245
Installation, testing & commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/wall, including connections with 1.5 sq.mm FRLSPVC insulated, copper conductor, single core cable and earthing etc as required.
10
-
69.5
Earthing with G.I earth pipe 4.5 mtr long,40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/cock and salt as required
2
-
3385
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required
60
-
30
Supplying of ceiling fans of size 1200mm sweep including with all accessories as required crompton make
10
-
2000