Tripura State Electricity Corporation Limited Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.

Tripura State Electricity Corporation Limited - TSECL Tender

Works
Civil And Construction
Electrical and Electronics
Eprocure
Opening Date5 May 2021
Closing Date3 Jul 2021
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
G.I. Channel cross arm 100x50x6x3150 mm

256

-

-

... More
GI Channel top bracket, 100x50×6×310mm (for top pin insulator)

225

-

-

... More
G.I Channel cross arm 100x50x6x1570 mm

225

-

-

... More
Cross arm bottom Support GI V bracket , Type C12-V (for single pole cross arm)

225

-

-

... More
33 kV Composite (Polymer) Tension Insulator, 45 kN with all accessories

654

-

-

... More
33 kV Composite Insulator Tension Hardware, 45 kN suitable for stringing covered conductor including all accessories

654

-

-

... More
Insulating Piercing Connector - 33 kV CC to CC (100 sqmm)

102

-

-

... More
33KV Composite (Polymeric) Pin Insulator tie top type including all accessories

1142

-

-

... More
Non-metallic helical ties for covered conductor

1142

-

-

... More
Insulating Piercing Connector for 33 kV CC (100 sqmm CC- 8 SWG GI wire for LA )

225

-

-

... More
Lightning Arrester (Distribution Class) with polymer housing (suitable for CC), 30 kV , 10 KA, with earth lead disconnector and channel mounting brackets. MCOV : 25 kV or as recommended by CC manufacturer

225

-

-

... More
Insulated Tension Mid Span Joint /Repair Sleeve for 33 kV Covered Conductor (100 sqmm)

15

-

-

... More
Insulating Piercing Connector for 33 kV CC (100 sqmm) to Bare ( 75-150 sqmm)

6

-

-

... More
33 kV 100 sqmm Covered Conductor End Seal Caps, heat or cold shrink type

6

-

-

... More
33KV Covered Conductor Triple Layer Type with AAAC 100 Sqmm (or 99 sqmm) conductor

47

-

-

... More
33 kV G.I Cross Bracing Set made of G.I angles 65x 65x 6 mm , X-type, single Tier (Type : C12-XB)

181

-

-

... More
G.I. Earth pipe, 40mm dia x 2.5 mt. Long with earth conductor clamp including eathing compound for earth pit backfill

331

-

-

... More
G.I. Wire 8 SWG for earthing

662

-

-

... More
H.T. galvanized stay set including anchor plate (300x300x8), nut bolts, turn buckles,1.8 m long 20 mm dia. Solid GS Stay Rod, Thimble complete

406

-

-

... More
H.T. Guy insulator 88KN

406

-

-

... More
G.I Stay wire 7/10 SWG

2842

-

-

... More
33KV Danger plate with clamps

334

-

-

... More
G.I Top Pole Clamp - Type C12-1

1187

-

-

... More
G.I Middle Pole Clamp - Type C12-2

362

-

-

... More
G.I Bottom Pole clamp - Type C12-3

362

-

-

... More
G.I Stay Clamp - Type C12-S

256

-

-

... More
G.I. Nuts & bolts with spring washers - assorted sizes

598

-

-

... More
G.I Barbed wire 12 SWG

281

-

-

... More
Stone Pad, 450x450x50 mm

481

-

-

... More
Concreting Materials, M15 Grade, 0.35 cum per pole including muffling above GL 300 mm

168

-

-

... More
Concreting Materials, M15 Grade, 0.2 cum per stay

81

-

-

... More
Painting Materials for pole numbering per pole (Area 150 x 200 mm)

481

-

-

... More
MANDATORY SPARE PARTS

-

-

-

... More
Insulated Tension Mid Span Joint /Repair Sleeve for Covered Conductor (100 sqmm)

6

-

-

... More
33KV Covered Conductor AAAC 100 Sqmm (or 99 sqmm)

1

-

-

... More
Insulating Piercing Connector for 33 kV CC- CC to CC (100 sqmm)

9

-

-

... More
Insulating Piercing Connector for 33 kV CC -100 sqmm- Earthing (8 SWG)

24

-

-

... More
Insulating Piercing Connector for 33 kV CC (100 sqmm) to Bare ( 75-150 sqmm)

3

-

-

... More
Lightning Arrester (Distribution Class) with polymer housing (suitable for CC), 30 kV , 10 KA, with earth lead disconnector and channel mounting brackets. MCOV : 25 kV or as recommended by CC manufacturer

6

-

-

... More
SSchedule A4 : Schedule of Quantities for new 11 kV Covered Conductor S/C Lines including existing line replacements

-

-

-

... More
Galvanized Steel Tubular Pole 540 SP-57 - 11 mtrs

7719

-

-

... More
G.I. Channel cross arm 100x50x6x2200 mm

4170

-

-

... More
GI Channel top bracket, 100x50×6×310mm (for top pin insulator)

4095

-

-

... More
G.I Channel cross arm 100x50x6x1570 mm

4095

-

-

... More
Cross arm bottom Support GI V bracket , Type C11-V (for single pole cross arm)

4095

-

-

... More
11 kV Composite (Polymer) Tension Insulator, 45 kN with all accessories

8712

-

-

... More
11 kV Composite Insulator Tension Hardware, 45 kN suitable for stringing covered conductor including all accessories

8712

-

-

... More
Insulating Piercing Connector for 11 kV CC to CC (70 sqmm)

1899

-

-

... More
11KV Composite (Polymeric) Pin Insulator tie top type including all accessories

19260

-

-

... More
Non-metallic helical ties for covered conductor

19260

-

-

... More
Insulating Piercing Connector for 11 kV CC : 70 sqmm CC- 8 SWG GI wire for LA

2457

-

-

... More
Lightning Arrester (Distribution Class) with polymer housing (suitable for CC), 9 kV , 10 KA, with earth lead disconnector and channel mounting brackets. MCOV : 7.65 kV or as recommended by CC manufacturer

4095

-

-

... More
Insulated Tension Mid Span Joint /Repair Sleeve for 11 kV Covered Conductor (70 sqmm)

273

-

-

... More
Insulating Piercing Connector for 11 kV CC (70 sqmm) to Bare ( 75-150 sqmm)

2892

-

-

... More
11KV Covered Conductor Triple Layer Type with AAAC 70 Sqmm conductor

860

-

-

... More
11 kV 70 sqmm Covered Conductor End Seal Caps, heat or cold shrink type

2892

-

-

... More
11 kV G.I Cross Bracing Set made of G.I angles 65x 65x 6 mm , X-type, single Tier (Type : C11-XB)

2805

-

-

... More
G.I. Earth pipe, 40mm dia x 2.5 mt. Long with earth conductor clamp including eathing compound for earth pit backfill

4443

-

-

... More
G.I. Wire 8 SWG (for earthing)

8886

-

-

... More
H.T. galvanized stay set including anchor plate (300x300x8 mm), nut bolts, turn buckles,1.8 m long 20 mm dia. Solid GS Stay Rod, Thimble complete

5262

-

-

... More
H.T. Guy insulator 88KN

5262

-

-

... More
G.I Stay wire 7/10 SWG

36834

-

-

... More
11 kV Danger plate with clamps

5547

-

-

... More
G.I Top Pole Clamp - Type C11-1

18079

-

-

... More
G.I Middle Pole Clamp - Type C11-2

5610

-

-

... More
G.I Bottom Pole clamp - Type C11-3

5610

-

-

... More
G.I Stay Clamp - Type C11-S

3624

-

-

... More
G.I. Nuts & bolts with spring washers - assorted sizes

9891

-

-

... More
G.I Barbed wire 12 SWG

4503

-

-

... More
Stone Pad, 450x450x50 mm

7719

-

-

... More
Concreting Materials, M15 Grade, 0.35 cum per pole including muffling above GL 300 mm

2702

-

-

... More
Concreting Materials, M15 Grade, 0.2 cum per stay

1052

-

-

... More
Painting Materials for pole numbering per pole (Area 150 x 200 mm)

7719

-

-

... More
ADDITIONAL ITEMS FOR CRADLE GUARDING FOR LINE CROSSING (0.5X0.33 m GI wire mesh, Double Pole Section - 50 MTR) - 01 NO PER 6 CKM

-

-

-

... More
G.I. Guard Angles (65×65x6mm-2.2 m)

92

-

-

... More
G.I. Flat back clamp (50x6xmm - 2.2 m)

92

-

-

... More
G.I. Eye Bolt-16 mm

736

-

-

... More
G.I . Turn Buckle

368

-

-

... More
G.I. Wire 8 SWG (for guarding and grounding )

2070

-

-

... More
G.I. wire 6 SWG (for guarding)

2300

-

-

... More
MANDATORY SPARE PARTS

-

-

-

... More
Insulated Tension Mid Span Joint /Repair Sleeve for 11 kV Covered Conductor (70 sqmm)

27

-

-

... More
11KV Covered Conductor Triple Layer Type with AAAC 70 Sqmm conductor

3

-

-

... More
Insulating Piercing Connector for 11 kV CC to CC (70 sqmm)

96

-

-

... More
Insulating Piercing Connector for 11 kV CC : 70 sqmm CC- 8 SWG GI wire for earthing

123

-

-

... More
Insulating Piercing Connector for 11 kV CC (70 sqmm) to Bare ( 75-150 sqmm)

288

-

-

... More
11 kV Covered Conductor End Seal Caps, heat or cold shrink type

288

-

-

... More
Lightning Arrester (Distribution Class) with polymer housing (suitable for CC), 9 kV , 10 KA, with earth lead disconnector and channel mounting brackets. MCOV : 7.65 kV or as recommended by CC manufacturer

42

-

-

... More
Schedule A5 : Schedule of Quantities for New LT ABC Lines and Conversion of existing LT lines to AB Conductor Lines

-

-

-

... More
Galvanized Steel Tubular Pole 540 SP-33 - 9 mtrs

863

-

-

... More
1.1 kV XLPE/Al Cable with one Street LTG conductor and AAAC insulated messenger neutral - 3x70 sqmm + 1x50 sqmm + 1x16 sqmm

121

-

-

... More
Anchoring clamp wedge type for ABC -3x70+1x50+1x16 sqmm (for terminations, large angles & branch lines)

1840

-

-

... More
Suspension clamp for ABC - 3x70+1x50+1x16 sqmm

2530

-

-

... More
Eye Hook for ABC anchoring / suspension clamps

3450

-

-

... More
GI Pole Clamps / Double SS straps for fixing Eye Hook to existing 8 m PCC Poles including GI B&N / Strap Buckles

2415

-

-

... More
GI Pole Clamps / Double SS straps for fixing Eye Hook to 8 m STP Poles including GI B&N / Strap Buckles

1035

-

-

... More
Pre- insulated mid span jointing sleeves - 1 set for ABC - 3x70+1x50+1x16 sqmm

58

-

-

... More
Pre-molded push on type end caps for ABC - 3x70+1x50+1x16 sqmm

345

-

-

... More
Insulated piercing connector for main - main connections, 25-95 / 25-95 sqmm

2760

-

-

... More
Insulated piercing connector 16-35 /16-35 sqmm (for street light conductor main-main connection)

690

-

-

... More
Single phase LT ABC Distribution Box 1 incoming / 6 outgoing including accessories and GI clamps /SS straps for fixing with STP/PCC pole

2300

-

-

... More
Three phase LT ABC Distribution Box 1 incoming / 4 outgoing including accessories and GI clamps /SS straps for fixing with STP/PCC pole

230

-

-

... More
Insulated piercing connector for main - service taps, 25-95 / 6-35 sqmm

28520

-

-

... More
Insulated piercing connector for main - st lighting taps / earthing 16 -95 / 4-35 sqmm

2415

-

-

... More
1x25 sqmm Al/PVC cable

6900

-

-

... More
1x35 sqmm Al/PVC cable

920

-

-

... More
Outdoor Three Phase Fuse-Switch-Disconnector with HRC fuse links rated as recommended for thermal capacity of AB cable and solid link for neutral, pole mounting type with pole mounting brackets / double SS straps for STP / PCC poles

153

-

-

... More
Pre-insulated lugs with bolts and nuts for 70 sqmm Al Conductors for terminating ABC cables at DTR bushing terminals or Dist. Boards

1378

-

-

... More
Pre-insulated lugs with bolts and nuts for 50 sqmm Al Conductors for terminating ABC cables at DTR bushing terminals or Dist. Boards

459.33

-

-

... More
Pre-insulated lugs with bolts and nuts for 16 sqmm Al Conductors for terminating ABC cables at DTR bushing terminals or Dist. Boards

153.33

-

-

... More
2Cx6 sqmm Al/ PVC/PVC service cable

83

-

-

... More
4Cx10 sqmm Al/ PVC/PVC service cable

3

-

-

... More
L.T. galvanized stay set including anchor plate (300x300x8), nut bolts, turn buckles,1.8 m long 16 mm dia. Solid GS Stay Rod, Thimble complete

690

-

-

... More
L.T. Guy insulator

690

-

-

... More
G.I Stay wire 7/12 SWG

3450

-

-

... More
GI Stay Clamps for 8 m STP / PCC Poles including bolts & Nuts

690

-

-

... More
G.I Barbed wire 12 SWG

503.42

-

-

... More
20 mm dia, 1.8 mtr long GI Earth Rod including connecting clamps , bolts & nuts etc.

575

-

-

... More
G.I. Wire 8 SWG (for earthing)

1150

-

-

... More
Stone Pad, 300x300x50 mm

863

-

-

... More
Concreting Materials, M15 Grade, 0.25 cum per pole including muffling above GL 300 mm

302

-

-

... More
Concreting Materials, M15 Grade, 0.2 cum per stay

173

-

-

... More
Painting Materials for pole numbering per pole (Area 100 x 150 mm)

863

-

-

... More
MANDATORY SPARE PARTS

-

-

-

... More
Insulated piercing connector for main - main connections, 25-95 / 25-95 sqmm

276

-

-

... More
Insulated piercing connector 16-35 /16-35 sqmm (for street light conductor main-main connection)

69

-

-

... More
Insulated piercing connector for main - service taps, 25-95 / 6-35 sqmm

1426

-

-

... More
Insulated piercing connector for main - st lighting taps, 16 -95 / 4-35 sqmm

483

-

-

... More
Pre- insulated mid span jointing sleeves - 1 set for ABC - 3x70+1x50+1x16 sqmm

12

-

-

... More
Single phase LT ABC Distribution Box 1 incoming / 6 outgoing including accessories and clamps for fixing with STP/PCC pole

230

-

-

... More
Three phase LT ABC Distribution Box 1 incoming / 4 outgoing including accessories and clamps for fixing with STP/PCC pole

23

-

-

... More
Pre-molded push on type end caps for ABC - 3x70+1x50+1x16 sqmm

35

-

-

... More
Outdoor Three Phase Fuse-Switch-Disconnector with HRC fuse links rated as recommended for thermal capacity of AB cable, pole mounting type with pole mounting brackets / double SS straps for STP / PCC poles

23

-

-

... More
Insulated Operating Rod for Outdoor Three Phase Fuse-Switch-Disconnector

23

-

-

... More
HRC fuse links with blade contacts with fuse rating as per ABC manufacturer recommendations

69

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.