Tripura State Electricity Corporation Limited Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.
Tripura State Electricity Corporation Limited - TSECL Tender
Eprocure
Opening Date25 Feb 2019
Closing Date1 Apr 2019
Tender Amount₹ 20,18,70,347
Costs
EMD
₹ 40,37,407Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_POWER_3598_1Bid Award Id
ViewTender No
GM Tech./2018-19/ 21 dated 22-02-2019Tender Authority
Tripura State Electricity Corporation Limited ViewPurchaser Address
-Website
http://https://www.tsecl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply of 150 mm nominal bore (outer side dia: Min 163.9mm & Max. 166.5mm, Wall thickness: 5.40mm, 21.30Kg /mtr.) heavy duty (C-Class) make best quality GI PIPE as per ISS 1239(Pt-1)-2004, equvalent to BS 1387/1985 of different length as per requirement of engineering for using riser to pole, Kiosk etc, fixing of pipe with the help of 2nos Angle bracket, clamps etc and drawing of 3-phase, 3-core, 19/33KV (E), 300 sqmm XLPE insulated & insulation screened Aluminium Power Cable through GI pipe as per
100
-
-
Supply of 33 KV Vacuum Circuit Breaker outdoor type 1250A, 31.5 KA for 3-sec, 750 MVA rupturing capacity with motor operated spring closing mechanism with supporting structure accessories & tools complete as per technical specification including supply of 2nos Vacuums interrupter, 2nos closing and 2nos tripping coil, 2nos auxiliary switch etc as spare.
2
-
-
Supply of 33 KV, 1250 Amp manually operated horizontal centre rotating type double break triple pole Gang operated isolator without earth switch complete with post insulators, arching horns, mechanical interlocking arrangement and NO/NC auxiliary switches.
15
-
-
Supply of 33 KV, 1250 Amp manually operated horizontal centre rotating type double break triple pole Gang operated isolator with earth switch complete with post insulators, arching horns, mechanical interlocking arrangement and NO/NC auxiliary switches.
4
-
-
Supply of 33 KV, single phase out-door type 3 core CT of ratio 200/1-1Amp of suitable turn ratio as required as per IS 2705
7
-
-
Supply of 30 KV, 10 KA heavy duty LA suitable for operation on 33 KV system conforming to ISI: 3070 (P - I) / 1974 or as per latest ammendment.
27
-
-
Supply of 33 KV single phase, outdoor type potential transformer of ratio 33000V/√3 /110V/√3 as per technical specification
7
-
-
Supply of 33 KV simplex type Control & relay panel complete with wiring links fuses, internal illumination. Panel shall be completed with 1-earth fault & 2-over current combined relay, one master trip relay, auxilary relays, one voltmeter with selector switch and 3-ammeter, one CT, PT operated three phase 4 wire "Tri- Vector" meter (SCADA Compatible), simaphore, mimic bus diagram, Standard indication facilities etc. as per specification including supply of 1no Auto range Digital DCA/ACA Clamp meter.
2
-
-
Supply of Galvanised Steel Structure for 33KV ISO, L.A, PI, gantry & other equipments with Hot Dip Galvanized Nut, Bolts and washer, foundation bolts etc as required.
40
-
-
Supply of Sub-Station Bus Bar materials at GRID S/Stn, Durjyonagar S/Stn and AAI S/Stn, i/nc. equipment bus materials, complete with Al. Tube of OD 65 mm, in/c. Disc & Post Insulators, Earth bonds, nuts & bolts, conductors, connectors, Clamps etc. complete with all accesserores and fittings to complete the bus bar arrengements as per direction of Engineer-In-Charge. a) ACSR "DOG" Conductor (6/4.72 + 7/1.57mm)
1
-
-
b) 7/3.15 mm GI Sheilding wire
1
-
-
c) Al. Tube of 65mmdia
1
-
-
d) 33 KV Post Insulator
1
-
-
e)11 KV 90 KN Disc Insulator with fittings.
1
-
-
f) Clamp and connectors, fittings etc. as per requirement to complete the bay
1
-
-
Supply of 1100Volts grade PVC insulated, PVC Sheathed control cable with armouring of following capacity & core as per IS 1554 (part-I) 1988.
a) 2-core, 2.5mm2 (stranded copper) 1100 V grade armoured power cable as per requirement.
300
-
-
b) 4-core, 2.5mm2 (stranded copper) 1100 V grade armoured power cable as per requirement.
300
-
-
c) 7-core, 2.5mm² (stranded copper) 1100 V grade armoured power cable as per requirement.
300
-
-
d) 12-core, 2.5mm² (stranded copper) 1100 V grade armoured power cable as per requirement.
300
-
-
Supply of Sub-Station Earthing materials complete with 50 X 6 mm hot dip galvanized steel flat as required for all equipment risers & earth mesh and 40mm dia heavy duty (C- class) hot dip GI Pipe as earth electrode as per requirement .
120
-
-
Design,engineering ,manufacturing, insurance,Testing at Ex-works, transportation, loading, unloading, storage, delivery at site & Supply of 110V DC, 300Ah capacity sealed and Maintenance free (SMF) VRLA Battery Bank comprising of 60nos 2.2 Volt each Cell (out of 60 cells, 5(five) Nos being spare) complete with all accessories conforming to relevent ISS as per latest amendment detailed in the technical specification section of the document.
1
-
-
Design, engineering ,manufacturing, insurance,testing at Ex-works, transportation, loading, unloading, storage, delivery at site & supply of 415VAC (plus minus 10%) nominal input Voltage, 50Hz (plus minus 5%), 110Volt DC Output with adjustable range, 40Amp thysristor controlled float cum boost charger (with less than 2% RMS ripple content, without battery connected)less than 60db noise level, constant voltage processed Battery charger compitable for aforesaid VRLA battery Bank conforming to relevent ISS and latest amendment complete with standard protection as per IP-54 to 20 as per IS-2147, built in DCDB, standard indication and controls including switches,temparature range of 50 degree centigrade and painted by RAL 7032 etc as required.
1
-
-
Design, engineering ,manufacturing, insurance, testing at Ex-works, transportation, loading, unloading, storage, delivery at site & supply of 110Volt DC Distribution Board (DCDB) with dust tight, vermin proof, gasketed door, enclosure made of sheet steel 2 mm, thick CRCA, painted by powder coated paint RAL 7032 with Aluminum bus bar of 40x6mm complete with(L&T/GE/C&S/HAVELS) make 1x160Amp TP MCCB as incomer and out going of 6x32A DP MCB, 6x16A DP MCB, analog volt & Amp meter, LED indication, Mains failure and Earth fault Relay etc along with all control and protection gears complete as per requirement including supply of 4nos GI bucket of 10lts capacity with iron stand.
1
-
-
Design, engineering ,manufacturing, Insurance, testing at Ex-works, transportation, loading, unloading, storage, delivery at site & supply of (L& T/SECURE/GE make) 415VAC, 50Hz ACDB complete 200Amp MCCB for incoming supply, 3nos 300/5 (15VA), CTR, 300 aluminum bus bar, 1X100Amp MCB as incomer and outgoing of 4X63Amp MCB, 4X32Amp MCB, as per requirement including provision for Voltage, Amp indications and L&T or SECURE make KWH meter and accessories as required including supply of ABC dry power type 2nos (5Kg each), 2nos CO₂ cylinder (5Kg each) with pressure indicator fire extinguisher.
1
-
-
Supply of Heat Shrinkable TAPEX KITS for three core 33KV(E) Screened XLPE underground Cables
a. Stright through Jointing KIT sutiable for 3 X 300 sqmm XLPE cable
48
-
-
b. Outdoor end Jointing KIT sutiable for 3X 300 sqmm XLPE cable
18
-
-
Outdoor end Jointing KIT sutiable for 3X 300 sqmm XLPE cable
160
-
-
Supply of "T" shape piller for cable line ID marking engraved with caption "33KV UG LINE AIRPORT" made of precast RCC of size (Piller: 3ftX0.33ftX0.33ft) and (T- section; 3ftX0.33ft) by excaviting earth including required painting of the engraved caption in black over yellow back ground as technical requirement, direction of engineer in charge. (100 mtr intervel)
260
-
-
Supply of following T&P(TAPARIA MAKE)
Double ended Spanner Set (product code DEP-12)
2
-
-
Ring Set(Product code 1812)
2
-
-
Adjustable Wrence (Product code 1173-12/1173N-12)
10
-
-
Combination Plier with thick C.A. Sleev product code 1621-8/1621-8N)
10
-
-
Insulated Screw driver (Product code 934)
10
-
-
Insulated Screw driver (Product code 937)
10
-
-
Flat screw Driver (Product code 827)
10
-
-
Flat screw Driver (Product code 925)
10
-
-
Socket set 12.7mm sqare drive (Product Code S16M)
1
-
-
Supply of 5 KV Digital MEGGER
2
-
-
Crimping tool (AAKASH-100) Capacity: 6sqmm to 400sqmm, Weight: 5.8kg
1
-
-
Supply of Compact trolley based Cable fault locator up to 33kv rating
Cable fault locator
1
-
-
Cable route tracer
1
-
-
B. Erection
Detailed Survey of route alignment with covering of existing DT sub-station, H.T & LT line, submission of route alignment, profile and final survey with profile in details including installation of HT & LT KIOSK DT sub-stn, road crossing river, nala. crossing, water supply pipe line, SCADA OFC cable, P & T line etc (for 33KV UG cable line)
24
-
-
Excavation of cable entry pit and Laying, Commissioning of 3-phase, 3-core, 19/33KV (E), 300 sqmm XLPE insulated & insulation screened Aluminium Power Cable in trenches (Dismension: 500mm width & 1500mm depth excluding specific locations where this is likely to very on higher side) including : (a) formation of trench by excavation of soil (b) Supply and spreading of sand in 2(two) layers each of 150mm thick one on trench bed and the other over cable laid (c) Supply and laying of consolidate plain flat double layer of 1st class brick soling over the 2nd layer of spreaded sand (d) Refilling of excavated earth over the flat brick soling work upto the ground level and coiling of excess cable below the earth surface at a depth of minimum 1500mm with spreading of 300mm river sand (below cable 150mm & over cable 300mm) and protecting by double layer 1st class bricks soiling as per site requirement of TSECL.
500
-
-
Laying and commissioning of 3 Core , 19/33 KV (E), 300 sqmm XLPE insulated armoured power cable and 160 mm outer diameter HDPE pipe( PE-80 grade) of working presure 6 kgf /sq.cm. having minimum wall thickness 6.3 to 7.2 mm through HDPE pipe by all terrain horizontal directional drilling, digging machine boaring across the road crossing without affecting the existing road surface at a depth of minimum 1200mm or as per site requirement of TSECL and coiling of excess cable below the earth surface at a depth of minimum 1200 mm with protecting by double layer bricks soiling as per design, specefication & engineering requirement of TSECL.
25000
-
-
Erection of PE 80, PN 6, 160 mm O.D, minimum wall thickness 12 HDPE pipe of above mentioned specification of HDPE Pipe of different length as per requirement of engineering for using riser to pole, Kiosk etc, fixing of pipe with the help of 2nos Angle bracket, clamps etc and drawing of 3-phase, 3-core, 19/33KV (E), 300 sqmm XLPE insulated & insulation screened Aluminium Power Cable through GI pipe as per direction of engineer-in- charge.
200
-
-
Erection of 150 mm nominal bore (outer side dia: Min 163.9mm & Max. 166.5mm, Wall thickness: 5.40mm, 21.30Kg /mtr) heavy duty (C-Class) make best quality GI PIPE as per ISS 1239(Pt-1)-2004, equvalent to BS 1387/1985 of different length as per engineering requirement below the road surface by all terrain by drilling horizontall & mannual digging along & accross the road without effecting the existing road surface upto a depth of minimum 1500mm or as per site requirement and laying of 3-phase, 3-core, 19/33KV (E), 300 sqmm XLPE insulated & insulation screened Aluminium Power Cable through GI pipe as per direction of engineer-in- charge.
100
-
-
Erection, testing and commissioning of 33 KV Vacuum Circuit Breaker outdoor type 1250A, 31.5 KA for 3-sec, 750 MVA rupturing capacity with motor operated spring closing mechanism with supporting structure accessories & tools complete as per technical specification including supply of 2nos Vacuums interrupter, 2nos closing and 2nos tripping coil, 2no auxiliary switch etc as spare.
2
-
-
Erection, testing and commissioning of 33 KV, 1250 Amp manually operated horizontal centre rotating type double break triple pole Gang operated isolator complete with post insulators, arching horns, mechanical interlocking arrangement and NO/NC auxiliary switches. Without earth switch isolator
15
-
-
With earth switch isolator
4
-
-
Erection, testing and commissioning of 33 KV, single phase out-door type 3 core CT of ratio 200/1-1Amp of suitable turn ratio as required as per IS 2705
6
-
-
Erection, testing and commissioning of 30 KV, 10 KA heavy duty LA suitable for operation on 33 KV system conforming to ISI: 3070 (P - I) / 1974 or as per latest ammendment.
27
-
-
Erection, testing and commissioning of 33 KV single phase, outdoor type potential transformer of ratio 33000V/√3 /110V/√3 as per technical specification.
6
-
-
Erection, testing and commissioning of 33 KV simplex type Control & relay panel complete with wiring links fuses, internal illumination. Panel shall be completed with 1-earth fault & 2-over current combined relay, one master trip relay, auxilary relays, one voltmeter with selector switch and 3-ammeter, one CT, PT operated three phase 4 wire "Tri- Vector" meter (SCADA Compatible), simaphore, mimic bus diagram, Standard indication facilities etc. as per specification including supply of 1no Auto range Digital DCA/ACA Clamp meter.
2
-
-
Erection, testing and commissioning Galvanised of Steel Structure for 33KV ISO, L.A, PI, gantry & other equipments with Hot Dip Galvanized Nut, Bolts and washer, foundation bolts etc as required .
40
-
-
Erection, testing and commissioning of Sub-Station Bus Bar materials at GRID S/Stn, Durjyonagar S/Stn and AAI S/Stn, i/nc. equipment bus materials, complete with Al. Tube of OD 65 mm, in/c. Disc & Post Insulators, Earth bonds, nuts & bolts, conductors, connectors, Clamps etc. complete with all accesserores and fittings to complete the bus bar arrengements as per direction of Engineer-In-Charge. a) ACSR "DOG" Conductor (6/4.72 + 7/1.57mm)
1
-
-
b) 7/3.15 mm GI Sheilding wire
1
-
-
c) Al. Tube of 65mmdia
1
-
-
d) 33 KV Post Insulator
1
-
-
e)11 KV 90 KN Disc Insulator with fittings.
1
-
-
f) Clamp and connectors, fittings etc. as per requirement to complete the bay
1
-
-
Laying, testing and commissioning of 1100Volts grade PVC insulated, PVC Sheathed control cable with armouring of following capacity & core as per IS 1554 (part-I) 1988.
a) 2-core, 2.5mm2 (stranded copper) 1100 V grade armoured power cable as per requirement.
300
-
-
b) 4-core, 2.5mm2 (stranded copper) 1100 V grade armoured power cable as per requirement.
300
-
-
c) 7-core, 2.5mm² (stranded copper) 1100 V grade armoured power cable as per requirement.
300
-
-
d) 12-core, 2.5mm² (stranded copper) 1100 V grade armoured power cable as per requirement.
300
-
-
Erection, testing and commissioning of Sub-Station Earthing materials complete with 50 X 6 mm hot dip galvanized steel flat for all equipment risers & earth mesh and 40mm dia heavy duty (C- class) hot dip GI Pipe as earth electrode as per requirement
120
-
-
Erection, testing & commissioningn of 110V DC, 300Ah capacity sealed and Maintenance free (SMF) VRLA Battery Bank comprising of 60nos 2.2 Volt each Cell (out of 60 cells, 5(five) Nos being spare) complete with all accessories conforming to relevent ISS as per latest amendment detailed in the technical specification section of the document.
1
-
-
Erection, testing & commissioning of 415VAC (plus minus 10%) nominal input Voltage, 50Hz (plus minus 5%), 110Volt DC Output with adjustable range, 40Amp thysristor controlled float cum boost charger (with less than 2% RMS ripple content, without battery connected)less than 60db noise level, constant voltage processed Battery charger compitable for aforesaid VRLA battery Bank conforming to relevent ISS and latest amendment complete with standard protection as per IP-54 to 20 as per IS-2147, built in DCDB, standard indication and controls including switches,temparature range of 50 degree centigrade and painted by RAL 7032 etc as required.
1
-
-
Erection, testing & commissioning of 110Volt DC Distribution Board (DCDB) with dust tight, vermin proof, gasketed door, enclosure made of sheet steel 2 mm, thick CRCA, painted by powder coated paint RAL 7032 with Aluminum bus bar of 40x6mm complete with(L&T/GE/C&S/HAVELS) make 1x160Amp TP MCCB as incomer and out going of 6x32A DP MCB, 6x16A DP MCB, analog volt & Amp meter, LED indication, Mains failure and Earth fault Relay etc along with all control and protection gears complete as per requirement including supply of 4nos GI bucket of 10lts capacity with iron stand.
1
-
-
Erection, testing & commissioning of (L& T/SECURE/GE make) 415VAC, 50Hz ACDB complete 200Amp MCCB for incoming supply, 3nos 300/5 (15VA), CTR, 300 aluminum bus bar, 1X100Amp MCB as incomer and outgoing of 4X63Amp MCB, 4X32Amp MCB, as per requirement including provision for Voltage, Amp indications and L&T or SECURE make KWH meter and accessories as required including supply of ABC dry power type 2nos (5Kg each), 2nos CO₂ cylinder (5Kg each) with pressure indicator fire extinguisher.
1
-
-
Erection of Heat Shrinkable TAPEX KITS for three core 33KV(E) Screened XLPE underground Cables
Stright through Jointing KIT sutiable for 3 X 300 sqmm XLPE cable
48
-
-
Outdoor end Jointing KIT sutiable for 3X 300 sqmm XLPE cable
18
-
-
C.Erection Civil Work
Earth work in excavation (Hydraulic excavator/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed.
All kinds of soil
550
-
-
Earth work in excavation by mechanical means (Hydraulicexcavator / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
1475
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
All kinds of soil
1475
-
-
Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
385
-
-
Earth work in excavation in all kind of soil and filling in ground depression, pond etc in regular horizontal layers each not exceeding 20 cm in depth, consolidating, watering, rolling each layer with ½ ton roller or wooden or steel rammer and rolling every 3rd layer & top most layer with power roller minimum 8 ton including carriage of earth by mechanical transport from average distance of 10 km with all lead and lift (earth shall be arranged by the agency at his own cost and risk) as per direction of Engineer-in-charge.
950
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering –
A. All work upto plinth level:
i) 1:5:10 (1 Cement: 5 fine sand: 10 graded well burnt brick aggregate 40 mm nominal size).
120
-
-
ii) 1:3:6 (1 Cement: 3 fine sand: 6 graded stone aggregate 40 mm nominal size).
90
-
-
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement -
A. All work upto plinth level;
i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
315
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement –
A. RCC work in suspended floors, roofs having slope upto 15° landings, balconies, shelves and chajjas.
i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
7.5
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-
A. RCC work in beams, lintels, bands, plain window sills, staircases and spiral staircases excluding precast spiral staircase.
i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size).
9.5
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-
A. In plinth and skirting courses, fillets, columns, pillars, posts and struts.
i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size).
5
-
-
B. In walls ( any thickness) including attached pilasters, buttresses piers, abutments etc
i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size).
95
-
-
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level.
i) Thermo-Mechanically Treated bars / Cold twisted deformed steel bars
67175
-
-
Centering shuttering including struttings, propping etc. and removal of form work for:
i) Foundations, footings, bases for columns etc. for mass concrete with timber plank.
590
-
-
ii) Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply.
60
-
-
iii) Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply
45
-
-
iv) Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply
50
-
-
v) Walls ( any thickness) including attached pilasters, buttresses, plinth and string courses etc using shuttering ply
475
-
-
vi) Stairs (excluding landings) except spiral-staircases with wooden plank.
20
-
-
First class brick work in foundation and plinth including cost of all materials as required complete:-
i) In cement mortar 1:6 (1 cement : 6 fine sand).
295
-
-
First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:-
i) In cement mortar 1:6 (1 cement : 6 fine sand).
35
-
-
Half brick masonry work with first class bricks in foundation and plinth including cost of all materials as required complete:-
i) In cement mortar 1:4 (1 cement : 4 fine sand).
20
-
-
Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-
i) In cement mortar 1:4 (1 cement : 4 fine sand).
100
-
-
Providing and fixing aluminium work for doors, windows, ventilators, stair railing including hand rail and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling to be paid for separately) :-
A. For fixed portion of approved quality:-
i) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).
60
-
-
B. For shutters / sliding shutters of doors, windows & ventilators including providing and fixing hinges / pivots / rollers and making provision for fixing fittings wherever required including the cost of PVC / neoprene gasket required of approved quality (Fittings shall be paid for separately):-i) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).
45
-
-
Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition frames with PVC / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge :- A. With glass / float glass panes of 4.0 mm thickness (weight not less than 10.0 kg / sqm).
15
-
-
B. With glass / float glass panes of 5.5 mm thickness (weight not less than 13.50 kg / sqm).
12
-
-
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part-I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters .i) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
10
-
-
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : i) Karai wood.
0.18
-
-
Providing and fixing panelled / or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked bright finished / black enamelled M.S butt hinges with necessary screws excluding panelling and or glazing, which will be paid for separately but including the wooden beading of 20 × 12 mm for fixing panelling and or glazing as per direction of Engineer-in-charge.A. Gamair Wood.
i) 35 mm thick shutters.
2.52
-
-
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.
i) Fixed to openings / wooden frames with rawl plugs screws etc.
4500
-
-
Providing and fixing in position collapsible steel shutters with vertical channels 20 x 10 x 2 mm at 100 mm centre to centre and braced with flat iron diagonals 20 x 5 mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia. steel pulleys & with riveted bolts, nuts, locking arrangement, stoppers, handles, hold fast / anchor bolt including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required.
6.3
-
-
Providing and fixing chromium plated brass handles with necessary screws etc. complete:
i) 125 mm.
5
-
-
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
i) 300 x 10 mm.
6
-
-
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete.
i) 300 x 16 mm.
4
-
-
Providing and fixing fan clamp type-I of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs during laying including painting the exposed portion of loop, all as per standard design complete.
4
-
-
Providing and fixing marble stone in floors over 20mm thick bed of cement mortar 1 : 4 (1 cement : 4 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with of matching shade including rubbing and polishing complete.
18mm thick marble stone
Udaipur green marble
20
-
-
Providing and laying cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. complete.
i) 40 mm thick.
90
-
-
12 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete.
i) In cement mortar 1: 6 (1 cement : 6 fine sand)
500
-
-
15 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete.
i) In cement mortar 1: 6 (1 cement : 6 fine sand)
160
-
-
6 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete.
i) In cement mortar 1: 3 (1 cement : 3 fine sand)
35
-
-
12 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete.
i) In cement mortar 1: 4 (1 cement : 4 fine sand)
260
-
-
Neat cement punning.
75
-
-
Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture on new work (two or more coats applied @ 1.67 kg / 10 sqm) over and including base coat water proofing cement paint applied @ 2.20 kg / 10 sqm complete.
470
-
-
Wall painting with acrylic emulsion paint (two or more coats) of required colour of approved brand and manufacture on new work to give an even shade.
250
-
-
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepared the surface even and smooth complete.
250
-
-
Applying priming coat:
i) With ready mixed pink primer of approved brand and manufacture on wood work (hard & soft wood).
20
-
-
ii) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel, galvanised iron / steel work.
375
-
-
Painting with synthetic enamel paint (two or more coats) of required colour of approved brand and manufacture on new work to give an even shade.
375
-
-
Providing, hoisting and fixing upto floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like including the cost of required centring, shuttering, finishing smooth with 6mm thick cement plaster 1:3 (1cement : 3 fine sand) on exposed surfaces complete, but excluding cost of reinforcement with cement concrete 1:2:4 (1cement : 2 fine sand : 4 graded stone aggregate 20mm nominal size).
97
-
-
Providing 1.8 mtr height chain link fenching around substation areas with angle post 65X65X6mm placed every 2.5 mtr apart embeded in cement concret block of 30X30X60mm of 1:3:.6 (1 cement : 3 river sand : 6 jhama brick aggregate 20 mm. nominal size) and every 12th post and corner post to be shrutted and embeded in cement concrete block of 45X45X60mm of same mix, both two post should be fitted with GI stapple of M.S flat of 6mm. Two suitable gates made of 50mm dia GI pipe and chain link are to be provided within substation fenching (width of gate shall be 4 mtr and height 1.8 mtr and the 2nd gate of 1.2 mtr width 1.8 mtr height.
180
-
-
providing and laying brick on edge soling layer on prepared subgrade according to lines, grade and cross section shown on the drawing, filling joint with earth, free from clay with a plasticity index not exceeding 6, watering and rolling the same with three wheeled road roller 80 - 100KN as per MoRD technical specification clause 412.
85
-
-
Providing, laying, spreading and compacting 63mm to 0.075mm jhama brick aggregate to water bound macadam speccification including spreading in uniform thickness, hand packng rolling with three wheel roller 80 - 100KN in stage to proper grade and camber, applying and brooming binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per MoRD technical specificartion clause 405applying By Mechanical means.
60
-
-
Filling pot holes and patch repairs with bituminious concrete 40mm. Removal of all failed material, trimming of completed excavation to provide firm vertical faces, cleaning of surface, painting of fack coat on the sides and base of excavation as per clause 503, back filling the holes with hot bituminious materials as per clause 511, compacting, trimming and finishing the surface to form a smooth continious surface, all as per MoRT & H technical specification clause 3004.2A. Grading - 1(19mm nominal size).
5000
-
-