Tripura State Electricity Corporation Limited Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.
Tripura State Electricity Corporation Limited - TSECL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Jan 2023
Closing DateCancelled
Tender Amount₹ 22,47,626
Costs
EMD
₹ 44,953Document Cost
₹ 3,540Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_POWER_36718_1Bid Award Id
ViewTender No
DGM/ED-II/TSECL/2022-23/31. dt. 11.01.2023Tender Authority
Tripura State Electricity Corporation Limited ViewPurchaser Address
-Website
http://tripuratenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply of 11KV Stay/Guy insulator (porcelin)
10
-
-
Supply of fabricated MS Channel as per requirement of site condition and suitable for HT/LT over head line and as directed by the Engineer-In-charge made by (75X40X40X6mm) with double coat of red oxide primer coating
251
-
-
Supply of fabricated MS Channel as per requirement of site condition and suitable for HT/LT over head line and as directed by the Engineer-In-charge made by (7100x50X50X6mm) with double coat of red oxide primer coating
107
-
-
Supply of fabricated MS angle as per requirement of site condition and suitable for HT/LT over head line and as directed by the Engineer-In-charge made by (65X65X6mm) with double coat of red oxide primer coating
65
-
-
Supply of 11KV Polymer composite 45KN disc insulator
18
-
-
Supply of 11KV Disc fittings for 6/1/2.59 mm ACSR conductor, 2 U bolt type
18
-
-
Supply of 11KV 320mm CD Polymer composite Pin insulator
30
-
-
Supply of LT Shackle insulator (3"X3.5")
60
-
-
Supply of Straps with nuts & bolts
38
-
-
Supply of 500KVA, 11/0.433KV distribution transformer
2
-
-
Supply of 11KV Gang operated switch (Polymeric type)
3
-
-
Supply of 11KV Drop out switch (Porcelin)
2
-
-
Supply of 11KV Polymeric LA (9KV, 5KA)
6
-
-
Supply of fabricated copper strip M(320X50X6mm)
8
-
-
Supply of assorted MS Nuts & bolts (16mm & 12mm dia)
25
-
-
Supply of (karai) wooden Plank (2'X1'X1.5")
4
-
-
Supply of 1/2" dia polythin pipe
96
-
-
Supply of fabricated bracket clamps of assorted size of MS flat (50 x 6 mm) with double coat of red oxide primer coating
110
-
-
Supply of ACSR (Rabbit) Conductor (6/1/3.35mm)
2
-
-
Supply of ACSR (Weasel) Conductor (6/1/2.59mm)
3.5
-
-
Supply of GI wire (8 SWG)
60
-
-
Supplying and fixing of following oputdoor LED luminaries complete with powder coated housing and heat resistant tempered glass/diffuser in/c necessary connection etc. as required, 30-36watt LED street light fixture (IP-65) :- approved PWD SOR-2017, SL No-1402
20
-
-
Wiring for circuit/sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC conduit in/c necessary connection etc. as required. (2x6 sqmm).
120
-
-
Supplying and fixing of following modular accessories in/c necessary connection etc. as required. 20-32Amps one way DP switch (2M):, SL No-609e
4
-
-
Supplying and fixing of GI pipe (meduem gauge ) bracket fabricated at suitable angle for fixing outdoor light on wall/RCC base with necessary MS clamp , nut , bolt etc as required : 40mm dia
50
-
-
MS pilfer Box for single ph metering (18x12x8)
4
-
-
Dismantling of 11 KV Pin insulator along with Pin.
16
-
-
Dismantling of 11 KV Single Disc insulator set along with necessary fittings.
9
-
-
Dismantling of (Single Conductor) ACSR 6/1/2.59mm dia 'WEASEL' including Coiling etc. Complete as required.
1.5
-
-
TRANSFORMER BASE (6 Leg) X 2 Nos. Earth work in excavation by mecanical means (Hydraulic excavator)/manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms , lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 m. All kinds of soil
28
-
-
Filling available excavated earth ( excluding rock) in trenches, plinth , sides of foundations etc. in layers not excceding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m. (All kinds of soil)
17.9
-
-
Supplying and filing in plinth, under floor, foundations etc. with sand ( fine) from quarry with all lifts including spreading in horizontal layers , watering grading to required slope, ramming ,consolidating and compacting each layer by using plate compactor or by any suitable method complete
1.4
-
-
Providing and layaing in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: 1:4:8 ( 1 cement : 4 fine sand : 8 graded stone aggregate 40 mm nominal size
2.4
-
-
Reinforcement for RCC work including straightening, cutting , bending , placing in position and binding all complete upto floor five level. i)Mild steel and Medium/Tensile steel bars
1140
-
-
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement. :All work upto plinth level (a) 1:1 ½:3 ( 1 cement : 1 ½ fine sand : 3graded stone aggregate 20 mm nominal size )
19.9
-
-
Reinforced cement concrete work in walls ( any thickness), including attached pilasters , buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering , finishing and reinforcement. In plinth and skirting courses, fillets, column, pillars, posts and struts, 1:1½:3 ( 1 cement : 1 ½ fine sand : 3graded stone aggregate 20 mm nominal size )
0.8
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15* landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding cost of centring, shuttering , finishing and reinforcement. RCC work in beams , lintels, bands plain window sills, staircases and spiral staircases excluding precast spiral staircase,1:1½:3 ( 1 cement : 1 ½ fine sand : 3graded stone aggregate 20 mm nominal size ) nominal size
1.7
-
-
RCC work in suspended floors, roofs having slope upto 15* landings, balconies, shelves and chajjas. (a) 1:1 ½ : 3 (1 cement : 1 ½ fine sand : 3 graded stone aggregate 20 mm nominal size)
2.5
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15* landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding cost of centring, shuttering , finishing and reinforcement. Centering shuttering including struttings, propping etc. and removal of form work for: Foundations, footing bases for columns
20.4
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15* landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding cost of centring, shuttering , finishing and reinforcement. Centering shuttering including struttings, propping etc. and removal of form work for: Columns , piers, Abutments, posts struts
13
-
-
Lintels, beams, plinth beams,girders, bressumers and cantilevers with shuttering ply
24
-
-
Suspending floors, roofs landings balconies and access platform with 12mm thick shuttering ply
20
-
-
First calss brick work in foundation and plinth including cost of all materials as required complete:- In cement morter 1:4( 1 cement ;4 fine sand)
2.4
-
-
12mm cement plaster of mix.(a)cement mortor 1:4 ( 1 cement: 4 fine sand)
64
-
-
Neat cement punning.
32
-
-
Providing structural Steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required:-
57
-
-
Providing and fixing with hard drawn steel wire fabric 75x25mm mesh of weight not less than 7.75kg per sqm to window frames etc. including 62x16 mm beading of Gamair wood
24
-
-
Providing and fixing ISI marked oxidised MS sliding door bolts with nuts and screws etc. Complete: 300x16mm
2
-
-
Painting with synthetic enamel paint having VOC ( Volatile Organic Compound ) content less than 150 grams/litre of approved brand and manufacture, including applying additional coats wherever reqd to achieve even shade and colour. [Payment shall be made after submission of Test certificate issued by the manufacturer] i) two coats
24
-
-
Finishing walls with water proofing cement paint of required shade of approved brand and manufacture on new work (two or more coats applied @ 3.84 kg/10 sqm) complete. [Payment shall be made after submission of Test certificate issued by the manufacturer]
32
-
-
Erection of 9.0 mtr. Length of Steel Tubuler Pole atany kind of soil upto a depth of 1/6th of pole height,i/c excavation of of earth, refilling the pit with soil up to the ground level,ramming and making complete in all respect
14
-
-
Erection of stay set complete direct in earth with 19 mm.x 1800 mm long stay rod, anchor plate of size 300 X 300 X 8 mm thimble, turn buckle, 7/3.15 mm dia G.I stranded stay wire and strain insulator etc with supply of MS Clamp, Nuts &bolts etc as required. and making complete in all respect
10
-
-
Erection of MS Channel cross arm, 1.3 to 2.8 mtr. Long 75x40x40x6mm e(xcluding the cost of back Clamp, Nuts & bolts)
8
-
-
Erection of M.S.Angle Cross-Arm, 1.0 to 2.5 Mtr. Long 65 x65 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
4
-
-
Erection of MS Channel cross arm, 1.3 to 2.8 mtr. Long 100x50x50x6mm e(xcluding the cost of back Clamp, Nuts & bolts)
4
-
-
Erection of M.S.Angle Cross-Arm, 1.0 to 2.5 Mtr. Long 50 50 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
12
-
-
Erection of 11KV Pin Insulator along with pin
30
-
-
Erection of 11 KV Single Disc insulator set along with necessary fittings
18
-
-
Erection of shackle insulator of size 75mm x 90mm /100mm X 15mm with straps & bolts/ U-clamp on poles (Excluding the cost of straps / U- clamp, Nuts & bolts).
60
-
-
Laying & Stringing of 1 KM (Single Conductor) ACSR 6/1/3.35 mm dia 'RABBIT' including hoisting & binding etc. Complete as required.
2
-
-
Laying & Stringing of 1 KM (Single Conductor) ACSR 6/1/2.59 mm dia 'WEASEL' including hoisting & binding etc. Complete as required.
3.5
-
-
Laying & strining of 1 KM (Single Conductor) , 10/8SWG GI wire including hoisting & binding etc. Complete as required.
1
-
-
Erection of 9KA,5KA Single pole metal oxide gapless type LA including necessary connection complete as per Technical specification.
6
-
-
Erection of 11KV, DOF unit set of Three nos including necessary connection complete as per Technical specification.(excluding the cost of back clamp, Nuts & Bolts)
2
-
-
Erection of 11KV, 200 Amp GOS unit set of Three nos including necessary connection complete as per Technical specification.(excluding the cost of back clamp, Nuts & Bolts)
3
-
-
Installation /positioning of 11/0.430KV, 3-Phase 500 KVA Distribution transformer on pole with necessary connection & fittings fixing of all allied accessories component as required for making complete in all respect for energizing
2
-
-
Carriage of 9.0mtrs length of steel tubular pole by mechanical transport from the electrical site store to working site vis-a Vis including loading, unloading andstacking etc required. A)upto the lead range 25KM, i)For maximum 8 (eight)pole
14
-
-
Carriage of materials such as cable, AAC,AAAC, ACSR, GI Cross Arm, Stay Set , Insulators etc by mechanical transport from the electrical site store to working site vis-a Vis including loading, unloading andstacking etc required. upto the lead range 25KM & 50 Km
1
-
-
Carriage of 11/.430, 3-phase 500KVA by mechanical transport from the SITE/STORE/WORKSHOP TO WORKING SITE vis-a Vis including loading, unloading and placing on base as required. upto the lead range 25KM
2
-
-
Earthing with GI Pipe 2.5 mtr. Long nd 40 mm. dia with holes including excavation , Refilling with alternate layer of Salt and Charcoal as per drawing (in/c supply of G.I pipe, Salt &charcoal, GI wire, Nuts &bolts, etc as required.
10
-
-
Providing and executing cement concrete work 1:2:4 (1cement, 2river sand, 4 jhama bricks aggregate 20mm nominal Size) for grouting of steel pole/ supporting pillars excluding the cost of centering, shuttering inc. centering, shuttering and excavation in foundation trench not exceeding1.4mtr width in 10sq.mm on plan i/c dressing of side and ramming of bottom lift up to1.5mtr. width i/c getting the excavated soil and direct with in alead of 50mtr(0.273x14nos- )