Tripura State Electricity Corporation Limited Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.

Tripura State Electricity Corporation Limited - TSECL Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date6 Jun 2024
Closing DateCancelled
Tender Amount₹ 56,31,642 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of Fabricated,Aluminium painted MS Clamp for Cross-arm made of 50x6mm MS flat.

134

-

-

... More
Supply of machine made MS Nut & Bolts

175

-

-

... More
Supply, transportation, loading ,unloading, delivery,installation and commissioning at site of indoor type ATS panel made of 12 SWG ( 2.64 mm ) cold rolled MS sheet with powder coated paint comprising of 01 nos. of 630 A rated Automatic Transfer Switch (ATS) Conforms to IEC:60947-1 and IEC:60947-6-1), Four Pole, 50 Hz, 415V automatic / Manual with inbuilt Time delay with enclosure , 04 nos. of 4 pole - 400 Amp MCCB ( 2 nos. for incoming & 2 nos. for outgoing), with LED Indicators lamps, , and Aluminium electrolytic bus bar complete with necessary arrangement for cable connections as per requirement.

1

-

-

... More
Design, Engineering, testing, manufacturing, transportation up to destination, handling, insurance, Supply of 3 Phase, 3-core, 70 Sq.mm., FRLS type, TR, XLPE insulated,, insulation screened Aluminium Conductor Power Cable for 11 KV UG line as per IS 7098/II/1985 with upto date amendments.

120

-

-

... More
Supply of 100 mm dia best quality heavy duty GI PIPE as per ISS 1239 of different length as per requirement of engineering.

96

-

-

... More
Design, Engineering, testing, manufacturing, transportation up to destination, handling, insurance, Supply and making joint of 3 Phase, 3-core, 70 Sq.mm. Out Door Type End Termination Kits for 11KV XLPE insulated, insulation screened Aluminium Conductor Power Cable

4

-

-

... More
Supply of triple pole (3 phase), 12 KV, 200 Amp. Manually gang operated, air brake switch, 3 post vertical type single brake, complete with post insulator for operation in 11 KV, 50 Hz, AC system as per relevant IS specification with supply of clamps, nuts and bolts as required.

2

-

-

... More
Supply of Two pole (3 phase), 12 KV, 200 Amp. DOF, 2 post vertical type , complete with post insulator for operation in 11 KV, 50 Hz, AC system as per relevant IS specification with supply of clamps, nuts and bolts as required.

2

-

-

... More
Supply of Bimetallic lugs. 120 sqmm.

60

-

-

... More
Supply of 11 KV,15 VA single phase outdoor type pole mounted CT of ratio 200-100/1-1 Amp as per specification

6

-

-

... More
Supply of 11 KV,15 VA single phase outdoor type pole mounted PT of ratio 1100/110 as per specification

6

-

-

... More
Supply of 3 phase, 4 Wire , CT/PT operated fully static AMR compatible Tri- Vector Meter with GPRS Modem of accuracy class 0.5s suitable for 110 V ph-ph or 63.5 V Ph-N including meter cover box as per specification.

2

-

-

... More
Supply,installation,testing and commssioning of 120 KVA online UPS as per specification mentioned in Bid document

1

-

-

... More
Supply,installation,testing and commssioning of battery bank made with 12 V SMF, 180 AH , battery for 120 KVA UPS.as per specification mentioned in Bid document

1

-

-

... More
Supply and fitting fixing of Battery rack as per specification mentioned in Bid document

1

-

-

... More
Supply,installation,testing and commssioning of 125 KVA DG set along with AMF Panel as per specification mentioned in Bid document

1

-

-

... More
Schedule B: Execution incl. Civil Works

-

-

-

... More
Erection of Steel Tubular Pole, 9.0mtr. Long (Designation 410: SP-32) conforming to ISS 2713 (P-I & II) 1980 with base plate direct in earth including excavation, refilling and ramming etc. as required complete (1 /6th of the length of the pole to be embedded in earth).

6

-

-

... More
Erection of Fabricated, Alluminium painted 3.0mtr Long, 75X40X40X6mm MS Channel Cross-Arm with help of clamps, nuts and bolts as required as per direction of Eng. In Charge.

70

-

-

... More
Erection of Fabricated, Alluminium painted 3.0mtr Long, 100x50x50x6mm MS Channel Cross-Arm with help of clamps, nuts and bolts as required as per direction of Eng. In Charge.

4

-

-

... More
Erection of Fabricated, Alluminium painted 0.5mtr Long, 100x50x50x6mm MS Channel Cross-Arm with help of clamps, nuts and bolts as required as per direction of Eng. In Charge.

4

-

-

... More
Erection of Polymeric Pin insulator ball and socket type for 11 KV system (Egalvanised-45 KN) conforming to ISS:731/1971.

36

-

-

... More
Erection of 9 KV, 5 KN single pole metal oxide gapless surge type LA suitable for nominal system voltage of 11 KV, 3 phase, 50 Hz, AC supply. Creepage distance 600 mm. conforming to ISS:3070/1985.

6

-

-

... More
Stringing of ACSR, 6/4.72 + 7/1.57sq mm dia DOG conductor including hoistiing, binding, jumpering, etc. as reqd. & as per direction of Engineer-in-charge. (Conductor will be supply by TSECL free of cost)

0.1

-

-

... More
Laying & drawing of 8SWG GI wire i/c. laying from earth electrode to equipments etc.

130

-

-

... More
lnstallation/ Positioning of 11/ 0.430KV, 3-phase , 200 KVA Distribution Transformer with necessary connections & fitting fixing of all allied accessories components as required for making complete in all respect for energizing.

2

-

-

... More
Erection of triple pole (3 phase), 12 KV, 200 Amp. Manually gang operated, air brake switch, 3 post vertical type single brake, complete with post insulator for operation in 11 KV, 50 Hz, AC system as per relevant IS specification with supply of clamps, nuts and bolts as required as per direction of the Eng-In-Charge.

2

-

-

... More
Erection of two pole (3 phase), 12 KV, 200 Amp. DOF, 2 post vertical type , complete with post insulator for operation in 11 KV, 50 Hz, AC system as per relevant IS specification with supply of clamps, nuts and bolts as required as per direction of the Eng-In-Charge.

2

-

-

... More
Boring & Laying of HT/LT(50-400sqmm) XLPE insulated Power cable below the road surface through HDPE/GI pipe by ALL Terrain Horizontal Directional Drilling / Digging across the road crossing without affecting the existing Road Surface at a depth of minimum 1100 mm. including excavation cable entry pits or as per site requirement of TSECL depending on approved route survey. The Cable entry pits should be filled by spreading of Sand.

150

-

-

... More
Laying and Commissioning of HT/LT(50-400sqmm) XLPE insulated armoured power cable direct into earth including excavation of earth upto a depth of 1200mm (Width of the trench 400mm.) including 1st class brick protection of two layer flat brick soling , 600 mm. sand (River sand) cushioning and refilling and ramming the excavated soil and disposal of eccess soil as per direction of Engineer in charge.

30

-

-

... More
Drawing and Commissioning of 3core/3½Core, 120 sqmm to 400sqmm, XLPE insulated, armoured power Cable through GI pipe/HDPE Pipe above ground level for risers to transformer HT/LT side , HT/LT over head Line & HT/LT Feeder Pillar (KIOSK) as per the direction of Engineer-in-charge.

20

-

-

... More
Coiling of all diameter of 3core/3.5 core, HT/LT XLPE insulated armoured power cable direct into earth including excavation of earth upto a depth of 1500mm (diameter of the pit should be 1500mm or as per site requirement.) including 1st class brick protection of two layer flat brick soling , 300 mm. sand (River sand) cushioning and refilling and ramming the excavated soil as per direction of Engineer in charge.

2

-

-

... More
Providing of T-shaped Pillar for cable line ID MARKING engraved with caption "POWER CABLE.LINE" (made of pre-cast RCC) of size(Pillar-3 ft. X 0.33 ft. X 0.33 ft.) and (T-section-3 ft.X0.33 ft.) by excavating earth including required painting of the of the engraved caption in black over yellow background as per technical requirement, direction of the Engineer-in-Charge. The Pillar shall be embedded in earth by 1.5 ft.( for LT UG).

6

-

-

... More
Providing pipe earthing set as per ISS : 3043 of 1966 and with upto date amendment having 2.5 mtr long heavy duty G.I. pipe ( ISI marked ) of 40 mm diameter with holes including a pair of clamps of 50x6 mm M.S. flat & 12 mm dia galvanized nuts & bolts long with alternate layers of salt & charcoal including supply of clamp, salt and charcoal etc.

14

-

-

... More
Erection of 11 KV,15 VA single phase outdoor type pole mounted CT of ratio 200-100/1-1 Amp as per direction of Engg. In charge.

6

-

-

... More
Erection of 11 KV,15 VA single phase outdoor type pole mounted PT of ratio 1100/110 as per direction of Engg. In charge.

6

-

-

... More
Installation of 3 phase, 4 Wire , CT/PT operated fully static AMR compatible Tri- Vector Meter with GPRS Modem of accuracy class 0.5s suitable for 110 V ph-ph or 63.5 V Ph-N including meter cover box as per direction of Engg. In charge.

2

-

-

... More
Grouting of Steel Tubular pole with CC work of ratio1:2:4 ( one cement: two sand: four Jhamma Bricks) aggregate of 20 mm nominal size includung supply of cement,sand and brick aggregate complete with excavation,reffiting of earth ramming along with centering and shuttering as required@0.273 cum/pole as per direction of Engg-in-Charge.

1.64

-

-

... More
Carriage of 11/0.433, 3-Phase , 200 KVA Distribution Transformer by Mechanical Transport from ESD site / MM Store/workshop to working site including loading, unloading and placing on base as required.

2

-

-

... More
Carriage of. 9.0mtrs length of Steel Tubular Poles by Mechanical Transport from the Electrical Sub-Divisional Site/ MM Store to working site including loading, unloading and stacking as required

6

-

-

... More
Carriage of line materials by Mechanical Transport from the MM Store/site to working site, including loading, unloading and stacking as required.

1

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a leadof 50 m. -All kinds of soil

16.8

-

-

... More
Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete

0.84

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-All kinds of soil

10.74

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level:(i)1 : 4 : 8 ( 1 cement : 4 fine sand : 8 graded stone aggregate of 40 mm nominal size)

1.56

-

-

... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level. i)Mild steel and Medium\Tensile steel bars.

684

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level: 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)

5.4

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishingand reinforcement:- 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)

0.6

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)

3.36

-

-

... More
Centering shuttering including struttings, propping etc. and removal of form work for: (i) Foundations, footings, bases for columns. . for mass concrete with timber plank (ii) Columns, piers, abutments, pillaras, posts and struts.(iii) Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply (iv) Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply

53.88

-

-

... More
12 mm cement plaster of mix i)Cement mortar 1:6 ( 1 cement : 6 fine sand )

38.4

-

-

... More
Neat cement punning.

19.2

-

-

... More
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:- i) In stringers, treads, landing etc. of stair cases including use of chequered plate wherever required, all complete.

132

-

-

... More
Providing and fixing paint coated FRP Composite fencing 4mm thick 1.80m height with FRP picket Flat 35x5mm, Hollow Squre section 50x50x3mm embedded in cement concrete block of 150x150x200mm of 1:3:6 ( 1 cement : 3 fine sand : 6 stone aggregate of 20mm size) in/c 50x25x3mm sub frame section, 12mm FRP round rail , hings Door stopper, name plate etc complete as per direction of Engineer-in-charge.

42

-

-

... More
Providing and fixing ISI marked oxidised M.S.sliding door bolts with nuts and screws etc. complete i) 300x16mm

1.2

-

-

... More
Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. [Payment shall be made after submission of Test Certificate issued by the Manufacturer] i) two coats

18

-

-

... More
Finishing walls with water proofing cement paint of required shade of approved brand and manufacture on new work ( two or more coats applied @ 3.84 kg/10 sqm) complete. [Payment shall be made after submission of Test Certificate issued by the Manufacturer) New work ( two or more coats applied @ 3.84 kg/10 sqm)

24

-

-

... More
Neat cement punning.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.