Public Works Department Tender
... More
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Feb 2025
Closing Soon24 Feb 2025
Tender Amount₹ 19,58,910
Costs
EMD
₹ 39,178Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Annual Maintenance Of High Wall, Cassette, Vertical Split Ac And Window Ac System Of Nth I Building, Nth Ii Building, Jayanti Block, Medicine Block, Old Building, Central Laboratory And Other Buildings Under Agmc And Gbp Hospital, Agartala ,tripura
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_CEPWD_58414_1Tender No
78/EE/DNIeT/MECH.DIVN/AGT/2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwd.tripura.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
2.5 /3.0 / 4.0 TR High wall Split, cassette and vertical AC
12
-
-
... More
Leak testing of condenser & evaporator unit for performance and pressure testing etc and repair with brazing as per direction of the Engineer-in-charge.
-
-
-
... More
1.0 / 1.5 / 2.0 High wall split and window type AC.
40
-
-
... More
2.5 / 3.0 / 4.0 TR High wall Split, cassette and vertical AC
5
-
-
... More
Charging / refilling of fresh refrigerant gas (R-22) for 1.0/1.5/2.0/3.0/4.0 TR capacity High wall split / window / cassette / vertical AC system as per direction of the Engineer-in-charge.
-
-
-
... More
R-22
80
-
-
... More
R-32
30
-
-
... More
R-410
35
-
-
... More
R-134,Hydro Carbon, R-600, R-190
5
-
-
... More
Providing and fitting fixing of hermetically sealed compressor for replacement of defective one as per direction of the Engineer-in-charge. (With one year warranty)
-
-
-
... More
1.0 TR capacity High wall split type AC.
3
-
-
... More
1.5 TR capacity High wall split type AC.
10
-
-
... More
1.5 TR capacity window type AC.
3
-
-
... More
2.0 TR capacity High wall split and cassette type AC.
15
-
-
... More
2.5 TR capacity High wall split type AC.
2
-
-
... More
3.0 TR capacity High wall split and cassette type AC.
2
-
-
... More
4.0 TR capacity vertical split type AC.
1
-
-
... More
Providing and fitting fixing of hermetically sealed copper condenser unit for replacement of defective one as per direction of the Engineer-in-charge.
-
-
-
... More
1.0/1.5 TR capacity High wall split and window type AC.
5
-
-
... More
2.0/2.5 TR capacity High wall split and cassette type AC.
10
-
-
... More
3.0/4.0 TR capacity High wall split and vertical type AC.
2
-
-
... More
Providing and fitting fixing of ODU blower motor of AC systems after rewinding I/C necessary replacement of bush, shaft etc with complete varnishing as per direction of the Engineer-in-charge.
15
-
-
... More
Providing and fitting fixing of scroll motor (A.C type) of indoor unit split type AC system as per direction of the Engineer-in-charge.
10
-
-
... More
Providing and fitting fixing of scroll motor (D.C type) of indoor unit for inverter technology split type AC system as per direction of the Engineer-in-charge.
8
-
-
... More
Providing and fitting fixing of IDU swing motor of indoor unit split type AC system as per direction of the Engineer-in-charge.
5
-
-
... More
Providing and fitting fixing of inverter PCB circuit of Split type AC system for Indoor Unit complete. as per direction of the Engineer-in-charge.
-
-
-
... More
1.0/1.5/2.0/2.5/3.0 TR split type high wall AC.
20
-
-
... More
2.0/3.0 TR cassette type AC.
2
-
-
... More
Providing and fitting fixing of inverter PCB circuit of Split type AC system for outdoor Unit complete. as per direction of the Engineer-in-charge.
-
-
-
... More
1.0/1.5/2.0/2.5/3.0 TR split type high wall AC.
20
-
-
... More
Providing and fitting fixing of PCB circuit for non-inverter split type AC system with the same/universal PCB circuit as per direction of the Engineer-in-charge.
-
-
-
... More
1.0/1.5/2.0/2.5/3.0 TR split type high wall AC.
30
-
-
... More
Providing and fitting fixing of pump motor for cassette type AC system as per direction of the Engineer-in-charge.
3
-
-
... More
Supply, installation of additional length of copper pipe of appropriate size of (5/8" (15.88 mm), 1/4”(6.35 mm), 3/8” (9.53 mm) and 3/4”(19.05 mm) or nearest dia. as per manufacturer design for for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units for 1.0 / 1.5 / 2.0 /3.0 /4.0 TR split type high wall,cassette, vertical type ACs.
150
-
-
... More
Providing and fabrication of M.S platform for placement of condensing unit by using M.S angel of (50x50x5) mm or (65x65x5) mm size base plate, nuts & bolts/universal bracket (GSS) for ODU of split type AC system including all accessories for on-site installation i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-charge.
8
-
-
... More
Dismantling, Shifting and re-installation of 1.0/1.5/2.0/2.5/3.0 TR window, split and cassette, vertical type AC system as per direction of the Engineer-in-charge.
20
-
-
... More
Providing hard/ coil PVC pipe of good quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit to nearest disposal as per direction of the Engineer-in-charge
200
-
-
... More
Providing and fitting fixing of accessories during maintenance work of split/window AC as per direction of the Engineer-in-charge.
Capacitor
-
-
-
... More
2.0/2.5/4.0/5.0 µF
20
-
-
... More
25 µF
10
-
-
... More
36 µF
10
-
-
... More
45 µF
50
-
-
... More
(50-60) µF
35
-
-
... More
(80-120) µF
4
-
-
... More
Terminal Clip
200
-
-
... More
PVC tape (Black tap)
10
-
-
... More
Thermostat for split type AC system
10
-
-
... More
Thermostat for window type AC system
4
-
-
... More
Selector switch for window type AC system
6
-
-
... More
Relay for split type
2
-
-
... More
Relay for window type
2
-
-
... More
Contactor
25
-
-
... More
Coil sensor
10
-
-
... More
Room sensor
10
-
-
... More
Display with sensor
15
-
-
... More
Capillaries/ Dryer
8
-
-
... More
Nitral tape (Arrow tape)
10
-
-
... More
Remote with battery
40
-
-
... More
Connector
7
-
-
... More
Air Filter
7
-
-
... More
Single core copper wire 1.5/2.5 Sq.mm made of (Havels/Anchor)
25
-
-
... More
Supply and installation of additional length of electrical copper wire 4 sq mm size with casing size 01 (One) inch including other materials to connect outdoor unit with electrical panel as per direction of the Engineer-in-charge.
30
-
-
... More
Providing & fitting fixing of fan blade of outdoor unit of window, split, cassette and vertical type AC system as per direction of the Engineer-in-charge.
10
-
-
... More
Providing & charging of compressor oil with capillary complete as per direction of the Engineer-in-charge.
5
-
-
... More
Deployment of 3 (three) nos. technicians, one in each of 3(three) shifts, round the clock, 24 x7 basis during hot spell to attend complains related to AC machines installed at different locations of AGMC & GBP Hospital as per direction of the Engineer-in- Charge immediately as and when required on urgent basis for carrying out items of work under AMC.
250
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%