Public Works Department Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.

Public Works Department - PWD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date17 Aug 2024
Closing Date17 Sep 2024
Tender Amount₹ 9,19,84,968 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
EARTHWORK

-

-

-

... More
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site , spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per MoRD Technical Specification Clause 303.1.

3821.47

893459

233.8

... More
PROTECTION WORK (RETAINING WALL & TOE WALL)

-

-

-

... More
Excavation for Structures (A)Without Dewatering Earthwork in excavation for structures as per drawing and MoRD technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material. (I) Ordinary Soil (i) Upto 3 m depth

395.5

181218

458.2

... More
Filling in foundation trenches as per drawing & MoRD technical specification Clause 305.3.9, 1200. (i)Sand filling

91.5

114661

1253.13

... More
Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement) I. P.C.C grade M 10 (using jhama brick aggregate) (i) Nominal mix 1:3:6

91.5

850323

9293.15

... More
Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement) (ii) P.C.C grade M 15 (1:2.5:5 Nominal mix)

409.92

3897129

9507.05

... More
Providing weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7.

244

95696

392.2

... More
Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8.

175.68

824664

4694.13

... More
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202.

12.2

1120404

91836.42

... More
DRAINAGE WORK

-

-

-

... More
Surface Drains Construction of unlined surface drains of average cross-sectional area 0.40 sqm in ordinary soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3 m and lead of 50 m (average lead 25 m) as per MoRD Technical Specification Clause 307. (i) Surface Drains in Ordinary Soil (B) Mechanical Means

1920

42048

21.9

... More
Road side Pucca Drains Construction of road side pucca drain with M10 (1:3:6 with jhama brick aggregate) to specified lines, grades, levels and dimensions as per approved design and MoRD Technical Specification Clause 307, 1606. Excavated material to be used in embankment at site. (including centering, shuttering, etc. but excluding reinforcement) C. Trapezoidal drain (top clear width 600 mm, bottom clear width 300 mm and clear depth of 600 mm) (I) In ordinary Soil

930

3951570

4249

... More
Road side Pucca Drains Construction of road side pucca drain with M10 (1:3:6 with jhama brick aggregate) to specified lines, grades, levels and dimensions as per approved design and MoRD Technical Specification Clause 307, 1606. Excavated material to be used in embankment at site. (including centering, shuttering, etc. but excluding reinforcement) D. U shaped drain (top clear width 600 mm, bottom clear width 600 mm and clear depth of 600 mm) (I) In ordinary Soil

530

2597355

4900.67

... More
Providing & laying reinforced cement concrete in superstructure as per drawings & MoRD technical specifications Clauses 800, 900, 1205.4 & 1205.5 (including centering, shuttering, staging etc. but excluding reinforcement). II.R.C.C M 25 1.For height upto 5 m

106

1431304

13502.87

... More
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202.

7.42

694423

93588.12

... More
GRANULAR SUB_BASES, (Non-Bituminous) AND SHOULDERS.

-

-

-

... More
Granular Sub-base with Well Graded Material (Table 400.1) using Jhama Brick Aggregate (A) By Mix in Place Method Construction of granular sub-base by providing well graded material (Jhama Brick Aggregate, Grading-I, as per Table 400.1, spreading in uniform layers with tractor with attachments on prepared surface, mixing by mix in place method with rotavator at OMC, applying and brooming sand to fill up the interstices of coarse aggregate, watering and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Technical Specification Clause 401. (i) For Grading - I Material (jhama brick aggregate)

1437.44

6944526

4831.17

... More
Wet Mix Macadam Providing, laying, spreading and compacting stone aggregates to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed materials by tipper to site, laying in uniform layers in sub-base/ base course on a well prepared sub-base and compacting with smooth wheel roller of three wheel 80-100 kN static roller to proper grade and camber, achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and as per MoRD Technical Specification Clause 406. By Mechanical Means with 1.00 km lead

3580.34

24870044

6946.28

... More
Water Bound Macadam Sub-Base / Base using Jhama Brick Aggragate 2) WBM Grading - 3 Providing, laying, spreading and compacting jhama brick aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing rolling with three wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading- 3 as per MoRD Technical Specification Clause 405. (A) By Manual Means

156.25

1190151

7616.92

... More
BASES AND SURFACE COURSES(Bituminous)

-

-

-

... More
Prime Coat (ii) Medium porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.20 kg/sqm using mechanical means as per MoRD Technical Specification Clause 502.

23868.94

2189497

91.73

... More
Tack Coat (iii) Providing and applying tack coat with bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surface treated with primer & cleaned with Hydraulic broom as per MoRD Technical Specification Clause 503.

23868.94

563545

23.61

... More
Bituminous Macadam Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site upto a lead of 1000 m laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per MoRD Technical Specification Clause 504. i. With Viscosity Graded Bitumen of VG-30.

1193.44

19733745

16535.18

... More
25 mm thick Open-Graded Premix Carpet using Bituminous (Viscosity grade/ modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 25 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using Viscosity grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80 - 100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C or Type D as per MoRD Technical Specification Clause 508. Case - II By Mechanical Means (I) Bitumen of VG-30

23868.94

9753326

408.62

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A or Type B or Type C or Type D as per MoRD Technical Specification Clause 510. A. By Manual Means Case-II: Type- B i. Bitumen of VG-30

23868.94

2188781

91.7

... More
MISCELLANEOUS ITEMS FOR ROADS

-

-

-

... More
80 mm thick factory made c.c. interlocking paver block of M-35 Grade Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength, thickness & size/ shape, made by table vibratory method to attain superior smooth finish using PU or equivalent moulds, laid in required grey colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. all complete as per specifications & approval/ direction of the Engineer -in-Charge: (a) 80 mm thick c.c. paver block of M-35 grade with approved colour, design and pattern.

2083.31

3233297

1552

... More
Providing and laying factory made kerb stone Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete inposition to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-Charge (length of finished kerb edging shall be measured for payment). (Precast c.c. kerb stone shall be approved by Engineer-in-Charge).

25

317720

12708.8

... More
TRAFFIC SIGN, MARKINGS & OTHER ROAD APPURTANCES

-

-

-

... More
Traffic Signs (using jhama brick aggregate in CC/ PCC) A. Retro-reflectorised Traffic Signs 1) Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide MoRD technical specification Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete (using jhama brick aggregate) 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawings and MoRD Technical Specification Clause 801. (i) with 900 mm equilateral triangle aluminium sheeting

25

93192

3727.71

... More
Traffic Signs (using jhama brick aggregate in CC/ PCC) A. Retro-reflectorised Traffic Signs 1) Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide MoRD technical specification Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete (using jhama brick aggregate) 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawings and MoRD Technical Specification Clause 801. (iii)with 600 mm circular aluminium sheeting

25

91061

3642.47

... More
Direction and Place Identification signs upto 0.9 sqm size board (using jhama brick aggregate in CC / PCC) (B)Semi Reflective Traffic Signs Providing and erecting and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. sheet duly stove enameled paint in white colour in front and gray colour on back with red reflective border of 70 mm width and required message, letters and figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47 mm x 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete (using jhama brick aggregate) 450 mm x 450 mm x 600 mm, 600 mm bellow ground level as per approved drawings and MoRD Technical Specification Clause 1701.

26

118926

4574.1

... More
Kilometre Stone (with RCC M15 grade using jhama brick aggregate) Reinforced cement concrete M15 grade (using jhama brick aggregate) kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc. as per drawing and MoRD Technical Specification Clause 1703. (ii)Ordinary Kilometre Stone(precast)

6

22061

3676.87

... More
Boundary Pillar (with PCC M15 grade using jhama brick aggregate and reinforcement) Plain cement concrete M15 grade (using jhama brick aggregate and reinforcement) boundary pillar / local stone of standard design as per IRC:25 fixed in position including finishing and lettering but excluding painting as per drawing and MoRD Technical Specification Clause 1704.

22

19385

881.18

... More
Construction of RCC guide posts of 250 mm dia and total 600 mm long,(300 mm below GL) M15 grade (with jhama brick aggregate) cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and MoRD Technical Specification Clause 1401.6. (A) In Ordinary Soil

222

119502

538.3

... More
Road marking strips (retro-reflective) of specified shade/ colour using Hot Applied Thermoplastic material with Reflectorising Glass Beads on Bituminous Surface Providing and applying 2.5 mm thick thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic material including reflectorising glass beads @ 250 gms per sqm area by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater including cost of cleaning the road surface of all dirt, seals, oil, grease and foreign material etc, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes as per MoRT&H Technical Specification Clause 803.

1047.66

756305

721.9

... More
Providing and Fixing 'Citizens' Information Board' of the Project(with CC structure) Providing and fixing of typical Citizens' Information board with Logo as per MORD specifications and drawing with CC structure made with M-15 of Size 1150 mm in length, 300 mm in thickness and 2450 mm in height all above G.L. with foundation with M-15 concrete of size 1150 mm x 600 mm x 750 mm , 750 mm below ground level with skin reinforcemet with 8 mm dia TMT bars @ 200 cm C/C from bottom of the structure. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of structure will be painted with primer and two coats of epoxy paint as per drawing and MoRD technical specification Clause 1701 and Annexure 1700.1 (A) Board 'A'

1

23132

23132.78

... More
CROSS DRAINAGE STRUCTURES

-

-

-

... More
Excavation for Structures (A)Without Dewatering Earthwork in excavation for structures as per drawing and MoRD technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material. (I) Ordinary Soil (i) Upto 3 m depth

122.34

56056

458.2

... More
Backfilling behind abutment, wing wall & return wall complete as per drawings & MoRD technical specification Clause 1204.3.8. (i)Sandy material

11.84

19858

1677.23

... More
Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement) I. P.C.C grade M 10 (using jhama brick aggregate) (i) Nominal mix 1:3:6

17.77

165139

9293.15

... More
Providing concrete for plain/reinforced concrete in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement). II. P.C.C grade M 15 (i) Nominal mix 1:2.5:5

88.64

923953

10423.66

... More
Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement) (vi)R.C.C grade M-25 upto 5 m height

33.78

420045

12434.75

... More
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202.

5.85

537243

91836.42

... More
Providing & laying reinforced cement concrete in superstructure as per drawings & MoRD technical specifications Clauses 800, 900, 1205.4 & 1205.5 (including centering, shuttering, staging etc. but excluding reinforcement). II.R.C.C M 25 1.For height upto 5 m

17.78

240081

13502.87

... More
Supplying, fitting, & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in superstructure complete as per drawing & MoRD technical specifications Clauses 1002, 1010 & 1202.

1.95

182496

93588.12

... More
Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8.

36

168988

4694.13

... More
Providing weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7.

56

21963

392.2

... More
Providing and fixing in position Drainage spouts complete as per drawing & MoRD technical specifications Clause 1209.

10

20070

2007



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.