The Singareni Collieries Company Limited Tender

For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

The Singareni Collieries Company Limited - SCCL Tender

Works
Civil And Construction
Water Storage And Supply
Opening Date27 Dec 2024
Closing Soon20 Jan 2025
Tender Amount₹ 3,62,27,191 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Providing High Built Epoxy protective coating of SIKA/ BASF/ FOSROC to the exposed concrete surfaces of structures, 2 coats including all leads and lifts etc., complete for special repairs. Note: 1. The surface to be treated must be thoroughly cleaned in appropriate method. Remove all traces of form work, release agent, grease, or other contaminant that may prevent proper adhesion. 2. Rate quoted must take surface roughness in to account. No extra measurement / rate will be allowed on this account

1300

767

997100

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Plastering to brick masonry with cement mortar 1:4, 12mm thick including raking out of joints ( But Excluding Cost of Cement )

1100

149

164934

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Extra lift charges for RCC items including lift for centering / shuttering charges (Floor height = 3.66M) - For Columns - In 1st floor

40

689

27596

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Erecting companys steel stanchions, built up columns, trestles, beams, trusses, N girders, chequered plate walk way etc., with contractors tackle, derric, crane etc., complete

5

10225

51127

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Fabrication of structural steel components like stanchions, built up columns, trestles, beams, trusses, N girders, chequered plate walk way etc., including all leads and lifts at site etc., with companys steel sections but with contractors welding rods, bolts, rivets and all contingencies, power charges, etc., complete as per drawings and instructions of the Engineer in charge.

5

18178

90892

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and fixing of 230 V , 10-60 Amps Single phase Electronic Programmable Energy Meters mounted on floor mounted MV metering panel. Note 1: A.C Single phase,2 wire solid state(static) fully electronic energy meter, Accuracy class 1.0 & Current rating 10-60 Amps with LCD Display for 240Volt system fitted with pilfer proof meter box. All meters having radio Frequency module to read AMR and data logs etc., at anytime from anywhere through Data Concentrator Unit(DCU). Soft ware communication Compatibility/Communication port: The tenderer shall supply software compatible for AMR solution. The software should be able to collect data from RF energy meters through DCU and should be available for on demand data viewing and down loading/viewing consumption reports. Data should include parameters like voltage, current, power factor, frequency, power and cumulative energy. Report generation format should in accordance with SCCLs requirement. Supplier should also supply software for CMRI(At least for Analogic & SANDS make) and should be compatible to micro soft windows systems. The supplier shall provide meter reading protocols. Make of Energy Meter: SCHNIDER ELECTRIC India Private Limited. (Formerly L&T Electrical & Automation).

3

5228

15685.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and fixing of 8Way SPN distribution board concealed in wall with din rail suitable for any combination of single pole outgoing MCB s in sheet steel enclosure on wall with 1 no 32A, 2pole 100mA ELCB and 6 NOs of 6-32 Amps Single pole MCBs including connections, all masonry work complete

3

7657

22973.1

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and laying of 3 runs of 2.5 sq.mm 1100 v grade PVC insulated flexible copper cable ( Phase, Neutral &Earth) in existing metallic / Non - Metallic conduit pipe for run of circuit / Power mains including copper lugs complete

1100

157

173360

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and laying of 3 runs of 4 sq.mm 1100 v grade PVC insulated flexible copper cable ( Phase, Neutral & Earth) in existing metallic / Non -Metallic conduit pipe for run of circuit/power mains including copper lugs complete

40

205

8212

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and Wiring with 3 Runs of 1.0Sq.mm 1100 V grade PVC insulated flexible copper conductor cable (phase, neutral & earth ) in the existing P.V.C conduit pipe with MODULAR Type 6A ISI marked MODULAR Type bell push with GI Box with appropriate white cover plate including supply and suitable mounted DING DONG Bell of approved make and type, mounting for Bell etc., complete with all accessories as needed. (MDS Type)

4

1109

4439.2

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Providing independent earthing for Important equipment with 40mm dia B class 2.5m long G.I pipe and 40mm dia B class 2.5 m long G.I pipe and 19mm dia B class G.I pipe of 0.3mtr. long connected with reducer providing G.I funnel with mesh enclosed in C.C./Brick masnory Chamber of 450mm X 450mm X 400mm with R.C.C. Slab cover duly providing staggered holes filling with 20Kg salt and 40Kg charcoal or or 40Kg bentonite powder from the bottom of the pipe giving earth connection from electrode through G.I strip of 40mm X 6mm X 200mm length with all accessories and labour charges complete as per IS specifications 732/1982 9Part II) Note:Whenever providing full length of electrode is not possible due to obstruction of water tube/rock, the length of electrode may be reduced and additional earthing may be done to meet earth resistance

14

5525

77351.4

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and fixing of ISI marked MODULAR Type 6A 5 pin MODULAR Type wall plug socket with MODULAR TYPE type 6A switch control on a common board with earth continuity including GI Box and White Front plate including wire leads earth connections complete

53

240

12720

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and Wiring with three runs of 1.0 sq.mm (14/0.3mm) 1100 V grade PVC insulated flexible copper conductor cable (phase,nuetral & earth) in the existing P.V.C conduit pipe with 6A flush type ISI marked MODULAR type Control switch, MODULAR 120W step Type electronic hum free fan regulator, GI Box and white Front plate concealed in wall complete for fan pont ( MDS Type).

25

1579

39490

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and Wiring with three runs of 1.0 sq.mm (14/0.3mm) 1100 V grade P.V.C insulated flexible copper conductor cable (phase, neutral & earth) in the existing P.V.C conduit pipe with 6A flush type ISI marked MODULAR type switch/bell push with GI box and white front plate concealed in wall and ceiling Rose/Slant accessories as necessary complete for light , bell, exhaust fan points(MDS Type).

72

1019

73425.6

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and fixing of 25mm dia, heavy guage recessed/concealed ISI marked PVC conduit pipe along with reinforcement laid into wall/slab with all required accessories wherever necessary including masonry work for circuit main/sub-mains/15 A power circuit/Telephone/TV points complete

350

105

36855

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and fixing of 19mm dia, heavy guage ISI marked PVC conduit pipe recessed / concealed into wall / slab along with reinforcement laid into wall / slab with all required accessories wherever necessary including masonry work for light fan point /exhaust fan point / call bell point and separate plug socket point, TV / Telephone wiring etc. complete

350

94

33005

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Conveyance charges of CEMENT including loading, unloading and stacking charges for 5 KM lead.

774

276

213778.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Conveyance charges of Steel including loading, unloading and stacking charges for 5 KM lead.

100

317

31772

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Conveyance charges of Earth for 2 KM lead.

3000

56

169800

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Providing 2000 Litres capacity circular RCC Over Head Tank having 1.60m inner dia, 1.20m Inner height, 75mm thick Side walls and 100mm thick bottom slab using M-20 design mix Concrete corresponding to IS 456, 20mm down size (65% of 20-10mm & 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including centering and shuttering charges, cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, etc. 75mm thick top cover shall be made up of 3 Nos. pieces of RCC precast slabs of M20 grade concrete, plastering of inside walls & bottom of tank using CM 1:4, 12mm thick including rendering the surfaces smooth. all internal surfaces shall be painted using two component acrylic polymer modified elastomeric waterproofing membrane which consists of Brush bond powder and Brush bond liquid acrylic emulsion with a minimum of 2mm thickness coating. finished item of work. Tank shall be placed over 9 Nos of precast PCC 1:2:4 Pedastals each of size 300mm x 300mm x 300mm. (Cost is exclusive of cost of cement, reinforcement steel and its fabrication charges.) (CA : 0.90 Cum, FA:0.45Cum) Cement @ 350Kg/Cum of concrete is to be used.

1

18011

18011.2

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying and fixing of 15 mm brass body CP finish two way bib tap of not less than 400 grams weight with quarter turn spindle internal/ external threaded connection conforming to IS 8931

2

1015

2031

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying and fixing Gunmetal Gate valve as per IS-778 Class- I, Indian make heavy type - 50mm NB Size

1

4319

4319.5

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying and fixing Gunmetal Gate valve as per IS - 778 Class - I, Indian make heavy type - 25mm NB Size

2

1441

2882.6

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and Fixing 15 mm CP concealed stop Valve not less than 400 grams weight quarter turn spindle conforming to IS 8931

7

728

5096

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying and fixing of Stainless steel finish Health Faucet with 1m long tube, faucet gun and wall hook

2

567

1134.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying and fixing TV shape mirror with plastic frame size 609.6x457.2mm

3

610

1832.7

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and fixing of 15 mm brass body CP finish bib Cock of not less than 400 grams weight screw type (full turn) with internal / external threaded connection conforming to IS 8931

3

335

1006.5

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying and Fixing white glazed flat back Bowl urinals of size 440x265x315mm with internal flushing rim fixed with screws complete Indian make conforming to IS:2556-1995

2

1186

2373.6

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying and Fixing Indian make Flat Back Wash Hand Basin 1st quality conforming to IS: 2556 - Part-4:1972 with waste fittings like 32mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400grams Seiko/Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550x400mm - Single C.P. Pillar Cock

3

2533

7601.4

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying and fixing 580 x 440mm Orissa pan white glazed W.C first quality ISI marked conforming to IS 2556 - part 3- 2004 with P or S trap

1

2399

2399.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and fixing best Indian make plastic seat and lid for European water closets with rubber or plastic Buffers as per IS 2548-1996

2

1369

2738.6

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying and fixing wash down European water closet of first quality conforming to IS 2556-Part-2-2004 of white glazed with P trap. Plastic seat and lid is to be paid extra.

2

2118

4237.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying and fixing 50.8cm dia C.I Man hole frame and cover for 914.4mm dia chamber (Medium weight) as per IS:1726- 40 Kgs

4

3538

14153.2

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying and fixing 150mm x100mm SWG gully traps Conforming to IS- 651 and 4127 with C.I Grating and Constg. Brick masonry in CM 1:6 prop. including plastering and fitted with 304.8mm x288.6mm(12 Inchesx9 Inches) C.I Frame and hinged cover including earth work excavation (excluding cost of Cement)

3

618

1854.3

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Extra depth of 450mm x 450mm Inspection Chamber beyond 450mm depth (Excluding cost of cement) Extra for every 0.100m (100mm) depth

4

462

1848.24

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Construction of 450mm x 450mm and 450mm depth Inspection Chamber with CC 1:4:8 base of 150mm thick 40 mm Crushed Granite metal and 225 mm thick Brick masonary walls in CM 1:6 with fly ash bricks of size 225 x 100 x 60mm with 50kg/Sq. Cm Compressive strength and plastering with CM 1:4; 12mm thick including rendering the surfaces smooth both inside and outside and channelling to required slope including supply and fixing precast RCC 1:2:4 cover of 50mm thick and 600 X 600mm size with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal, including earthwork excavation to the required depth etc; complete for finished item of work (but excluding cost of cement steel and its fabrication charges.)

2

3110

6220.08

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Extra depth of Circular Man Hole of Size 900mm dia( Excluding Rock cutting) beyond 450mm depth (Excluding cost of cement) Extra for every 0.100m(100mm) depth

25

680

17022

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Construction of 900mm dia and 450mm depth circular manhole with CC 1:4:8 base of 150mm thick with 40 mm Crushed Granite metal, 225mm thick Brick masonry walls in C.M 1:6 with Flyash bricks of size 225X100x60mm and having compressive strength of 50 kg/sqcm, plastering with CM 1:4,12mm thick including rendering the surfaces smooth both inside and outside and benching with 100mm thick CC 1:2:4 with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal and channelling to required slope including supply and fixing precast RCC 1:2:4 cover of 50mm thick and 600mm dia using 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal, including earth work excavation to the required depth etc. complete for finished item of work (but excluding cost of cement, steel and its fabrication charges.)

5

4635

23176.3

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying, laying, jointing RCC NP2 hume pipes (socket and spigot) confirming to IS 458/2003, with necessary rubber rings (as per IS 5382/1985) cost and conveyance of all materials to site, labour charges, all operational charges etc complete as directed for finished item of Work For 150mm dia Pipes. NOTE:- Transportation of pipes includes up to 5 KM from Factory. For any extra lead, necessary extra lead charges may be added.

40

454

18196

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and Fixing of CPVC Pipes along with Fittings to meet the requirement of ASTM-D 2846 etc., complete - For 22.20mm OD Pipe - SDR 11

30

230

6906

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and Fixing of CPVC Pipes along with Fittings to meet the requirement of ASTM-D 2846 etc., complete - For 28.60mm OD Pipe - SDR 11

30

273

8202

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and Fixing of CPVC Pipes along with Fittings to meet the requirement of ASTM-D 2846 etc., complete - For 54.00mm OD Pipe - SDR 11

25

665

16625

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply of Prince/Sudhakar/ Kisan/ Supreme or any ISI Brand UPVC / SWR Traps ( as per ISI- standards ) - For 4 Inches(101.6mm) Nahani Trap (With Jali with inlet)

5

170

852

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply of Prince/Sudhakar/ Kisan/ Supreme or any ISI Brand UPVC/ SWR Pipe (as per ISI- standards) fittings like bends, tees, Ys, etc., For Vent Cowl - 110mm dia

2

23

47.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply of Prince/Sudhakar/ Kisan/ Supreme or any ISI Brand UPVC/ SWR Pipe (as per ISI- standards) fittings like bends, tees, Ys, etc., For Vent Cowl - 75mm dia

2

18

36.4

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply of Prince/Sudhakar/ Kisan/ Supreme or any ISI Brand UPVC/ SWR Pipe (as per ISI- standards) fittings like bends, tees, Ys, etc., For Single Tee (With Door) - 110mm dia

2

161

322.6

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply of Prince/Sudhakar/ Kisan/ Supreme or any ISI Brand UPVC/ SWR Pipe (as per ISI- standards) fittings like bends, tees, Ys, etc., For Single Tee (With Door)- 75mm dia

2

90

181.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply of Prince/Sudhakar/ Kisan/ Supreme or any ISI Brand UPVC/ SWR Pipe (as per ISI- standards) fittings like bends, tees, Ys, etc., For Plain Bend 87.5 degrees.- 75mm dia

15

62

937.5

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply of Prince/Sudhakar/ Kisan/ Supreme or any ISI Brand UPVC/ SWR Pipe (as per ISI- standards) fittings like bends, tees, Ys, etc., For Plain Bend 87.5 degrees.- 110mm dia

15

104

1567.5

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying, laying, fixing and commissioning the SWR pipes of Prince/Sudhakar/ Kisan/ Supreme or any ISI Brand SWR Pipe (as per ISI- standards) Type-A pipes (PVC / SWR pipe - 4Kg/sq.cm) for rain water and vent pipes of any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice excluding cost of fittings - For 110mm dia 3M Single socket pipe

4

958

3834.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying, laying, fixing and commissioning the SWR pipes of Prince/Sudhakar/ Kisan/ Supreme or any ISI Brand SWR Pipe (as per ISI- standards) Type-A pipes (PVC / SWR pipe - 4Kg/sq.cm) for rain water and vent pipes of any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice excluding cost of fittings - For 75mm dia 3M Single socket pipe

6

675

4054.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Manufacture, Supply and delivery of DI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG-40/ SG-400/15 or GGG-50/SG-500/7 or equivalent grade as per I.S.3896-part2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-89/IS14846-2000/DIN 3202 F 4. All the valves should be with Electrostatic powder coating both inside and outside pocket less body passage. Drilled as per requirement of the dept. - PN-1.0 and 1.6 - For 600 mm Dia (With By-pass and Gear)

3

617600

1852802.7

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply of MS Machine end pair (Socket+Spigot) for PSC Pipelines including conveyance to site, including fixing charges Complete. (But Excluding GST) - For 600mm Dia

8

20954

167632

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying, Laying and Jointing of M.S Pipes Conforming to IS 3589/ 2001 including in lining with Cement mortar (1:2)-15mm thick using 4 numbers of 6mm dia M.S. Rings at Each end of the pipe and Out coating cement mortar (1:3) 30mm thick by shotcreting or GUniting duly providing wire mesh of size 50x50x3mm including cost of site welding, jointing materials and Hydrostatic pressure filed test. Rate is inclusive of Transportation to site of work, But Excluding GST - For 600mm Dia , 8.00mm thick

350

15722

5502945

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying and fixing of CI D/F Sluice valves conforming to IS 14846 /2000 with amendments No. 1and2 heavy duty with CI grade FG 260 as per IS: 210. Two coats of primer suitable for EPOXY PAINTS finish shall be applied to all metal surface and finally two coats of Epoxy Paint. The Valves shall be tested for (closed end Test) against Hydrostatic test requirement. The operation can be done with hand wheel / cap. The rates are including transportation and including cost of bolts, nuts, rubber insertion etc., complete. ISI Marked. - PN-1.6 For 300 mm Dia

22

57580

1266764.4

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Conveyance of Ductile Iron Pressure Pipes and accessories including loading at Factory, un-loading at site and stacking - For 350mm Dia (K9)

63000

1

70560

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply of Centrifugally cast (spun) ductile iron fittings conforming to IS:9523/2000 having dimensions as per table. The rates mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/ IS 9523/2000) - For Up to 500mm Dia pipe line

2200

119

262460

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying, laying and Jointing of Centrifugally cast (spun) ductile iron pressure pipes for water, gas and sewage with socket and spigot ends conforming to IS: 8329/ 2000 in standard working lengths of 4, 5, 5.5 and 6 metre with push-on-joint (rubber gasket D jointing) with cement mortar lining inside the pipes, with outside zinc coating carefully into trenches and laying them true to alignment and gradient, including the cost of the gasket, testing to required pressure, etc. complete. (Reference to specifications. BIS No. 3114/94/ 12288:1987) Rates are Excluding GST and cost of specials and including transportation K9 Pipe- For 350mm Dia

88

5858

515548

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply, Fabrication and Erection of Stainless steel tubes and Sections for hand railing, ladders, etc., including cost and conveyance of all materials to site, labour charges, all operational charges and including all materials like Stainless Steel Tubes, sections, plates, sheets and pipes, welding rods, bolts, rivets and all contingencies, power charges, tackle, derric, crane etc., leads and lifts at site etc., complete as per drawings and instructions of the Engineer in charge.

1200

653

783960

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Erection of compound wall gates, MS fencing posts on ground or on top of compound wall, cattle trap , MS holding down bolts, templates, in position etc., complete

2000

8

16000

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Fabrication of steel works like compound wall gates, MS fencing posts on ground or on top of compound wall, cattle trap , MS holding down bolts, templates, in position etc., complete including cost of welding rods, power charges etc., complete.

2000

18

36400

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Labour Charges for Fixing of window grills, compound wall grills, Iron Doors, windows, Verandah grils, and window guard bars in position etc., complete.

3250

5

18525

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Labour Charges for Fabrication of steel works like window grills, compound wall grills, Iron Doors, windows, Verandah grils and window guard bars including cost of welding rods, power charges etc., ( Excluding cost of fixing in position)

3250

34

110825

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Providing Superior quality wall care putty 2 coats for internal / external walls complete for finished Item of work.

280

119

33488

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Acrylic exterior emulsion Painting to New walls with Grade-II i.e., Ace or equivalent paint of Approved Make 2 coats over a base coat of Grade -II primer (making 3 coats in all) complete for finished Item of work -For External Walls

3000

167

502200

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Plastic emulsion Painting to New Internal walls with paint of Approved Make with 2 coats over a base coat of Grade -1 primer (making 3 coats in all) complete for finished Item of work - For Internal Walls

280

142

39984

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Whiting to New ceiling with Surya cem / Equivalent Cem, two coats complete for finished item of work.

775

43

33557.5

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;White washing to New walls with Surya Cem / Equivalent Cem two coats complete for finished item of work.

4000

39

157200

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Painting to Iron work with two coats of synthetic enamel paint of grade II of Approved Make and shade including a base Coat of Red oxide primer paint of grade -I of Approved Make making 3 coats - To new work -all complete for finished item of work.

500

170

85400

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying and fixing of Unplasticised Poly Vinyl Chloride (UPVC) 3 track sliding windows with mesh shutter â?? (2-glass shutters and 1-mesh shutter) duly manufactured using UPVC reinforced profiles (Composition of profile shall consists a minimum of 5.5 PHR of TiO2 and not more than 12 PHR of CaCo3 for every 100 parts of PVC resin) of (94 x 45mm)/(80x 52mm) x 2.20mm for outer frames, (58x 39mm)/(54x 38mm) x 2.20mm for sliding shutter frames capable of mounting single glazing system structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.0/1.2mm prefabricated and welded through fusion welding. The window sash shall be fitted with 5 mm thick clear float glass of reputed make and mesh shutter frame shall be (42x 25mm)/(52x 21.5mm) x 2.0mm fitted with Vinyl Coated Fiber mesh- on rollers/ pulley duly fixed with Grey colour TPV Gasket for sash and Glazing bead shall be co-extruded with Grey colour soft PVC. System shall have single point locking with Touch Lock and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site complete for finished item of work.

7.5

8088

60662.25

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and fixing of Bed room cupboard using Teak wood frames and Teak Veneered Decorative Plywood conforming to IS:1328 shutters as per the approved Drawing with the following components. 1). The frame is of size 100mm x 30mm with Teak wood. The frame is fixed to the wall by means of screws of size 100mm. 2). The openable shutters are made of 9 Ply - 12 mm thick Both sides Teak Veneered Decorative Plywood conforming to IS:1328 Shutters are to be fixed to the frame by means of heavy duty MS Powder coated piano hinges. 3). Sliding shutters are made of 5 Ply - 9 mm thick one side Teak Veneered Decorative Plywood conforming to IS:1328. Shutters are to be fitted in the Aluminium track of size 32mm x 6mm by using nickle coated sliding rollers of suitable size. 4). The cost is inclusive of M.S. Powder coated Piano hinges (IS 3818), nickle coated sliding rollers, Magnetic catches, Hasp and Staple 2 Nos, Aluminium anodised tower bolts (IS 204), handles (IS 208), etc., complete.

21

4276

89812.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, and 15mm x 15mm for top and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC â??Câ?? channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail and bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles and rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the â??Câ?? Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturerâ??s specification and drawing for finished item of work including the Following Aluminium anodised fittings complete.: Single Shutter as per Approved Make a) 1no.of 200mm long aldrop with 16mm dia shoot. b) 2 nos. 200 to 250mm mm long tower bolt with 10mm dia shoot. c) 2 no. 100 mm to 150 mm long grip handle. d) 3 nos.150 mm long butt hinges.

5.5

3295

18123.05

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Providing and fixing PVC Door Frame of the size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2Nos. of 150mm long brackets of 15x15mm M.S square tube. The two vertical door profiles are to be reinforced with 19x19mm MS Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long MS screws through the frame by using PVC fasteners. A minimum of 4Nos. of screws to be provided for Each vertical member and minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-charge for finished item of work as per Approved Make

22

357

7873.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and fixing Flush door shutters, solid bond wood block board type with teak ply on both faces.: 30 mm thick conforming to IS:2202 as per Approved Make including the following Aluminium anodised fittings : conforming to relevant IS standards : Single Shutter a) 3 nos. 150 mm long butt hinges. b) 2 nos. 200 mm to 250 mm long tower bolt with 10mm dia shoot. ; c) 1 no. 300mm long aldrop with 16mm dia shoot. d) 2 no. 100 mm to 150 mm long grip handle. e) 1 no. foot door stopper.

6.25

3543

22148.12

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and fixing Door frame of 125 x62mm with Medium teak wood including supply and fixing with 6nos. M.S.Z type hold fasts made out of 50x3mm M.S. flat 300mm long in CC beds, etc., complete. (Excluding Cost of Bed Blocks.)

24

1080

25936.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Flooring with Nano polished /stain free vitrified tiles screen printed of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:15622-2017, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, set over base coat of cement mortar (1:6), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm and jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost and conveyance of all materials, labour charges etc., complete for finished item of work, (But Excluding Cost of Cement ) Note :- The same rate is applicable for Skirting / Risers

70

1001

70130.9

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Providing Dadooing to walls with ceramic wall tiles of size 200x300mm / 245mm x 325 mm and thickness 6 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, set over base coat of CM (1:3) 12 mm thick with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointed with white cement paste mixed with pigment of matching shade to full depth, including cost and conveyance of all materials, labour charges etc., complete for finished item of work,( But Excluding Cost of Cement )

55

694

38173.85

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Flooring with Non-skid Ceramic floor tiles of size 400 x 400 mm and thickness between 7-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, set over base coat of cement mortar (1:6), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per Sqm and jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost and conveyance of all materials, labour charges etc., complete for finished item of work, (But Excluding Cost of Cement )

105

862

90538.35

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Providing plinth protection work with 50mm thick CC 1:3:6 using 20mm Down size (65% of 20-10mm and 35% of 10 - 4.75mm) graded Crushed granite metal together with a bed of 75mm thick CC 1:5:10 using 40mm Crushed granite metal well rammed, consolidated including finishing the top smooth duly maintaining the required slopes to drain off water as per site conditions including cost and conveyance of all materials to site of work, all labour, operational, and incidental charges and necessary side support for concrete while laying etc., complete for finished item of work (to a total thickness of 125mm). ( But Excluding Cost of Cement ) using Machine mixing

175

598

104804

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Flooring 50 mm thick with CC 1:2:4 using 20mm Down size (65% of 20-10mm and 35% of 10 - 4.75mm) graded crushed granite metal of approved hard quality on existing concrete base, rendering smooth complete. (But Excluding Cost of Cement )

1000

323

323700

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Flooring 30mm thick with CC 1:2:4 using 10mm size crushed granite metal of approved hard quality on existing concrete base, rendering smooth complete. ( But Excluding Cost of Cement )

150

245

36828

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply and fixing minimum of 25mm to 30mm thick polished Black Kadapa single slab of required size as directed by the Engineer-in-charge with exposed faces square cut and well polished, on existing Walls, with grey Cement Slurry of honey like consistency spread at the rate of 3.30Kg./Sqm. including cost and conveyance all materials and water to work site and all operational, incidental, labour charges, dressing and fixing of stones in position rubbing curing etc., complete for Shelves as directed (But Excluding Cost of Cement)

20

370

7412

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Providing impervious coat 12 mm thick for Brick/CC/RCC walls etc., with CM1:3, mixed with Approved Make of water proofing compound at the rate of 1Kg per bag of cement and rendering smooth, rounding off junctions of walls as directed including cost and conveyance of all materials and water etc., and operational , incidental, Labour charges etc., ( But Excluding Cost of Cement ) complete for finished item of work.

1500

153

230310

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Brushing of existing concrete surface with wire brush and providing cement concrete 1:2:4 screed of an average thickness of 20mm using 6mm size crushed granite metal of approved hard quality, and providing 2 layers of 24 guage rabbit wire mesh in the CC screed as nominal reinforcement and plastering with CM 1:4, 12mm thick including admixing of approved impervious water proofing compound as per manufacturers specification or @ 2% by weight of cement and finishing smooth and including providing slopes to drain off water etc., complete as directed (But Excluding Cost of Cement )

2200

298

655644

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Add Extra for Cornice / Raised Surfaces

55

225

12413.5

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supplying and fixing Gyp Board Suspended regular single layer false ceiling (GS-MFSC-4.1as per India Gypsum) using 12.5mm thick Gyp Board conforming to IS 2095-1993 fixing to Gyp steel GI perimeter channels of size 20mm x27mm x30mm(web) of 0.55mm thick screws fixed to brick work/ partition at 610mm c/c and suspending the frame work using Intermediate channels (45mm x15mm x15mm x0.9mm) from soffit at 1220mm c/c with ceiling angle (25mm x10mm x0.55mm) fixed with GI Cleat and steel expansion fasteners and connecting clip to the ceiling channels (with knurled web of 51.5mm x26mm x10.5mm x0.55mm) fixed in direction perpendicular to the intermediate channel at 457mm c/c and fixing the 12.5mm tapered edge Gypboard with 25mm drywall screws at 230mm c/c and jointing and finishing using joint compound and paper tape to have a flush look including filling the tapered and square edges with jointing compound, two coats of drywall topcoat complete for finished item of work as per India Gypsum Ltd specification. - For Flat Surfaces

60

1118

67110

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Providing gultha in CM 1:6, 20 mm thick and 150 mm wide including necessary scraping of wall and finishing the surface as directed ( But Excluding Cost of Cement )

165

33

5552.25

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;20 mm thick plain cement mortar bands in cement mortar 1:4 up to 300 mm in width for elevations and drip moulds etc.,- Raised Band (But Excluding Cost of Cement )

410

596

244519.9

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Plastering to Ceiling with cement mortar 1:3, 12mm thick ( But Excluding Cost of Cement )

2700

163

442368

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Plastering to brick / stone masonry with cement mortar 1:6, 20 mm thick in two coats including raking out of joints for walls only ( But Excluding Cost of Cement )

1000

313

313770

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Plastering to brick masonry with cement mortar 1:6, 12mm thick including raking out of joints ( But Excluding Cost of Cement )

1600

149

239904

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Flyash Brick masonry with bricks of size 225x100 x60 mm with 50kg /cm2 Compressive strength in C.M.1:4 for superstructure including scaffolding etc., (But Excluding Cost of Cement ) complete. For 100mm walls

100

831

83182

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Flyash Brick masonry with solid blocks of size 290x225x140mm with 50kg/cm2 Compressive strength in C.M.1:6 for superstructure including scaffolding etc., (But Excluding Cost of Cement ) complete.

190

5919

1124708.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Providing and fixing of RCC 1:2:4 precast shelves 25mm thick with 6mm dia MS reinforcement at 125mm c/c both ways with 10mm size crushed granite metal of approved hard quality without brackets, including necessary centering charges and plastering with CM 1:3, 12mm thick etc., but excluding cost of steel and Cost of Cement) complete as directed.(Cost of Fabrication of Reinforcement included)

24

314

7536.96

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Providing and fixing of RCC 1:2:4 precast shelves 37mm thick with 6mm dia MS reinforcement at 125mm C/C both ways with 10mm size crushed granite metal of approved hard quality (without brackets) including necessary centering charges and plastering with CM 1:3, 12mm thick etc.,(but excluding cost of steel and Cost of Cement)complete as directed.(Cost of Fabrication of Reinforcement included)

7

363

2543.31

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Reinforced Cement Concrete 1:2:4 with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded crushed granite metal of approved hard quality for precast RCC slabs, purlins, verandah posts, fencing posts etc. including machine mixing of Concrete, necessary shuttering, finishing etc including hoisting/fixing, cost and conveyance of all materials to work site, all labour charges, all operational incidental charges (excluding cost of steel and its fabrication charges and cost of cement) etc., complete for finished item of work, as directed. (CA : 0.90 Cum, FA:0.45Cum)

1.5

6986

10479.7

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Labour charges for cutting, bending and binding reinforcement with contractors binding wire, and placing in position as directed by Engineer - in - charge including all leads, etc., complete

90

13984

1258596

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Reinforced Cement Concrete M-30 design mix Concrete corresponding to IS 456 using Concrete Mixer with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/ shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum). Cement @ 400Kg/Cum of concrete is to be used. - For roof Slabs - up to 150mm thick.

240

8453

2028832.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Reinforced Cement Concrete M-30 design mix Concrete corresponding to IS 456 using Concrete Mixer with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/ shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum). Cement @ 400Kg/Cum of concrete is to be used. - For roof Beams.

55

9788

538393.35

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Reinforced Cement Concrete M-30 design mix Concrete corresponding to IS 456 using Concrete Mixer with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/ shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum). Cement @ 400Kg/Cum of concrete is to be used. - For Column.

40

10516

420654.8

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Reinforced Cement Concrete M-30 design mix Concrete corresponding to IS 456 using Concrete Mixer with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/ shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum). Cement @ 400Kg/Cum of concrete is to be used. - For Column Footings / Raft.

450

7209

3244486.5

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Reinforced Cement Concrete M-20 design mix Concrete corresponding to IS 456 using Concrete Mixer with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/ shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum). Cement @ 350Kg/Cum of concrete is to be used. - For roof Slab - up to 150mm thick.

85

8453

718544.95

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Reinforced Cement Concrete M-20 design mix Concrete corresponding to IS 456 using Concrete Mixer with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/ shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum). Cement @ 350Kg/Cum of concrete is to be used. - For roof Beams.

24

9788

234935.28

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Reinforced Cement Concrete M-20 design mix Concrete corresponding to IS 456 using Concrete Mixer with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/ shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum). Cement @ 350Kg/Cum of concrete is to be used. - For Sunshades.

7

14879

104157.69

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Reinforced Cement Concrete M-20 design mix Concrete corresponding to IS 456 using Concrete Mixer with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/ shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum). Cement @ 350Kg/Cum of concrete is to be used. - For Lintels.

11

10494

115438.07

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Reinforced Cement Concrete M-20 design mix Concrete corresponding to IS 456 using Concrete Mixer with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/ shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum). Cement @ 350Kg/Cum of concrete is to be used. - For Plinth Beams / Brace beams.

24

9911

237865.68

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Reinforced Cement Concrete M-20 design mix Concrete corresponding to IS 456 using Concrete Mixer with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/ shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum). Cement @ 350Kg/Cum of concrete is to be used. - For Columns.

35

10516

368072.95

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Reinforced Cement Concrete M-20 design mix Concrete corresponding to IS 456 using Concrete Mixer with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/ shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum). Cement @ 350Kg/Cum of concrete is to be used. - For Column Footings / Raft.

29

7209

209089.13

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Cement Concrete 1:2:4 with 20mm down size (65% of 20-10mm and 35% of 10-4.75mm) graded Crushed Granite metal of approved hard quality inclusive of shuttering/centering charges for bed blocks, encasing joists/ rails, holdfasts of doors and windows, etc. Complete (But Excluding Cost of Cement) - with concrete mixer (CA : 0.90 Cum, FA:0.45Cum)

60

4855

291334.2

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Add Extra for shuttering and centring charges for CC - Basement / Sidewalls, Water Tank Walls

1100

393

432410

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Cement Concrete 1:3:6 with 40mm down size (50% of 40-20mm, 30% of 20-10mm and 20% of 10-4.75mm) graded Crushed Granite metal of approved hard quality including machine mixing, vibrating, etc., Complete for finished Item of work as directed for Side Walls of Drains or Basement/ Substructure of the Buildings (Excluding Cost of Cement, Centering and shuttering charges) (CA : 0.90 Cum, FA:0.45Cum)

575

3710

2133807.75

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Cement Concrete 1:4:8 with 40 mm size Crushed granite metal of approved hard quality in foundations or Plinths etc., Complete (But Excluding Cost of Cement) - with concrete mixer

180

3667

660216.6

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Supply of Hard broken stone of granite, free from dust obtained by quarrying, wedging, breaking, burning, splitting, and blasting - Stone chips 2.36mm and below size crushed metal

301

1546

465556.7

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Clearing light jungle / Shrub jungle

5000

3

19000

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Filling with excavated earth (excluding rock)/ Sand in trenches, sides of foundations and basement with initial lead in layers not exceeding 15 cm thick, consolidating Each deposited layer by watering and ramming including cost and conveyance of water to work site and all operational, incidental, labour charges, hire charges of T and P etc., complete for finished item of work. (APSS NO. 309 and 310) (Excluding cost of sand) - by Manual Means

2270

34

78315

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Earthwork excavation by machinery where Mass excavation with large quantity is involved for buildings, major pipe line works, etc., in all soils up to SDR and stone matrix including cutting and loading in tippers with all lifts etc., complete

8000

68

544800

... More
Construction of Ground Level Storage Reservoir Pump house Electrical sub station Office rooms store;Earth work excavation for foundations and depositing on bank for all lifts and with an initial lead up to 50m including all operational, incidental, labour charges such as shoring, sheeting, planking, strutting, etc. complete for finished item of work as per SS - 20 B (APSS 308) - Ordinary Soil-Manual Means -Up to 3 m depth

1000

243

243200



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.