Military Engineer Services Tender

For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date26 Jun 2024
Closing Date3 Sep 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIRS / MAINT OF EXTERNAL SERVICES (ES and WS) INCLUDING BUILDING INTERNAL SERVICES AT YEDDUMAILARAM UNDER GE GOLCONDA
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sqmm multistrand copper conductor cable PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 1.50 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable ( green colour) as earth lead in and including PVC rigid conduit with all fittings for concealed type on stone / brick, masonary walls, roof etc including new CI/MS sunken box of required size and all as directed by Engineer-in-Charge & 3 mm thick plastic laminated sheet for housing switches sockets, regulators etc. including cutting/running chases, pinning in and making good the disturbed surfaces to match with the existing specification complete all as specified and directed.

350

-

-

... More
All as per item no.04 but One 3 pin 5/6 Amps switch socket outlet on independent board complete all as specified and directed.

30

-

-

... More
All as per item no.04 but One 3 pin 5/6 Amps switch socket outlet on same board complete all as specified and directed.

30

-

-

... More
All as per item no.04 but for One 3 pin 15 / 16 Amps switch socket outlet point on independent board with 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable (green colour) as earth lead complete all as specified and directed.

30

-

-

... More
S&F in repair switch piano flush type single pole one way 5/6 Amps complete all as specified and directed.

700

-

-

... More
S&F in repair switch socket combination flush type 5/6 Amps Multipurpose 2 in 1, 3 pin/ 5 pin with porcelain base complete all as specified and directed.

170

-

-

... More
S&F in repair switch socket combination 2 in 1 flush type universal 3 pin 5 & 15 Amps complete all as specified and directed.

80

-

-

... More
S&F in repair lamp holder insulated body with back plate suitable for battern fittings complete all as specified and directed.

90

-

-

... More
S&F in repair Ceiling rose surface bakelite 65 x 50 mm 2/3 terminals complete all as specified and directed.

720

-

-

... More
S&F in repair Fan Regulator (Rotary step type, Switch/Socket type Dimmer) 230/240V, AC complete all as specified and directed.

60

-

-

... More
S&F in repair Modular switch, single pole, one way, 6 Amps one module complete all as specified and as directed.

50

-

-

... More
S&F in repair Modular 6A 3 pin universal socket outlet, 2 module complete all as specified and as directed.

50

-

-

... More
S&F in repair Modular switch, single pole, one way, 16 Amps one module complete all as specified and as directed.

40

-

-

... More
S&F in repair Modular socket outlet 2-in-1, 6/16 Amps, 2 module complete all as specified and as directed.

40

-

-

... More
S&F in repair modular stepped type electronic fan regulator 220 volts, 100Watt complete all as specified and as directed.

20

-

-

... More
S&F in repair 9 W LED bulb of base B22d with color temp 6500K all as specified and directed.

90

-

-

... More
S&F in repair Factory made DB in sheet steel enclosure vertical single door with 200 Amps rated bus bar, TPN, 4 ways, 240 Volts suitable for housing MCBs as incomer and SP MCBs as outgoing complete all as specified and as directed.

8

-

-

... More
S&F in Sheet metal enclosure MCB DB including 200 Amps bus-bar single pole and neutral 240V, 8 Ways, double door including taking down of existing sheet metal enclosure complete all as specified and directed.

12

-

-

... More
S&F in Sheet metal enclosure MCB DB including 200 Amps bus-bar single pole and neutral 240V, 4 Ways, double door including taking down of existing sheet metal enclosure complete all as specified and directed.

6

-

-

... More
S&F in repair MCB, Four pole, 240 volts, 63 Amps 10 KA C curve complete all as specified and as directed.

8

-

-

... More
Supply and fixing 240V, 10 KA 'C' curve MCB SPN and current carrying capacity 32 AMP complete with connection testing and commissioning complete all as specified and as directed.

18

-

-

... More
Supply and fixing 240V, 10 KA 'C' curve MCB SP, current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed.

180

-

-

... More
Submain wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 6 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead in and including PVC conduit medium grade with all fittings suitable for concealed type and making good the disturbed wall surfaces to match with existing specification all as required at site complete with all as specified and directed.

250

-

-

... More
S&F 25W energy saving and environmental friendly long life LED building security street light made up of pressure die cast aluminium housing with high power LED, lens & toughened glass, potted driver, IP 66 protection including connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed.

50

-

-

... More
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead complete all as specified and directed.

10

-

-

... More
Supply and fixing 22/20W decorative wall mounted LED Batten with aluminium housing and integrated electronic driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.

500

-

-

... More
Supply and fixing 10W decorative wall mounted LED Batten with aluminium housing and integrated electronic driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.

50

-

-

... More
S&F in repair 36W recess mounting ultraslim LED flat panel 2'x2' made of extruded aluminium frame with high efficient LEDs & glare free opal diffuser, IP20 suitable for armstrong/ grid ceiling and connecting with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and as directed.

30

-

-

... More
Supply and fixing in repair LED based Bollard lights with aluminium pipe housing with glare free PMMA diffuser, IP 65 with height of 645MM complete all as specified and directed.

30

-

-

... More
S&F in repair LED light fittings, 1x10 watts bulk head luminaires etc with all accessories and including connecting up with twin core twisted flexible PVC copper conduct cabe of 23/0.0076 from ceiling rose complete all as specified and as directed.

60

-

-

... More
Disconnecting and removing ceiling fan /wall mounting fan/exhaust fan from any height bringing down, dismantling, cleaning internally and externally thoroughly examine & replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, re-assembling, including replacement of wornout/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan including testing complete all as specified and as directed. NOTE :- (1) Necessary replacement of unserviceable parts/ winding shall be measured and paid seperately. (2) Labour element for replacing of unserviceable parts deemed to be included in rate quoted.

175

-

-

... More
Supply only oil filled Capacitor, 2.5 mfd suitable for ceiling fan.

160

-

-

... More
Supply only oil filled Capacitor 4 mfd suitable for exhaust fan.

15

-

-

... More
Supply only Ball bearing suitable for ceiling fans /wall mounting fan/ exhaust fan including necessary greasing.

45

-

-

... More
Supply only bushing suitable for ceiling fans /wall mounting fan/ exhaust fan.

25

-

-

... More
Supply only Rubber bush with clamp, nuts and bolts for ceiling fan.

25

-

-

... More
Supply only shaft made out of carbon steel including necessary lathe work for ceiling fan.

25

-

-

... More
Taking out defective winding from ceiling fan of any sweep and rewinding with equivalent new super enamelled copper wire as per existing gauge and weight as per manufacturer's design and instructions including varnishing complete all as specified and directed

160

-

-

... More
All as per Item No. 41 above but for exhaust fan of 225 to 305mm sweep.

10

-

-

... More
All as per Item No. 41 above but for exhaust fan of 330 to 400mm sweep.

5

-

-

... More
Supply only Fan blades suitable for existing ceiling fans.

15

-

-

... More
Taking down water heater (Electric Geyser) of any type /make of 25/50 Ltrs capaciry after disconneting electric connection wire / water pipe , inspecting the inner tank and components for necessary repairs including cleaning and removal of scales etc servcing and re-assembling in all respects after replacing unsv parts/components and testing for proper working after repairs and fixing in the original place/ position duly connecting up water supply and electric supply complete including civil work for grouting complete all as specified and as directed. Note : Necessary repairs /replacement parts shall be measured and paid seperately.

8

-

-

... More
Supply only chromium plated connecting pipe with two brass adopters and brass flexible tubing for Hot water pipe connection for geyser

8

-

-

... More
Supply only PVC cold water connection pipe with 2 Nos brass adopters/ check nuts for geyser

8

-

-

... More
Supply only non return valve 15/20mm dia for cold water connection of geyser

8

-

-

... More
Supply only Pressure release valve suitable for 25/50 Ltrs capacity Geyser complete all as specified.

8

-

-

... More
Supply only thermostat including rubber gasket suitable for 25/50 litres capacity geyser

8

-

-

... More
Supply only Indicator bulb neon AC 230 Volts (Round/Square)

8

-

-

... More
Supply only Heating Element 1500 Watts including rubber/PVC gasket of push type/threaded /round /triangle base type (as per sample)

8

-

-

... More
Supply only Heating Element 2000 Watts including rubber/PVC gasket of push type/threaded /round /triangle base type (as per sample)

8

-

-

... More
Schedule 'A' Part II (External Electrification)

-

-

-

... More
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core inlcuding taking up old unserviceable cable complete all as specified and directed.

250

-

-

... More
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 2 core inlcuding taking up old unserviceable cable complete all as specified and directed.

250

-

-

... More
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core inlcuding taking up old unserviceable cable complete all as specified and directed.

175

-

-

... More
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core inlcuding taking up old unserviceable cable complete all as specified and directed.

175

-

-

... More
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core inlcuding taking up old unserviceable cable complete all as specified and directed.

85

-

-

... More
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core inlcuding taking up old unserviceable cable complete all as specified and directed.

85

-

-

... More
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core inlcuding taking up old unserviceable cable complete all as specified and directed.

40

-

-

... More
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core inlcuding taking up old unserviceable cable complete all as specified and directed.

40

-

-

... More
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for foundation, laying of poles/ cables and getting out in hard/dense soil complete all as specified and directed.

202.5

-

-

... More
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed.

94

-

-

... More
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed.

108.5

-

-

... More
Supply and spread dry river sand including watering and consolidation as in cushioning of cable laid in trenches complete all as specified and directed. Note:- Punned thickness shall be measured for payment purpose.

81

-

-

... More
M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as specified and directed.

8700

-

-

... More
M & L for cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable/pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.

12

-

-

... More
M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32mm x 6mm dia by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point incl necessary earth work and excavation PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with SSR Part-II RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with water pipe GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia, light grade all as specified and directed in SSR Part II. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately.

8

-

-

... More
Disconnecting existing panel and its connections and supply, install, testing and commissioning of new Out door LT feeder panel of 500 Amps, factory fabricated, CPRI Tested, cubicle type of suitable size with 3.15 mm thick CRCA sheet outdoor type vermin proof with Aluminium bus bar of size 50 mm x 10 mm, Al strip 3 phase and neutral connections with neutral colour coded with heat and shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangement and painting with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wiring, accessories fitted on suitable insulator all housed in suitable bus bar chamber and along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands including PCC foundation using PCC 1:4:8 type D2 etc and testing and commissioning complete all as specified and directed and consisting the following :- (a) MCCB 4 Pole, 415 volts adjustable type, 250 Amps wth breaking capacity 36KA -01 No. (incoming) (b) MCCB 4 Pole, 415 volts adjustable type,160 Amps with breaking capacity 36KA -2 Nos. (Outgoing) (c) MCCB 4 Pole, 415 volts adjustable type,100 Amps with breaking capacity 36KA -1 No. (Outgoing) (d) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts with selector switch and Ammeter 0-500 Amps with selector switch and LT-CT operated complete - 01 Set (e) Phase Indicating lamp LED type for Red, Yellow and Blue - 01 Set

1

-

-

... More
Supply, installation, test and commissioning CPRI Tested, factory fabricated, outdoor type, LT FEEDER PILLAR BOX made out of 3.15mm thick CRCA sheet of size 1M x 0.75M x 0.35M with projected globe roof for rainwater protection dust and vermin proof, double door with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 Wire System, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc cromium plated nuts, bolts and washers etc. and embeded with 50x50x6mm MS angle iron frame, 600mm above the normal ground level complete with internal connection with suitable size of cable, cable lugs and cable glands, PCC foundation in cement concrete 1:4:8 (20mm graded stone aggregate) and testing after installation complete all as specified and comprising of the following :- (a) Aluminium busbar 200 amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 100 Amps, 415 volt, 16 KA breaking capacity 4 pole electromagnetic release duly connected to busbar as incoming - 01 No.

1

-

-

... More
S & F cable end termination jointing kit for 1.1 KV (earthed) grade cable for outdoor end termination heat shrinkable type joint with jointing material and accessories suitable for 3.5 core of the following sizes, including taking out old unserviceable end termination joint complete all as specified and directed.

-

-

-

... More
35 Sqmm to 70 Sqmm

2

-

-

... More
95 Sqmm to 150 Sqmm

2

-

-

... More
185 Sqmm to 300 Sqmm

1

-

-

... More
S & F cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor termination heat shrinkable type straight through joint with jointing material and accessories suitable for 3.5 core cable for following sizes, including taking out old unserviceable straight through joint complete all as specified and directed.

-

-

-

... More
35 sqmm to 70 sqmm

2

-

-

... More
95 sqmm to150 sqmm

2

-

-

... More
185 Sqmm to 300 Sqmm

1

-

-

... More
Supply, Fixing and stringing ACSR Conductor steel reinforced of type as directed including stretching, binding using ACSR conductor on insulator complete, on overhead line including taking down existing conductor complete all as specified and directed.

1

-

-

... More
Stringing only ACSR Conductor of type as directed including binding using ACSR conductor on insulator on overhead line, complete all as specified and directed .

500

-

-

... More
S&F Stay assembly complete with accessories as shown in electric plate No.1 stay rod 16mm dia including loop type insulator, stay clamps, also including excavation and earth work, PCC foundation etc., and taking out old unserviceable stay assembly complete all as specified and directed.

2

-

-

... More
M&L Mild steel Cross arm bracing support clamps and back plates fabricated from structural steel sections including nuts, bolts and washers, welding, bending, cold or hot drilling holes for bolts in any shape or sizes as indicated or directed inclding one coat of red oxide zinc chrome primer and two coats of aluminium paint, and removing the existing cross arms etc complete all as specified and directed.

1

-

-

... More
M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two glavanised iron washers and one galvanised iron nut,100mm height, 65mm dia for 1100 Volts grade, including taking down existing insulators complete all as specified and directed.

20

-

-

... More
M&L Shakle type, porcelain, vitreous, white brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts 100mm in height, 115mm dia, working pressure 1100 volts, section of strap 31x 5, 14mm dia bolts including taking down the existing porcelain insulator complete all as specified and directed.

12

-

-

... More
Cutting & trimming of tree branches any girth and size touching to overhead lines and cleaning the distance 1.5 mtr both sides of overhead line with in a gap of span 35 mtrs each and removing the spoil outside MD land, cleaning the site complete all as specified and directed.

50

-

-

... More
S&F PVC separators suitable for LT over head line of 4 conductors complete all as specified and directed.

20

-

-

... More
M&L MCCB 415 Volts, 4 pole, fixed type, 100 Amps, with breaking capacity 16 KA complete with all connected accessories including taking out old unserviceable MCCB complete all as specified and directed.

3

-

-

... More
M&L MCCB 415 Volts, 4 pole, adjustable type, 160 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old unserviceable MCCB complete all as specified and directed.

3

-

-

... More
M&L MCCB 415 Volts, 4 pole, adjustable type, 200 Amps, with breaking capacity 36 KA complete with all connected accessories including taking old unserviceable MCCB complete all as specified and directed.

3

-

-

... More
M&L MCCB 415 Volts, 4 pole, adjustable type, 250 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old unservuceable MCCB complete all as specified and directed.

3

-

-

... More
M&L for cleaning thoroughly LT distribution poles of any height and any description (Maximum 9 Mtr long ) with necessary cleaning agent including scrapping of old corroded paint dirt / rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping complete all as specified and directed .

20

-

-

... More
Removing Existing unserviceable Analog voltmeter with electrical connections and supply and install, test the new voltmeter 0-500V complete all as specified and directed.

4

-

-

... More
Removing Existing unserviceable Analog ammeter with electrical connections and supply, install and testing new ammeter 0-250A/100A with necessary wires complete all as specified and directed.

4

-

-

... More
S&F in repair test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hexagonal headed screws complete all as specified and directed.

6

-

-

... More
S&F, in repair, galvanised iron strip of size 32x6mm complete all as specified and directed.

20

-

-

... More
Surface dressing up to 15 cm in depth including cleaning of vegitation, removing grass, small plants and other unwanted material and levelling around tranformer yard and surrounding area and removal of excavated materials at a distance not exc 50 m where directed complete all as specified.

200

-

-

... More
M&L for repair of existing LT panel outddor/indoor type by properly fixing loose/dislocated MS doors complete with provision of hinges and welding at locations as necessary, provision of tower bolt as per as existing size including painting of internal and external surfaces with one coat of synthetic enamel paint of approved colour after preparation of old painted surfaces complete as required for smooth operation of panel and as directed by the Engr-in-charge (Size of Panel board n.exc 2.25x1.2x0.6 m) NOTE: Cost of MS sheet, Tower bolt, sliiding bolt wherever required shall be included in the unit rate quoted by the Contractor.

4

-

-

... More
Disconnecting defective oudoor/indoor power distribution transformer of various sizes/capacties from HT/LT and earth conection and taking out from two pole structure/plinth, removing complete transformer oil, storing the same in suitable containers (to be provided by contractor) opening top cover and lifting up the core assembly carefully to check the condition of transformer winding core, refixing the same after repair refilling the transformer oil and dehumidification and filteration (dehumidification and filteration to be measured and paid separately under respective items ) including checking of leakage of transformer body and welding works required for making transformer body leak proof including transportation of transformer from site to work shop and re-installing the same at site and painting of transformer as directed for transformer of capacity upto 200 KVA complete all as specified and directed. Note : The materials required for rectification of defects such as rewinding / transformer oil / bushes etc shall be measured and paid separately

1

-

-

... More
All as per item No.99 herein before but for transformer of capacity 500 KVA complete all as specified and directed.

1

-

-

... More
Removing the burnt out HT winding and rewinding with braided copper conductor to match with the existing gauge and number of turns complete all as specified and directed.

75

-

-

... More
All as per item No.101 here in before but for LT windings complete all as specified and directed.

40

-

-

... More
Replacement of silica gel breather with and including silica gel as per the existing size / model at site complete all as specified and directed.

1

-

-

... More
Replacement of temperature gauge as per the existing size / model at site complete all as specified and directed.

1

-

-

... More
Removing the burnt out LV bushes and replace the same with new Brass LV bushes, nuts , check nuts etc complete as that of existing size / model, for transformers of capacity 200 KVA complete all as specified and directed.

1

-

-

... More
All as per item No.105 here in before but of capacity 500 KVA all as specified and directed.

1

-

-

... More
Removing the burnt out HV bushes and replace with Brass HV bushes, nuts , check nuts etc complete as per the existing size / model, for transformers of capacity 200 KVA to 500 KVA complete all as specified and directed.

3

-

-

... More
Removing the burnt out LV side insulators and replace the same with new Insulator complete as that of existing size / model, for transformers of capacity 200 KVA to 500 KVA all as specified and as directed.

4

-

-

... More
Dehumidification and filteration of transformer oil at different locations by dehumidification plant including testing of oil samples both before and after filteration all as specified and as directed . The dielectric strength of the transformer oil shall not be less than 40 KVA with 2mm gap after filtration. Note : (a) The qoated rate shall be deemed to include necessary T&P for collection of transformer oil sample, Testing Kit, Filteration plant and also include for making necessary connection to filtration plant from transformer and switch gear. (b) Test result obtained shall be recorded and produced to Engineer-in-charge and kept in record.

570

-

-

... More
Supply and filling transformer oil low viscosity of approved make/quality with rupturing capacity 60 KV for 60 Seconds suitable for 11 KV tansformer as per IS 335 of 1983 for topping up/replacement complete all as specified and directed. Note : The Transformer Oil shall be ISI Marked and brought at site in sealed container only.

190

-

-

... More
M&L for repairing & servicing with primary and secondary injection and caliberation of 11 KV HT VCB by taking out the enclosure including all components and cleaning the bus bar complete & refixing the same after duly repaired and replacement of unserviceable components/parts complete as required and directed. (Note:- New Spare/Parts shall be measured and paid separately under relevant items as “Supply only”)

1

-

-

... More
Supply only Vaccum Interrupter/Vaccum bottle 440 Volts as per existing make complete all as specified and directed.

1

-

-

... More
Supply only Spring charging motor, 250 Watt, 240 Volts, AC as per existing make complete all as specified and directed.

1

-

-

... More
Supply only Breaker Control switch with spring return and sequence device, 32 Amps, 440 Volts as per existing make complete all as specified and directed.

1

-

-

... More
Supply only Closing spring, 440 Volts of existing make complete all as specified and directed.

1

-

-

... More
Supply only Closing release, 440 volts, of existing make complete all as specified and directed.

1

-

-

... More
Supply only Tripping lever, 440 Volts of existing make complete all as specified and directed.

1

-

-

... More
S&F in repair 60W energy saving and environmental friendly long life LED security street light made up of pressure die cast aluminium housing with high power LED, lens & toughened glass, potted driver, IP 66 protection including connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed.

32

-

-

... More
S&F in repair 90W energy saving and environmental friendly long life LED security street light made up of pressure die cast aluminium housing with high power LED, lens & toughened glass, potted driver, IP 66 protection including connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed.

30

-

-

... More
S&F Hot press moulded SMC Junction box of size 270 mm x 200 mm x 135 mm with right openable hinged door with two number aluminium bus bars mounted on porcelain insulator including clamps of MS flat iron 25 x 3 mm with bolts and nuts and including one MCB SP upto 6A, 10 KA for ON/OFF street light, fixed on pole including taking down old juction box, complete all as specified and directed.

20

-

-

... More
S & F of nature switch pole mounted encloser consisting of NATURE SWITCH-02, power contactor for load switching, MCB, and terminal blocks. The enclosure complete with mounting brackets, cable glands, openable door with lock and key. The enclosure is made of UV stabilized, FR grade special moulding compound to provide a rust proof, electric shock proof, termite proof, outdoor mountable electrically insulated body capable of enduring solar radiation in the outdoor. Selectable options are available for duration based switching OFF suitable for single phase operation of 08 KW load, 230 Volts, 50 Hz, AC , with all connected accessories, including taking down existing timer switch of any description, complete all as specified and directed.

2

-

-

... More
S&F Driver circuit board 45/48W with necessary wiring including taking down exisitng driver circuit board from street light pole of any make and refixing the same after repair complete all as specified and directed.

22

-

-

... More
S&F Driver circuit board 60W with necessary wiring including taking down exisitng driver circuit board from street light pole of any make and refixing the same after repair complete all as specified and directed.

22

-

-

... More
S&F Surge protector device for street light fitting of any make/type with necessary wiring including taking down exisitng surge protector device from street light pole, complete all as specified and directed.

20

-

-

... More
M&L for cleaning thoroughly the street light poles of any height and any description (Maximum 9 Mtr long ) with necessary cleaning agent including complete removal of existing paint by scrapping etc carefully and applying two coat of synthetic aluminium paint over a coat red oxide primer complete all as specified and directed .

50

-

-

... More
S&F PVC insulated and FR PVC round sheathed, copper conductor, flexible industrial cable, 1100Volts, 1.5 Sqmm 2 core for connection from junction box to streetl ight fitting including pvc conduit of suitable size complete all as specified and directed.

150

-

-

... More
Schedule 'A' Part III (External Water Supply)

-

-

-

... More
Supply & fixing galvanized steel water tubing medium grade of 15mm bore with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc including taking up or down steel tubing with all fittings 15mm dia complete all as specified and directed.

22

-

-

... More
All as per Item No. 128 but 20mm bore

36

-

-

... More
All as per Item No. 128 but 25mm bore

36

-

-

... More
All as per Item No. 128 but 40mm bore

30

-

-

... More
All as per Item No. 128 but 50mm bore

30

-

-

... More
All as per Item No. 128 but 80mm bore

12

-

-

... More
Supply & fixing in repairs gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of 15mm bore including taking down complete all as directed.

5

-

-

... More
All as per Item No. 134 but 20mm bore

10

-

-

... More
All as per Item No. 134 but 25mm bore

12

-

-

... More
All as per Item No. 134 but 40mm bore

2

-

-

... More
All as per Item No. 134 but 50mm bore

2

-

-

... More
Taking out the unserviceable cast iron sluice valve for size 80 mm bore, supply and fixing of new CI sluice valves PN 1.6 confirming to ISI with flanged ends, both end drilling with SS spindle, round wheel including jointing materials, nuts, bolts and gasket complete all as specified and directed.

2

-

-

... More
Construction of valve chamber with PCC 1:4:8 type D2 for foundation, brick wall in cement mortar (1:4), PCC 1:2:4 type B1 for coping, rendering in CM (1:4) 15mm thick for internal surfaces, 3 mm thick MS sheet cover with angle iron frame of 40 x 40 x 6mm fixed in coping concrete, hinges welded and applying two coats of synthetic enamel paint over a coat of redoxide primer, locking arrangement including necessary excavation earth work in any type of soil for 600 x 600 x 600 mm depth complete all as secified and directed.

2

-

-

... More
All as per Item No. 140 but size of 900 x 900 x 900 mm

2

-

-

... More
Schedule 'A' Part IV (Regrigeration and AC)

-

-

-

... More
Taking down carefully old burnt/unserviceable compressor unit of 1.0 ton capacity window type/Split type AC and replacing the same with New compressor including necessary accessories and mounting materials, welding, brazing, leak testing, vaccumissing and charging the refrigerant gas to the required pressure and weight, reinstalling the AC unit on the same place including testing and commissioning complete to any make of AC all as directed. Note:- Rate quoted shall be inclusive of R-22 refrigerant gas charging, testing and commissioning.

2

-

-

... More
All as per item No :143 above but for Window/Split type AC 1.50 Ton Capacity

2

-

-

... More
All as per item No : 143 above but for Window/Split type AC 2.00 Ton Capacity

2

-

-

... More
S&F Relay assembly and connecting with necessary wiring complete suitable for Window/ Split type of AC 1.0/1.5/2.0 Ton Capacity including taking out the old unserviceable relay assembly complete all as specified and directed.

2

-

-

... More
S&F Over load protector suitable for Window/ Split type AC of 1.0/1.5/2.0 Ton Capacity including removal of old unserviceable over load protector complete all as specified and directed.

2

-

-

... More
S&F Thermostate set for window/split type AC of any make/ model of Capacity 1.0/1.5/2.0 Ton including removing the old unserviceable thermostat complete all as specified and directed.

2

-

-

... More
S&F Blower fan motor, with fixing arrangement, operating on 215 / 240 Volts, single phase AC supply, multi speed suitable for Window AC 1/1.5/2.0 Ton capacity including taking out the old unserviceable blower fan motor complete all as specified and directed.

2

-

-

... More
S&F Capacitor of 36/45 MFD for Window/ Split type AC's all as directed and taking out the old unserviceable capacitor complete all as specified and directed.

2

-

-

... More
S&F Capacitor of 50/60 MFD for Window/Split type AC's all as directed and taking out the old unserviceable capacitor complete all as specified and directed.

2

-

-

... More
Servicing to the split type AC units of 1/1.5/2.0 ton capacity, cleaning of the evaporator coils externally with Caustic Soda / Chemical to remove the dust particles deposited on the cooling coil, cleaning of the condensing units to reduce the discharge pressure with the Caustic Soda / Chemical and testing complete all as specified and directed.

6

-

-

... More
Servicing to the window type Air Conditioners of capacity 1/1.5/2.0 ton capacity, cleaning of the evaporator coil externally with Cautic Soda / chemical to remove the dust particles, cleaning of the filters and testing complete all as specified and directed.

2

-

-

... More
Taking down unserviceable Indoor unit of Split type AC of 1.5 TR capacity any make, model and S & F new indoor uint of same capacity suitable to existing Outdoor Unit including the necessary connections and testing complete all as specified and directed.

2

-

-

... More
Taking out burnt / unserviceable compresser from existing water cooler and S & F new sealed compressor unit including necessary welding/brazing/pressure testing with refregerant after charging leak proof condition and testing, for water cooler of capacity 80/100 ltrs complete all as specified and directed. Note:- Rate quoted shall be inclusive of R-22 or R-134a Refrigerant gas charging, testing and commissioning.

2

-

-

... More
S&F Relay assembly and connecting with necessary wiring for water cooler of 40/60/120 ltrs capacity and taking down unserviceable relay assembly complete all as specified and directed.

2

-

-

... More
S&F Over load protector suitable for Water cooler of capacity 40/60/150 Ltr including removal of old Un-Serviceable over load protector complete all as specified and directed.

2

-

-

... More
S&F Starting capacitor of 60/80 MFD for water cooler all as directed and taking out the old unserviceable starting capacitor complete all as specified and directed.

2

-

-

... More
S&F Thermostate set complete for Water cooler of any make/ model/ capacity including removing the old unserviceable thermostat complete all as specified and directed.

2

-

-

... More
S&F Capacitor of 6/10 MFD for water cooler/ Refrigerator all as directed and taking out the old unserviceable capacitor complete all as specified and directed.

2

-

-

... More
S&F Water cooler condenser suitable for 40/60 ltrs cooling capacity including necessary welding/ brazing/ pressure tesing with Nitrogen Complete and taking out the old unserviceable condenser complete all as specified and directed.

2

-

-

... More
S&F Water cooler condenser suitable for 80/120 ltrs cooling capacity including necessary welding/ brazing/ pressure tesing with Nitrogen Complete and taking out the old unserviceable condenser complete all as specified and directed.

2

-

-

... More
Taking out burnt / unserviceable compressor from existing refrigerator and S & F new sealed compressor unit including necessary welding/brazing/pressure tesing with Nitrogen after charging leak proof condition and testing, for refrigerator of 165 ltrs capacity complete all as specified and directed. Note:- Rate quoted shall be inclusive of R-134a refrigerant gas charging, testing and commissioning.

2

-

-

... More
S & F relay assembly and connecting with necessary wiring complete for Refrigerator of 165/286 ltrs capacity and taking down unserviceable relay assembly complete all as specified and directed.

2

-

-

... More
S & F relay assembly and connecting with necessary wiring complete for Refrigerator of 310 ltrs capacity and taking down unseviceable relay assembly complete all as specified and directed.

2

-

-

... More
S & Fix Thermostate set complete for Rifrigerator of any make/model/capacity including removing the old unserviceable thermostat set complete all as specified and directed.

2

-

-

... More
S & Fix Over load protector complete suitable for Refrigerator of any make/ model of 165/280/310 Capacity including removal of old Un Serviceable over load protector complete all as specified and directed.

2

-

-

... More
S & Fix Refrigerator timer for frost free refrigerator of any capacity and taking out the old unserviceable timer complete all as specified and directed.

2

-

-

... More
S & Fix Refrigerator condenser coil of 165 ltrs capacity including necessary welding/ brazing/ pressure tesing with Nitrogen and taking out the old unserviceable condenser complete all as specified and directed.

2

-

-

... More
S & Fix Refrigerator condenser coil of 310 ltrs capacity including necessary welding/ brazing/ pressure tesing with Nitrogen and taking out the old unserviceable condenser complete all as specified and directed.

2

-

-

... More
Taking out burnt / unserviceable compressor from existing Deep Freezer and S & F new sealed compressor unit including necessary welding/ brazing/ pressure testing with refrigerant after charging leak proof condition and testing, for Deep freezers of any capacity. Note:- Rate quoted shall be inclusive of R-134a refrigerant gas charging, testing and commissioning.

1

-

-

... More
S & Fix Over load protector complete suitable for Deep Freezer of any make/model of capacity 280/310 Ltrs including removal of old Un Serviceable over load protector complete all as specified and directed.

1

-

-

... More
S & Fix Thermostate set complete for Deep Freezer of any make/model of capacity 280/310 Ltrs including removing the old unserviceable thrmostat set complete all as specified and directed.

1

-

-

... More
S & Fix Copper capillary tube including strainer with necessary brazing, Leak Testing suitable for Deep Freezer and taking out the old unserviceable one complete all as specified and directed.

1

-

-

... More
S & Fix capacitor of 4/5 MFD for Desert Cooler all as directed and taking out the old unserviceable capacitor complete all as specified and directed.

2

-

-

... More
S & Fix Khas-khas screen(set of three) for desert coolers of any make and size and removing the old screen Complete.

2

-

-

... More
S & Fix Fan blade of desert cooler Metallic/PVC as per existing model for desert coolers of any make for capacity 3000/4000 cfm and taking out the old unserviceable fan blades complete all as specified and directed.

2

-

-

... More
S & Fix PVC water tube and distribution with 3 way PVC connection & bends assembly complete, for desert coolers of any make for capacity 3000/4000 cfm and taking out the old unserviceable one complete all as specified and directed.

2

-

-

... More
S & Fix Switch assembly as approved by the Engr-in-charge, for desert coolers of any make for capacity 3000/4000 cfm and taking out the old unserviceable one complete all as specified and directed.

2

-

-

... More
S & Fix in replacement of old unserviceable fan motor with new fan motors of desert coolers of 4000/5000 cfm capacity with nuts, bolts, brackets, connecting arrangeents reconnecting inclduing removing of the old unserviceable and testing complete all as specified and directed.

2

-

-

... More
S & Fix water circulating pump 1/7 HP, SP 1340 RPM having a head of 1.5 mtr suitable for desert cooler including nuts and bolts, washers brackets for fixing connecting with necessary wiring commissioning and testing and including taking down the old water circulating pump complete all as specified and directed.

2

-

-

... More
S & Fix Front grill / side grill of desert cooler suitable to existing one, any make/model for capacity 3000/4000 cfm and taking out the old unserviceable one complete all as specified and directed.

2

-

-

... More
M&L for repairing of stabilizer of 1 KVA capacity including rewinding of Transformer including replacement of PCBs, minor spare parts complete all as specified and directed.

1

-

-

... More
All as per Item No.183 above but 4 KVA capacity for window /Split A/C 2.0 Ton complete all as specified and directed.

1

-

-

... More
All as per Item No.183 above but 5 KVA capacity for window /Split A/C 2.0 Ton complete all as specified and directed.

1

-

-

... More
Supply & charge refrigerant gas R-22 upto required level complete all as specified and directed.

15

-

-

... More
Supply & charge refrigerant gas R-134a upto required level complete all as specified and directed.

15

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.