For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
₹ 67,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_687721_1Bid Award Id
ViewTender No
8641/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://https://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for rendering 10mm thick cement plaster 1:4, incl finishing even and smooth without using extra cement on internal faces complete all as specified and as directed.
215
-
-
... More
M&L for cement plaster 1:3, 5mm thick incl finishing even and smooth without using extra cement on ceiling complete all as specified and as directed.
50
-
-
... More
M&L for dismantling stone slabs and tiles of any description or thickness laid, bedded, pointed in any mortar in floors etc complete all as specified and as directed.
8.75
-
-
... More
M&L for Vitrified Ceramic tiles light shed 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
87.5
-
-
... More
M&L for 15mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying floor finishes all as specified and directed
87.5
-
-
... More
M&L glazed ceramic coloured tiles 450x300x6 to 7mm thick on vertical surfaces such as dados, wall etc set and jointed in neat cement slurry and pointed in white or coloured cement to match on vertical surfaces complete all as specified and as directed.
70
-
-
... More
M&L Rendering 10mm thick in CM (1:4) finished rought to receive wall tilescomplete all as specified and as directed.
70
-
-
... More
M&L for 20mm thick Granite (of any type) tiles machine cut, bedded and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and rounding edges, over 15 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying floor finishes complete all as directed
14
-
-
... More
M&L for applying two coats of OBD over two coat of wall care putty over a coat of alkali resistant primer including preparing the new plastered wall surfaces complete all as directed.
35
-
-
... More
M&L for complete removal of existing surfaces on walls and applying two coats of oil bound distemper over two coat of wall care putty over a coat of alkali resisitant primer complete all as specified and directed.
80
-
-
... More
M&L for complete removal of old surface of ceilings and applying two coat of white wash complete all as specified and directed.
87.2
-
-
... More
Form work to flat surfaces of RCC fins, fascia ,chjjas and similar items including edges, for fair finished surfaces complete all as specified and as directed by Engineer-in-Charge.
17
-
-
... More
M&L for RCC 1:2:4 type B1 (Using 20mm graded stone aggregate) chajjas and similar suspended works complete all as specified and shown on drgs.
3
-
-
... More
M&L for Mild steel TMT bars 6mm to 8mm , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips all as specified.
100
-
-
... More
S&F Prelaminated particle board of thickness 18/19 mm, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to frame.
28
-
-
... More
S&F Prelaminated particle board of thickness 25mm,exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to frame.
25
-
-
... More
M&L 2nd class hard wood plain fillets sectional area exc 13 sqcm but n. exc 25 sqcm square (as in chowkats of CBs), rectangular in section, wrought and smooth finish, secured with nails or brads complete incl polishing all as specified.
60
-
-
... More
M&L 2nd class hard wood fillets sectional area exc 6 sqcm but n. exc 13 sqcm square, rectangular in section, Wrought and smooth finish complete all as specified.
50
-
-
... More
M&L 2nd class hard wood fillets (in beading of CBs shutter) sectional area n. exc 3 sqcm square, rectangular or triangular in section, Wrought and smooth finish but bullnosed, splayed chamfered or rounded on one edge or face complete all as specified.
88.5
-
-
... More
S&F continuous (Piano) Hinges 30 mm width of flaps, mild steel bright finish or elecrogalvanised complete all as specified.
27.5
-
-
... More
S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of brass, polished all as specified and as directed.
68
-
-
... More
S&F 150mm size aluminium anodised handles, fabricated type complete all as specified.
34
-
-
... More
S&F Aluminium Mortice lock, vertical type, size 65 mm, long 2 levers with handles complete all as specified and directed.
34
-
-
... More
S&F for magnetic door stopper for cupboard complete all as specified and directed.
34
-
-
... More
S&F 15mm dia unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe all as specified and directed.
15
-
-
... More
S&F Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, waste coupling CP brass, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mm X 460mm with bowl size 410mm X 330mm X 160mm complete all as specified.
1
-
-
... More
M&L Preparation of old surfaces of wood and wood based surfaces and applying one coat of synthetic enamel paint of any description not otherwise described over 10 cm width or girth complete all as specified and directed.
30
-
-
... More
Taking down chowkats or frames with shutters (without taking off shutter from the frames) exceeding 1.5 Sqm each but n.exc. 4 sqm each complete all as specified.
2
-
-
... More
Excavating in trenches n exc 1.5m wide and not exc 1.5m depth; for foundation, etc not exc 10 sqm on plan and getting out in hard/dense soil complete all as specified and as directed.
30
-
-
... More
M&L for PCC 1:4:8 type D2 using 40mm graded aggregate in foundation /mass concrete for footing and steps complete all as specified and as directed.
5
-
-
... More
M&L Brick work with fly ash bricks, straight or curved on plane to any radius but in half thick built in CM 1:6 all as specified and directed
6
-
-
... More
M&L Brickwork with fly ash bricks, straight or curved on plan exc 6 Mtr mean raius built in CM 1:6 all as specified and directed
30
-
-
... More
M&L for formwork to fair finished surfaces of timber form work to sides and soffits of floor or roof beam , lintels including support , overhangs etc also splays between floors and beams etc complete all as specified and as directed.
110
-
-
... More
M&L for RCC Type B1 1:11/2:3 ( 20mm graded aggregate) in beams, cantilevers,bressummers, lintels over 1.5m span complete all as specified and as directed.
3
-
-
... More
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick complete all as specified and as directed.
60
-
-
... More
M&L for RCC Type B1 1:11/2:3 ( 20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
6
-
-
... More
M&L for TMT bar 10 mm dia and over cut to length bent to shape required, including cranking, bending, spirally for hooping for column hooking ends and binding with and including mild steel steel wire (annealed ) not less than 0.90 mm dia or seccuring with clips quility confirming to Deformed or twisted bars all as specified and directed
900
-
-
... More
Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders all as specified
300
-
-
... More
M&L for Rendering 15 mm thick cement plaster on fair faces of brick work/concrete in cement mortar 1:6, with water proofing compound finished even and smooth without using extra cement all as specified
120
-
-
... More
Supply only integral water proofing compound complete all as specified and as directed.
10
-
-
... More
M&L for preparation of new plaster surface of wall and applying two coat of white wash over a coat of primer complete all as specified and directed
40
-
-
... More
M&L for preparation of new plaster surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed
60
-
-
... More
M&L applying two coats of white wash, over a coat of primer on new ceiling surface including preparation of surface, complete all as specified and as directed by Engineer-in-Charge.
40
-
-
... More
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm in hard/dense soil complete all as specified and as directed.
16
-
-
... More
Removal of excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above starting point complete all as specified and as directed.
23
-
-
... More
M&L for Moorum/approved earth filling in floors or pavings laid in layers n.exc 15 cm thick spread levelled and rammed including watering complete all as specified and as directed.
8
-
-
... More
M&L Hardcore guage exc 63 mm n.exc. 100 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rolled / rammed to a true surface.brocken stone or boulders complete all as specified and as directed.
4
-
-
... More
M&L for cement concrete 75mm thick Type D-2 1:4:8 (using 40 mm graded stone aggregate) as in sub base complete all as specified and as directed.
32
-
-
... More
M&L cement concrete type B1, 1:2:4 (20mm graded Aggregate) 40 mm thick in floor complete all as specified and as directed.
32
-
-
... More
M&L screed bed or bedding layer of mortar 15mm thick in cm 1:6 for laying floor finishes all as specified and as directed.
12
-
-
... More
M&L for Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
24
-
-
... More
M&L for glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour ement to match complete all as specified and as directed.
60
-
-
... More
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in floor / plinth protection including finished even and smooth without using extra cement complete all as specified and as directed.
20
-
-
... More
M&L for rendering 10 mm thick in CM (1:3) using water proofing compound as per manufacturer instructions as in roof padding and chajjas complete all as specified. Note : Water proofing compound will be measured and paid separately.
30
-
-
... More
M&L for APP modified prefabricated five layer water proofing membrane minimum 3mm thick and weighing not less than3.6 kg/Sqm, reinforced with non woven polystester matt black finished (wt not less than150 gms/Sqm) over combatible primer at 0.40 Ltr/Sqm and torch applications of membrane with minimum 10cm side over lap and 15cm end laps and applying solar reflective bituminous aluminium paint @ 0.10 kg / sqm complete all as specified and as directed by Engineer-in-Charge.
30
-
-
... More
S&F Rolled mild steel in joist ,channel angle or tee section, flat iron for gates and truss work fixed independently quality conforming to Fe 410W(Gde-250) complete all as specified and as directed.
120
-
-
... More
M & L Preparation of steel surfaces or iron based material of any description over 10 cm in width or girth applying two coats of synthetic enamel paint over a coat of red oxide complete all as directed.
50
-
-
... More
Surface excavation n.exc 30cm deep and averaging 15 cm deep and getting out in soft and loose soil complete all as specified and as directed.
240
-
-
... More
M&L Hardcore guage exc 63 mm n.exc. 100 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rolled / rammed to a true surface.Brocken stone or Boulders complete all as specified and as directed.
24
-
-
... More
M&L for cement concrete Type D-2 1:4:8 (40 mm graded aggregate ),75mm thick as in sub base complete all as specified and as directed
240
-
-
... More
M&L for 50 mm sand filling under floors or in foundations including watering and consolidation spread, rolled and consolidated to gradient and camber required complete all as specified and as directed.
12
-
-
... More
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment complete all as specified and as directed.
240
-
-
... More
M&L screed bed or bedding layer of mortar 15mm thick in cm 1:6 for laying floor finishes complete all as specified and as directed.
12
-
-
... More
Excavation in Post holes ( or similar holes ) in hard dense soil, each not exc 0.5 cum, getting out, and removing excavated soil to a distance n.exc 50m complete all as specified and as directed.
26
-
-
... More
M&L Treating surfaces of ends of post etc area n.exc 0.1 sq.m each tretad with tar or coal tar black paint all as specified and directed
0.26
-
-
... More
M&L Providing cement concrete 1:2:4 in foundations, including raft footings, foundation beams and mass concrete.Type B-1,(using 20 mm graded aggregate), all as directed by Engr-in-charge.
2.38
-
-
... More
S&F Steel work in tubular trusses / rectangular or square, Hollow mild steel sections for structural use, including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to I.S.1161-1979 grade St-240, and Painted one shop coat of zinc chromate primer paint (including preparation of surface) at contractor's workshop before fabrication all as specified and directed
2900
-
-
... More
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe 410 -W (Gde-E- 250)
quality-A all as specified and directed.
40
-
-
... More
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheeting, 0.50 mm thick, of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws or or fixed with 'L' or 'J' type or cranked hooks bolts in liew of screw all as specified by Engr-in-charge.
200
-
-
... More
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/cladding to wall, ridge fixed with self tapping screws as specified
5
-
-
... More
E/M PORTION
Taking down existing serviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / Hylam sheet/ light fittings etc for refixing of removal serviceable material and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
58
-
-
... More
Material and labour for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked of suitable dia conduit wiring including Tee, Junction boxes and provision of modular terminal boxes and covered with modular cover plate with frame of suitable size including suitable screws with washer for mounting modular switch, modular sockets and modular regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to common earth dolly complete all as specified & as directed for One light point controlled by one, one way Modular switch 5 amps, SP
10
-
-
... More
All as per item No 75.00 above but for One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
8
-
-
... More
All as per item No 75.00 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
20
-
-
... More
All as per item No 75.00 above but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
4
-
-
... More
All as per item No 75.00 above but using 4.0 Sqmm single core copper conductor cable multistranded PVC insulated unsheathed 1100 volts grade for 3 pin 15 Amps switch socket combination point including running 4.0 Sqmm copper conductor PVC wire as earth continuity conductor on independant board.
16
-
-
... More
Supply and fixing of Modular Switch , 1 module, 6 Amps capacity 230 volts complete all as specified.
92
-
-
... More
Supply and fixing of switch socket combination 2 in 1 multipurpose 2/3 pin 5 amps Modular type complete all as specified.
20
-
-
... More
Supply and fixing switch socket combination 2 in 1 multipurpose 3 pin 5/15 amps Modular type complete all as specified.
16
-
-
... More
Supply and fixing of modular switch 1 way 6A,1 Module
4
-
-
... More
Supply and fixing of Modular socket outlet 6 Amps 2 /3 pin 2 module complete all as specified.
4
-
-
... More
Supply and fixing of fan step regulator , 120W - 2 Module all as specified and directed
8
-
-
... More
Supply and fixing of ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified.
18
-
-
... More
Supply and lay on wall/in ground/on pole ISI marked XLPE insulated armoured, heavy duty, electric cable with aluminium conductors 1100 volts laid in trenches, floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing complete all as specified of size 50 Sqmm , 3.5 core all as specified and directed. ( Main panel to VTPN DB )
224
-
-
... More
Supply and fixing r the medium grade GI tubing of 80 mm dia with including fixing arrangements on wall for XLPE cable protection complete all as specified and as directed
30
-
-
... More
Material and labour for concealed Submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from Panel/DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed. Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length.
(From VTPN TO SPN DB)
73
-
-
... More
Material and labour for concealed Submain wiring with 4 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 32 mm dia including one run of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from Panel/DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed. Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length.
(From VTPN DB to TPN DB FOR AC SOCKET)
45
-
-
... More
Material and labour for concealed Submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from Panel/DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed. Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length.
(From TPN DB to AC socket)
550
-
-
... More
S&F Socket outlet 25A modular with MCB protected as per Cat No CS26403WNR of Make C&S or equivalent for AC 1.5 TR all as specified and directed.
5
-
-
... More
S&F 1 way,single phase 25A Motor Starter for AC AC 1.5 TR as per Cat No CS20366NR of Make C&S or equivalent all as specified and directed.
5
-
-
... More
S & fixing of Vertical type MCCB TPN DB 4 way double door made out of CRCA sheet housing with powder coating flush on walls including cutting chesis and making good disturbed surfaces complete all as specified and directed.
1
-
-
... More
Supply and fixing MCCB 4P, 415V,16KA, 100 amps suitable for Vertical MCCB DB all as specified and directed .
1
-
-
... More
Supply and fix in MCB SP 6 to 32 Amps 240 volts for fixing on MCB DB complete all as specified and as directed.
20
-
-
... More
Supply and replace sheet metal enclosure MCB double door TPN DB 4 way with 415V, 200 Amps busbar made including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface complete all as specified and as directed.
1
-
-
... More
Supply and fix in repair MCB TP 63 Amps 415 volts Capacity "C" Series for fixing on MCB DB complete all as specified and as directed.
1
-
-
... More
Supply and fix in repair MCB TPN 63 Amps 415 volts Capacity "C" Series for fixing on MCB DB.
1
-
-
... More
Supply and replace MCB double door DB SPN 8 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface complete all as specified and as directed.
2
-
-
... More
Supply and fix in repair MCB SPN 40 Amps 240 volts for fixing on MCB DB complete all as specified and as directed.
4
-
-
... More
Supply and Fixing of LED luminaire 600mm X 600mm 35/36W ,220V, AC recessed type with high efficiiency PMMA diffuser soft glare free light complete with drivers ,holders LED lamp suitable for roof ceiling connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed .
10
-
-
... More
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, checknuts and washers all as shown in Electrical Plate No.3 of SSR Part-I and connected to main switch board including excavation and earth work, PCC chamber in 1:3:6, RCC Cover in 1:2:4 type B-1 reinforced with 8 mm dia MS bars at 10 cm c/c, 20 mm dia medium grade GI pipe with funnel and wire mesh complete and watering arrangement all as specified. (Note: GI pipe 15mm dia, GI wire 4mm dia upto 7.5m deemed to be included in quoted rate.)
2
-
-
... More
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc Hot and Cold Water Flexible connection pipe with couplings complete all as specified and as directed.
21
-
-
... More
S&F concealed modular Power unit 25A for Geysors on wall with modular metal box necessary fixing arrangements complete all as specified and as directed. (As per Cat No : CG26405PWNR of make C&S electric or equivalent)
21
-
-
... More
S&F single phase Motor Starter modular type 25A for Geysor all as per cat No: CG20364PWNR/CG23364NR of make C&S electric or equivalent complete all as specified and as directed.
21
-
-
... More
M&L Cutting GI pipe with medium grade of any bore upto 32 mm dia and reducing to required size by inserting Tee and other specials for connection to PPR 20 mm Outer Dia complete all as specified and as directed.
21
-
-
... More
S&F 15 mm inner dia GI Pipe Medium grade Surface/concealed pipes for hot & cold water supply including all fittings like bends, reducers, copupings, sockets, etc. fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed.
350
-
-
... More
S&F CP Stop valves/ Angle valve, 15 mm dia cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
42
-
-
... More
S&F CP Bib taps, 15 mm dia cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
21
-
-