Military Engineer Services Tender

For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date16 Oct 2024
Closing Date20 Nov 2024
Tender Amount₹ 1,40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹44,500/MT*
Telangana

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Returning, filling in, including spreadin, levelling, watering and well ramming in layers not exceeding 25 cm in hard / dence soil complete all as specified and as directed.

33

-

-

... More
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed by Engr-in-Charge complete all as specified and as directed.

73.7

-

-

... More
M&L Plain cement concrete 1:4:8 mix, type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.

8.25

-

-

... More
M&L Formwork to sides of concrete foundations, footings, columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed.

143

-

-

... More
M&L Reinforced cement concrete M-25 (design mix) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, roof slabs,etc.; under-reamed piles and mass concrete complete all as specified and as directed.

35.2

-

-

... More
M&L Formwork to sides of pillars,posts, struts, piers, columns and stanchions complete all as specified and as directed.

136.8

-

-

... More
M&L Reinforced cement concrete M-25 (design mix) in Columns, pillars, piers, posts and struts complete all as specified and as directed.

10.26

-

-

... More
M&L Formwork to sides and soffits offloor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.

154

-

-

... More
M&L Reinforced cement concrete M-25 (design mix) in Beams, cantilevers,bressummers, lintels over 1.5m span complete all as specified and as directed.

20.9

-

-

... More
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings,Chajjas and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed.

196

-

-

... More
M&L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed.

16.5

-

-

... More
M&L Reinforced cement concrete M-25 (design mix) in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, chajjas,deck slabs and in shelves and the like complete all as specified and as directed.

23.52

-

-

... More
M&L Formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing) complete all as specified and as directed.

45

-

-

... More
M&L Reinforced cement concrete M-25 (design mix) in stairways (except spiral staircases)including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings; RCC water tanks upto 1500 litres complete all as specified and as directed.

6

-

-

... More
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.

12100

-

-

... More
M&L Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders includingmild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.

2500

-

-

... More
M&L filling under floors or pavings,Spreading and levelling in layers n exc. 25 cm thick spread, levelled and rammed including watering complete all as specified and as directed.

48

-

-

... More
M&L ATT Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.

160

-

-

... More
M&L ATT Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed.

9.6

-

-

... More
M&L ATT along the external/internal wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed.

74

-

-

... More
M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.

17.51

-

-

... More
M&L 100mm thick plain cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in sub base of floors complete all as specified and as directed.

160

-

-

... More
M & L 25 mm thick PCC (1:2:4) type B0 using 12.5mm graded stone aggregate as in sub base, floor, path, pavings etc.,surface finished fair & even complete all as specified and as directed.

450

-

-

... More
M&L Vitrified light coloured Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc set & jointed in neat cement slurry & pointed in white or coloured cement to match including 15 mm thick screed bed / bedding layer in CM (1:6) complete all as specified and as direcetd.

450

-

-

... More
M&L Vitrified light coloured Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, in Dado / skirting etc set & jointed in neat cement slurry & pointed in white or coloured cement to match including backing coat of 10mm thick in CM 1:4 complete all as specified and as directed.

40.5

-

-

... More
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, platforms, urinal partitions and like in cement mortar (1:4) including cutting to required shape,pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 15 mm thick screed bed/bedding layer in CM (1:6) complete all as specified and as direcetd.

30

-

-

... More
M&L AAC (Autoclave Aerated Concrete) block masonry for 200mm thick walls with blocks size 600mm x 200mm having compressive strength as per IS 2185(part-III) set in chemical mortar of LATICRETE or equivalent as per manufacturers instructions complete all as specified and directed. Make: BIRLS / ULTRATECH / SHREE SHAKTI / PRIME / SIPOREX / GREENWAY BUILDING MATERIALS INDIA PVT Ltd

101.25

-

-

... More
M&L Rendering 15mm thick in CM 1:4 mixed with WPC on other than fair faces of brick work or concrete surfaces on walls finished even and smooth without using extra cement complete all as specified and as directed.

246

-

-

... More
M&L rendering to brick masonry surfaces of walls 10mm thick in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.

213

-

-

... More
M&L rendering to concrete surfaces 5mm thick in cement mortar 1:3 in ceiling finished even and smooth without using extra cement complete all as specified and as directed.

510

-

-

... More
Supply only liquid water proofing compound complete all as specified and as directed.

45.66

-

-

... More
M&L 3mm thick wall care putty on wall surfaces complete all as specified and as directed.

213

-

-

... More
M&L 3mm thick wall care putty on ceiling surfaces complete all as specified and as directed.

510

-

-

... More
M&L applying two coats of Oil bound distemper over a coat of primer on wall surfaces with white or tinted including preparation complete all as specified and as directed.

213

-

-

... More
M&L applying two coats of Oil bound distemper over a coat of primer on ceiling surfaces with white or tinted including preparation complete all as specified and as directed.

510

-

-

... More
M&L Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed.

246

-

-

... More
M & L providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed.

220

-

-

... More
M&L Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including hanging from roof slab complete all as specified and as directed.

510

-

-

... More
M&L Gypsum Board 12mm thick in ceiling fixed with screws as per manufacturers instructions complete all as specified and as directed.

510

-

-

... More
S&F Bonded mineral wool blanket slab made fromb glass density 24 kg/cum and fixed as per manufacturer’s instructions, 25mm thick complete all as specified and as directed.

510

-

-

... More
M&L Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed.

77.76

-

-

... More
S&F Powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and as directed.

30.24

-

-

... More
S&F 125 mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 butt hinges for PVC door frame complete all as specified and as directed.

36

-

-

... More
S&F 200 mm size Alluminium, anodised barrel tower bolts of extruted section and fixed complete all as specified and as directed.

24

-

-

... More
S&F Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and as directed.

12

-

-

... More
S&F 12mm toughened glass, selected quality, in doors complete all as specified and as directed.

15.12

-

-

... More
M&L Prelaminated particle board 12mm thick, interior grade, prelaminated on both sides side with decorative choice lamination fixed with screws to timber frame work complete all as specified and as directed.

15.12

-

-

... More
S&F Factory made UPVC fully sound proof windows / doors including frames / chowkats, shutters, powder coated with vaccume sealed 19mm thick DGU (double glazed unit) glass sliding in 3 tracks, 02 shutters made up double glazing glass 01 shutter with steel wire mesh of aperture not exceeding 1.40mm sliding shutter with all fittings and fixtures and locking arrangements including spacer, drying agent and sealents complete all as specified and as directed.

120

-

-

... More
S&F Steel work as in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc cut to ordinary lengths complete all as specified and as directed.

7052.4

-

-

... More
S&F Steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed.

3621.76

-

-

... More
M&L applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome on new steel surfaces of any description including preparation complete all as specified and as directed.

300

-

-

... More
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed.

350

-

-

... More
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.

30

-

-

... More
M&L 75mm thick Plain Cement concrete type C-1, 1:3:6 (using 20mm graded stone aggregate) as in sub base of floors / plinth protection complete all as specified and as directed.

37.8

-

-

... More
S&F PVC (SWR)110mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.

20

-

-

... More
S&F PVC (SWR) bends of 110mm bore complete all as specified and as directed.

3

-

-

... More
S&F sinks with drainage board made of stainless steel 1.00mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mmbowl size 410mm x 330mm x160mm complete all as specified and as directed.

1

-

-

... More
S&F 30 mm dia bore waste fittings brass chromium plated fixed to wash hand basin / urinals with long screwed shanks and fly nuts flange and bedded in run lead cement and other end fixed complete all as specified and as directed.

1

-

-

... More
S&F 15 mm bore fancy type long body Bib tap crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.

1

-

-

... More
S & F 500 Ltrs capacity Rotational moulded, polythene water storage tanks (cylindrical shape with vertical top closed) hoisted and fixed in position complete all as specified and as directed.

2

-

-

... More
S&F 20 mm bore dia ball valves, high pressure of PTMT with epoxy coated aluminium rod & high dencity plasstic ball screwed for iron pipe and fixed .(minimum weight 15 mm-142gms/20mm-210gms) complete all as specified and as directed.

2

-

-

... More
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 20 mm bore pipe complete all as specified and as directed.

2

-

-

... More
S&F steel water tubing 15 mm bore medium grade galvanized with all fittings such as bends, tees, nipples, elbows, reducers, etc, fixed complete to walls and ceilings or laid in floors in repairs including concealed piping after cutting in brick work/ stone masonry walls where ever required complete all as specified and as directed.

20

-

-

... More
All as per item No 66 above but 20mm dia -ditto-

25

-

-

... More
S&F 25mm thick preformed filler for expansion/crumple joints including making good and removal/ fixing of metal sheet on wall complete all as specified and as directed.

6.8

-

-

... More
M&L Providing cast-in-situ reinforced cement concreteType B1 1:2:4 (using 20mm graded aggregate) in copings,columns, etc including necessary form work (straight or curved), including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.

1.02

-

-

... More
M&L Mild steel TMT bars 6 mm to 8 mm dia and cut to length, bent to shape required including crancking , bendding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as speified and as directed .

200

-

-

... More
SCHEDULE 'A' FOR ADDN / ALTN / IMPROVEMENT :- M&L Demolition of concrete of any description and in any position including plastering and leeping (whether full thickness including textile coverings, bitumen felt on roofs removed or only a part thereof) for complete all as specified and as directed.

16

-

-

... More
Roughening surfaces of old concrete roof / floor surfaces by picking, sweeping clean and washing down with water to remove dust,etc complete all as specified and as directed.

320

-

-

... More
M & L Brushing neat cement slurry with 3.0 kg of cement per square metre on old concrete surfaces complete all as specified and as directed.

320

-

-

... More
M & L average 40mm thick PCC 1:2:4 mix, type B0 (using 12.50mm graded stone aggregate) for roof padding concrete complete all as specified and as directed.

320

-

-

... More
M&L 10mm thick rendering on fair faces of brick work (or) concrete surfaces in CM 1:3 mixing water proofing compound at 2% by weight of cement finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC will be measured and paid in appropriate of item.

320

-

-

... More
Supply only liquid water proofing compound.

53.82

-

-

... More
M&L cleaning the roof, plastered surfaces and applying evenly a priming coat of bitumen primer at the rate of 1.2 kg per Sqm and providing APP based polymeric modified water proofing membrane minimum weighing 3kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/Sqm) laid on primed surface by forced application and applying two coats of solar reflective bituminous aluminium paint @ 0.1 kg/Sqm per each coat complete all as specified and as directed.

320

-

-

... More
Demolition of RCC in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed.

11.37

-

-

... More
Demolition of Plain cement concrete of any description including tiles in any position not otherwise specifically provided for complete all as specified and as directed.

15

-

-

... More
M & L 25 mm thick PCC (1:2:4) mix, Type B0 using 12.5mm graded stone aggregate as in sub base, floor, path, pavings etc surface finished fair & even complete all as specified and as directed.

317.55

-

-

... More
M&L Vitrified light coloured Ceramic tiles 10 mm thick (square / rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc set & jointed in neat cement slurry & pointed in white or coloured cement to match including 15 mm thick screed bed / bedding layer in CM (1:6) complete all as specified and as direcetd.

300

-

-

... More
M&L Vitrified light coloured Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, in Dado/ skirting etc set & jointed in neat cement slurry & pointed in white or coloured cement to match including backing coat of 10mm thick in CM 1:4 complete all as specified and as directed.

27

-

-

... More
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, platforms, urinal partitions and like in cement mortar (1:4) including cutting to required shape,pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 15 mm thick screed bed/bedding layer in CM (1:6) complete all as specified and as direcetd complete all as specified and as directed.

17.55

-

-

... More
M&L rendering to brick masonry wall surfaces 15mm thick in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.

48

-

-

... More
M&L 3mm thick wall care putty on wall surfaces complete all as specified and as directed.

48

-

-

... More
M&L 3mm thick wall care putty on ceiling surfaces complete all as specified and as directed.

555

-

-

... More
M&L applying two coats of Oil bound distemper over a coat of primer on wall surfaces with white or tinted including preparation complete all as specified and as directed.

48

-

-

... More
M&L applying two coats of Oil bound distemper over a coat of primer on ceiling surfaces with white or tinted including preparation complete all as specified and as directed.

555

-

-

... More
Demolition of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including frame work,cover fillets complete all as specified and as directed.

555

-

-

... More
M&L Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including hanging from roof slab complete all as specified and as directed.

555

-

-

... More
M&L Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and as directed.

555

-

-

... More
S&F Bonded mineral wool blanket slab made fromb glass density 24 kg/cum and fixed as per manufacturer’s instructions, 25mm thick complete all as specified and as directed.

555

-

-

... More
Demolition of Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.

14.4

-

-

... More
Taking down Chowkhats or frames with shutters exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and as directed.

8

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for struts, any size complete all as specified and as directed.

10

-

-

... More
S&F Steel work as in tubular / L post trusses including special shaped washers etc, complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St 240 complete all as specified and as directed.

1300

-

-

... More
M&L applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome on new steel surfaces of any description complete all as specified and as directed.

100

-

-

... More
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated / semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.

160

-

-

... More
M&L Removing excavated material/ spoil exc. 1.50 km but n exc. 5 km and depositing where directed and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.

15

-

-

... More
Dismantling of 500 Ltrs capacity water tanks complete all as specified and as directed.

2

-

-

... More
Taking down steel tubing and connections 15 mm bore complete all as specified and as directed.

30

-

-

... More
All same as per item No 101 here in before but 20 mm bore -ditto-

20

-

-

... More
SCHEDULE 'A' FOR INTERNAL ELECTRIFICATION :- Taking down copper/ aluminum point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, lamp holders, light fittings etc removing materials for taking credit and making good disturbed surfaces of walls, floors etc. including paint tuch up to match with the existing surface as per site requirement complete all as specified and as directed.

162

-

-

... More
Taking down existing unserviceable distribution board with MCBs, switch fuse unit, enclosureand making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed.

17

-

-

... More
Taking down Existing old UNSV submain wiring of any description /type size and removal of UNSV material from site and making good the disturbed surface of walls / ceiling so as to match with the existing finishes complete all as specified and as directed.

150

-

-

... More
M&L for point wiring with 1.5 sq.mm FRLS insulated multistranded copper conductor, 1100 volts grade single core PVC insulated and unsheathed cable drawn through new PVC conduit/ casing capping of suitable size but not less than 20 mm dia in consealed of stone/concrete wall /roof etc all as per site requirement including FRLS,PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour coding and pressed steel terminal boxes / modular boxes made out of 1.6 mm thick MS sheet with sink into the wall for mounting, 60 mm deep covered including laminated sheet, required sizes switch modular covers or 3 mm thick laminated hylam sheet fixed with cadmium plated screws/ PVC gang box fully enclosed type for mounting switches, sockets, fan regulator, etc including making good the disturbed surfaces of walls and paint tuch up to match with the existing surfaces as per site requirement complete all as specified and as directed.

-

-

-

... More
One light point controlled by one switch complete all as specified and as directed.

184

-

-

... More
One 3 pin 6 Amps socket point controlled by one switch on same board complete all as specified and as directed.

76

-

-

... More
One 3 pin 6 Amps socket point controlled by one switch on independent board complete all as specified and as directed.

110

-

-

... More
All as per item No 106 here-in-before but with 2.5 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and as directed.

99

-

-

... More
S&F in replacement of switch Modular type single pole one way 6 Amps 240 volts complete all as specified and as directed complete all as specified and as directed.

376

-

-

... More
S&F in replacement of socket 2 in 1, 3 pin 6 Amps, modular type, universal 240 volts complete all as specified and as directed

186

-

-

... More
S&F in replacement of switch Modular type single pole one way 16 Amps 240 volts complete all as specified and as directed.

99

-

-

... More
S&F in replacement of socket 2 in 1, 3 pin 6/16 Amps, modular type, universal, 240 volts complete all as specified and as directed.

99

-

-

... More
S&F in replacement of ceiling rose 6 A, 3 plate,PVC / polycarbonate, insulated body 240 Volt , 50 Hz complete all as specified and as directed.

190

-

-

... More
M&L submain wiring alongwith earth wire with 3 x 6.0 Sqmm FRLS PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC Conduit/ casing capping maintaning the colour coding as per electric rules and all required accessories of suitable size consealed on wall / roof complete all as specified and as directed. Note: Three runs of 6.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length.

120

-

-

... More
All as per item No 113 here-in-before but with 3 x 4.0 sqmm FRLS PVC insulated copper conductor cable complete all as specified and directed. Note: Three runs of 4.0 Sqmm copper cable and one run of PVC conduit / casing capping shall be measured as one unit length.

930

-

-

... More
All as per item No 113 here-in-before but with 5 x 10.0 sqmm FRLS PVC insulated copper conductor cable complete all as specified and as directed. Note: Five runs of 6.0 Sqmm copper cable and one run of PVC conduit / casing capping shall be measured as one unit length.

120

-

-

... More
S&F MCB distribution board double door type vertical load line TPN 12 way DB without MCCB sheet steel powder painted with bus bar ,neutral link & earth bar etc.with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing circuit complete all as specified and as directed.

1

-

-

... More
S&F MCB distribution board double door type TPN 04 way sheet steel powder painted with bus bar ,neutral link & earth bar etc.with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing circuit complete all as specified and as directed.

4

-

-

... More
S&F of MCCB, 3 pole adjustable type, 415 V, 250 Amps with breaking capacity of 36 KA complete all as specified and as directed.

1

-

-

... More
S&F MCB Triple pole and Neutral (TPN) of capacity 40-100 Amps 415 volts ,breaking capacity 10 KA,'C' series ,fixed in proper position complete all as specified and as directed.

4

-

-

... More
S&F MCB, SPN, 40-63 Amps, 240 Volts complete all as specified and as directed.

12

-

-

... More
S&F MCB , SP, 6 - 32 Amps, 240 Volts complete all as specified and as directed.

60

-

-

... More
S&F in replacement of high efficacy recess luminaire suitable for armstrong / grid ceiling with high brightness LEDs and PMMA extrured diffuser giving glare free light and good aesthetic appeal 35 / 36 W LED (2ft X 2ft) complete with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make:- Havells / Philips / Bajaj

156

-

-

... More
S&F in replacement of high efficacy Recess mounted downlighter with pressure die-cast aluminium heat sink & PC diffuser in white powder coated finish with integral electronic low THD (10%) LED driver 18 W LED, Ceiling cutout: Ø 175 mm, height 90 mm complete with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make :- Cat Part No - INTEGRANEODLR18WLED865S of Havells or equivalent make in Philips / Bajaj.

8

-

-

... More
S&F wall mounted E-Lite LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 10W LED 6500K (2ft) complete with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete including taking down old U/s fittings complete all as specified and as directed. Make:- Havells / Philips / Bajaj

4

-

-

... More
S&F exhaust fan, steel body AC single Phase. 230V of size 300 m sweep with, blades, and frame and louvers including all fixing accessories complete all as specified and as directed. Make:- Havells / Usha / Bajaj

2

-

-

... More
M&L cutting round holes suitable for fixing exhaust fan of size 300 mm into or through stone walls built in cement mortar or cement lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required and plastering in CM 1:4 to external / internal surfaces and finished to match with the existing surfaces complete all as specified and as directed.

2

-

-

... More
Disconnecting and refixing after repair of ceiling fan of any sweep any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, including replacement of wornout/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan including painting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc & testing complete all as specified and as directed.

2

-

-

... More
Disconnecting and refixing after repair of Exhaust fan of any sweep any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan including painting of exhaust fan complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc & testing complete all as specified and as directed.

4

-

-

... More
S&F in replacement of louvers with suitable frame work and fixing arrangements for exhaust fan of any size sweep complete including removing the existing unserviceable one complete all as specified and as directed.

2

-

-

... More
S&F in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified and as directed.

2

-

-

... More
M&L GI Pipe Bracket made out of Galvanised Iron Tubing 40mm bore (dia), light grade, 1.50 Metre long bent to shape as per specified for fixing Street Light Fitting including suitable size of clamps and applying Two coats of Aluminium Paint over a coat of Aluminium Primer including taking down old unserviceable GI Pipe Bracket with clamps complete all as specified and as directed.

2

-

-

... More
S&F sheet metal powder painted double pole enclosure with a two pin and earth plug and socket flushing in wall including 20 Amps rated double pole MCB 10 KA, "C" curve complete all as specified and as directed.

38

-

-

... More
M&L Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron or steel earth lead strip 32x6 mm size upto 7.5 mtr long in single length by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 5 of SSR part I including necessary excavation in hard/dense soil and earth work GI pipe 20mm dia mediumj grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to LT panel board as indicated including testing and taking down old u/s earthing complete all as specified and as directed.

6

-

-

... More
S&F wall mounting fans of dia 300 mm, 240 V complete including all accessories for fixing complete all as specified and as directed.

43

-

-

... More
M&L Earth continuity GI strip 32X6 mm with saddles and fixing screws etc fixed to wall on batten/porcelain insulator or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing including breazing at each necesasry joints etc. complete all as specified and as directed.

60

-

-

... More
M&L earthing pit display boards made out of 3mm thick MS sheet of size 30 x 35cm welded to 75cm long 25 x 25 x 5 mm thick MS angle iron grouted in PCC 1:3:6 (with 20mm stone aggregate) to a depth of 20 cm and applying two coats of synthetic enamel paint of approved color over a coat of red oxide primer and writing the letters on plate for showing the following details: 1. EARTHING PIT NO : 2. DATE OF MEASUREMENT : 3. NEXT DUE DATE : 4. STANDARD VALUE : 5. VALUE OBTAINE : 6. MEASURED BY : 7. SUPERVISED BY : Note : Shape, size and colour of display board should be approved by Engr in Charge before fixing at site.

6

-

-

... More
Taking out ACs from site and depositing to E/M Store yard with complete accessories and refixing to the building after completion of the repair works including maintenance of the complete AC indoor unit and out door unit including filling of the Gas if required at the time of commissioning of the unit. The quoted rates will be inclusive of replacement of the items damaged by the labour during desmantaling or transpotation complete all as specified and as directed.

20

-

-

... More
SCHEDULE 'A' FOR EXTERNAL ELECTRIFICATION :- Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 150 sqmm 3.5 core complete all as specified and as directed.

100

-

-

... More
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft / loose soil complete all as specified and as directed.

22

-

-

... More
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.

13.3

-

-

... More
Removing excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point in soils complete all as specified and as directed.

7.25

-

-

... More
M & L spreading cleaned dry river sand filling in trenches for cushioning of LT/HT cables punning after filling complete all as specified and as directed. Note : Punned thickness shall only be measured and paid

6.5

-

-

... More
Supply and lay un-reinforced precast concrete cable cover , class LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables complete all as specified and as directed.

500

-

-

... More
SCHEDULE 'A' FOR AIR CONDITIONING & REFRIGERATION :- Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity of 1.5 TR complete including wall mounting bracket / channel and all accessories required for installation complete all as specified and as directed.

3

-

-

... More
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity of 2 TR complete including all accessories required for installation complete all as specified and as directed.

5

-

-

... More
S&F sheet metal powder painted double pole enclosure with a two pin and earth plug and socket flushing in wall including 20 Amps rated double pole MCB 10 KA, "C" curve complete all as specified and as directed.

8

-

-

... More
S&F voltage stabilizer for voltage regulation input 150 - 285 V out put voltage 240 (+/- 2%) suitable for AC of capacity 5 KVA having protection like over and under voltage, surge protection and over load protection complete including all accessories required for installation complete all as specified and as directed. Make : V-Guard VDI 400 Or equivalent

8

-

-

... More
SCHEDULE 'A' FOR SPECIAL ITEM OF E/M WORK :- Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity of 1.5 TR complete including wall mounting bracket / channel and all accessories required for installation complete all as specified and as directed.

6

-

-

... More
S&F sheet metal powder painted double pole enclosure with a two pin and earth plug and socket flushing in wall including 20 Amps rated double pole MCB 10 KA, "C" curve complete all as specified and as directed.

6

-

-

... More
Supply and install voltage stabilizer for voltage regulation input 150 - 285 V out put voltage 240 (+/- 2%) suitable for AC of capacity 5 KVA having protection like over and under voltage, surge protection and over load protection complete including all accessories required for installation complete all as specified and as directed. Make : V-Guard VDI 400 Or equivalent

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.