For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date18 Feb 2025
Closing Date24 Mar 2025
Tender Amount₹ 24,50,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹45,500/MT*
Telangana

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Design and Construction of Living Accn for Pump Operator with Toilet including Labaratory (01 No) with permanent specification having Plinth Area of 37.00sqm each with RCC framed construction using M-25 (Design Mix) in foundation concrete, footings, plinth beam, Columns, lintel, roof beam, roof slab, PCC Solid Block walling, pre-constructional ATT, 10mm thick Internal plastering in CM 1:6 & 15mm thick External plastering in CM 1:4, 5mm thick ceiling plastering in CM 1:3, finishing internal surface with 3 coats of white wash & external surface with 2 coats of cement based , WPT to roof with elastomeric membrane treatment, Rolling Shutter,

1

-

-

... More
Pressed steel door frame with flush shutter, glazed skelton door shutter, fly proof box type steel windows with MS guard bars, PVC door, 7 to 9mm non-skid rectified ceramic tiles flooring set and jointed in cement slurry over 20mm thick screed in CM 1:4 over PCC 1:2:4 type D2 sub-base, sanitary fittings & taps in toilets, plinth protection necessary excavation in all types of strata, refilling of earth and disposal of surplus earth within 500m lead, all soil waste pipe up to first manhole, etc., complete all as specified and as directed. Note : All Volvs pumps, pipelines & internal electrification will be measured under items at respective schedules.

-

-

-

... More
Design (hydraulically, structurally and aesthetically) and construction of RCC Sump (Lift well No.2 at Zone III) for avg flow of waste upto 50 cum/ day (2.0m inner dia and 6.0m overall depth) with M-30 design mix foundation concrete, sump walls, bottom & top slab, top slab with CI manhole covers, plastering, water proofing as per zonal specification, epoxy paint inside, Superstructure of pump room with PCC Solid Block walling, Internal & External plastering, finishing, RCC roof slab, Roof Treatment, Anti termite treatment all as per Zonal Specification, Floor tiling, PVC door, Flooring, etc., all as per zonal specification including including necessary excavation in any type of strata, refilling of earth and disposal of surplus earth within 50m lead, all piping connections, valves, internal electrification, MS ladder, ventilation shaft, BB chambers with 5m of outer wall of tank complete including test for water tightness and hydraulic functioning complete all as shown on drawings as specified and as directed.

1

-

-

... More
All as per Item No.3 above but Lift Well No.3 at Zone III

1

-

-

... More
All as per Item No.3 above but Lift Well No.4 at Zone III

1

-

-

... More
All as per Item No.3 above but Lift Well No.5 at Zone III

1

-

-

... More
All as per Item No.3 above but Lift Well No.1 at Zone IV

1

-

-

... More
All as per Item 3 above, but RCC Sump (Lift Well No.1 at Zone I) for avg flow of waste upto 101 to 200cum/day (2.5m inner dia and 7.5m overall depth)

1

-

-

... More
All as per Item 3 above, but RCC Sump (Lift Well No.2 at Zone I) for avg flow of waste upto 201 to 300cum/day (3.0m inner dia and 8.0m overall depth)

1

-

-

... More
All as per Item 3 above, but RCC Sump (Lift Well No.1 at Zone III) for avg flow of waste upto 201 to 300cum/day (3.0m inner dia and 8.0m overall depth)

1

-

-

... More
GENERAL SUMMARY NOTE : Schedule ‘A’ Part II to XII are under Ser No. 11.00 to 21.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.

-

-

-

... More
Lumpsum price worked out by the tenderer for SITE CLEARANCE as listed in Schedule ‘A’ Part-II

1

1642305

-

... More
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III

1

51255

-

... More
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-IV

1

137999

-

... More
Lumpsum price worked out by the tenderer for EXCAVATION AND EARTH WORK as listed in Schedule ‘A’ Part-V

1

36927258

-

... More
Lumpsum price worked out by the tenderer for ROAD/ PATH as listed in Schedule ‘A’ Part-VI

1

3237678

-

... More
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII

1

62011956

-

... More
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VIII

1

1250943

-

... More
Lumpsum price worked out by the tenderer for COMPOUND WALL & GATE as listed in Schedule ‘A’ Part-IX

1

5694387

-

... More
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY/ TREATED WATER SUPPLY as listed in Schedule ‘A’ Part-X

1

4264984

-

... More
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-XI

1

4734240

-

... More
Lumpsum price worked out by the tenderer for PRESSURIZED SEWAGE (E/M) as listed in Schedule ‘A’ Part-XII

1

141861

-

... More
SCHEDULE `A' PART - XIII to XVII are not prepriced by MES and prepriced rates indicating 0.00 under column 5 signifies this fact only. Bidders shall insert their rates in Green field under Col-6.

-

-

-

... More
SCHEDULE 'A' PART XIII - STAND BY DG SET

-

-

-

... More
Supply, install, testing and commissioning of Non clog vertical submersible pumps with chrome steel impeller and cutter, non-clog to pass 40mm size particles, Minimum flow rate of 220 LPM at 16m head (2 working + 1 stand by), Delivery Size 80mm dia including necessary electric connection from control panel, SS lifting chain not less than 10m, etc., complete all as specified and directed (For IMLW 2 at Zone 1). Note : Pump sets selected must ensure compatibllity with SCADA operation & relevant provision in respective of LT Panel given in Ext Electric Supply BOQ.

3

-

-

... More
Supply, install, testing and commissioning of Non clog vertical submersible pumps with chrome steel impeller and cutter, non-clog to pass 40mm size particles, Minimum flow rate of 240 LPM at 16m head (1 working + 1 stand by), Delivery Size 80mm dia including necessary electric connection from control panel, SS lifting chain not less than 10m, etc., complete all as specified and directed (For IMLW 1 at Zone 1). Note : Pump sets selected must ensure compatibllity with SCADA operation & relevant provision in respective of LT Panel given in Ext Electric Supply BOQ.

2

-

-

... More
All as per Item No 24 but of 400 LPM at 16m head and delivery pipe size 80mm complete (For IMLW 1 at Zone 3 & IMLW 2 at Zone 5) all as specified and as directed.

4

-

-

... More
All as per Item No 24 but 60 LPM at 16m head and delivery pipe size 50mm complete (For IMLW 2 at Zone 3) all as specified and as directed.

2

-

-

... More
All as per Item No 24 but of 25 LPM at 16m head and delivery pipe size 50mm complete (For IMLW 3 & 4 at Zone 3) all as specified and as directed.

4

-

-

... More
All as per Item No 24 but of 10 LPM at 16m head and delivery pipe size 50mm complete (For IMLW 1 at Zone 4) all as specified and as directed.

2

-

-

... More
S&F Ductile Iron pressure pipes, class K7, centrifugally cast with spigot and socket ends 100mm dia conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, etc., complete all as specified and as directed for the following sizes:-

1750

-

-

... More
Notes :- (a) Quoted rates inclusive of Lead Joints/ D-Joints/ push on joint required during laying of pipes only DI specials will be measured and paid separately under relivant items. (b) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the Engineer-in- Charge, if required. (c) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.

-

-

-

... More
(d) Civil road croossing to be done necessary permission for crossing road/ laying of pipe form GHMC/ Cantt Board/ Any other civil department including necessary fee if any applicable is the responsibility of the contractor. NO Claim in this regard will be entartained during execution stage. Department only assit for obtaining approval. (e) Contractor should visit the site to understand the site condition before quoting the rates . No claim regarding site condition will be entertain during execution stage.

-

-

-

... More
S&F DI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket, etc.,) tee pieces, single 'Y' branch, double branch cross (all sockets, socket and spigots, collars, cap plugs, etc., up to 150 mm bore complete all as specified and directed.

500

-

-

... More
S&F Sluice valve 100 mm dia both ends flanged with CI body, ISI marked, IS 14846, pressure PN 1.6 with SS spindle with clamps and check nuts, operating hand wheel complete all as specified and directed.

8

-

-

... More
S&F, connecting and testing of Ductile Iron non return (Reflux) valves flanged ends in swing type design IS-5312 part-I, PN-1.6 s Gun metal both ends flanged etc including jointing materials of sizes complete of following sizes all as specified and directed.

-

-

-

... More
80 mm dia

9

-

-

... More
50 mm dia

6

-

-

... More
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 m in depth and getting out in hard/dense soil for removing/ laying of pipe line complete all as specified and directed.

650

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed.

585

-

-

... More
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.

65

-

-

... More
Supply and laying steel water tubing medium grade, galvanised with all fitting, laid in trenches and testing for leakages complete all as specified and directed for the following sizes :-

-

-

-

... More
50 mm dia

30

-

-

... More
80 mm dia

50

-

-

... More
Cutting the existing road of any kind straight by manual, depth and width not less than 30cm for pipes up to 100mm dia for pipes and filling back with excavated soil up to 75% road portion and 25% shall be made with cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate complete all as specified and directed.

40

-

-

... More
SCHEDULE 'A' PART XIV- SEWAGE TREATMENT PLANT

-

-

-

... More
Design, Supply Construction, Installation and Testing & Commissioning of Sewage Treatment Plants (STP) based on principle of aerobic attached growth non-clogging randomly moving bed Bio-reactor Technology (MBBR) as per the given specifications and drawings having the capacities given below including all civil works, mechanical works, pumps, blowers, chemical dozers & piping works, electrical works, LT Panel, cabling & instrumentation works, fabrication works, Human intervention free automation of pumping at various stages & SCADA including On line Continuous Effluent Monitoring System (OCEMS) for monitoring of treated water parameters, all types of instrumentation & Data cabling and all other allies works so as to achieve the required parameters in accordance with the latest engineering practice complete all as specified and as directed.

1

-

-

... More
Note : Detailed scope of work under this item along with specifications from the collection sump to various stages of STP up to storage of treated water & final treatment of sludge including automation & SCADA are specified in Annex-‘I’ and Main scope of work covered in this item as under :- (a) 26 KLD STP (Package Type) – 01 Number (b) 250 KLD STP – 01 Number (c) 500 KLD STP – 01 Number (d) 850 KLD STP – 01 Number (e) OCEMS – 01 Number at each STP (f) SCADA System for all above STPs with local server (no cloud hosting is permissible)– 01 Number with two display monitors at GE and AGE Office.

-

-

-

... More
Notes :- (i) Design/ drawing/ BOM of the complete Sewage Treatment Plant including foundation details showing the dimensions shall be obtained from OEM/ Authorized Supplier strictly keeping in view the actual ground/ site requirement and the same shall be got approved from IIT/ NIT before placing final order to the manufacturer. (ii) Any missing of items technically required for efficient working of the plant shall be deemed to be included in the quoted rates. (iii) The contractor is required to visit the site prior to quoting of the subject item so as to ascertain the actual ground requirement w.r.t. issues on foundation, disposal, etc,. Any further query at a later date shall not be entertained & responsibility of the same shall rest with the contractor. (iv) The rate quoted shall be deemed to be inclusive of the mandatory factory testing of the Sewage Treatment Plant before dispatch and final pre-commissioning tests to be carried out in the presence of IEM or rep detailed by the Accepting Officer prior to taking over by MES. (v) The rate quoted shall be deemed to be inclusive of the mandatory NOC for consent to establish & consent to operate STPs from SPCB. (vi) All pumps should be provided with suitable rain protection cover.

-

-

-

... More
(vii) Operation and Maintenance charges to be paid separately. (viii) Process automation of STPs as well as all the intermediate Lift wells or Sewage pumping stations is to be done & also to be integrated with SCADA system and it’s cost is deemed to be included in quoted rates. Details of all the process automation required are coverd in Annex-‘I’. (ix) The cost of each item of SCADA and Automation shall also be attached at the time of quoting the tender to arrive at pricing in case of some addition/ reduction at site.

-

-

-

... More
SCHEDULE 'A' PART XV- LABORATORY ITEMS

-

-

-

... More
Supply, install, testing and commisioning of lab Stirrer complete all as specified and as directed.

4

-

-

... More
Supply, install, testing and commisioning of centrifuge complete all as specified and as directed.

1

-

-

... More
Supply, install, testing and commisioning of PH Meter complete all as specified and as directed.

1

-

-

... More
Supply, install, testing and commisioning of Turbidity Meter complete all as specified and as directed.

1

-

-

... More
Supply, install, testing and commisioning of Titration complete all as specified and as directed.

2

-

-

... More
Supply, install, testing and commisioning of Colorimeter complete all as specified and as directed.

1

-

-

... More
Supply, install, testing and commisioning of Autoclave complete all as specified and as directed.

1

-

-

... More
Supply, install, testing and commisioning of Analytical balance complete all as specified and as directed.

1

-

-

... More
Supply, install, testing and commisioning of Desiccators complete all as specified and as directed.

1

-

-

... More
Supply, install, testing and commisioning of Hot air oven complete all as specified and as directed.

1

-

-

... More
Supply, install, testing and commisioning of Water Bath complete all as specified and as directed.

1

-

-

... More
Supply, install, testing and commisioning of Samples complete all as specified and as directed.

2

-

-

... More
Supply, install, testing and commisioning of Frost free Refrigerator, electric driven 230V, 50 Hz, working on R-134(a) or superior environment refrigerant, puff insulated body, BEE 5 star rated having nominal storage capacity not less than 200 Ltrs complete all as specified and as directed.

1

-

-

... More
Supply, install, testing and commisioning of COD Sensor/ Probe complete all as specified and as directed.

1

-

-

... More
Supply, install, testing and commisioning of DO Sensor/ Probe complete all as specified and as directed.

1

-

-

... More
SCHEDULE 'A' PART XVI- FIRE FIGHTING ITEMS

-

-

-

... More
Supplying and fixing of non-skid rubber mat 16mm thick and 900mm width as required including cutting to required lengths of approved make with Test Certificates for LT Panels complete all as specified and as directed.

16

-

-

... More
Supplying and fixing of fire bucket painted red and duly filled with sand conforming to IS: 2546-1974 complete all as specified and as directed.

32

-

-

... More
Supplying and fixing of MS stand suitable for supporting two buckets (Pedestal type) complete all as specified and as directed.

8

-

-

... More
Supplying and fixing of MS stand suitable for supporting four buckets (Pedestal type) complete all as specified and as directed.

4

-

-

... More
Supplying and fixing of shock restoration chart written in English and Hindi duly framed in as required complete all as specified and as directed.

12

-

-

... More
Supply & Fixing of 4.5Kg, CO2 Type Fire Extinguisher Easy Weight Management, Used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg, Empty Weight 14.6 Kg, Can Height 860MM, Diameter 140MM, Discharge time minimum 13 Secs, Controllable discharge mechanism, Range minimum 2 Meters, Applicable on Class B,C & electrically started Fire, B Rating 13B, Can Construction : Hot Spinning/ Forging, Valve Construction : Forging & Machining, Internal complete all as specified and as directed.

12

-

-

... More
Supplying and fixing of first aid box as approved complete with standard kit as prescribed by Indian Red Cross complete all as directed and specified.

12

-

-

... More
Providing and fixing M.V. danger notice plate of 200mm X 150mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required complete all as directed and specified.

12

-

-

... More
SCHEDULE 'A' PART XVII- MISCELLANEOUS ITEMS

-

-

-

... More
INTERNAL ELECTRIC SUPPLY

-

-

-

... More
M&L for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FRLSH unsheathed 1100Volts with multistranded Copper conductor conforming to IS:694(1990) with ISI marking (for Phase, Neutral and Earth) in and including Non metalic PVC rigid conduit medium grade with ISI mark of size 20mm dia with all accessories concealed in wall/ceiling/ floor/roof , etc., with cast iron/ pressed steel terminal box of suitable sizes & 1.6mm thick duly painted inner & outside by anti-corrosive paint, etc., for mounting modular switches, sockets, fan regulator, etc., with 3mm thick plastic laminated sheet cover with brass screw, cup washer, etc., complete all as specified and directed for the following:- Notes : (i) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. (ii) Modular flush boxes and Modular cover plate shall be measured and paid separately. (iii) Wiring from the DB (distribution box) to switch shall be deemed to be inclusive in the quoted rates. (iv) Sunken modular flush sheet metal enclosures & modular cover plates shall be deemed inclusive in the quoted rates.

-

-

-

... More
One light/ fan point controlled by one switch.

60

-

-

... More
One 3 Pin modular socket 5/6 Amps outlet on independent board

13

-

-

... More
One 3 Pin modular socket 5/6 Amps outlet on same board

5

-

-

... More
All as per Item No. 64 above but with 4Sqmm (for Phase and Neutral) PVC insulated unsheathed multistranded, Copper conductor FRLSH cable of 1100V grade including provn of 4sqmm PVC insulated unsheathed Copper conductor cable of green colour for earth continuity and connecting to common earth dolly, etc., for one 3 pin switch socket outlet (plug point) 15Amps switch socket combination on independent board incl continuous earth wire connecting to common earth and earth dolly complete all as specified and directed.

10

-

-

... More
Supply, install, testing & commissioning of Exhaust fan, metal body with automatic back shutter louvers 250mm sweep, single phase, 240 Volts, AC, 50 Hz all as per Cat No. Ventil Air - DS of Havells or techno-commercially equivalent of other specified makes including cutting hole in to the wall and making good the disturbed surfaces and connecting up complete and provision of cable 3/2 core of suitable size from ceiling rose to fan in flexible hose, etc., complete all as specified and as directed. Note : The unit rate quoted shall be deemed to include the cost any framework/cement work/wood work/ welding work, etc., required for proper fixing of the exhaust fan and matching to the existing surface.

4

-

-

... More
S&F 20 Watts surface/ wall mounted LED batten having PC diffuser, luminous efficacy of minimum 100 lumen/ W, CRI 80, PF 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD 20%, surge voltage protection and other safety tests as per IS:15885 (Part-2/Sec-13) - 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP:20 protection, input voltage range : 140-270 Volts, input frequency 50-60 Hz including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.

22

-

-

... More
All as per Item No 15.00 above but 10 Watts

4

-

-

... More
S&F LED Bulb, 9 Watts, B22, BEE star rated with minimum 3 star rating complete all as specified and as directed.

4

-

-

... More
S&F 35 Watts security light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 110 lumen/ Watt, integral SMPS based constant current electronic LED driver with THD 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13)- 2012, IP:66 protection, high effiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance,

20

-

-

... More
separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, wall mounting with bracket arm OD 35mm to 42mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5m long bracket, having 40mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete in all respect as specified and directed.

-

-

-

... More
Material and labour for Earthing complete with 6.0mm thick galvanized steel earth plate electrode of size 600mm x 600mm, burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level, surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt, filling in alternate layer and earth plate connected to galvanized iron earth wire of 4mm dia as earthing conductor by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical Plate No.3 of MES Schedule (Part I) (2009) connected to earth test point/ main switch/ DB all as specified including testing on completion with and including 15mm bore medium grade GI protection pipe upto 7.5 meter long for GI earth wire including PCC (1:3:6), type C-1 pit with 40mm thick precast RCC (1:2:4), type B -1 cover reinforced with 12mm dia MS bars @ 150mm c/c both ways with lifting hooks made out of 12mm dia MS bars, wire mesh funnel with watering pipe 20mm dia medium grade, as specified including necessary excavation and earth work in any type of soil etc., complete all as specified and as directed.

12

-

-

... More
Note : The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 6 mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI wire length up to 7.50m)

-

-

-

... More
SEWAGE DISPOSAL

-

-

-

... More
S&F for HDPE DWC Pipe 150mm ID SN-8 (IS:16098 II) 6.0m length laid in trenches and jointed in collars complete all as specified and as directed.

24280

-

-

... More
S&F for HDPE DWC Pipe 200mm ID SN-8 (IS:16098 II) 6.0m length laid in trenches and jointed in collars complete all as specified and as directed.

4000

-

-

... More
S&F for HDPE DWC Pipe 250mm ID SN-8 (IS:16098 II) 6.0m length laid in trenches and jointed in collars complete all as specified and as directed.

1400

-

-

... More
M&L for fixing PVC coated MS Rungs (with 12mm dia TMT bar) for septic tank and manhole complete all as specified and as directed.

3000

-

-

... More
M&L for construction of Flush Tank of size 01mtr x 01mtr x01mtr with PCC block masonry walls including PCC bed, CI manhole cover, plastering, PVC coated MS Rungs, inlet & outlet, necessary earth work, excavation, etc., complete all as shown on drawings and as specified.

110

-

-

... More
EXTERNAL WATER SUPPLY/ TREATED WATER SUPPLY

-

-

-

... More
S&F PP-R gate valves (brass insert) of size 90mm bore complete all as specified and as directed.

10

-

-

... More
M&L for construction of valve chamber 90x90x90cm inner dimensions, brick masonary in CM 1:4 including PCC 1:3:6 of 75mm thick in bed, plastering 15cm thick in CM 1:4 in inner walls, coping, MS cover 3mm thick fabricated with Iron frame using 40x40x6 mm size angle iron with hinges and locking arrangements duly painted, excavation, earth work, etc., complete all as specified and as directed.

10

-

-

... More
M&L for construction of valve chamber 60x60x60cm inner dimensions, brick masonary in CM 1:4 including PCC 1:3:6 of 75mm thick in bed, plastering 15cm thick in CM 1:4 in inner walls, coping, MS cover 3mm thick fabricated with Iron frame using 40x40x6 mm size angle iron with hinges and locking arrangements duly painted, excavation, earth work, etc., complete all as specified and as directed.

17

-

-

... More
S&F full circle metal impact sprinkler, corrosion proof I beam construction for added strength, Stainless Steel spindle, fulcrum pin and spring well balanced gun metal swing arm to ensure smooth and uniform rotation, Brass nozzles with hydro dynamically designed inner profile for precise jet and longer radius of throw 360 degree angle view complete set all as specified and as directed.

800

-

-

... More
M&L for earthing of machinery/ equipment Installed at power house/ substation complete using galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 32 x 6mm as earthing lead (upto 7.5meter length) by means of bolts, nuts and washers made out of GI/ steel earth strip protected by GI light grade pipe of 40mm dia and connecting to main panel board/ switch board/ control board all as shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10cm center to center both ways incl earth work like excavation, returning filling back disposal, etc., complete all as specified and as directed. Note : The rate is deemed to be inclusive of the cost of earth work, excavation in any type soil and removal of surplus soil to a distance of 50 mtrs, PCC 1:2:4 type B1 for earth pit, RCC cover with 6 Nos 6 mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI wire of length up to 7.50m, etc,.

8

-

-

... More
Supply, install, test and commissioning of Centrifugal self priming monoblock pump set capable of pumping 28.2 LPS at 18 Mtr head of minimum 10 HP capacity, electrically driven 3 phase, 50Hz, 415Volts energy efficient with IE2 motor efficiency with cast iron impeller & motor body and SS pump shaft, squirrel cage TEFC induction motor 3 phase, 415Volts, AC, 50 Hz, IP:55 protection, Class F insulation, suction & delivery pipe of 100mmx80mm size coupled on common base chanel including necessary PCC foundation works, nuts & bolts, suitable size copper cable from starter to motor through PVC flexible pipe, suitable size of suction pipe not less than 20 feet or as requiredd at site, air release valve, foot valve on suction side, etc., complete all as directed and specified. Make : Kirloskar Model KDI 1030 EE2 or equivalent

2

-

-

... More
Supply, install, test and commissioning of Centrifugal self priming monoblock pump set capable of pumping 18.2 LPS at 18 Mtr head of minimum 7.5 HP capacity electrically driven 3 phase, 50Hz, 415 Volts energy efficient with IE2 motor efficiency with cast iron impeller & motor body and SS pump shaft, squirrel cage TEFC induction motor 3 phase, 415Volts, AC, 50 Hz, IP:55 protection, Class F insulation, suction & delivery pipe of size 65mm x 50mm coupled on common base chanel including necessary PCC foundation works, nuts & bolts, suitable size copper cable from starter to motor through PVC flexible pipe, suitable size of suction pipe not less than 20 feet or as requiredd at site, air release valve, foot valve on suction side, etc., complete all as directed and specified. Make : Kirloskar Model KDI 830 EE2 or equivalent

2

-

-

... More
Supply, install, test and commissioning of Centrifugal self priming monoblock pump set capable of pumping 9.2 LPS at 16 Mtr head of minimum 3 HP capacity electrically driven 3 phase, 50Hz, 415 Volts energy efficient with IE2 motor efficiency with cast iron impeller & motor body and SS pump shaft, squirrel cage TEFC induction motor 3 phase, 415Volts, AC, 50 Hz, IP:55 protection, Class F insulation, suction & delivery pipe of size 65mm x 50mm coupled on common base chanel including necessary PCC foundation works, nuts & bolts, suitable size copper cable from starter to motor through PVC flexible pipe, suitable size of suction pipe not less than 20 feet or as requiredd at site, air release valve, foot valve on suction side, etc., complete all as directed and specified. Make : Kirloskar Model KDI 318 EE2 or equivalent

2

-

-

... More
Supply, install, test and commissioning of Centrifugal self priming monoblock pump set capable of pumping 9.2 LPS at 16 Mtr head of minimum 3 HP capacity electrically driven 3 phase, 50Hz, 415 Volts energy efficient with IE2 motor efficiency with cast iron impeller & motor body and Carbon Steel pump shaft, squirrel cage TEFC induction motor 3 phase, 415Volts, AC, 50 Hz, IP:55 protection, Class F insulation, suction & delivery pipe of size 65mm x 50mm coupled on common base chanel including necessary PCC foundation works, nuts & bolts, suitable size copper cable from starter to motor through PVC flexible pipe, suitable size of suction pipe not less than 20 feet or as requiredd at site, air release valve, foot valve on suction side, etc., complete all as directed and specified. Make : Kirloskar Model KDI 318 EE2 or equivalent

2

-

-

... More
Cutting the existing road of any kind straight by manual, depth and width not less than 30cm for pipes up to 100mm dia for pipes and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed.

100

-

-

... More
EXTERNAL ELECTRIC SUPPLY

-

-

-

... More
M&L for Shifting of the any make of transformer rating 100 KVA mounted on plinth/ pole from existing location to new location including removing and reconnections of HT/LT side, jumper/ cable connection, control cable connection of transformers including testing complete all as directed. Note : The rate quoted shall be deemed to be inclusive of necessary crane/ vehicle charges for shifting and installation of the transformer.

1

-

-

... More
M&L for concrete foundation suitable for 160 KVA Transformer as per OEM recommendation of minimum size 1.80 x 1.50 x 1.50m (above GL) and 2.20x1.90x1.0m (below GL) inlcuding excavation in trenches in hard/dense soil, PCC 1:4:8 type D2 bed concrete, RR stone masonry in CM 1:6 for foundation, plastering in CM 1:4, 20mm thick PCC coping including RFR, removal of surplus soil and three coats of white wash, etc., complete all as specified and directed.

1

-

-

... More
Supply, installation, testing and commissioning of LT feeder pillar box, factory made, CPRI approved, outdoor type floor mounting with channel iron pedestal frame made out of 3mm thick CRCA sheet steel for outer body and 2mm thick for inner partition, compartmental type, dust proof, free standing, suitable for working on 440 Volts, 3 phase, 50 Hz, AC supply, vermin proof, front and rear opening, hinged doors, etc., powder coated as per seven tank process with IP:65 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm , 3 phase and neutral aluminium bus bar suitable capacity with non adhesive color coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts, bolts and washers, copper strips of suitable size for connecting MCCB, Digital Voltmeter, Digital Ammeter with suitable rated CTs, LED phase indication lamps & PCC works complete all as specified and directed with the following switch gears :- Location : STP P/H Panel (Zone-IA) (a) 125 Amps MCCB FP 25 KA - 01 No (Incoming) (b) MCCB FP 100Amps 25 KA - 1 No (STP Panel) (c) MCCB FP 20Amps 16 KA - 3 Nos (P/H-01, SL-01 & Spare). (d) MCCB FP 20Amps 16 KA - 3 Nos (Treated water) (e) Digital Voltmeter 0 to 415 Volts

3

-

-

... More
(g) Digital Amp meter 0 to 200 Amps with CT (h) DOL starter suitable for 5 HP Pump Set (Treated Water)- 02 Nos (j) Street Light timer switch with contactor SPN- 01 No

-

-

-

... More
All as per Item No 90 above but comprising of the following switch gears :- (a) 40 Amps MCCB FP 16 KA - 01 No (Incoming) (b) MCCB FP 25 Amps 16 KA - 01 No (STP Panel) (c) MCCB FP 16 Amps 16 KA - 3 Nos (Treated-02 Nos). (d) Digital Voltmeter 0 to 415 Volts (e) Digital Amp meter 0 to 200 Amps with CT (f) DOL starter suitable for 1 HP Pump Set (Treated Water)- 02 Nos Location : STP P/H Panel (Zone-IB)

1

-

-

... More
All as per Item No 90 above but comprising of the following switch gears :- (a) 200 Amps MCCB FP 36KA - 01 No (Incoming) (b) MCCB FP 160 Amps 25 KA - 2 Nos (STP Panel+ Spare) (c) MCCB FP 63 Amps 16 KA - 1 No (APFC panel) (d) Digital Voltmeter 0 to 415 Volts (e) Digital Amp meter 0 - 200 Amps with CT (f) Street light timer switch with contactor 4P - 01 No Location : Zone-III (Main LT Panel near Transformer)

1

-

-

... More
All as per Item No 90 above but comprising of the following switch gears :- (a) MCCB FP 160 Amps 35 KA - 1 No (Incoming) (b) MCCB FP 100 Amps 25 KA - 1 No (out going for STP) (c) MCCB FP 25 Amps 16 KA - 1 No (d) MCCB FP 20Amps 16 KA - 05 Nos (out going for LW1, LW3, TW Pumps-2, PH-1) Location : Zone-III (STP P/H Panel)

1

-

-

... More
All as per Item No 90 above but comprising of the following switch gears :- (a) MCCB FP 160 Amps 35 KA - 1 No (Incoming) (b) MCCB FP 100 Amps 25 KA - 1 No (out going for STP) (c) MCCB FP 25 Amps 16 KA - 1 No (d) MCCB FP 20Amps 16 KA - 05 Nos (out going for LW1, LW3, TW Pumps-2, PH-1) Location : Zone-III (STP P/H Panel)

1

-

-

... More
All as per Item No 90 above but comprising of the following switch gears :- (a) MCCB FP 315 Amps 35 KA - 1 No (Incoming) (b) MCCB FP 250 Amps 25 KA - 1 No (out going) (c) MCCB FP 100 Amps 25 KA - 1 No (out going) (d) Street light timer switch with contactor & MCB 16A TPN - 01 No Location : Zone - IV & V (Main LT Panel near Transformer)

1

-

-

... More
All as per Item No 90 above but comprising of the following switch gears :- (a) MCCB FP 250 Amps 36 KA - 1 No (Incoming). (b) MCCB FP 160 Amps 36 KA - 1 No (STP) (c) MCCB FP 40 Amps 25 KA - 02 Nos (PH & STP) (d) MCCB FP 32Amps 25 KA - 02 Nos (Treated) (e) MCCB FP 20 Amps 25 KA - 01 No (ILW-1) (f) Star Delta starter suitable for 12.5 HP Pump Set (Treated Water)- 02 Nos Location : Zone - IV & V(STP P/H Panel)

1

-

-

... More
All as per Item No 90 but including Programmable logic controller (PLC) or Remote Terminal unit (RTU) for automatic human intervention free operation of pumps as per automation logic given in Annex "I" of PS mainly comprising Ultrasonic liquid level transmitter, Data transmission arrangement required for integrating with SCADA, any associated instrumentation, cabling rqmt for Panel internal wiring, communication, Networking, etc., comprising of the following switch gears :- (a) MCCB FP 40 Amps 16 KA - 1 No (Incoming). (b) MCCB FP 25 Amps 16 KA - 3 Nos (out going). (c) MCB SPN, 20 Amps, 10 KA - 01 No (d) Starter suitable for 3 HP Submersible Pump- 03 Nos (e) Ultrasonic liquid level transmitter for controlling three Nos of pumps for auto operation based on liquid level of sump/tank with the following specifications: (i) Type : Ultrasonic (Sound wave) (ii) Measuring range : 0.4 - 6 mtr (iii) Power supply : 16-30 V DC (iv) Output : 4-20 mA (v) Accuracy : ±0.5% of FSD (vi) Maximum temperature : -40 to 70C (vii) Maximum pressure : 1 bar (viii) Accessories : Mounting bracket & FRP canopy Location : Lift Well No.2, Zone 1

1

-

-

... More
All as per Item No 90 above but comprising of the following switch gears :- but comprising of the following switch gear s:- (a) MCCB FP 32 Amps 16 KA - 1 No (Incoming). (b) MCCB FP 20 Amps 16 KA - 2 Nos (out going). (c) MCB SPN, 10 Amps, 10 KA - 01 No (d) Starter suitable for 3 HP Submersible Pump-02 Nos (e) Ultrasonic liquid level transmitter for controlling two Nos of pumps for auto operation based on liquid level of sump/tank with the following specifications: (i) Type : Ultrasonic (Sound wave) (ii) Measuring range : 0.4 - 6 mtr (iii) Power supply : 16-30 V DC (iv) Output : 4-20 mA (v) Accuracy : ±0.5% of FSD (vi) Maximum temperature : -40 to 70C (vii) Maximum pressure : 1 bar (viii) Accessories : Mounting bracket & FRP canopy Location : Lift Well No1, Zone 1 & 3 & Lift Well No. 2 of Zone 4/5)

3

-

-

... More
Notes for Item Nos. to : The rate quoted shall be deemed to be included for all out going/ incoming cable connection marking including digging out loop, writing of feeder names with white paint in capital letters, suitable size of glands & lugs to be provided for cable, etc., complete.

-

-

-

... More
S&F hot press moulded SMC junction/ terminal box of size with internal diamensions of 200x140x95mm with hinged door including provision of 2 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/ glands, fixed on pole by means of clamps made out of MS flat iron of size 25mm x 3mm including dismantling of old unserviceable all as specified and as directed. Make : Hensel/Syntex/C&S

24

-

-

... More
Material and labour for Earthing for machinery/ equipment installed at power house/ substation complete with galvanized steel earth plate electrode of size 600mm x 600mm, 6.0mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level, surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt, filling in alternate layer and earth plate connected to galvanized iron earth lead strip of size 32 x 6mm as earthing conductor by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES Schedule (Part I) (2009) connected to earth test point/ main switch/ DB all as specified including testing on completion with and including 40mm bore medium grade GI protection pipe upto 7.5m long for GI earth strip including PCC 1:3:6, type C-1 pit with 40mm thick, precast RCC 1:2:4, type B-1 cover reinforced with 12mm dia MS bars @ 150mm c/c both ways with lifting hooks made out of 12mm dia MS bars, wire mesh funnel with watering pipe 20mm dia medium grade as specified including necessary excavation and earth work in any type of soil, etc., complete all as specified and as directed.

48

-

-

... More
Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 mtrs, PCC 1:2:4 type B1 for earth pit, RCC cover reinforced with 6 Nos 6mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI Wire length up to 7.50m will be measured as one unit)

-

-

-

... More
M & L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried in ground vertically to a depth not less than 2.25 metre below normal ground level, normal with top edge of earth plate not less than 1.5 metre below normal ground level, earth plate connected to a galvanised earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I (2009) connected to earth test point all as specified or indicated including testing on completion with and including 15 mm bore light grade GI protection pipe 7.5 meters long for earth including PCC 1:2:4 pit with pre cast RCC 1:2:4 type B1 cover 40 mm thick reinforced with 6mm dia MS bars @ 100mm c/c both ways with lifting hook made out of 6mm dia MS bar, watering arrangment with funnel, common salt and charcoal filling, necessary excavation and earth work in any type of soil etc., complete all as specified and as directed.

5

-

-

... More
Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 6 mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI wire length up to 7.50m, etc.,

-

-

-

... More
Design, manufacture, supply, install, test and commission Automatic Power Factor control panel 50 KVAR capacitor bank in 4 steps as indicated below with microprocessor best controller units suitable for operation on AC 415 Volts , 50 Hz ,supply, suitable for installation outdoor wheatherproof type, front with hinge type door and locking arrengement bottom with detachable sheets for cable entry/ exit , top with sloping caonopy fabricated with 3mm thick MS sheets suitable size to install following switchgears/ items,powder coated both inside and outside, complete npanel board install on suitable PCC pillar with bolts and nuts grouted to pilars and comprising following switchgear/ capacitors control gear, etc., all as specified and as directed. Location : Zone IV & V

1

-

-

... More
(a) Incomer MCCB TPN 100 Amps 25 KA - 01 No (b) Current Transformer 100/5 Amps - 03 Nos (c) Alluminium bus bar insulated TPN 200 Amps - 01 set (d) Capacitor 25 KVAR super heavy duty long life for industrial load - 01 No (e) Capacitor 15 KVAR super heavy duty long life for industrial load - 01 No (f) Capacitor 5 KVAR super heavy duty long life for industrial load - 02 Nos including suitable capacities contactors, MCBs, Fuses, Relays, Digital type indicating meterss for voltage, current, PF, etc., complete internally prewired with copper conductor.

-

-

-

... More
All as per Item No. above, but comprising the following : (a) Incomer MCCB TPN 63 Amps 16 KA - 01 No (b) Current Transformer 100/5 Amps - 03 Nos (c) Alluminium bus bar insulated TPN 200 Amps - 01 set (d) Capacitor 15 KVAR super heavy duty long life for industrial load - 01 No (e) Capacitor 5 KVAR super heavy duty long life for industrial load - 03 Nos including suitable capacities contactors, MCBs, Fuses, Relays, Digital type indicating meterss for voltage, current, PF, etc., complete internally prewired with copper conductor.

1

-

-

... More
All as per Item No. above, but comprising the following : (a) Incomer MCCB TPN 63 Amps 16 KA - 01 No (b) Current Transformer 100/5 Amps - 03 Nos (c) Alluminium bus bar insulated TPN 200 Amps - 01 set (d) Capacitor 15 KVAR super heavy duty long life for industrial load - 01 No (e) Capacitor 5 KVAR super heavy duty long life for industrial load - 03 Nos including suitable capacities contactors, MCBs, Fuses, Relays, Digital type indicating meterss for voltage, current, PF, etc., complete internally prewired with copper conductor.

1

-

-

... More
M&L for spreading riddled earth (obtained and prepared from excavated earth) for sand cushioning of cable laid in trenches/ duct complete all as specified and directed by Engineer-in-Charge. Note : Punned thickness 18cm (6.25cm below cable and 11.75 cm above cable) shall be measured for payment purpose. The unit rate quoted shall deemed to be inclusive of all arrangement as mentioned.

375

-

-

... More
Cutting the existing road/ PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable , HDPE pipe medium duty of size 100 mm dia and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20mm graded aggregate stone complete all as specified and directed.

24

-

-

... More
SCHEDULE 'A' PART XVIII- MANNING AND OPERATION OF STP - PHASE III (10 YEARS INCLUDING DEFECTS LIABILITY PERIOD OF 2 YEARS)

-

-

-

... More
Comprehensive Operation & Maintenance of Sewage Treatment Plants along with automation & SCADA system, of capacities 850 KLD, 500 KLD, 250 KLD & 26 KLD at different locations of AOC Centre Secunderabad installed under Srl item No. ___ of BOQ/ (Schedule 'A' Section-___) during first year of defect liability period of 02 years for the duration of 24 hours round the clock, starting from next day of certified date of physical completion complete inclusive of all consumables, daily, weekly, monthly, quarterly, Half yearly & Yearly maintenance of equipment and complete all as per scope of work along with terms & conditions given in para A14.0 to para A14.5 of Annexure-I. Note : (i) Sewage water for the STPs & electricity required for operation of STPs shall be provided free of cost. (ii) Treated Sewage water will be utilized by MES and user units as per their requirement and surplus water will be drained to nearby nallah. Required pumps and valves for the purpose at STPs are also to be operated & maintained by the contractor. (iii) De-watered sludge will be the property of the contractor for further disposal to any location outside defense land under his own arrangement.

12

-

-

... More
(iv) Cost of Manpower required on daily or occasional basis for Comprehensive Operation & Maintenance, is deemed to be included in quoted rates. (v) Diesel for day to day operation of DG sets installed at these STPs will be issued by MES. (vi) Any penalty imposed by civil agencies on MES/user unit, on account of not meeting the parameters of treated sewage water shall be paid by the contractor only. (vii) cost of all the consumables such as all the dosing chemicals of STPs, repair/maintenance/replacement of all equpments/components/civil works is to be borne by the contractor only. (viii) Lab test of STP treated water twice in a year from NABL accredited Lab is to be done by the contractor at his own cost and report is to be submitted to the GE. (ix) Calibration of all the measureing instruments is to be carried by the contractor at his own cost annually from NABL accredited Lab and report is to be submitted to the GE. (x) Various diginitories are likely to visit the STPs quite frequently, as and when such event is intimated to the contractor by the GE, The installations shall be made ready for inspection as per instructions of GE/Engineer-in-charge.

-

-

-

... More
(xi) Training of MES staff as detailed by the for a duration of one week per annum shall be arranged by the contractor for understanding of operation & maintenance of STP plants, automation & SCADA system. (xii) Power supply upto cable termination of Main LT Panel at a particular STP will be maintained by MES. Building electrification, external & internal lighting at STPs will also be maitained by MES. (xiii) Contractor shall provide two sets of uniform with name plate and one mobile set duly recharged of each operator & helper. (xiv) Testing of earthing of each equipment and record to be produced to Engineer-in-Charge in every six months, tesing equipment will be provide by the Contractor. The earth result to be maintained below 01 Ohms. (xv) Before quoting, it is advised to go through Annexure-I in detail because detailed scope of work, desired specifications, various terms and conditions etc are given therein and the same is deemed to be included in quoted rates.

-

-

-

... More
All as per Item No.107 above but for second year of defect liability period

12

-

-

... More
All as per Item No.107 above but for First year after defect liability period

12

-

-

... More
All as per Item No.107 above but for 2nd year after defect liability period

12

-

-

... More
All as per Item No.107 above but for 3rd year after defect liability period

12

-

-

... More
All as per Item No.107 above but for 4th year after defect liability period

12

-

-

... More
All as per Item No.107 above but for 5th year after defect liability period

12

-

-

... More
All as per Item No.107 above but for 6th year after defect liability period

12

-

-

... More
All as per Item No.107 above but for 7th year after defect liability period

12

-

-

... More
All as per Item No.107 above but for 8th year after defect liability period

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.