Military Engineer Services Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 May 2024
Closing Date6 Jun 2024
Tender Amount₹ 48,00,000
Costs
EMD
₹ 96,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_654255_1Bid Award Id
ViewTender No
8944Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://MilitaryEngineerServices
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per SI item No. 2 here-in-before but for one Exhaust fan point controlled by one 5 Amps one-way modular
20
-
-
... More
All as per SI Item No.2 here-in-before but for one 3 pin socket out let 6 amps modular socket controlled by one way switch on same board.
125
-
-
... More
All as per SI Item No.2 here-in-before but for one 3 pin socket out let 6 amps modular socket controlled by one way switch on independent board.
120
-
-
... More
All as per SI item No. 2 here-in-before but for one Bell point controlled by one 5 Amps one-way modular
45
-
-
... More
All as per SI item No. 2 here-in-before but for One light point controlled by two 2-way switches
75
-
-
... More
All as per SI Item No.2 here-in-before but for 15 amps socket outle with 2.5 Sq.mm copper cable including 2.5 Sq.mm PVC insulated copper condutor cable as earth continuity conductor and connecting to earth dolly, complete all as specified and as directed.
155
-
-
... More
All as per item No 2 above but with cable 4 sqmm for phase and neutral & 4.0 sqmm for earth continuity all as directed ( for 20 Amps socket ) .
5
-
-
... More
M&L for light point wiring complete with 1.5 Sq.mmm PVC insulation unsheathed muilt-starnded FRLSH copper conductor 1100 Volts grade draw through in and concealed type in existing PVC conduit in walls/roof including making necessary chases in walls and making good to match with exterior emultion paint for existing surface and including provision of modular metal GI flush boxes with modular metal frame plate and white cover for housing switch, sockets, regulators etc, including 1.5 sqmm PVC insulated unsheathed multi-stranded FRLSH copper conducotr cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one 5 amps one way modular switch for one light/bell point, complete all as specified and directed.
NOTE;- The cost of meTal flush boxes, modular white cover plate deemed to include under respEctive items of this Schedule.
165
-
-
... More
All as per SI item No. 11 here-in-before but for one fan point controlled by one 5 Amps one-way modular
15
-
-
... More
All as per SI item No. 11 here-in-before but for one Exhaust fan point controlled by one 5 Amps one-way modular
90
-
-
... More
All as per SI Item No.11 here-in-before but for one 3 pin socket out let 6 amps modular socket controlled by one way switch on same board.
35
-
-
... More
All as per SI Item No.11 here-in-before but for one 3 pin socket out let 6 amps modular socket controlled by one way switch on independent board.
115
-
-
... More
All as per SI Item No.11 here-in-before but for 15 amps socket outle with 2.5 Sq.mm copper cable including 2.5 Sq.mm PVC insulated copper condutor cable as earth continuity conductor and connecting to earth dolly, complete all as specified and as directed.
125
-
-
... More
All as per item No 11 above but with cable 4 sqmm for phase and neutral & 4.0 sqmm for earth continuity all as directed ( For 20 Amps socket ) .
80
-
-
... More
S&F Modular switch one way 6 Amp, one module 240V, single pole complete all as specified and as directed.
1340
-
-
... More
S&F Modular switch one way 16 Amp, one module 240V, single pole complete all as specified and as directed.
280
-
-
... More
S&F Modular Socket, 6A - 2/3 pin combination 2 module, complete all as specified and as directed.
395
-
-
... More
S&F Modular Socket, 6A/16A - 2/3 pin(5pin) combination 2 module, complete all as specified and as directed.
280
-
-
... More
S&F in repair Modular switch two way 6 Amp, one module 240V, single pole complete all as specified and as directed.
75
-
-
... More
S&F in repairs Bell push modular type, 5 Amps button all as specified and as directed.
45
-
-
... More
S&F in repairs ceiling rose two to three terminal surface backelite type AC 50 HZ 230 Volt, Complete al as specified and as directed.
945
-
-
... More
S&F in repairs Modular fan step regulator, 120W - 2 Module, complete all as specified and as directed.
190
-
-
... More
S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with on single pole MCB SP 20Amps with 'C' curve, 240 volts complete as as specified and directed.
85
-
-
... More
S&F in replacement, basic all purpose surface or wall mounted 20W LED batten with polycarbonate housing and integratedelectronic driver complete all as specified.
Make: Havells Cat No LUMILINEBS20WLED865SPCWH or techno commercially equivalent of Phillips / Wipro
460
-
-
... More
S&F in replacement, basic all purpose surface or wall mounted 9W LED batten with polycarbonate housing and integratedelectronic driver complete all as specified.
Make: Havells Cat No LUMILINEBS9WLED865SPCWH or techno commercially equivalent of Phillips / Wipro
200
-
-
... More
S&F in replacement, universal batten for fixing T5/T8 LED tube rods with polycarbobnate housing complete all as specified.
Make: Havells Cat No REGALBATTENT8UPTO1X22 WSSBSWH or techno commercially equivalent of Phillips / Wipro
200
-
-
... More
S&F in replacement, ultra bright LED polycarbonate tubelight with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders complete all as specified.
Make: Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC or techno commercially equivalent of Phillips / Wipro
500
-
-
... More
S&F in replacement, LED Security light/Bldg light of 45W powder coated light fitting suitable for suspension mounting at any height in bldg with aluminum alloy pressure die cast housing and control gear box with high efficiency long life LEDs with lumen output not less 4500lm, CCT 5700 K or above with specified beam angle to ensure better uniformity of light distribution, IP65 Protection and impact resistance of IK07, built in electronic driver, lower THD, open circuit protection, over surge and voltage protection complete with all accessories complete all as specified. Make: Havells CAT No. ENDURASUNDOWNSL45WLED765PASYBOPC or Philips CAT No BY 515P LED 1505 5700 NB PSU GR or Techno commercially equivalent in crompton.
20
-
-
... More
S&F in replacement , 10W decorative hexagon bulkhead light fitting suitable for vertical surface mounting with IP 66 ingrss protection complete all as specified and as directed .
20
-
-
... More
Supply and fixing in replacement Single pole and neutral Sheet metal enclosure 8 way double door for MCB’s, Phosphatised Powder Painted with Bus Bar 200 amp rated, 240 volt AC complete all as directed.
85
-
-
... More
S&F in replacement MCB Single pole and neutral 40 Amps capacity 10 KA 240 Volts 50 HZ complete all as specified and directed .
85
-
-
... More
S&F in replacement MCB single pole (SP) 10 kA of 6 Amps to 32 Amps capacity 240 Volts 50 HZ complete all as specified and directed .
510
-
-
... More
M&L for sub main wiring complete with 2 runs of 6 sq.mm PVC insulated and unsheathead 1100V grade FRLSH multistranded copper conductor and drawn through in and including PVC conduit of medium grade and condiut accessaries of suitable size concealed in walls with, necessary civil works for making good distrubed surface, and/or laid on surfaces over ceilings/columns etc and connecting terminal ends to meters and DB's including of 1 run of 6 Sq.mm insulated multistanded FRLSH copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old one complete all as specified and directed.
Note;- (i) Two runs of 6 Sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of suitable size of PVC rigid conduit and required conduit accessaries shall be measured as one unit length.
(ii) Extra lenght of cable / wire required for connection to MCBs shall not be measured and the measured and the rate quoted per unit shall deemed to be inclusive of the same acordingly.
1400
-
-
... More
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 5 of MES SSR Part-I, including taking down old one and as directed.
12
-
-
... More
M&L for taking down KWH and keep in safe custody and refixing the same as including necessary electric connection from main to KWH meter and KWH meter to out going distribution board complete all as specified and directed .
60
-
-
... More
Dismantling and taking down Geyser of 25/50 liters capacity of any make and pattern from the existing position and removing bolts and nuts, opening and taking out all internal unserviceble parts, leak testing of the inner container, refixing the same in original position after necessary repair complete all as directed by Engineer-in-charge.
Note:- Replacement of unserviceble parts will be measured and paid separately under relevent item of this schedule 'A'.
20
-
-
... More
S&F Heating element of any size of capacity 1000 watt to 2000 watt of any type round or triangular. Complete all as directed by Engrs-In -charge
15
-
-
... More
S&F thermostate suitable for 25 to 50 ltr capacity of geyser with adjustable temprature setting .Complete all as directed by Engrs-In -charge
15
-
-
... More
S&F Gasket for heating element of geyser of suitable size . Complete all as directed by Engrs-In -charge
15
-
-
... More
S&F Indicator lamp for geyser of suitable size. Complete all as directed by Engrs-In -charge
15
-
-
... More
M&L for dismantling old unserviceable Geyser and removing from site and depositing to MES store & Fixing only New Geyser by shifting the position of Nut,bolts by grouting at required position including testing on completion.( Note: Geyser Shall be issued under schedule "B" held under Maintenance)
2
-
-
... More
S&F CP connection pipe for inlet/outlet connection of Geyser with heat resistance washer & nuts bolts Make: Essco/Agnee/Sons/Parko. Complete all as directed by Engrs-In -charge
30
-
-
... More
Taking down the existing unserviceable ceiling of any make/ model and sweep for overhauling / servicing after disconnecting carefully cleaning and checking for unserviceable components, and replacing the defective components such as bearing, rubber bush/bolt, gunmetal bush, capacitor flexible chord and shaft / painting etc., including assembling after lubricating the movable components and installing in its original position connecting, testing and commissioning all as specified and directed by the Engineer-in-charge.
300
-
-
... More
All as per item No.45 above but single phase Exhaust fans and Air Circulator from any height installed in residential/workshops.
Note:- Bearing/ Gunmetal bush/ rubber bush bolt/ capacitor/ Rewinding / cord flexiable / shaft shall be measured and paid separately under relavent items of Sch ‘A’.
150
-
-
... More
Supply & fixing rubber bush/bolt /clamps and connected items suitable for ceiling fan of any make/model/ type sweep of 1200/1400 mm all as specified and directed
100
-
-
... More
Supplyand fixing shaft suitable for ceiling fan / Exhaust fan/ pedestal fan/ wall mounted fan/ Air circulator of any make/model and sweep with necessary machining work all as specified and directed by the Engineer-in-charge.
100
-
-
... More
Supply and fixing cord flexible copper conductor, twin core 0.50 Sqmm 1.5m long PVC insulated unsheathed 415 volts grade for ceiling fans all as specified and directed by the Engineer-in-charge. Make : Finolex/Fine Cab
100
-
-
... More
M & L for rewinding of any make/model of fans including removal of existing burnt windings carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enmelled copper conductor of same gauge/same number of turns as that of existing and connecting the coils suitable to operate on 230 volts single-phase AC supply permanent capacitor type, tying the windings nd applying air dry insulating arnish and drying the windings thoroughly all as specified and directed for :-
-
-
-
... More
Ceiling fan of 1200 / 1400 mm sweep.
200
-
-
... More
Exhaust fan of 230/300mm sweep
100
-
-
... More
Exhaust fan of 450 mm sweep / Air circulator of 450/600 mm sweep.
20
-
-
... More
Supply only ball bearing suitable for ceiling fan / wall mounting fan/Pedestal fans of any Sweep any make / model all as specified and directed by the Engineer-in-charge. Make : SKF/NBC/TATA/Usha
200
-
-
... More
All as per Item No.51 above but for Exhaust fan / air cirulator of any make / model / sweep.
100
-
-
... More
Supply only gunmetal bush suitable for ceiling fan / wall mounting fan/Pedestal fans of any make/model/ sweep and Exhaust fan of any sweep with necessary machining work as per requirement all as specified and directed by the Engineer-in charge.
100
-
-
... More
S&F fan down rod 1.5/2.0/2.5 complete all as specified and directed.
37
-
-
... More
Supply only capacitor 2.5 mfd suitable for ceiling fan and testing complete all as directed by Engineer-in-charge Make- Tibcon/Capco.
150
-
-
... More
Supply only capacitor 3.5/4 mfd suitable for ceiling fan and testing complete all as directed by Engineer-in-charge Make- Havells/Tibcon/Capco.
100
-
-