Military Engineer Services Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
₹ 1,00,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_673582_1Bid Award Id
ViewTender No
GE(S)/SEC/TOKEN-48 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of Capacity 1000 litres including PTMT ball valvehigh pressure of 20mm complete all as specified and directed.
25
-
-
... More
S&F in repairs Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 20 mm bore and complete all as specified and directed.
20
-
-
... More
S&F in repairs Ball valve, high pressure with PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or fixed of size 20 mm bore complete all as specified and directed. (Min Wt 20mm- 210 gms)
50
-
-
... More
Demolition and breaking up drain AC pipes/PVC pipe set in cement mortar of any size complete all as specified and as directed.
100
-
-
... More
S&F PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed to walls bore of the pipe 110mm complete all as specified and as directed.
50
-
-
... More
S&F PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed to walls bore of the pipe 75mm complete all as specified and as directed.
50
-
-
... More
S&F PVC (SWR) bends 110mm complete all as specified and as directed.
10
-
-
... More
S&F PVC (SWR) bends 75mm complete all as specified and as directed.
10
-
-
... More
Demolition of cement concrete of any description and in any position not otherewise specifically provided for as in roof etc complete all as specified and as directed.
65
-
-
... More
Taking down existing water proofing treatment with tarfelt including cement plaster from roof including parapets etc, and removing the debris to a distance not exceeding 250m complete all as specified and directed.
2000
-
-
... More
M&L for 40mm thick plain cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in padding (level course) on roof incl finishing the cement concrete surfaces even & smooth without using extra cement complete all as specified and as directed.
1200
-
-
... More
M&L for rendering 10 mm thick in CM (1:3) using water proofing compound @ 2% of the weight of cement or as per manufacturer instruction as in roof and chajjas finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed. Note :( Water proofing compound will be measured and paid separately Under relevant item).
2000
-
-
... More
M &L for priming plastered roof surfaces (Non approachable roof ) with bituminous primer @ 0.3 Kg/Sqm as per IS 3384 and providing water proofing treatment by applying 3.5 Kg/Sqm ATACTIC polypropylene (Advanced APP torch on membrane mineral finish) having polyester film reinforcement stabilized with fibre glass and finished on top with grey mineral slabs torch on system of thickness 3 mm by torch bonding complete all as specified and as directed.
2000
-
-
... More
M&L for water proofing treatment with APP based standard membrane over PCC padding in approachable roof with the following courses of treatment : (a) Apply bituminous primer (IS3384) @ 0.30 Kg/Sqm of the surface area including cleaning the surface complete all as specified . (b) Apply APP plastomeric bitumen based water proofing membrane polyster reinforced (3.50 Kg/Sqm) with 10 cm overlaps and torch bonded at joints including surface preparation before and after application of treatment as per manufacturers instruction complete all as specified and directed.
100
-
-
... More
M&L for providing 40 mm thick PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) in approachable roof mixed with polyster fibre as per manufacturer instruction and finish the top surface of concrete even and smooth without using extra cement complete all as specified and as directed. (Note : Polyster fibre shall be measured and paid seperately under appropriate item).
100
-
-
... More
Supply only Polyster Fibre . Make (RECRON 3S or equivalent) complete all as specified and as directed.
5
-
-
... More
M&L for forming construction (Dummy) joints 10 mm deep and 6 mm wide, filled with sealing compound Grade 'A' complete all as specified and as directed.
30
-
-
... More
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
30
-
-
... More
M&L for uprooting of wild trees such as grass/bushes etc any girth from the roof / wall surfaces / AC sheets/soil pipes surrounding including its penetrated roots with suitable cleaning chemical and making good to the damaged plaster by providing CM 1:3 and finish the surfaces to match with the existing surface complete all as specified and as directed.
30
-
-
... More
M&L for crack filling with approved crack filler to arrest seepage and running water through masonry/RCC surfaces etc. complete all as specified and as directed. Make : Dr.Fixit Leak Plug or its equivalent.
50
-
-
... More
M&L for preparation of plastered surfaces and applying two coats of water proof coating (Dr. Fixit Rain Coat exterior waterproof coating) over a coat of primer (Dr. Fixit Prime seal diluted with potable water by volume in 2:1 ratio, 2 parts primer and 01 part water) including filling of cracks upto 5 mm width, with Dr. Fixit Crack-X, or Dr. Fixit unifiller on external surfaces of wall to arrest the seepage / dampness and running water in the masonry surfaces complete all as specified and as directed. Make : Dr. Fixit or its equivalent.
1200
-
-
... More
M&L for Heavy duty Vitrified tiles of size 300x300x8 to10mm thick or high dimension (except thickness) of any colour any design durastone weather proof impacr resistant abrasion resistant exterior tiles as in floors etc set and jointed in neat cement slurry over and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
100
-
-
... More
All as per item No 25 above but in skirting/dado laid over 10mm thick cement plaster in cement mortar 1:4 complete all as specified
10
-
-
... More
Dismantling of Asbestos cement (corrugated, semicorrugated and Transulent sheet etc) sheets in roof covering incl ridges complete all as specified and directed.
1215
-
-
... More
Dissmantling timber scantling 40 sq cm and over in any position complete all as specified and directed.
3
-
-
... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
33.84
-
-
... More
M&L Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
1065
-
-
... More
S&F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strengh of 550 mpa as on roof covering/ridges fixed with self tapping screws complete all as specified and directed.
150
-
-
... More
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Grade Fe 410 -W (Gde E- 250) quality A
4200
-
-
... More
S & F MS Steel work in tubular trusses and tubular posts/ purlins including special shaped washers etc., complete using ERW or induction butt welded tubes conforming to IS :1161-1979 grade st-240 including notching, drilling, fitting, riveting and/or welding or connecting with bed plate, bolt and nuts complete all as specified and as directed
1200
-
-
... More
S & F plates (Plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes with attachment etc and fixed by riveting or welding or with nut and bolts (including nut and bolts) conforming to Fe- 410-W Grade E- 250, quality B, complete all as specified and as directed.
240
-
-
... More
M&L for preparation new steel surfaces of any description exc 10cm width or girth when unconnected with other painting or when painted in a different tint, and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
70
-
-
... More
Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets.
400
-
-
... More
M&L for providing false ceiling with anodised aluminium snap grid frame work with size of grid 605 x 605 mm with aluminium main tee size 25 x25 x1.60mm thick and, cross T section of size 25 x 25 x 1.60mm thick and wall angle of size 25x25x2mm thick fixed to roof with rawl plugs/GI wire suspenders complete all as specified and directed.
400
-
-
... More
M&L for 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework in ceiling with screws and preparing surface and applying two coats of OBD over a coat of primer complete all as specified and as directed.
400
-
-
... More
S&F in repairs of CPVC pipes20 mm dya SDR 11 & plian CPVC SDR 11 fittings in wall /ceiling or laying in floors taking down old GI tubes complete all as specified and directed.
206
-
-
... More
S&F in repairs of CPVC pipes25 mm dya SDR 11 & plian CPVC SDR 11 fittings in wall /ceiling or laying in floors taking down old GI tubes complete all as specified and directed.
50
-
-
... More
M&L for plain cement concrete type B1, (20 mm graded aggregate) as in coping, tank stagging and similar works etc complete all as specified and directed.
3
-
-
... More
Disconnecting existing tanks setting aside (or lowering if required) for repairs, cleaning with detergent/detergent powder etc. reconnecting and re-fixing in position including cleaning and removing all scale dirt etc. from tanks and from mouth of circulating pipes etc. and writing the date of cleaning of tank and due date for cleaning of tank , capacity of tanks exc. 500 liters and not exc. 1000 liters complete all as specified and as directed(Note: Each tank will be shifted as twice)
10
-
-
... More
Disconnecting existing tanks setting aside (or lowering if required) for repairs, cleaning with detergent/detergent powder etc. reconnecting and re-fixing in position including cleaning and removing all scale dirt etc. from tanks and from mouth of circulating pipes etc. and writing the date of cleaning of tank and due date for cleaning of tank , capacity of tanks exc.250 liters and not exc. 500 liters complete all as specified and as directed(Note: Each tank will be shifted as twice)
10
-
-
... More
S&F in repair CPVC gate valve 25mm dia all as spd and directed.
20
-
-
... More
Demolition of PCC Block walling built in CM 1:6 complete all as specified and as directed
3
-
-
... More
M&L precast cement concrete block masonry with PCC solid blocks in 1:3:6 type C1 using 20mm graded stone aggregates, exc. 10cm in width and set in CM 1:4 complete all as specified and directed.
3
-
-
... More
Taking down cement plaster from walls built in cement mortar, etc. including raking out joints, hacking for key, scrubbing down with water, etc. to receive plaster. complete all as specified.
325
-
-
... More
M&L for rendering 15 mm thick on fair face surfaces of brick work or concrete in CM (1:4) finished even and smooth without using extra cement.complete all as specified and as directed .
175
-
-
... More
M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in CM (1:6) even and smooth without using extra cement complete all as specified.
180
-
-
... More
M & L for preparing new plastered or unplastered surfaces on walls including cornices and applying two coat of cement base paint complete all as specified and as directed .
175
-
-
... More
M & L for preparing new plastered or unplastered surfaces on walls including cornices and applying two coats of Oil bound distemper over a coat of primer complete all as specified and as directed .
150
-
-
Evaluation Notes How It Works ?