Military Engineer Services Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date1 Oct 2022
Closing Date22 Oct 2022
Tender Amount₹ 20,00,000
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_MES_548054_2Bid Award Id
ViewTender No
8277/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIRS /MAINTENANCE OF LAUNDRY PLANT/ELECTRICAL CHIMNEYS AND CERTAIN MISC E/M WORKS AT AFA HYDERABAD
REPAIRS /MAINTENANCE OF LAUNDRY PLANT/ELECTRICAL CHIMNEYS AND CERTAIN MISC E/M WORKS AT AFA HYDERABAD
REPAIRS /MAINTENANCE OF LAUNDRY PLANT/ELECTRICAL CHIMNEYS AND CERTAIN MISC E/M WORKS AT AFA HYDERABAD
BOQ Items
... More
(b) 8-zone microprocessor based automatic fire alarm system with UL/LPCB/CE approved.
5
-
10
... More
© Response indicators
20
-
10
... More
(d) 1.5 sqmmX 2 core FRLS copper conductor shielded cable
150
-
10
... More
(e) Detectors complying with and type certified to EN-45 Addressable type smoke detector Photoelectric/ Optical with base with self built intelligence as per IS:11360
8
-
10
... More
(f) Same as per Item above but Addressable type heat detector with base with rate of rise cum fixed temperature as per IS:2175
8
-
10
... More
(g) Addressable manual call point resettable type
6
-
10
... More
(h) Hooter/Sounder
4
-
10
... More
(j) Single loop main control panel
2
-
10
... More
(k) Two loop main control panel
1
-
10
... More
(l) Speech auto dailing system
2
-
10
... More
(m) 4zone main control panel based automatic fire alarm system with UL/LPCB/CE approved.
2
-
10
... More
(n) Reprogramming 1loop control panel
2
-
10
... More
(o) Reprogramming 2loop control panel
2
-
10
... More
(p) Transformer 24-0-24 volts, 5 amps in existing
2
-
10
... More
(q) Isolator modules
2
-
10
... More
(r) Assorted fuses
10
-
10
... More
(s) Smoke/Fire Detectors
6
-
10
... More
(t) Programming PCB Service Card
2
-
10
... More
(u) MCP
6
-
10
... More
Repairs/ Servicing of hanger doors with necessary greasing and opening the motorised door mechanism of hanger door leaf, servicing /repairing the forward gear, backward gear, gear shaft, pinion, and replacing the worn out/unserviceable spares parts including checking/ maintenance of hanger door electrical panel board and reinstallation the same after repairs including replacement of necessary electrical connections from electrical panel board and checking the alignment bottom and rail for smooth movement of doors any unserviceable spares/ misc items with new one for the entire hanger door satisfactory working. The following major spares will be measured and paid separetly.
Note :- All consumables like grease, cotton waste, nuts, bolts, washers, lugs etc are deemed to be included in the rate quoted
12
-
10
... More
Supply only the following items for replacing only unserviceable item No.3 above:-
-
-
-
... More
Limit switches for automatic cutoff for all driving leaves.
4
-
10
... More
Auxillary Contactors
4
-
10
... More
Power Contactors
4
-
10
... More
Over Load relay
4
-
10
... More
Single phase preventer
4
-
10
... More
Under voltage protection relay
4
-
10
... More
LED Indicator lamps of colors R / Y / B (Make: C&S/SIEMENS/L&T)
4
-
10
... More
Hooters / blinkers
4
-
10
... More
Push button switches
4
-
10
... More
Interlock contactors
4
-
10
... More
Warnings lights
4
-
10
... More
Gear Shaft
2
-
10
... More
Gear Wheel
2
-
10
... More
Bearing suitable for existing shaft
4
-
10
... More
Gear Oil
4
-
10
... More
Taking down old unserviceable PVC Cable and Supply & fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 Sq. mm 4 Core nominal cross section in service connectionsalong with replacement of corroded cable tray/bunching arrangement with suitable cable carriers, festoons etc as per existing capacity at site complete all as specified and as directed.
80
-
10
... More
M & L for taking out motor from the base and re-winding of burnt 2 HP Cap 415 V, 3 phase motors of following capacities with new super enameled copper wire of same gauge and same number of turns as existing after thorough cleaning of stator body and rotor, applying insulating varnish, drying up by heating for improving insulation resistance, re-assembling the motor by replacing both end bearings, re-installing at it’s original position, connecting up, testing and commissioning all as specified and directed Make Kirloskar (For Hanger Doors)
6
-
10
... More
M& L for Servicing of Washer Extractor 60 Kgs capacity of Make RAMSONS. Model RVWE-60 of high spin suspended , made out of fully stainless body, inner basket and outer drum of stainless steel 304 grade, microprocessor controlled with moisture resistance screen, auto reverse automatic with pneumatic valves, front loading open pocket fully stainless steel die pressed door with inner cylinder and outer drum of stainless steel 304 grade complete with built in control panel & motor and replacement of unserviceable spares/ misc items with new one for following specifications :-
4
-
10
... More
a) Microprocessor controlled
-
-
-
... More
b) 24 Programmed storage capacity of 8 cycles each
-
-
-
... More
c) Basket volume: 630 ltr
-
-
-
... More
d) Diameter : 1100 mm f) Motor capacity : 15 HP
g) Water inlet : 40 mm 2 Nos
h) Drain out let: 100mm
j) Air pressure : 5 bar
k) Electric heating capacity : 36 KW
l) Ground force : 345
m) Door opening : 675 mm
o) RPM : 720
p) Overall dimensions : 2020Lx1650W x 2085H in mm
q) Machine weight : 2500 kg
-
-
-
... More
e) Depth : 665 mm
-
-
-
... More
f) Motor capacity : 15 HP
-
-
-
... More
g) Water inlet : 40 mm 2 Nos
-
-
-
... More
h) Drain out let: 100mm
-
-
-
... More
j) Air pressure : 5 bar
-
-
-
... More
k) Electric heating capacity : 36 KW
-
-
-
... More
l) Ground force : 345
-
-
-
... More
m) Door opening : 675 mm
-
-
-
... More
o) RPM : 720
-
-
-
... More
p) Overall dimensions : 2020Lx1650W x 2085H in mm
-
-
-
... More
q) Machine weight : 2500 kg
-
-
-
... More
Note: (i) The rated quoted by the contractor is deemed to beincluding all the Misc Items. Required major Spares required for completion of job satisfactorily measured and paid separately under respective items of the schedule
(ii) All repairs/servicing /maintenance shall have to be carried out by the authorised service personnel
-
-
-
... More
M& L for Servicing of Jumbo Boiler 5.5 ltr capacity of Make RAMSONS. Model RV 4425-80 with vacuum ironing table, 02 Nos of cloth trolley and steam pressing iron including connecting up and replacement of unserviceable spares/ misc items with new one for following specifications :-
4
-
10
... More
a) Vacuum ironing table shall be with silicon form and heat proof cloth, powder coated, with trays, side ironing stand, with silicone iron pad, suction motors full length foot pedal switch to control the suction.
-
-
-
... More
b) The vacuum board shall be uniformly perforated and covered with a stainless steel mesh for perfect and uniform steam ironing control.
-
-
-
... More
c) Suction motor shall be of 0.75 KW (or as required) and other power consumption of the table shall be 1.0 kW (or as required).
-
-
-
... More
d) Electric Steam Iron shall be of 2000 watts confirming to Model No. 2128 of RAMSONS brand with metalized Teflon shoes and with detachable heaters and silicon hose pipe.
-
-
-
... More
e) The jumbo boiler shall be of 5.5 ltr capacity 3KW with steam capacity up to 3 kgs /hour with an operating pressure 3 bar having dimensions not more than 300x570x530 mm with a total weight of 20 kg.
-
-
-
... More
f) Cloth trolley shall be of suitable capacity for shifting the cloths from 60 kg washer extractor as per OEM designs and specifications brand RAMSON or equivalent approved brand.
-
-
-
... More
Note: (i) The rate quoted by the contractor is deemed to be including all the Misc Items. Required major Spares required for completion of job satisfactorily measured and paid separately under respective items of the schedule
(ii) All repairs/servicing /maintenance shall have to be carried out by the authorised service personnel
-
-
-
... More
Supply only of the following spares for repairing /servicing the Mechanical Laundry vide item no 7 to 9:- (a) Teflon Shoe
2
-
10
... More
Hose pipe for Steam
2
-
10
... More
2128 Iron Box
2
-
10
... More
Table Foam of existing size
2
-
10
... More
Table Cloth of existing size
2
-
10
... More
Foot Switch
2
-
10
... More
16 Amps rocker switch
2
-
10
... More
16 Amps contactor
2
-
10
... More
Impeller
2
-
10
... More
1 Hp motor
2
-
10
... More
2 kw heater.
2
-
10
... More
Water level control
2
-
10
... More
6 Amps rocker switch
2
-
10
... More
Pressure switch
2
-
10
... More
Pressure guage
2
-
10
... More
Drier heater
2
-
10
... More
Ucp bearing 210
2
-
10
... More
2 Hp blower motor
2
-
10
... More
2 Hp main motor
2
-
10
... More
PLC ST 200
2
-
10
... More
Drain Valve
2
-
10
... More
Water inlet valve
2
-
10
... More
IO Card
2
-
10
... More
STK 2000 PLC
2
-
10
... More
Belt got washing
2
-
10
... More
Belt for Drier
2
-
10
... More
Fuji drive for washing
2
-
10
... More
Transformer 230v to 12 v
2
-
10
... More
Water level sensor for washing
2
-
10
... More
Shock absorber for washing
2
-
10
... More
Air filter
2
-
10
... More
1/2" Gauge glass with bush
2
-
10
... More
Water level prob
2
-
10
... More
M& L for Servicing of electrically operated screw Air compressor of Make ELGI Global Series Model E15-7.5 suitable for operating pneumatic tools for delivering air pressure of 100 PSI with a discharge capacity not less than 90 CFM with mulitstage oil and moisture separators driers comprised with VFD (Variable frequency Drive) direct drive technology with all connected accessories including 1000 ltrs compressed air container and replacement of unserviceable spares/ misc items with new one complete.
Note: (i) The rated quoted by the contractor is deemed to be included all the Misc/ Sprares required for completion of job satisfactorily
(ii) All repairs/servicing /maintenance shall have to be carried out by the authorised service personnel
3
-
10
... More
Supply and Fix quality Industrial Type Air Filter cum regulator integral of Make Kobalt ingersolrand with suitable pressure guage and air regulator arrangement suitable for 40mm dia bore tube by replacing the unserviceable complete all as directed
2
-
10
... More
Supply and lay 32mm heavy grade MS Pipe along with fittings including replacing the corroded pipe complete all as directed
15
-
10
... More
Supply and lay 20mm heavy grade MS Pipe along with fittings including replacing the corroded pipe complete all as directed
15
-
10
... More
Supply and Fix 32mm Stainless steel globe valve along with misc items as per site by replacing the unserviceable complete all as directed
2
-
10
... More
Supply and Fix 20mm Stainless steel ball valve along with SS reducer & Quick couples and plug set as per site by replacing the unserviceable complete all as directed
10
-
10
... More
M&L for servicing of 100 KW Solar PV integrating with 100 KVA OPSPCU With 400 nos of 250 Wp each SPV panel Integrated with 800AH x 2 total of 1600 AH battery bank complete all as specified and directed below :-
2
-
10
... More
a) Solar Photovoltaic Modules total nos 400 of 250 Wp each:
The contract includes checking all the 400 panels in terms of generations and also check the wires and Junction box panel wise check the nuts and bolts secure the loose contacts of DC cables and also the fix the panels in case of any panel falling down with suitable nuts, bolts and washers etc.
-
-
-
... More
b) Array Structure used in the project
All the legs will of the galvanized Structure shall be checked for firmness on the ground and in case it is loose shall be tigthend further so as to ensure no loose legs, the bolts of legs purlins and the entire structure shall be checked and in case any nuts/bolts or missing rusted shall be replaced with new ones, The tilt angle if distorted shall be rectified for the maximum angle of solar radiation on the panel
-
-
-
... More
c) Main Junction Box
The AJB or the Array junction box shall be checked for the power flow and also for power generation per array with clamp meter and also all the fuses MCBs shall be checked for efficiency so as to ensure the connected array solar power is captured at the MJB level, defective fuses, connectors etc should be replaced
-
-
-
... More
d) Array Junction Box and Main Junction Box The AJB or the Array junction box shall be checked for the power flow and also for power generation per array with clamp meter and also all the fuses MCBs shall be checked for efficiency so as to ensure the connected panels solar power is captured at the AJB level, defective fuses, connectors etc should be replaced
-
-
-
... More
(e) AC Distribution Box (ACDB)
The AC Distribution Panel Board (DPB) will control the AC power from inverter, and have the necessary surge arrestors. There will be an interconnection from ACDB to mains at LT Bus bar and the complete set of equipment along with metering will be installed the ACDB. Check the cable glands, at the ACDB, check for LT Bus bar and the surge arrestors for proper functioning and in case of minor corrections shall be carried out and in case any major fault estimate for the same shall be given separately for approval
-
-
-
... More
(f) Cables and Wires:
Check the insulations and terminals and peel offs in the cable and wire and in case of minor issues insulations for closing shall be carried out and in case of requirement of replacement shall give the estimate for replacement if so required.
-
-
-
... More
g) Power Cable Check the power cable for connectivity upto inverter from the MJB and also ensure that the terminals and cable has no fault
-
-
-
... More
h) HYBRID DSP –GSC Inverter & MPPT Charge Controller- power conditioning unit
(i) Cleaning and dusting of the PCU for dust accumulation and for moisture ingress shall be done in conformity with the requirement. (ii) The outgoing MCCB and circuits shall be done during the visit check for efficiency and in case any replacement is required it shall be estimated for approval.
(iii) Check The Peak load shaving (PLS) feature is available which utilizes batteries based on battery state of charge (SOC) thus optimising grid usage. PLS feature provides for extending battery life as the battery is discharged under controlled conditions. Check DC fuses and incase of non functional DC fuses it shall be rectified. IGBT shall be checked HF Phase Inductors shall be checked, Induction breaker s shall be checked exhaust fans working shall be checked and in case of fault replacement quote shall be given for approval. (iv) Check Renewable resources are fed directly to the site load via the inverter as much as possible to minimise losses due to battery inefficiency. (v) Check the integratration of renewable/distributed generation sources on both the AC and DC bus.
-
-
-
... More
j) Batteries
Check all the Battery cells and remove the hot air accumlation from all the batteries so that the battery temparature is optimised, check if any battery terminals are leaking and clean all the battery terminals, secure the terminals so as to ensure there is no loose bolts and nuts, check the interconnection and secure the same in case of any loose or disconnection of the cables and terminals.
Check battery temparature and also the battery efficiency and in case of requirement any one cell the same shall be estimated and the budget shall be given for approval.
-
-
-
... More
M&L for servicing of ELECTRIC CHIMNEY/Fume exhaust system (chimney) electrically operated with centrifugal blower driven by 7.5 HP, 1440 RPM, 415 V, 50 Hz, 3 Phase electric induction motor suitable or as directed by OEM for achieving 8000 CFM as per site condition / as per actual requirement to extract the fume alongwith suitable variable frequency drive (VFD) starter with digital display, for exhaust blower capacity of 8000 CFM or as per OEM design as per site condition to extract all the fumes with the following accessories:- (a) Exhaust hood island type with double side, grease filters made out of 20 SWG SS 304 grade stainless steel sheet with stain steel filters of hood size 1.50m x 0.60m - 06 Nos with suitable damper for adjusting the air flow including suitable civil works and mild steel brackets for fixing / mounting complete all as specified and as directed. (b) Exhaust hood island type with single side, grease filters made out of 20 SWG SS 304 grade stainless steel sheet with stain steel filters of hood size 0.90m x 0.90m (toaster oven) - 04 Nos including suitable civil works and mild steel brackets for fixing / mounting complete all as specified and as directed.
Note:- (a) All civil works such as making opening in brick / stone walls including to make good to match with the surroundings, mounting plinth for blower motor assembly etc., shall be carried out by the contractor and the cost of the same shall be deemed to be included in the rate quoted. (b) All mild steel brackets, supports, clamps etc., as required shall be carried out by the contractor and the cost of the same shall be deemed to be included in the rate quoted. (c) Sub-main wiring and control switches as required shall be measured separately under appropriate items of BOQ. (d) After completion of installation the whole system shall be tested for its CFM. (e) Test certificate for motor, blowers, GI sheets etc., shall be submitted duly tested from NABL accredited lab.
1
-
10
... More
Taking down existing and refixing after repairs of GI ducting made out of 22 SWG GI sheet alongwith mild steel flanges and mild steel brackets for fixing on wall / ceiling including suitable dampers and fixing arrangements for the blowers etc., complete all as specified and as directed. Note:- All incidental civil works like make holes in wall and making good disturbed surfaces for taking down/ refixing are deemed to be included in the rates quoted,
35
-
10
... More
M&L for Preparing the external surfaces of the servo stabilizers of capacities 10 KVA to 15 KVA by CTC and emery paper removing the oil stains applying two coats of approved superior quality synthetic enamel paint by spraying including writing of SM/MES number, capacity etc., complete all as specified and as directed by Engineer-in-Charge.
3
-
10
... More
All as per Ser Item No 20 above but capcity 40KVA.
3
-
10
... More
All as per Ser Item No 20 above but capcity 150KVA.
3
-
10
... More
Supply and fixing of following spares for repairing /servicing the voltage stabilizer/isolating transformer vide item no 20 to 22:- (a) Panel Lamp
2
-
10
... More
(b) Push Button Switch
2
-
10
... More
(c) Auto Manual Switch
2
-
10
... More
(d) DPDT Switch
2
-
10
... More
(e) Carbon Brush
2
-
10
... More
(f) Micro Switch
2
-
10
... More
(g) Potentiometer
1
-
10
... More
(h) Trigger Transformer
1
-
10
... More
(j) Rotary switch 5 Amp for RYB phases
2
-
10
... More
(k) Volt Meter
1
-
10
... More
(l) Ampere Meter with CT 100/5 A.
1
-
10
... More
(m) Electronic Circuit Card(PCB) for 40KVA & 150 KVA Stabilizer
1
-
10
... More
(n) Servo Motor 3 KG torque for 15 KVA Stabilizer
1
-
10
... More
(o) Servo Motor 10 KG torque for 150 KVA Stabilizer
1
-
10
... More
(p) Complete Micro Processor Based Panel for 150 KVA Stabilizer
1
-
10
... More
(q) Drive Assembly upto 75 KVA per Phase
1
-
10
... More
(r) Dimmerstat 10 KVA 10 Amp
1
-
10
... More
(s) Dimmerstat 40 KVA 28 Amp
1
-
10
... More
(t) Main Transformer for 10 KVA
1
-
10
... More
(u) Rewinding of Unserviceable transformer (for R Phase) with suitable guage winding wire, insulating,varnishing and setting back for 150 KVA Stabilizer
1
-
10
... More
(v) All as item No 15 for 'Y' Phase of Stabilizer capacity upto 40 KVA
1
-
10
... More
(w)All as item No16 for 'Y' Phase of Stabilizer capacity upto 150 KVA
1
-
10
... More
Supply and filling up of Insulating transformer oil including replacing the minor parts like nuts, bolts, washers, gaskets etc., clean the oil sump thoroughly and filling with new transformer oil duly filtered to achieve dielectric strength of minimum 40 KV at 2.5mm gap complete all as specified and all as directed by Engineer-in-charge for Servo Stabilizer and Isolation Transformer. Make: Electrol/Power Oil/ CASTROL/SAVSOL
280
-
10
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements