For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_672843_1Bid Award Id
ViewTender No
81228/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIRS AND MAINT OF HT NETWORK INCLUDING TRANSFORMERS AND OTHER ASSOCIATED WORKS UNDER GE GOLCONDA
BOQ Items
Supply and fix HT 11 KV, 150 mm height and 150 mm dia pin type insulator, porcelain, vitreous, white/brown/green, conforming to IS-2486 for 11000 Volts grade including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut including taking down of old U/S insulator complete all as specified and directed.
22
-
-
M & L for Stay assembly complete with all accessories as shown in electrical plate No. 1 of SSR Part-I using 20mm dia stay rod incl taking down of old U/S stay assembly including excavation and PCC work complete all as specified and directed.
6
-
-
M & L for Loop type insulator, vitreous porcelain, white, brown or green, large size with overall dimension 90x140mm clearance of hole 25.5mm incl taking down of old U/S insulator complete all as specified and directed.
12
-
-
M & L for galvanised stay stand, size 7/3.15mm complete all as specified and directed.
0.5
-
-
Dismantling of unserviceable steel tubular pole any size upto 11mtr long including breaking up PCC and making good disturbed surface and removing materials from site of work complete all as specified and directed.
7
-
-
M & L for Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11m long) conforming to IS-2713 (Part-I & II) including painting of pole with two coats of aluminum paint over a coat of red oxide primer from top of the pole to 1.5m above the bottom of the pole and painting with two coats of black paint over a coat of red oxide primer upto 1.5m from bottom of the pole complete all as specified and directed.
7
-
-
Dismantling of unserviceable concrete pole any size upto 11mtr long including breaking up PCC and making good disturbed surface and removing materials from site of work complete all as specified and directed.
10
-
-
M & L Prestressed concrete pole, 11.0metres long 152mm x 152mm at top and 152mm x 260mm at bottom,class 9 all as specified and directed.
10
-
-
Supply, install, testing and commissioning single pole lightening arrestor, gapless metal oxide out door type complete with all fittings, distribution class, discharge capacity 30 KA suitable for 11000 Volts grade including necessary connection and fittings all as per IS-3070 Part-III and IEC 1994 including dismantling of existing lightening arrestor complete all as specified and as directed.
15
-
-
Supply, laying, connecting and testing XLPE insulated (Earthed) cable in trenches/or fixed on pole etc in screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 Volt grade, cross sectional area 95 Sqmm, 3 Core Conforming to IS-7098 (Part-II)-1985 incl taking down of old U/S HT UG cable complete all as specified and directed.
(Note: Excavation & earth work will be measured and paid separately)
200
-
-
Supply, laying, connecting and testing XLPE insulated (Earthed) cable in trenches/or fixed on pole etc in screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 Volt grade, cross sectional area 120 Sqmm, 3 Core Conforming to IS-7098 (Part-II)-1985 incl taking down of old U/S HT UG cable complete all as specified and directed.
(Note: Excavation & earth work will be measured and paid separately)
150
-
-
Supply and Fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete including taking out old unserviceable one all as specifide and directed.
10
-
-
M&L for cable end termination, heat shrinkable, outdoor type, suitable for 3 core x 120 to 185 Sqmm HT, 11 KV cable with necessary lugs complete all as specified and directed.
(Note:- Earth work excavation, sand cushioning and cable protection will be measured and paid separately under relevant items of this schedule )
10
-
-
M&L for HT 11 KV straight through joint, heat shrinkable type, suitable for 3x50 to 95 Sqmm size cable complete all as directed by complete all as specified and directed at site.
(Note:- Earth work excavation, sand cushioning and cable protection will be measured and paid separately under relevant items of this schedule )
10
-
-
M&L for HT 11 KV straight through joint, heat shrinkable type, suitable for 3x120 to 185 Sqmm size cable complete all as directed by complete all as specified and directed at site.
(Note:- Earth work excavation, sand cushioning and cable protection will be measured and paid separately under relevant items of this schedule )
8
-
-
Supply and laying 100 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under ground including taking down old one complete all as specified and as directed.
13
-
-
Supply and fixing triple pole mechanically operated air break isolator (GOD), Horizontal mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from one meter above ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz, with 9 insulator of rating upto 200 Amps including taking down old U/S GOD complete all as specified and directed.
12
-
-
Servicing of Horizontal/vertical mounted GOD including greasing of all moving parts, tightning of Male and female contacts including all connected parts of GOD to make it operate smothly complete all as directed and specified.
26
-
-
S & F drop out fuse single pole mounted on insulator, 11000 Volts grade double pole steel frame of current rating 50 Amps including taking down existing DO fuse complete and removing from site complete all as specified and directed.
12
-
-
Tightening and straightening of HT overhead line of ACSR conductor of 3 Phase including GI wire of any size and span of upto 45 Meter by disconnecting and removing from insulators and tightening the conductor by using rope, chain pulley block etc and binding the conductor on insulators with and including binding wire and jumpers of ACSR complete all as directed.
30
-
-
Materials and labour for danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters of HT 11KV / Transformer Capacity and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT, 25 x 20 cm size including dismantling of old one complete all as specified and directed.
Note : HT 11KV / Transformer Capacity shall be mentioned on Danger Notice plate.
20
-
-
M&L for underground HT Cable fault locating testing with appropriate cable fault locator machine from authorised company complete all as specified and directed by Engr-in-Charge. Note : Quoted rate includes complete cable fault testing and transport of machinery.
5
-
-
Supply and Fix brass terminal plate for mounting male contact of air break switch insulator including GI nuts and bolts washers etc as required complete
15
-
-
Supply and Fix male contact for air break switch
20
-
-
Supply and Fix female contact for air break switch
20
-
-
Supply and Fix post insulator for air break switch with metal part suitable for HT 11 KV conforming to IS-5572-1972
12
-
-
Supply and Fix DO insulator suitable for 11 KV with metal part conforming to IS-5572-1972.
12
-
-
Supply and Fix dropout fuses top/bottom contact
12
-
-
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in hard/dense soil including taking out brick protection etc complete all as specified and directed.
109
-
-
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
69
-
-
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
40
-
-
Supply and spread sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide required cover after punning down complete all as specified and directed.(Note: Only Punned thickness after punning will be measured and paid)
24
-
-
Supplying and laying reinforced precast concrete cable cover class HV, Type 1 flat of size 300x180x40 mm all as specified and directed.
1575
-
-
Material and labour for hardcore of broken stone of boulder of gauge not exc 63mm deposited, spread and levelling in layers not exc 15cm thick watering and ramming to true surface all as specified and directed.
30
-
-
M&L for cleaning thoroughly HT steel tubular poles of any height and any description with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping , complete all as specified and directed .
90
-
-
M&L for cleaning thoroughly two pole structure complete of any height and any description with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping , complete all as specified and directed.
20
-
-
M&L for cleaning thoroughly the four pole structure complete of any height and any description with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping , complete all as specified and directed.
18
-
-
M&L for cable route indicator made of GI round plate 100 mm dia (marked with HT 11 KV Cable) fixed on GI angle 25x25x5 mm (total length 500mm), height 200 mm above GL and 300 mm below GL shall be inserted on pit size 200x200x300, grouted in PCC 1:2:4 type B1 complete all as specified and directed inculding taking down the old cable route indicator.
Note: Earth work and PCC shall not be measured and paid seperately and is deemed to be included in quoted rate.
34
-
-
Cutting & trimming of tree branches any girth and size touching to overhead lines and cleaning the distance 1.5 mtr both sides of overhead line with in a gap of span upto 50 mtrs each and removing the same cleaning the site all as specified and directed.
180
-
-
Disconnecting defective oudoor/indoor power distribution transformer of various sizes/capacties from HT/LT and earth conection and taking out from two pole structure/plinth and removing out complete transformer oil, storing the same in suitable containers (to be provided by contractor) opening top cover and lifting up the core assembly carefully to check the condition of transformer winding core refixing the same after repair refilling the transformer oil after dehumidification and filteration (dehumidification and filteration to be measured and paid separately under respective items ) including checking of leakage of transformer body and welding works required for making transformer body leak proof including transportation of transformer from site to work shop and re-installing the same at any site and painting of transformer as directed by at site. for transformer of capacity upto 100 KVA all as specified and as directed.
Note : The materials required for rectification of defects such as rewinding / transformer oil / bushes etc will be measured and paid separately.
3
-
-
All as per item No.43 here in before but for transformer of capacity 125 KVA and up to 160 KVA all as specified and as directed.
1
-
-
All as per item No.43 herein before but for transformer of capacity 200 KVA to 250 KVA all as specified and as directed.
3
-
-
All as per item No.43 here in before but for transformer of capacity 300 KVA all as specified and as directed.
1
-
-
All as per item No.43 herein before but for transformer of capacity 500 KVA all as specified and as directed.
1
-
-
Removing the burnt out HT winding of transforme of capacities upto 500KVA and rewinding with braided copper conductor to match with that existing gauge and No of turns all as specified and as directed.
190
-
-
All as per item No.48 here in before but for LT windings all as specified and as directed.
210
-
-
Removing the burnt out/damaged insulation of complete LV winding and reinsulating with new insulation of complete LV winding of transformer of capacities upto 500 KVA.
[Note: Quantity is measured on insulation carried out on each Kg of LV winding]
50
-
-
After completion of Rewinding of Tranformer HT winding up to 500 KVA, the rewinded each core along with winiding is kept in oven with constant Temparature of 80°C for 48 hours for better insulating process of HT winding complete all as directed.
5
-
-
Replacement of silica gel breather with and including silica gel as per the existing size / model at site all as specified and as directed.
24
-
-
Replacement of temperature gauge as per the existing size / model at site all as specified and as directed.
16
-
-
Removing the burnt out LV bushes and replace the same with new Brass LV bushes, nuts , check nuts etc complete as that of existing size / model, for transformers of capacity 63 KVA to 100 KVA all as specified and as directed.
16
-
-
All as per item No.54 here in before but of capacity 125 KVA to 160 KVA all as specified and directed.
8
-
-
All as per item No.54 here in before but of capacity 200 KVA to 250 KVA all as specified and directed.
8
-
-
All as per item No.54 here in before but of capacity 300 to 500 KVA all as specified and directed.
6
-
-
Removing the burnt out HV bushes and replace with Brass HV bushes, nuts , check nuts etc complete as per the existing size / model, for transformers of capacity up to 500 KVA all as specified and as directed.
26
-
-
Removing the burnt out LV side insulators and replace the same with new Insulator complete as that of existing size / model, for transformers of capacity 100 KVA to 250 KVA all as specified and as directed.
8
-
-
Replacement of synthethetic rubberised cork sheet gasket 1/4" thick suitable for main body of transforemr capacity 63 KVA to 125 KVA all as specified and as directed.
7
-
-
All as per item No.60 here in before but of capacity 160 KVA to 250 KVA all as specified and directed.
8
-
-
All as per item No.60 here in before but of capacity 300 to 500 KVA all as specified and directed.
2
-
-
Removing the old HT OFF load tap changer and supply and install of suitable size with tapping arrangement 2.5% to 3.5% and on normal tapping of transformer capacity 63 KVA to 100 KVA all as specified and as directed.
3
-
-
All as per item No.63 here in before but capacity 125 KVA to 250 KVA all as specified and directed.
4
-
-
All as per item No.63 here in before but capacity 300 KVA to 500 KVA all as specified and directed.
1
-
-
Dehumidification and filteration of transformer oil at different locations by dehumidification plant including testing of oil samples both before and after filteration all as specified and as directed . The dielectric strength of the transformer oil shall be not less than 40 KVA with 2mm gap after filtration.
Note : (a) The qoated rate shall be deamed to include necessary T&P for collection of transformer oil sample, Testing Kit, Filteration plant and also include for making necessary connection to filtration plant from transformer and switch gear. (b) Test result obtained shall be recorded and produced to Engineer-in-charge and kept in record.
3850
-
-
Supply and filling transformer oil low viscosity of approved make/quality with rupturing capacity 60 KV for 60 Seconds suitable for 11 KV tansformer as per IS 335 of 1983 all as specified for topping up/replacement all as directed at site.
Make : Servo or equivalent as approved.
Note : The Transformer Oil shall be ISI Marked and brought at site in sealed container only.
1700
-
-
Supply, fix, connect commission and test power capacitor bank MPP out door type operating 3 phase 415 volt AC suply 50 HZ confirmed to IS:2834 complete with necessary bolts and nuts, earth strip connected from LT panel to capacitor bank including suitable copper cable single core multistranded with necessary lugs for inter connection of capacitor bank 5 KVAR complete all as specified including disconnecting and removing existing unserviceable power capacitor bank. and all as specified and as directed.
20
-
-
All as per item No.68 above but 7.5 KVAR
12
-
-
All as per item No.68 above but 10 KVAR
10
-
-
All as per item No.68 above but 20 KVAR
6
-
-
S & Fix, connect and test Capacitive Duty Contactor for capacity 1 KVAR to 3 KVAR capacitor bank complete all as specified including disconnecting and removing existing unserviceable duty contactor and all as specified and as directed.
8
-
-
All as per item No.72 above but for 5 KVAR to 10 KVAR
8
-
-
All as per item No.72 above but for 20 KVAR
2
-
-
Earthing complete with galvanised steel earth plate electrode of size 60cm X 60cm X 6.3mm buried directly in ground (earth pit not less than 2.25 metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI earth strip 32 mm x 6 mm by means of GI bolts, nuts, check nuts and washers and earth strip protected by 40 mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completion.Notes: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Cement Earth pit and pit cover, GI funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II and also refer Plate No-03. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately. Note :- Earthing shall be redone if desied earth result not found during testing of the same at site.
12
-
-
Description same as per item No.75 above but using galvanised iron strip 25×4mm as earthing lead
7
-
-
Description same as per item No.75 above but by using copper plate 60×60cm ×3.15mm thick electrode and 20 × 3mm copper strip as earthing lead complete all as specifed and directed.
4
-
-
M&L earth continuity conductor GI of 32x6 mm of GI strip fixed by means of bolts, nuts, check nuts and GI washers complete all as specified and directed.
32
-
-
M&L earth continuity conductor GI of 25x4 mm of GI strip fixed by means of bolts, nuts, check nuts and GI washers complete all as specified.
40
-
-
M&L Synthetic insulating mat (rubber matting), ISI Marked suitable for 11KV electrical grade 2m X 1m X 25mm thick chequered top, ISI marked to be laid in front of LT panel board complete all as specified and directed.
18
-
-
M&L for Danger notice boards of 1.6mm thick mild steel sheet, vitreous enamelled white,with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 25x20cm size all as specified and as directed.
20
-
-
Disconnecting defective oudoor/indoor power distribution transformer of various sizes/capacties from HT/LT and earth conection and removing out complete transformer oil, storing the same in suitable containers (to be provided by contractor) opening top cover and to check the condition of LV ,HV Bhushes and Gasket Kit and replacing with new LV, HV bhushes and Gasket kit and refixing the transformer top cover after filling the transformer oil and dehumidification and filteration (dehumidification and filteration to be measured and paid separately under respective items ) of transformer of capacity 63 KVA to 125 KVA all as specified and as directed. Note : LV Bushes,HV Bushes and Gasket Kit and oil filteration will be measured and paid seperately.
6
-
-
All as per item No.82 above but for capacities above 160 KVA to 250 KVA.
6
-
-
All as per item No.82 above but for capacities above 300 KVA to 500 KVA.
1
-
-
M&L for cutting of road, hard standing of approx depth 2 meter made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cables all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc., required to match with the existing surface complete all as specified and directed.
20
-
-
M&L for cement concrete for foundation, filling and mass concrete type D2 1:4:8 with 40 mm graded aggregate for steel tubular swaged poles complete all as specified and directed.
1.1
-
-
M&L for cement concrete for foundation, filling and mass concrete type C2 1:3:6 with 40 mm graded aggregate for steel tubular swaged poles complete all as specified and directed.
8.9
-
-
M&L for cement concrete for coping, type B1 1:2:4 with 20 mm graded aggregate including necessary form work for steel tubular swaged poles complete all as specified and directed.
0.8
-
-
Evaluation Notes How It Works ?