Military Engineer Services Tender

For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Military Engineer Services - MES Tender

Works
Civil And Construction
Drainage Work
Eprocure
Opening Date31 Jan 2025
Closing Date21 Feb 2025
Tender Amount₹ 23,25,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PERIODICAL MAINT OF SEWAGE PUMPING LINES AND SEWAGE INSTALLATIONS AT AFA HYDERABAD
PERIODICAL MAINT OF SEWAGE PUMPING LINES AND SEWAGE INSTALLATIONS AT AFA HYDERABAD
PERIODICAL MAINT OF SEWAGE PUMPING LINES AND SEWAGE INSTALLATIONS AT AFA HYDERABAD
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(c) Semi under ground Secondary settling Tank Capacity 114.8 Cum

1

-

-

... More
(d) Semi under ground Clarified water Tank Capacity 82.51 Cum

1

-

-

... More
(e) Sludge Holding Tank Capacity 28.7 Cum

1

-

-

... More
(f) Sludge Drying Bed Capacity 11.17 Cum

1

-

-

... More
(g) Treated water Tank Capacity 224 Cum

1

-

-

... More
M & L for cleaning of Sewage treated water tank at FCM sports ground capacity 50,000 ltrs by scrapping the internal surfaces with steel wire brushes, after pumping out water(appx 45000Ltrs) completely by using pump set, removing silt/debris descaling with solution and removal of silt debris, repair minor cracks and applying water proofing compound chemical and making leak proof including applying two coats of lime white wash internally and externally above ground, and applying two coats of synthetic enamel paint to inlet pipe above ground level and man hole cover/grills/wire mesh and two coats of tar epoxy over one coat of red oxide primer to the up and down ladders, cleaning the internal surface of the tank to the complete satisfaction and as directed by the Engineer-in-charge .

1

-

-

... More
(a)All as per item no.2 OMQ area sump capacity 64500 Ltrs

1

-

-

... More
(b) All as per item no.2 SMQ area sump capacity 60,000 Ltrs

1

-

-

... More
(c) All as per item no.2Type-I area sump capacity 44700 Ltrs

1

-

-

... More
(d) All as per item no.2Golf area sump capacity 13500 Ltrs

1

-

-

... More
M&L for Cleaning of Sumps, Chambers etc, by removing sludge, mud, debris and foregin materials by scraping all the surfaces with wire brushes, scrapers, ..etc and removing the sludge, debris, and foregin materials etc to a distance not exceeding 150 mtr away from Sewage pump house site, cleaning with fresh water (internally) and disinfectant solution complete all as required, including applying of two coats of lime white wash internally complete all as directed by the Engineer-in-Charge for the capacity 50,000 Ltrs of old pump house sump :- ( Sewage pump house no.I)

1

-

-

... More
All as per item no.3 of new sewage pump house sump capacity 50,000 Ltrs

1

-

-

... More
All as per item no.3 of over flow sump capacity 30,000 Ltrs

1

-

-

... More
M&L for disconnecting the suction and delivery pipe lines and electric connections for Non clog centrifugal pump sets of Sewage Installations of following capacities servicing it throughly and carrying out the repairs such as replacing the worn out winding and worn out bearings at non-drive and drive end of pump shaft/ bushes, gland rope, nuts, bolts, washers, greasing and bringing it to workable condition and connecting up of suction and delivery pipe lines and electric connections incl testing complete all as specified and as directed for the following capacity pump sets :- Note :- (i)The unit rate quoted against the item includes cleaning / repairs, replacement of minor items such as nuts, bolts, gland rope, packing materials etc

-

-

-

... More
(a) 2 HP, 3 phase 415 volts

4

-

-

... More
(b) 5 HP, 3 phase 415 volts

2

-

-

... More
(c) 7.5 HP, 3 phase 415 volts

2

-

-

... More
(d) 10 HP, 3 phase 415 volts

5

-

-

... More
(e) 12.5 HP, 3 phase 415 volts

3

-

-

... More
(f) 25 HP, 3 phase 415 volts

2

-

-

... More
(g) 30 HP, 3 phase 415 volts

2

-

-

... More
Supply only CI / gun metal bushes of suitable size for 2 HP centrifugal pump set complete all as specified and as directed.

6

-

-

... More
Supply only CI / gun metal bushes of suitable size Non Clog centrifugal pump sets complete all as specified and as directed for the following capacity:-

-

-

-

... More
(a) 5 HP, 3 phase, 415 volts

4

-

-

... More
(b) 7.5 HP, 3 phase, 415 volts

4

-

-

... More
(c) 10 HP, 3 phase, 415 volts

4

-

-

... More
(d) 12.5 HP, 3 phase, 415 volts

4

-

-

... More
(e) 30 HP, 3 phase 415 volts

4

-

-

... More
Material and labour for CI coupling by casting, machining such as turning, milling etc complete to suitable for Non clog centrifugal pump set complete all as specified and as directed for the following capacity :-

-

-

-

... More
(a) 5 HP, 3 phase, 415 volts

4

-

-

... More
(b) 7.5 HP, 3 phase, 415 volts

4

-

-

... More
(c) 10 HP, 3 phase, 415 volts

4

-

-

... More
(d) 12.5 HP, 3 phase, 415 volts

4

-

-

... More
(e) 30 HP, 3 phase 415 volts

4

-

-

... More
M&L for Repairs / replacement of glands/gate and refix with grease, valve spindle of stainless steel with brass check nut etc for CI sluice valves including valve head gasket, gland packing, new nut bolts, washers etc complete all as specified and as directed for the following sizes

-

-

-

... More
(a) 200 mm bore

2

-

-

... More
(b) 150mm bore

3

-

-

... More
(c) 100mm bore

2

-

-

... More
(d) 80mm bore

3

-

-

... More
Supply and Fix DI (ductile iron) pipes , Class K-9, spigot and socketed ends, of size 150 mm conforming to IS- 8329:2000 in any length, laid in trenches including jointing materials such as rubber tyton joints complete all as specified and as directed by Engineer-in-Charge.

5.5

-

-

... More
(a) 100mm bore

11

-

-

... More
(b) 80mm bore

11

-

-

... More
Dismantling the existing Type coupling supply and fixing new type coupling bringing it to workable condition and fixing in location all as required at site complete all as specified and a directed

6

-

-

... More
M& L for Painting of Non clog centrifugal pump set of following capacity including inlet and outlet CI pipes, non return valves, sluice valves, base plate etc complete with two coats of synthetic enamel paint including cleaning the surfaces complete all as specified and a directed for the following :-

-

-

-

... More
(a) 2 HP, 3 phase 415 volts

4

-

-

... More
(b) 5 HP, 3 phase 415 volts

3

-

-

... More
(c) 10 HP, 3phase 415 volts

7

-

-

... More
(d) 12.5 HP, 3phase 415 volts

4

-

-

... More
(e) 30 HP, 3 phase 415 volts

3

-

-

... More
Taking down the unservicable non return valve from position after disconnecting the unserviceable valve of size 150mm ISI marked heavy duty with handle including necessary nuts bolts washers etc complete all as specified and a directed

3

-

-

... More
All as per item no 14 above but of size 100 mm

3

-

-

... More
All as per item no 14 above but of size 80 mm

3

-

-

... More
Supply and fixing non return valve from position after disconnecting the unserviceable valve of size 150mm ISI marked heavy duty with handle including necessary nuts bolts washers and modification etc complete all as specified and a directed

3

-

-

... More
All as per item no 17 above but of size 100 mm

3

-

-

... More
All as per item no 17 above but of size 80 mm

3

-

-

... More
Taking down unservicable sluice valve from position after disconnecting the unserviceable sluice valve of size 200 mm dia ISI marked PN 1.6 heavy duty with handle including necessary nuts bolts washers etc complete all as specified and a directed

1

-

-

... More
All as per item no 20 above but of size 150 mm

2

-

-

... More
All as per item no 20 above but of size 100 mm

2

-

-

... More
All as per item no 20 above but of size 80 mm

2

-

-

... More
Supply and fix sluice valve of size 200 mm dia ISI marked PN 1.6 heavy duty with handle including necessary nuts bolts washers and modification etc complete all as specified and a directed

1

-

-

... More
All as per item no 24 above but of size 150 mm

2

-

-

... More
All as per item no 24 above but of size 100 mm

2

-

-

... More
All as per item no 24 above but of size 80 mm

2

-

-

... More
S & F cast iron/DI specials such as bends, collar and tee etc any type of size up to 150 mm bore as per site requirement complete all as specified and as directed by Engineer-in-Charge. Note : -The necessary earth work excavation, lead joints etc will be measured and paid separately.

150

-

-

... More
M&L for burning out old lead joint and taking out lead and M&L for new Run lead joints complete all as specified and as directed for the follwoing pipes :- Note:- Earth work and excavation will be measured and paid separately.

-

-

-

... More
(a) 200 mm bore pipe

4

-

-

... More
(b) 150 mm bore pipe

4

-

-

... More
(c) 100 mm bore pipe

4

-

-

... More
(d) 80 mm bore pipe

4

-

-

... More
M&L for disconnecting the suction and delivery pipe lines and electric connections for Air compressor of capacity 250m3/hr, blower speed 1237 RPM, pressure 0.45 kg/cm2 and motor power of 10 HP servicing it thoroughly and carrying out the repairs such as replacing the worn out belts and worn out bearings at non-drive and drive end of pump shaft/ bushes, nuts, bolts, washers, greasing and bringing it to workable condition and connecting up of suction and delivery pipe lines and electric connections incl testing complete all as specified and as directed for the following capacity pump sets :- Note :- (i)The unit rate quoted against the item includes cleaning / repairs, replacement of minor items such as nuts, bolts, gland rope, packing materials etc removing it from its existing position carefully and transporting the same to the work shop, dismantling/opening up the compressor and motor for inspection, repairs/replacing the worn out unserviceable parts with new one including cleaning, lubricating, replacing the minor items like, , studs, nuts, bolts, washers etc, reassembling the pump sets including painting with two coats of synthetic enamel paint, transporting back and refixing the same in its original position including connecting up the water and electric connections, testing and commissioning complete all as specified and directed by the Engineer-in-charge

3

-

-

... More
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr in depth in hard and dense soil and getting out for repairs to water mains / valves / valve chamber including forming bottom surface to required level and gradient complete all as specified and as directed

15

-

-

... More
Returning filling in including spreading, levelling, watering and well ramming, in layers not exceeding 25 cm thick in soil complete all as specified and as directed

12

-

-

... More
Removing the surplus soil not exceeding 50 M and depositing where directed by Engineer-in-charge at a level not exceeding 1.5 Mtr above the starting point complete all as specified and gradient complete all as specified and as directed

3

-

-

... More
Supply and fixed in repairs buttter fly valve of 100 mm dia including necessary gaskets and fittings etc complete all as specified and as directed.

4

-

-

... More
Supply and fixed in repairs buttter fly valve of 80 mm dia including necessary gaskets and fittings etc complete all as specified and as directed.

4

-

-

... More
Supply and fixed in repairs star delta starter fully automatic type ML-2, 3 Phase, 415 Volts for 30 HP complete with Over load relay, single phase preventor, on off switch etc complete all as specified and as directed.

5

-

-

... More
Supply and fix , connect and test DOL starter type MK-1 with sheet steel enclosures, 3 phase, 415 volts, 50 Hz suitable for motor out put of 5 HP complete all as specified and as directed.

3

-

-

... More
Supply and fixed in repairs star delta starter with stainless steel enclosure fully automatic type ML -1.5, 3 Phase, 415 Volts, 10 HP to 20 HP complete with Over load relay, single phase preventor, on off switch etc complete all as specified and as directed.

4

-

-

... More
Supply and refill only calcium hypochlorite 65% to 70% chlorine content in granular form of a chlorination / disinfectant agent having zero mercury & zero heavy metal contamination property and should not induce substances beyond acceptable limit as given in IS 10500(2012) in treated and disinfected water and also having high chlorine stability period upto one year duly packed in sealed drum complete all as specified and directed. as approved by GE.

315

-

-

... More
Supply and refill only TCCA-90 (Trichloro Isocyanuric Acid) in white granular form for disinfectant for swimming pool of super quality contains chlorine 90% duly Packed in 50 kg sealed drum complete all as specified and as directed by Engineer - in -Charge and as approved by GE.

300

-

-

... More
Supply and lay Heavy duty HDPE pipe violet/purple coloured of dimention and specification shall be as per IS-4984 and pressure rating 6 Kg/sqcm laid in trenches including necessary fittings such as elbows, tees, sockets, etc fixed complete of following sizes: - Note : (i) necessary earth work and excavation , RF&R and removal of soil item shall be measured and paid separately. a) 20 mm bore

300

-

-

... More
b) 90 mm bore all as above

500

-

-

... More
Supply and fix in repair Bib taps 20 mm, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule including taking down old one complete all as specified and directed by Engineer-in-Charge.

75

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.