Military Engineer Services Tender

For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Solar Installation and Products
Eprocure
Opening Date18 Sep 2024
Closing Date16 Oct 2024
Tender Amount₹ 35,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR, MAINTENANCE AND OVERHAULING OF DG SETS, AMF PANELS, OF VARIOUS LOCATIONS, SERVICING OF SOLAR WATER HEATERS AND CONNECTED WORKS AND REPAIR/RENAEWAL OF SEWAGE TREATMENT PLANT, TESTING, CLEANING, MAINTENANCE UNDER AGE E/M NO 1 OF GE (U) SECUNDERABAD
REPAIR, MAINTENANCE AND OVERHAULING OF DG SETS, AMF PANELS, OF VARIOUS LOCATIONS, SERVICING OF SOLAR WATER HEATERS AND CONNECTED WORKS AND REPAIR/RENAEWAL OF SEWAGE TREATMENT PLANT, TESTING, CLEANING, MAINTENANCE UNDER AGE E/M NO 1 OF GE (U) SECUNDERABAD
REPAIR, MAINTENANCE AND OVERHAULING OF DG SETS, AMF PANELS, OF VARIOUS LOCATIONS, SERVICING OF SOLAR WATER HEATERS AND CONNECTED WORKS AND REPAIR/RENAEWAL OF SEWAGE TREATMENT PLANT, TESTING, CLEANING, MAINTENANCE UNDER AGE E/M NO 1 OF GE (U) SECUNDERABAD
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No 1 here-in-before but 200 KVA to 250 KVA DG Set

6

-

-

... More
M&L for Renewal/Replacement of unserviceable batteries with maintenance free batteries of 150 AH, 12V including connecting to DG set complete all as directed by Engr-in-charge. Make:- EXIDE/ AMARON

1

-

-

... More
M&L for Renewal/Replacement of unserviceable batteries with maintenance free batteries of 180 AH, 12V including connecting to DG set complete all as directed by Engr-in-charge. Make:- EXIDE/ AMARON

1

-

-

... More
Attending the breakdown of any capacity/make DG Sets, AMF Panels, by Technician & helper for checking all components and rectify the fault and give report to concern JE complete all as directed by Engr-in-charge. Note :- Spare Parts for rectify the fault is measured and paid separately.

19

-

-

... More
M&L for Renewal/ repairs of unserviceable automatic voltage regulator (AVR) upto 50 KVA DG set including all spares, testing all as specified and directed by Engr-in-Charge. Make:- As per OEM approved make.

2

-

-

... More
M&L for Renewal/ repairs of unserviceable automatic voltage regulator (AVR) above 200KVA and upto 250 KVA DG set including all spares, testing all as specified and directed by Engr-in-Charge. Make:- As per OEM approved make.

1

-

-

... More
M&L for Dismantling of exhaust pipe of the DG set by unscrewing nuts and bolts and taking down the pipe with muffler removing the burnt out asbestos rope and well wrapping with new aluminium metal cladding with glass wool including cleaning the silencer, and fixing the same in its original position complete all as directed by Engr- in- Charge for the following capacity DG Sets up to 50KVA

2

-

-

... More
All as per item No 7 above but 200 KVA to 250 KVA DG set.

1

-

-

... More
M&L for Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 24 volts and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts like bearings, carbon brushes, clutch plates etc & assembling including after repair refixing the self starter in its original position, making all connection as per DG Set OEM recommendation, testing and commissioning complete all as directed by Engr-in-charge. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule.

1

-

-

... More
Supply only Armature coil for self starter of any make, any capacity and any model 24 Volts including testing complete all as directed by Engr-in-charge

1

-

-

... More
Rewinding of field coil for self starter of 24 volts with fine enameled copper conductor of same gauge with 'F' class insulation, size twins and weight with necessary insulating materials, gauge of conductor suitable any make, any capacity and any model complete all as directed by Engr-in-charge.

1

-

-

... More
M&L for Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 12 volts and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts like bearings, carbon brushes, clutch plates etc & assembling including after repair refixing the self starter in its original position, making all connection as per DG Set OEM recommendation, testing and commissioning complete all as directed by Engr-in-charge. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule.

1

-

-

... More
Supply only Armature coil for self starter of any make, any capacity and any model 12 Volts, 180/200 AH complete all as directed by Engr-in-charge

1

-

-

... More
Rewinding of field coil for self starter of 12 volts with fine enameled copper conductor of same gauge with 'F' class insulation, size twins and weight with necessary insulating materials, gauge of conductor suitable any make, any capacity and any model complete all as directed by Engr-in-charge.

2

-

-

... More
M&L for Disconnecting the oil cooler of capacity up to 50 KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed by Engr-in-charge

2

-

-

... More
M&L for Disconnecting the oil cooler of capacity above 200KVA to 250KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed by Engr-in-charge

1

-

-

... More
M&L for Renewal/ replacement of existing unserviceable air cleaning element inner and outer with necessary ‘O’ rings for the DG sets of following capacities as that of existing make and model complete all as directed by Engr-in-charge: - Make for item No.10 to 12.01 :OEM recommended Upto 50 KVA DG Set

3

-

-

... More
All as per item No 12 above but above 200 KVA and up to 250 KVA DG Set

1

-

-

... More
M&L for Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and various capacities of DG sets and taking down the radiator assembly by unscrewing all mechanical/electrical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of radiator assembly cleaning thoroughly the chocked pipe of the radiator by using chemical detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers and Anti vibrating mounting(AVM) pads as required as per OEM recommendation etc., for the following DG sets all as specified and directed by Engr-in-Charge: Upto 50 KVA DG Set

2

-

-

... More
All as per item No 13 above but above 200 KVA and up to 250 KVA DG Set

1

-

-

... More
M&L for Renewal of battery cable leads of copper conductor and with brass lugs terminal, for the 12V, 150/180 /200 AH batteries to self starter as that of existing size and length complete all as directed by Engr-in-charge

8

-

-

... More
S&F Automatic cut off type Battery Charger suitable for 12 V, up to 10 Amp Battery complete all as directed by Engr-in-charge. Make SMPS/ Phonix

2

-

-

... More
S&F Automatic cut off type Battery Charger suitable for 24 V, up to 10 Amp Battery complete all as directed by Engr-in-charge. Make SMPS/ Phonix

2

-

-

... More
M&L for Renewal/replacement of 'V' belts for the following capacity DG sets as per existing size and model complete all as directed by Engr-in-charge. Make :- FENNER/ DUNLOP Upto 50 KVA DG Set

2

-

-

... More
All as per item No 17 above but above 200 KVA and up to 250 KVA DG Set

1

-

-

... More
M&L for Renewal/replacement of fan belts for the following capacity DG sets as per existing size and model complete all as directed by Engr-in-charge. Make :- As per OEM Recommendation Upto 50 KVA DG Set

2

-

-

... More
All as per item No 18 above but above 200 KVA and up to 250 KVA DG Set

1

-

-

... More
M&L for Renewal/replacement of Dynamo belts for the following capacity DG sets as per existing size and model complete all as directed by Engr-in-charge. Make :- As per OEM Recommendation Upto 50 KVA DG Set

1

-

-

... More
All as per item No 19 above but above 200 KVA and up to 250 KVA DG Set

1

-

-

... More
M&L disconnecting & removing the unserviceable DC wiring from DG set of any type/any make/any model/any capacity and rewiring with the same with suitable new copper wire to existing gauge wire by providing flexible pipe including making all electrical connections as per OEM recommendation for satisfactory completion of job & checking of electrical/electronic spares working condition and testing etc complete all as specified and directed. Note: (i) The rate quoted deemed to be inclusive of new copper wire cost in the unit rate.

2

-

-

... More
M&L for replacement of existing unserviceable water temperature gauge with new water temperature gauge for the DG set of any description including making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make: OEM recommended make

2

-

-

... More
M&L for replacement of existing unserviceable lubricant oil temperature gauge with new lubricant oil temperature gauge for the DG set of any capacity including making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make: OEM recommended make

2

-

-

... More
M&L for replacement of existing unserviceable oil pressure gauge with new oil pressure gauge for the DG SET of any capacity including making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make: OEM recommended make

2

-

-

... More
M&L for replacement of unserviceable solenoid switch with new solenoid switch 12volts for DG set of any make and any capacity including making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make :- OEM recommended

2

-

-

... More
M&L for replacement of unserviceable solenoid switch with new solenoid switch 24volts for DG set of any make and any capacity including making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make :- OEM recommended

2

-

-

... More
S&F in repairs the following spare parts for any type/make of DG sets, as and when required by the department complete all as specified and directed. Make for item no 26 to 26.10:- OEM recommended

-

-

-

... More
Starting/Ignition - key/button

1

-

-

... More
Volt Meter 0-500V

1

-

-

... More
Amps Meter

1

-

-

... More
Frequency Meter

1

-

-

... More
S.D Valve assembly

1

-

-

... More
Oil safety control

1

-

-

... More
Water safety control

1

-

-

... More
Water separator bowl 3247715

1

-

-

... More
Hour Meter

1

-

-

... More
Radiator Metal Pipes

1

-

-

... More
Supply and filling the new engine oil 20W/40 for toping up upto the required level complete all as directed by Engr-in-charge Make :- CASTROL/ INDIAN OIL/ SERVO

300

-

-

... More
Supply and filling the new engine oil 15W/40 for toping up upto the required level complete all as directed by Engr-in-charge Make :- CASTROL/ INDIAN OIL/ SERVO

100

-

-

... More
S&F in replacement of Line Voltage Monitors (LVMS) of existing make to DG set upto 50 KVA capacity listed parameters including testing complete all as specified and as directed. Make :- OEM recommended

2

-

-

... More
S&F in replacement of Line Voltage Monitors (LVMS) of existing make to DG set capacity up 200 to 250 KVA capacity listed parameters including testing complete all as specified and as directed. Make :- OEM recommended

1

-

-

... More
Drain out the fuel from the fuel tank of DG set of capacity 500 Ltrs and above and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as directed by Engr-in-charge.

3

-

-

... More
S&F in replacement of Rectifiers of existing Make to DG Set of Up to 50 KVA capacity with all listed parameters including testing complete all as specified and directed.

1

-

-

... More
S&F in replacement of Rectifiers of existing Make to DG Set capacity up to 100 to 250 KVA capacity with all listed parameters including testing complete all as specified and directed.

1

-

-

... More
M &L for Removing of defective engine oil control pressure switch supply & fix new engine oil control pressure switch suitable for up to 100KVA DG set complete all as directed by Engr-in-charge. Make as per OEM Recommendation.

1

-

-

... More
M&L for Removing of defective engine oil control pressure switch supply & fix new engine oil control pressure switch suitable for above 100 KVA to 250 KVA DG set complete all as directed by Engr-in-charge. Make as per OEM Recommendation.

1

-

-

... More
M&L disconnecting & removing the unserviceable AC wiring from AMF panel of DG set of any type/any make/any model/any capacity and rewiring with the same with suitable new copper wire to existing gauge wire by providing flexible pipe including making all electrical connections as per OEM recommendation for satisfactory completion of job & replacement of electrical/electronic spares and testing etc complete all as specified and directed. Note: (i) The rate quoted deemed to be inclusive of new copper wire cost in the unit rate. (ii) Electrical/Electronic spares shall be measured & paid separately under relevant items.

3

-

-

... More
Supply only following spare parts :- Push buttons.

6

-

-

... More
AMF Panel Hooter

1

-

-

... More
Earth fault relay. Make: OEM recommended

1

-

-

... More
Over load relay. Make: OEM recommended

1

-

-

... More
Over/Under voltage relay. Make: OEM recommended

1

-

-

... More
Auxiliary relays 12v/6Amps Make: OEM recommended

1

-

-

... More
Power Contactor 4 pole,02 NO +NC,400Amps, Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE

1

-

-

... More
Power Contactor 4 pole,02 NO +NC,250AmpsAmps, Make: L&T/Tc/ABB/SIEMENS/ Schnieder / GE

1

-

-

... More
Power Contactor 4 pole,02 NO +NC,200Amps, Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE

1

-

-

... More
Single phase preventer,make:minilec/GIC

1

-

-

... More
Auxiliary Relays 24Volts / 6A Make: OEM recommended

1

-

-

... More
PLC based AMF relay unit Make: OEM recommended

1

-

-

... More
Low lube oil safety switch Make: OEM recommended

1

-

-

... More
Booster Relay 24Volts / 10A Make: OEM recommended

1

-

-

... More
Battery charger 24 V /10A panel mounting type Make: OEM recommended

1

-

-

... More
Battery charger 12 V /10A panel mounting type Make: OEM recommended

1

-

-

... More
Coolant temperature sensor Make: OEM recommended

1

-

-

... More
Power contactor 4 pole, 02NO+02NC,63 Amps ,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE

1

-

-

... More
Contactor operating coil of Power Contactor 4 pole,02 NO +NC,250AmpsAmps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE

1

-

-

... More
Contactor operating coil of Power Contactor 4 pole,02 NO +NC,200Amps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE

1

-

-

... More
contactor operating coil of Power Contactor 4 pole,02 NO +NC,100Amps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE

1

-

-

... More
contactor operating coil of Power contactor 4 pole, 02NO+02NC,63 Amps, Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE

1

-

-

... More
M&L for Removing the defective charging dynamo of capacity 24 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable to same existing size/gauge & reconnecting the same, refixing back, in original position including making all necessary electrical/mechanical connections testing and commissioning complete all as directed by Engr-in-charge.

1

-

-

... More
M&L for Removing the defective charging dynamo of capacity 12 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable to same existing size/gauge & reconnecting the same, refixing back, in original position including making all necessary electrical/mechanical connections testing and commissioning complete all as directed by Engr-in-charge.

1

-

-

... More
M&L for replacement of unserviceable spares for water manifold and Radiator spares upto 63 KVA DG set for the following spares:- Radiator rubber hoses.

2

-

-

... More
Clamp for hump hose.

8

-

-

... More
Hose clamps.

8

-

-

... More
hump hose.

3

-

-

... More
M&L for replacement of unserviceable spares for water manifold and Radiator spares above 63 and upto 182.5 KVA DG set for the following spares:- Radiator rubber hoses.

2

-

-

... More
Clamp for hump hose.

5

-

-

... More
Hose clamps.

5

-

-

... More
hump hose.

2

-

-

... More
M&L for replacement of unserviceable spares for water manifold and Radiator spares above 182.5 kVA and upto 250 KVA DG set for the following spares:- Radiator rubber hoses.

2

-

-

... More
Clamp for hump hose.

5

-

-

... More
Hose clamps.

5

-

-

... More
hump hose.

2

-

-

... More
M&L for Inhibitor corrosion (coolant additive concentrate) required for top up (TVS Make) complete all as directed by Engr-in-charge.

150

-

-

... More
Supply and topping up of acid mixture suitable for lead acid batteries of 12 volts complete all as directed by Engr-in-charge.

8

-

-

... More
Supply and topping up of distilled water suitable for lead acid batteries of 12 volts complete all as directed by Engr-in-charge.

17

-

-

... More
S&F battery brass terminal and jelly complete all as specified and directed.

20

-

-

... More
M&L for Disconnecting all connection & remove the PT pump from engine and transport to OEM authorised service center and Calibration of PT pump for maximum efficiency by OEM Authorised Service center & replacement of PT Pump kit, gear gasket, etc in its original position by making all necessary connections complete whichever required under AGE E/M-I(U) AOR for smooth functioning of flowing DG Set capacities complete all as directed by Engr-in-charge DG Set capacity up to 30 KVA

1

-

-

... More
DG Set capacity above 50 to 250KVA

1

-

-

... More
M&L for remove the fuel injection pump from the engine transport to an authorized service centre for service, calibration and to adjust by replacing the following un serviceable worn-out spares with new appropriate make minor spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity up to 63 KVA :- Note: Major spares required will be measured and paid separately.

3

-

-

... More
Supply only orfice for up to 63KVA capacity DG set

2

-

-

... More
Supply only Barrel and Plunger for up to 63KVA capacity DG set

2

-

-

... More
Supply only FIP Bearing for up to 63KVA capacity DG set

2

-

-

... More
M&L for remove the fuel injection pump from the engine transport to an authorized service centre for service, calibration and to adjust by replacing the following un serviceable worn-out spares with new appropriate make minor spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity upto 63 KVA :- Note: Major spares required will be measured and paid separately.

2

-

-

... More
Supply only FIP Bearing for above 63 KVA and upto 182.5KVA capacity DG set

2

-

-

... More
M&L for remove the fuel injection pump from the engine transport to an authorized service centre for service, calibration and to adjust by replacing the following unserviceable worn-out spares with new appropriate make minor spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity above 63 KVA and upto 250KVA :- Note: Major spares required will be measured and paid separately.

2

-

-

... More
Supply only orfice for above 63 KVA and upto 250KVA capacity DG set

1

-

-

... More
Supply only Barrel and Plunger for 63 KVA and upto 250KVA capacity DG set

1

-

-

... More
Supply only FIP Bearing for above 63 KVA and upto 250KVA capacity DG set

1

-

-

... More
Supply and fix self starter Motor, 24 volts, Make LUCAS or its equivalent make approved by OEM of DG Set suitable for existing DG set above 50 KVA to 250 KVA including making all necessary electrical/mechanical connection as per recommendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position complete all as directed by Engr-in-charge

1

-

-

... More
Supply and fix self starter Motor, 12 volts, Make LUCAS or its equivalent make approved OEM of DG Set suitable for existing DG set capacity up to 250 KVA including making all necessary electrical/mechanical connection as per recommendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position complete all as directed by Engr-in-charge

1

-

-

... More
M&L for Servicing of DG Set panel's MCCB Breaker indoor/outdoor type of any make/model/capacity, checking of switching ON/OFF & tripping system, checking of all electrical mechanical components of AMF panel and Setting the same for proper working of Breaker, testing of operation manually and auto mode complete all as directed by Engr-in-charge. Note:-All the mechanical parts are thoroughly cleaned by suitable cleaning agent & moving parts are properly lubricated

3

-

-

... More
Supply, install, test, commissioning & run the DG set's Fly-wheel Ring of Fly-wheel Assembly of existing model, size suitable to DG Set of capacity up to 250 KVA including taking down old Unserviceable complete all as directed by Engr-in-Charge.

1

-

-

... More
Disconnect the Radiator and kept aside safely and taking down the old unserviceable water pump from the existing engine of DG set any make/model, capacity up to 250 KVA supply and fixing of new water pump & kit, reassembling the same and refixing the pump to the engine of DG set, refixing Radiator and testing, including making all Electrical/mechanical connections, commissioning as per OEM recommendation complete all as directed by Engr-in-charge.

2

-

-

... More
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model, size suitable to DG Set of capacity up to 250 KVA including taking down old unserviceable complete all as directed by Engr-in-Charge.

1

-

-

... More
Supply, Fix Diesel banjo Hose pipes of 1.0 Meter length with both edges brass clamps of existing model suitable to DG Set of capacity up to 250 KVA including taking down old unserviceable complete all as directed by Engr-in-Charge.

3

-

-

... More
M&L for disconnecting all electrical & mechanical connections, Dismantle the Engine (make KIRLOSKER/ CUMMINS /GREAVES/ GREAVES COTTON/ASIATIC/ RUSTON) from 50 KVA to 250 KVA DG set capacities located at various location under AGE E/M-I(U) and transported to OEM Authorised service center for complete overhauling, replacing the following unserviceable worn-out spares with new appropriate make minor spares & major spares (minor spares- up to Rs 2500/Each), after assembling the spares the Engine again shifted to original existing place and reassembled to alternator& radiator,AMF panel/Electrical panel board of DG set complete testing, commissioning all as per OEM recomendation and as directed by Engr-in-charge.The quoted rate inclusive of Manpower, Crane charges for transporting engine to wokshop and back after repairs Note: - (i)Major Spare parts shall be measured and paid separately.

1

-

-

... More
Gear fuel Pump

1

-

-

... More
Total Gakets Set

1

-

-

... More
Core & cooler set

1

-

-

... More
Shaft rocker arm

2

-

-

... More
Oil seal

1

-

-

... More
Ball Bearings set

2

-

-

... More
Main Bearings set(STD)

1

-

-

... More
Material and labour for repairs to Alternator of following DG Set, transporting the same to the OEM authorised service center/work shop and carrying out the repairs such as taking out the burnt out winding and rewinding the alternator with copper wire of same guage turns and weight, checking of commentator, brushes complete and refixing the same in its existing position after transporting back to the site and connecting up electric connections with suitable lugs complete and testing all as specified and directed. Note: Copper winding material will be measured and paid seperately under relevant Item

-

-

-

... More
Upto 50 KVA capacity

1

-

-

... More
Above 50 KVA and upto 250 KVA Capacity

1

-

-

... More
Supply only High conductivity copper conductor winding material including necessary insulation material as required for complete all as specified and directed by Engr-in-Chrage

40

-

-

... More
M&L taking down defective Turbo Charger Assembly duly disconnecting the mechanical and electrical connections from DG Set, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit and spares as required at site including any mechanical and reassembling and refixing the turbo charger assembly to its original position and reconnecting the same for the following capacities including testing complete all as specified and directed.

-

-

-

... More
DG Set of capacity above up to 250 KVA

1

-

-

... More
M&L for calibration of water pump complete, overhauling, replacing of gaskets, nuts, washers etc and reassembling the same and refixing the pump to the engine and testing including taking down the old unservicable water pump of any capacity of DG set from the engine and taking it out side work to workshop, complete all as specified and directed:-

-

-

-

... More
DG Set of capacity 10 KVA To 50 KVA

3

-

-

... More
DG Set of capacity above 182.5 KVA and up to 250 KVA

1

-

-

... More
M & L for dismantling & disconnecting all connection of the cylinder heads from diesel engine and sent to OEM authorised Service center for calibration and repairs by replacing the spares such as Valves, Valve Guides, Valves seats and repairs kit and re-assembling to its original position with necessary Engine cylinder head gasket and O rings for the following capacities including testing complete all as specified and directed:-

-

-

-

... More
DG Set of capacity 7.5 KVA To 30 KVA

2

-

-

... More
DG Set of capacity above 50 KVA and up to 250 KVA

1

-

-

... More
M&L preparation of old painted surfaces of the DG Sets of the 7.5 KVA to 25 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.

2

-

-

... More
M&L preparation of old painted surfaces of the DG Sets of the above 25 KVA and up to 50 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.

1

-

-

... More
M&L preparation of old painted surfaces of the DG Sets of the above 200 KVA and up to 250 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.

1

-

-

... More
M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note:- Item of earthing includes cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.

4

-

-

... More
S&F in replacement of microprocessor based control unit suitable to DG set of 200 KVA to 250 KVA capacity with all listed parameters as per recomendation including testing complete all as specified and directed.

2

-

-

... More
M&L on load change over switch 400 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,font handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T/Standard/HPL

1

-

-

... More
M&L on load change over switch 200 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,font handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T/Standard/HPL

1

-

-

... More
Supply and connect LT 1100 V outdoor type cable straight through heat shrinkable epoxy joint kit suitable for the following sizes with necessary jointing materials complete all as directed by Engr-in-charge. Make :- M-SEAL/ DENSON/3-M/ RAYCHEM 3.5 core x 25/35 sqmm.

3

-

-

... More
All as per item No 72 above but 3.5 core x 70/95 sqmm.

3

-

-

... More
All as per item No 72 above but 3.5 core x 120/150 sqmm.

2

-

-

... More
S&F Weather proof outdoor bus bar chamber, made out of 3 mm thick MS sheet duly powder quoted comprising 4 Nos aluminium strips each of 200Amps, 60cm long duly insulated mounted on insulators including MCCB 200 Amp with 4 Nos mounting legs made out of 25mm x 25mm x 6mm angle iron grouted in PCC block of size 30cm x 30cm x 90cm (30cm depth below ground level and 60cm above ground level) in cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregate), and connections with suitable size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils, including taking out old unserviceable bus bar chamber complete all as specified and directed. Make: Havells/L&T/Standard

3

-

-

... More
All as per item No 73 above but incomer 250Amps MCCB.

3

-

-

... More
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 400Amps, 50kA, 415volts,50 Hz with adjustable settings & thermal,magnetic realse,suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.

2

-

-

... More
Supply&Fixing of 3 pole MCB,32-63amps,C-curve,10kA,50Hz,440v in existing panel including necessary wiring & misc accessroies for satisfactory completion of job and taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens

15

-

-

... More
Supply,test,laying & commissioning of XLPE insulated, armoured (heavy duty) electric cable with aluminium stranded conductor, 1100 volts grade, laid in trenches / duct/ fixed to wall with suitable size clamps / passing through pipe/Tunnel/under ground/surface up to the termination point(as directed by Engr-in-Charge) with necessary end terminations with suitable size cable lugs, cable glands, fixing of lugs with crimping with tool,nuts,boltsetc of the following sizes and including taking out unserviceable burnt out cable from its existing location complete all as specified and directed by Engr-in-Charge :-

-

-

-

... More
3.5 Core X 35 Sqmm

200

-

-

... More
3.5 Core X 50 Sqmm

200

-

-

... More
3.5 Core X 70 Sqmm

200

-

-

... More
3.5 Core X 95 Sqmm

124

-

-

... More
3.5 Core X 185 Sqmm

50

-

-

... More
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation, laying of poles in trenches and getting out in Hard soil complete all as specified and as directed Engineer-in-Charge.

497

-

-

... More
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as directed by Engineer-in-Charge.

410

-

-

... More
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtrs above from the starting point complete all as directed by Engineer-in-charge.

87

-

-

... More
Supply and spread approved dry river sand for foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as directed by Engr-in-Charge Note:- Punned thickness will be measured for payment purpose

50

-

-

... More
Supply and Lay bricks common burnt clay building bricks sub class B of size 230 x 115 x 75 mm complete all as specified and directed.

3993

-

-

... More
M & L Galvanised iron tubing 80 mm dia light grade laind in trenches/floors/walls for eath lead protection and cables at road crossing etc complete all as specified and directed.

20

-

-

... More
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.

12

-

-

... More
Supply&Fixing of 200/5 Amps Current transformers -03Nos(in three phases) including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.

1

-

-

... More
S&F twin core 2.5 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed. Make - Finolex/Havells/Standard /Finecab.

200

-

-

... More
S&F twin core 4 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed. Make - Finolex/Havells/Standard /Finecab.

500

-

-

... More
S&F twin core 6 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed . Make - Finolex/Havells/Standard /Finecab.

500

-

-

... More
S&F twin core 10 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed. Make - Finolex/Havells/Standard /Finecab.

300

-

-

... More
Material and labour for Batery charger, maintenance free, used to charge batteries rating 30 Ah to 360 Ah , comprises 4 MCB for online charging of Batteries and necessary fixing arrangement as per the site requirement complete all as specified and as directed

3

-

-

... More
Supply and Replacement of Solar Glass of 100 to 125LPD suitable for existing panel of solar water heaters complete all as specified and directed.

2

-

-

... More
Supply and Replacement of Solar Glass of 200 to 300 LPD suitable for existing panel of solar water heaters complete all as specified and directed.

10

-

-

... More
Supply and Replacement of Solar main heating Tank of capacity 200 to 300 LPD suitable for existing Tank complete all as specified and directed.

10

-

-

... More
M&L for Servicing of Solar water Heater 200 to 300 LPD HHC System including changing of gasket, minor spares part as per requirement on site complete all as specified and directed

60

-

-

... More
M&L for Servicing of Solar water Heater 100 to 125 LPD HHC System including changing of gasket, minor spares part as per requirement on site complete all as specified and directed

5

-

-

... More
Supply and fix in repairs of GI Pipe medium grade of 20mm dia with all fittings such as union, elbows tee , bend etc laid on wall/ ceiling complete all as specified and directed

200

-

-

... More
Supply and fix in repairs of GI Pipe medium grade of 25 mm dia with all fittings such as union, elbows tee , bend etc laid on wall/ ceiling complete all as specified and directed

200

-

-

... More
Supply and fix in repairs of of GI pipe medium grade of 15mm dia with all fittings such as union, elbows tee , bend etc laid on wall/ ceiling complete all as specified and directed

200

-

-

... More
Supply and fix in repairs of gun metal , globe or gate valve of 15 mm dia with iron wheel head screwed both ends for iron pipe and fix on wall/ground

10

-

-

... More
Supply and fix in repairs of gun metal , globe or gate valve of 20 mm dia with iron wheel head screwed both ends for iron pipe and fix on wall/ground

20

-

-

... More
Supply and fix in repairs of gun metal , globe or gate valve of 25 mm dia with iron wheel head screwed both ends for iron pipe and fix on wall/ground

20

-

-

... More
M&L for Chemical washing of collector and storage tank by using Hydro chlorine chemical oil (with in three to four month) all as per site requirement and directed by Engineer in Charge.

65

-

-

... More
M & L for Cleaning of panel glass with soap oil (within three to four months) as per site requirement

65

-

-

... More
Removing unserviceable and refixing the new one sacrifical anode as per site requirement complete all as specified and directed

50

-

-

... More
Removing unserviceable and thermosate fixing the new as per site requirement complete all as specified and directed

5

-

-

... More
Removing unserviceable and refixing the new one heating elements suitable for existing make and size single phase 2kw, 230 V complete all as specified and directed

5

-

-

... More
Removing unserviceable and refixing the new one Air Wind values for presser suitable for existing system complete all as specified and directed

20

-

-

... More
M&L for checking the inlet and outlet piping, fixing GI pipes , value , flange joints up to bib cocks and arresting the leakage if any , recording the temperate of the hot water and servicing overall system complete all as specified and directed

50

-

-

... More
S&F MCCB 250 Amps, 4 pole, 415 Volts with rapturing capacity 36KA with adjustable magnetic and adjustable thermal settings as in repairs complete all as specified and directed.

3

-

-

... More
S&F MCCB 400 Amps, 4 pole, 415 Volts with rapturing capacity 36 KA with adjustable magnetic and adjustable thermal settings as in repairs complete all as specified and directed.

1

-

-

... More
S&F MCCB 63Amps, 4 pole, 415 Volts with rapturing capacity 25 KA with adjustable magnetic and adjustable thermal settings as in repairs complete all as specified and directed.

2

-

-

... More
S&F MCCB 160 Amps, 4 pole, 415 Volts with rapturing capacity 25 KA with adjustable magnetic and adjustable thermal settings as in repairs complete all as specified and directed. Make:- Havells/L&S /IndoAsian/Shcieder/Standard.

2

-

-

... More
S&F MCCB 100 Amps, 4 pole, 415 Volts with rapturing capacity 25 KA with adjustable magnetic and adjustable thermal settings as in repairs complete all as specified and directed. Make:- Havells/L&S /IndoAsian/Shcieder/Standard.

2

-

-

... More
S&F conneting and testing MCB isolator three pole and neutral 440 volts of capacity 40 A 16 KA 50 'C" curve complete

2

-

-

... More
Supply and lay PVC Insulated , PVC sheathed industrial HV round multicore flexible cable with copper conductor 3 core 2.5 sqmm including PVC conduit 20 mm dia medium grade and necessary bends, fittings and fixtures as required for connection of light fittings . Note : Used for garden light connection, excavation, retuning filling etc will be measured and paid separately.

200

-

-

... More
Supply and fixing in repair Rotational moulded polyethylene water storage tanks 500ltrs (cylindrical vertical with closed top) hoisted and fixed in position and fixed in position all as specified in SSR part I Notes for 1 to 115 items :- (a) Daily Collecting of complaints from JE/AGE is responsiblity of Contractor. After collecting Complaints from Complaint Register or Insturction by JE by Phone/SMS, complaint should be completed within 48 Hours of complaint receiving, Major complaints/AMF panel wiring/Rewinding etc items should be completed within 05 days, (b) Minimum 01 Technician with all tools, ladder and testing Equipment, as per the site requirement shall be provided by contractor. (c) Every month complete testing for serviceablity of DG Set for all Generator shall be done and reports submitted to Engr- in -Chage at the end of every month (if items required shall be paid under relevant items given above). (d) Documents required for complaints like Stationery, Complaint Register, Slips & Site Order Book shall be provided by the contactor.(e) safety precautions shall be responsible by the contractor. (f) Contractor to comply all the respective notes of Particular Specifications attached.

2

-

-

... More
STP : Supply, Install, Testing and Commissioning of Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m. The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM). The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. The earting pit cover should be factorty built (size TOP- 10 Inch, Bottom -13 Inch, Height 10.25 Inch ) made of heavy duty Polypropylene complete all as specified and directed. Make: ASHLOK/INDELEC/JMV/TERCEL/TRUE POWER

2

-

-

... More
M&L for removal sludge and complete cleaning of all sludge tank pertaining to 100 KLD STP functioning at 68 Med regt and sending sludge to Faecal Sludge Treatment Plant (FSTP) complete all as specified and directed. Note: Contractor should visit the site to understand site condition as well as the condition of 68 Med Regt before coating the rates. No claim in this regard will be entertained during execution stage.

1

-

-

... More
S&F in replacement Transceiver automation for the water level Detector and controller with the feature mentioned here under:- 1. S& F Transceiver must communicate at a distance of 3km -5kms range with each module must have the LORA/GSM or suitable communication module ( long range antenna) must work above 500 MHz and each module shall have a processor module connecting to the sensor, with the facility that the processor module to sense the low level (10-20%) and high level of the water level (90-100%) so as to raise the hooter and communicate with the other hardware modules with antennas. S&F transducer module wiring through the D sub connectors (MIL industrial grade are to be used). All the wiring must be shielded optical co-axial cable for connection to flasher and hooter. Rates quoted are deemed to be included for suitable flasher and hooter. S&F Hooter 12V/5 Amp with suitable converter or hooter suitable for 230V AC Supply must be provided standard suspended rust proof stand Note: All the NPT cable glands must be used for the sensor interface and MCB controller board. S&F 12V flasher with suitable converter or flasher suitable for 230V AC Supply connected with suitable 3 Core Co axial cable suitably crimped nicomatic connector. Note: All the cables to be drawn through suitable medium grade conduit suitably fixed with clamps. S &F of LED display board with superior night vision display to be provided at the receiver station. S&F controller Board confirming to IP 65 protection 3D printed with EMI/EMC compatible FE 32 material for the enclosure. All the 3D/CAD models must be provided for review before the enclosure are fitted with AUTO CAD/PRO drawings shall be provided. Note: One transmitter for over Head Tank and one receiver for Pump House and complete system shall be warranted with 24 hrs rectification for any non functioning for a period of 1 year replacement warranty.

1

-

-

... More
Supply and replace Bar Screen of 100 KLD STP made out of SS 304 stinless steel solid bar bucket type complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
M&L for removal of sewage and garbage from MBBR tank and painting inside and outside with one coat of red oxide and two coat of sysnthetic enamael paint and cleaning of fiver setting plated of MBBR tank complete all as specified and directed by Engr-in-Charge

1

-

-

... More
Material and labour for MBBR fludised bio-media of vergin PPUV stablized material,cylindrical with external fins structure,black colour,22mm dia x 16mm height ,specific gravity 0.9 to 0.95 gms/sqcm all as specififed and as directed . Make: TP Aqua/Cool tech/Hydrotech as approved

1

-

-

... More
Material and labour Bactria culture for STP for developing MLSS and control odor complete all as directed by Engr-in-Charge. Make: Organic plus or its techno commercial equivalent make aproved by GE.

20

-

-

... More
M&L for rewinding of the electric motor of above 5Hp upto 7.5 HP capacity duly disconnecting (elctric/water connection) and taking down electric motor (mono block/centrifugal) from the existing position and inspecting the same, transporting to workshop for repairs and bringing it back. Cutting and removing the burnt out winding conductors, rewinding the same with same gauge and weight of insulated super enamelled copper conductor and providing cotton insulated sleeves, varnishing, drying, refixing in position checking the alignment along with pump set connecting up with the electrical and water line connection system, testing and commissioning complete all as directed.

1

-

-

... More
M&L for rewinding of the electric motor of upto 5 HP capacity duly disconnecting (elctric/water connection) and taking down electric motor (mono block/centrifugal) from the existing position and inspecting the same, transporting to workshop for repairs and bringing it back. Cutting and removing the burnt out winding conductors, rewinding the same with same gauge and weight of insulated super enamelled copper conductor and providing cotton insulated sleeves, varnishing, drying, refixing in position checking the alignment along with pump set connecting up with the electrical and water line connection system, testing and commissioning complete all as directed.

1

-

-

... More
Opeining of the unserviceable bearing from the centrifugal pump set replacing the same with the new bearing set sutiable for motor/ pump set 7.5HP capacity including re-aliging the pump and motor complete all as directed.

1

-

-

... More
Opeining of the unserviceable bearing from the centrifugal pump set renewing the same with the new bearing set sutiable for motor/ pump set 1/2/3/5hp capacity including re-aliging the pump and motor complete all as directed.

1

-

-

... More
Supplying of 'Aquafit' Brand calcium hypochloride 65-70% chlorine content in granular form to mix with drinking water which is received at Pump house for purifing the water & mainaining its PPM, complete all as specified and directed. Make: Sree rayalama Hi-Strength Hypo ltd or Equivalent.

315

-

-

... More
Repairs to sewage pump including replacing the impeller upto 5 HP mud pump Kirloskar and unserviceable parts viz bushes, gland cover with nut bolts gland rope etc complete all as directed by Engr-in-Charge.

2

-

-

... More
Repairs to sewage pump including replacing the impeller above 5 upto 7.5 HP mud pump Kirloskar and unserviceable parts viz bushes, gland cover with nut bolts gland rope etc complete all as directed by Engr-in-Charge.

1

-

-

... More
Reconditioning of shaft by metal filling and machining as required and replacement of shaft sleeves with new one of capacity rating up to 5 hp pump set Note :- Without causing any interruption of regular water supply and complete all as directed by Engineer-in-Charge.

1

-

-

... More
Reconditioning of shaft by metal filling and machining as required and replacement of shaft sleeves with new one of capacity above 5hp up to 7.5hp pump set Note :- Without causing any interruption of regular water supply and complete all as directed by Engineer-in-Charge.

1

-

-

... More
Repairs/replacent of wornout spares of Air blower 3-ph,415volts,50hz of capacity 130cum/hr @0.4KSC,twin loop type including suction filter,motor pully & replacement of unservceable spares such as 'V' belt,bearings, shaft,suction filter,motor pulley & blower motor oil with new one including all nessary misc items for satisafactory completion of job complete all as Specififed & directed by Engr-in-Charge

2

-

-

... More
M&L cleaning the all and any type of tanks pertains to sewage treatment plant 100KLD of receiving sump(collection tank) with suiatble chemeicals, drying the tanks and disposal of Dry sludge minmum distance of 1km raduis from STP location & maintain high level hygiene in STP permises complete all as specified and as directed by Engr-in-Charge. Note: (i) For disposal of dry sludge contactor shall make arrange transport sysytem quoted rate shall be inclusive in unit rate.

1

-

-

... More
S&F in repairs CI foot valve leather sheet type / flange type suitable for 80 mm dia GI suction heavy duty includung replacement of nuts, bolts washers, gaskets and flanges etc. complete all as directed and specified by Engr-in-charge.

2

-

-

... More
S&F in repairs CI foot valve leather sheet type / flange type suitable for 50 mm dia GI suction heavy duty includung replacement of nuts, bolts washers, gaskets and flanges etc. complete all as directed and specified by Engr-in-charge.

2

-

-

... More
S&F in repairs PVC foot valve leather sheet type / flange type suitable for 50 mm dia GI suction heavy duty includung replacement of nuts, bolts washers, gaskets and flanges etc. complete all as directed and specified by Engr-in-charge.

1

-

-

... More
Supply, lay and fixing steel water tubes, medium grade, galvanised with all fitting laid in trenches as in repairs complete all as specified and directed for following bore of pipes :- (a) 25 mm bore.

250

-

-

... More
40 mm bore.

175

-

-

... More
50 mm bore.

120

-

-

... More
Supply, lay and fixing gun metal gate valves, ISI marked connected with iron wheel head, screwed at both ends for iron pipes and fixed including taking down of unserviceable gate valve complete all as specified and directed for following bore of pipes :- (a) 25 mm bore.

10

-

-

... More
40 mm bore.

5

-

-

... More
50 mm bore.

5

-

-

... More
Supply and laying of 3-layer PP-R Polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV Stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches etc all as specified and directed of following bores. :- (a) 25 mm bore.

380

-

-

... More
50 mm bore.

600

-

-

... More
Supply and fix 25 mm PP-R Gate valves ( brass insert) as per requirement of the site complete all as specified and directed

4

-

-

... More
Supply and fix 50 mm PP-R Gate valves ( brass insert) as per requirement of the site complete all as specified and directed

4

-

-

... More
M&L for servicing and over hauling of 3 HP Open well submersible pump set including varnishing the stator and replacing the worn out drive end/driven end bearings, greasing, reassembling and testing complete all as directed

1

-

-

... More
M&L for rewinding of the electric motor of above upto 3 HP capacity duly disconnecting (elctric/water connection) and taking down electric motor (open well submersible) from the existing position and inspecting the same, transporting to workshop for repairs and bringing it back. Cutting and removing the burnt out winding conductors, rewinding the same with same gauge and weight of insulated super enamelled copper conductor and providing cotton insulated sleeves, varnishing, drying, refixing in position checking the alignment along with pump set connecting up with the electrical and water line connection system, testing and commissioning complete all as directed.

1

-

-

... More
M&L for servicing and over hauling of 5/7.5 HP Open well submersible pump set including varnishing the stator and replacing the worn out drive end/driven end bearings, greasing, reassembling and testing complete all as directed

1

-

-

... More
M&L for rewinding of the electric motor of above 5Hp upto 7.5 HP capacity duly disconnecting (elctric/water connection) and taking down electric motor (open well submersible) from the existing position and inspecting the same, transporting to workshop for repairs and bringing it back. Cutting and removing the burnt out winding conductors, rewinding the same with same gauge and weight of insulated super enamelled copper conductor and providing cotton insulated sleeves, varnishing, drying, refixing in position checking the alignment along with pump set connecting up with the electrical and water line connection system, testing and commissioning complete all as directed.

1

-

-

... More
M&L for servicing and over hauling of 3/5 HP Induction motor pump set including varnishing the stator and replacing the worn out drive end/driven end bearings, greasing, reassembling and testing complete all as directed

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.