Military Engineer Services Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Sep 2024
Closing Date3 Oct 2024
Tender Amount₹ 47,98,000
Costs
EMD
₹ 95,960Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_674036_1Bid Award Id
ViewTender No
8990Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://MilitaryEngineerServices
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(xi) Support provided by OEM : pre supply and inspection, installation feasibility study at site, Health check-up of existing DG, Type Approved RECD with complete Solution, Educating Dept Staff on usage and operation and maintenance procedure (xii) Installation and commisssioning of RECD by authorised and approved OEM only Scope of Work : (i) Emission control system with PRV , Inlet & outlet pipe, Structure with removable ladder and Electri panel with all accessories. (ii) Performance / Characteristic curves at rated load - Under vendor scope (iii) The output result of RECD shall be as per CPCB -II norms, irrespective of the manufacturer;s technology (vi) Secondary emission : Bidder shall submit the declaration that there is no secondary emission (V) Noise emission : No increase in noise level after installation of retrofit device (vi) No by-pass arrangement in RECD allowed to let the pollutants in open environment (vii) Testing -Genset shall be tested on all load pattern available at site during post RECD installation (viii) Warranty in all respect of 02 years post completion of work is applicable in RECD installation (ix) Contractor shall furnish manufacturer's written instruction and requirement about use and maintenance of RECD system, its operation and maintenance schedule.
-
-
-
Notes :- (i) Retro -fit emission contrrol system should be as per Statutory Authorities recommendations to achive minimum specified particulate matter capturing efficiency of at least 70% The emission control system shall be type tested and approved from CPCB approved laboratories as per guideline of NGT and MOHUA(MINISTRY OF HOUSING AND URBAN AFFAIRS) (ii) Retro-fit emission control system of suitable rating or sizes shall be installed or retrofitted in existing exhaust pipe with required modifications and suitable design compatible for respective model of diesel engine prime mover of DG sets and have safty precautions to ensure no danger to the engine operations under any circumstances (iii) Safety system provided to engine from higher back pressure, engine vibration, and high temperature operations to aviod any malfunction, it should be within the limits as recommended by DG OEM. The retrofit system manufacturer to coordibate and submit certificate from DG OEM. Cost for the same is deemed to be included in the quoted cost.
-
-
-
(iv) The emission reduction will be verfied after the installation of unit at site by any of the air pollution labs approved by CPCB. Contractor will submit the necessary certificate. Cost for the same is deemed to be included in the quoted cost.(v) The unit quoted cost includes all necessery RCC civil foundation/MS structure for installation of RECD structures as per recommendation of manufacturer and as directed by GE. (vi) Make of existing DG set -kirloskar Oiil Engine Ltd/Greaves.
(vii) All RECD equipments of make and model numbers with technical specification along with detail drawing and test certificate shall be submitted to GE by the contractor before procurement of the equipemnt.
(viii) The OEM should install the RECD system in the presence of representative detailed by AO and necessary test certificate shall be obtained as per CPCB norms.
-
-
-
80 KW (100KVA) DG Set
3
-
-
100 KW (125KVA) DG Set
1
-
-
Dismantaling and taking down old existing exhaust system in various capacity of DG Sets complete all as specified and directed by engineer in charge
4
-
-
S&F in 3 pole power contactor type of MNX 300 including taking down old unserviceable one complete all as specified and as directed. MAKE: L&T Catpart No. CS90280/C&S
1
-
-
S&F in 3 pole power contactor type of MNX 50 including taking down old unserviceable one complete all as specified and as directed. MAKE: L&T Catpart No. CS97075/C&S
1
-
-
S&F 3 pole power contactor type MNX 250 including taking out old unserviceable one complete all as specified and as directed. MAKE: L&T Catpart No. CS94141/C&S
1
-
-
S&F 3 pole power contactor type of 265A including taking out old unserviceable one complete all as specified and as directed. MAKE: Schnider Catpart No. LC1F265/L&T
1
-
-
S&F On- load changeover switch in Sheet metel enclosure with front handle operating system, powder coated, factory made of capacity 200 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed.
1
-
-
S&F On- load changeover switch in open execution with front handle operating system, powder coated, factory made of capacity 250 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed.
1
-
-
S&F On- load changeover switch in Sheet metel enclosure with front handle operating system, powder coated, factory made of capacity 400 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed.
1
-
-
S&F On- load changeover switch in open execution with front handle operating system, powder coated, factory made of capacity 630 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed.
1
-
-
S&F On- load changeover switch in Sheet metel enclosure with front handle operating system, powder coated, factory made of capacity 630 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed.
1
-
-
S&F On- load changeover switch in open execution with front handle operating system, powder coated, factory made of capacity 800 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed.
1
-
-
S&F On- load changeover switch in Sheet metel enclosure with front handle operating system, powder coated, factory made of capacity 800 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed.
1
-
-
S&F On- load changeover switch in Sheet metel enclosure with front handle operating system, powder coated, factory made of capacity 1000 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed.
1
-
-
S&F On- load changeover switch in Sheet metel enclosure with front handle operating system, powder coated, factory made of capacity 1250 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed.
1
-
-
S&F On- load changeover switch in Sheet metel enclosure with front handle operating system, powder coated, factory made of capacity 1600 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed.
1
-
-
S&F in repair, ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 800 Amps complete all as specified.
1
-
-
S&F in repair, ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 1000 Amps complete all as specified.
1
-
-
S&F in repair, ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 1250 Amps complete all as specified.
1
-
-
S&F in repair, ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 1600 Amps complete all as specified.
1
-
-
S&F in repair, ACB 4 Pole, 415 V, Electronic Drawout type with microprocessor release of capacity 2000 Amps complete all as specified.
Make for item No 7 to 21 : L&T/Havells/ C&S/LEGRAND
1
-
-
Supplying, laying, jointing, testing and commissioning 1100 volts grade, 400 Sqmm 3.5 core LT XLPE insulated, PVC sheathed as per IS-7098 (Part-I), 1988 galvanized steel strip or wire armoured, heavy duty, electric cables, with multistranded aluminium conductor laid in trenches/ passing through pipe/duct/road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., including taking down unserviceable cable complete all as specified and directed.
Note : Earthwork Excavation, sand cushioning GI pipe and cable protection will be measured and paid separately.
100
-
-
All as per item No. 22 above 3.5 core 300 Sqmm
100
-
-
All as per item No. 22 above 3.5 core 240 Sqmm
100
-
-
All as per item No. 22 above 3.5 core 185 Sqmm
100
-
-
All as per item No. 22 above 3.5 core 150 Sqmm
100
-
-
Supply, install, testing and commissioning of AMF Panel for 320 KVA DG Set outdoor type, cubical body, dust and vermin proof made up of CRCA sheet 3 mm thick painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers and mounted on floor with PCC pedastal pillars with a clearence of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories :- (i) PLC - 01 No (ii) Power Contactor heavy duty suitable for 320KVA generator and mains (iii) Over load relay for genset (iv) Suitable rating isolating switch MCCB for both DG & main supply. (v) Multi functioning meter to indicate voltage, current, frequency, PF, KW & KWH etc (vi) Emergency stop push button. (vii) Set of indicaters :- (a) Low lube oil pressure (b) DG Set over load (viii) Push button to start, stop (ix) Mode selector switch i.e Auto/Manual/Test/ OFF. (x) Set of Insrtument fuse (xi) Set of aluminium bus bar of 500 Amps capacity 3 ph, 4 Wire syetem
1
-
-
Supply, install, testing and commissioning of AMF Panel for 500 KVA DG Set outdoor type, cubical body, dust and vermin proof made up of CRCA sheet 3 mm thick painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers and mounted on floor with PCC pedastal pillars with a clearence of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories :- (i) PLC - 01 No (ii) Power Contactor suitable for generator and main (iii) Over load relay for genset (iv) Suitable rating isolating switch ACB 4 POLE for both DG & main supply (v) Multi functioning meter to indicate voltage, current, frequency, PF, KW & KWH etc (vi) Emergency stop push button. (vii) Set of indicaters :- (a) Low lube oil pressure (b) DG Set over load (viii) Push button to start, stop (ix) Mode selector switch i.e Auto/Manual/Test/ OFF. (x) Set of Insrtument fuse (xi) Set of aluminium bus bar of 800 Amps capacity 3 ph, 4 Wire syetem
1
-
-