Military Engineer Services Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_673803_1Bid Award Id
ViewTender No
GE(S)/SEC/TOKEN-53 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of Capacity 1000 litres including PTMT ball valvehigh pressure of 20mm complete all as specified and directed.
20
-
-
S&F in repairs Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 20 mm bore and complete all as specified and directed.
24
-
-
S&F in repairs Ball valve, high pressure with PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or fixed of size 20 mm bore complete all as specified and directed. (Min Wt 20mm- 210 gms)
40
-
-
Demolition and breaking up drain AC pipes/PVC pipe set in cement mortar of any size complete all as specified and as directed.
100
-
-
S&F PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed to walls bore of the pipe 110mm complete all as specified and as directed.
50
-
-
S&F PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed to walls bore of the pipe 75mm complete all as specified and as directed.
50
-
-
S&F PVC (SWR) bends 110mm complete all as specified and as directed.
10
-
-
S&F PVC (SWR) bends 75mm complete all as specified and as directed.
8
-
-
Demolition of cement concrete of any description and in any position not otherewise specifically provided for as in roof etc complete all as specified and as directed.
80
-
-
Taking down existing water proofing treatment with tarfelt including cement plaster from roof including parapets etc, and removing the debris to a distance not exceeding 250m complete all as specified and directed.
400
-
-
M&L for 40mm thick plain cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in padding (level course) on roof incl finishing the cement concrete surfaces even & smooth without using extra cement complete all as specified and as directed.
1500
-
-
M&L for rendering 10 mm thick in CM (1:3) using water proofing compound @ 2 % of the total weight of cement or as per manufacturer instruction as in roof and chajjas finishingcement concrete surface even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately under relevant items.
1900
-
-
M &L for priming plastered roof surfaces (Non approachable roof ) with bituminous primer @ 0.3 Kg/Sqm as per IS 3384 and providing water proofing treatment by applying 3.5 Kg/Sqm ATACTIC polypropylene (Advanced APP torch on membrane mineral finish) having polyester film reinforcement stabilized with fibre glass and finished on top with grey mineral slabs torch on system of thickness 3 mm by torch bonding complete all as specified and as directed.
1900
-
-
M&L for water proofing treatment with APP based standard membrane over PCC padding in approachable roof with the following courses of treatment : (a) Apply bituminous primer (IS3384) @ 0.30 Kg/Sqm of the surface area including cleaning the surface complete all as specified . (b) Apply APP plastomeric bitumen based water proofing membrane polyster reinforced (3.50 Kg/Sqm) with 10 cm overlaps and torch bonded at joints including surface preparation before and after application of treatment as per manufacturers instruction complete all as specified and directed.
100
-
-
M&L for providing 40 mm thick PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) in approachable roof mixed with polyster fibre as per manufacturer instruction and finish the top surface of concrete even and smooth without using extra cement complete all as specified and as directed. (Note : Polyster fibre shall be measured and paid seperately under relevant item).
100
-
-
Supply only Polyster Fibre . Make (RECRON 3S or equivalent) complete all as specified and as directed.
5
-
-
M&L for forming construction (Dummy) joints 10 mm deep and 6 mm wide, filled with sealing compound Grade 'A' complete all as specified and as directed.
30
-
-
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
30
-
-
M&L for uprooting of wild trees such as grass/bushes etc from the roof / wall surfaces / AC sheets/soil pipes surrounding including its penetrated roots with suitable cleaning chemical and making good to the damaged plaster by providing CM 1:3 and finish the surfaces to match with the existing surface complete all as specified and as directed.
30
-
-
M&L for crack filling with approved crack filler to arrest seepage and running water through masonry/RCC surfaces etc. complete all as specified and as directed. Make : Dr.Fixit Leak Plug or its equivalent.
50
-
-
M&L for preparation of plastered surfaces and applying two coats of water proof coating (Dr. Fixit Rain Coat exterior waterproof coating) over a coat of primer (Dr. Fixit Prime seal diluted with potable water by volume in 2:1 ratio, 2 parts primer and 01 part water) including filling of cracks upto 5 mm width, with Dr. Fixit Crack-X, or Dr. Fixit unifiller on external surfaces of wall to arrest the seepage / dampness and running water in the masonry surfaces complete all as specified and as directed. Make : Dr. Fixit or its equivalent.
1200
-
-
Dismantling of Asbestos cement (corrugated, semicorrugated and Transulent sheet etc) sheets in roof covering incl ridges complete all as specified and directed.
1210
-
-
Dismantling timber scantling 40 sq cm and over in any position complete all as specified and directed.
3
-
-
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
4
-
-
M&L for Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
1060
-
-
S&F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strengh of 550 mpa as on roof covering/ridges fixed with self tapping screws complete all as specified and directed.
150
-
-
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates Grade Fe 410 -W (Gde E- 250) quality A complete all as specified and as directed.
4500
-
-
Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets complete all as specified and as directed. .
380
-
-
M&L for providing false ceiling with anodised aluminium snap grid frame work with size of grid 605 x 605 mm with aluminium main tee size 25 x25 x1.60mm thick and, cross T section of size 25 x 25 x 1.60mm thick and wall angle of size 25x25x2mm thick fixed to roof with rawl plugs/GI wire suspenders complete all as specified and directed.
380
-
-
M&L for 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework in ceiling with screws and preparing surface and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
380
-
-
S&F in repairs of CPVC pipes 20 mm dia SDR 11 & plain CPVC SDR 11 fittings in wall /ceiling or laying in floors taking down old GI tubes complete all as specified and directed.
200
-
-
S&F in repairs of CPVC pipes 25 mm dia SDR 11 & plain CPVC SDR 11 fittings in wall /ceiling or laying in floors taking down old GI tubes complete all as specified and directed.
50
-
-
M&L for plain cement concrete type B1, (using 20 mm graded crushed stone aggregate) as in coping, tank stagging and similar works etc complete all as specified and directed.
3
-
-
Disconnecting existing tanks setting aside (or lowering if required) for repairs, cleaning with detergent/detergent powder etc. reconnecting and re-fixing in position including cleaning and removing all scale dirt etc. from tanks and from mouth of circulating pipes etc. and writing the date of cleaning of tank and due date for cleaning of tank , capacity of tanks exc. 500 liters and not exc. 1000 liters complete all as specified and as directed (Note: Each tank will be shifted twice)
10
-
-
Disconnecting existing tanks setting aside (or lowering if required) for repairs, cleaning with detergent/detergent powder etc. reconnecting and re-fixing in position including cleaning and removing all scale dirt etc. from tanks and from mouth of circulating pipes etc. and writing the date of cleaning of tank and due date for cleaning of tank , capacity of tanks exc.250 liters and not exc. 500 liters complete all as specified and as directed
(Note: Each tank will be shifted twice)
10
-
-
S&F in repair CPVC gate valve 25mm dia complete all as specified and as directed
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements