Military Engineer Services Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Nov 2024
Closing Date4 Dec 2024
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682035_1Tender No
8518/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR TO INTERNAL ELECTRICAL WIRING, FITTING FIXTURES AND RELATED WORKS IN BUILDINGS IN ADM AREA, MESSES, SINGLE LIVING ACCN, FCM AND OI ETC AT AFA HYDERABAD
REPAIR TO INTERNAL ELECTRICAL WIRING, FITTING FIXTURES AND RELATED WORKS IN BUILDINGS IN ADM AREA, MESSES, SINGLE LIVING ACCN, FCM AND OI ETC AT AFA HYDERABAD
REPAIR TO INTERNAL ELECTRICAL WIRING, FITTING FIXTURES AND RELATED WORKS IN BUILDINGS IN ADM AREA, MESSES, SINGLE LIVING ACCN, FCM AND OI ETC AT AFA HYDERABAD
BOQ Items
(a) One light point controlled by one switch
80
-
-
(b) One light point controlled by two nos 2 way switches
10
-
-
(c) One ceiling / Exhaust fan point controlled by one switch
30
-
-
(d) One three pin socket 5 Amps independent with 1.5 sq mm coppper conductor
100
-
-
(e) One Bell point controlled by one way bell switch
5
-
-
(f) One three pin socket 5 Amps plug point on same board
10
-
-
M & L for Point wiring with 1.5 Sqmm multistranded copper conductor wire with unsheathed, FRLS grade PVC insulated, single core with earth continuity conductor of 1.5 sqmm FRLS grade PVC insulated multistranded copper conductor and including rigid PVC Casing & capping of suitable size and all accessories fixed to the surface of the roof/ walls or in chases etc. including PVC terminal boxes for fixing of switches, fan regulators socket outlet etc. complete all as specified and as directed for the following :-
-
-
-
(a) One light point controlled by one switch
85
-
-
(b) One light point controlled by two Nos, 2 way switches
17
-
-
(c) One ceiling / Exhaust fan point controlled by one switch
40
-
-
(d) One three pin socket 5 Amps plug point independent
100
-
-
(e) One Bell point controlled by one way bell switch
25
-
-
(f) One three pin socket 5 Amps plug point on same board
10
-
-
All as per Ser item No 3 above but with 2.5 sq mm multistranded copper wire with 2.5 Sq mm multistranded copper wire as earth continuity conductor in and including PVC conduit (not less than 20 mm) complete all as specified and as directed for 15A socket.
80
-
-
All as per Ser item No 10 above but with 2.5 sqmm copper cable in the casing & capping complete all as specified and as directed 15A socket.
80
-
-
S&F in repairs of ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed.
265
-
-
S&F in repairs 2 way switch polycorbonate white 6A, 240Volts complete all as specified and as directed.
17
-
-
S&F in repair of Switch Piano type polycorbonate white 1 way, 6A, 240Volts complete all as specified and as directed.
255
-
-
S&F in repair of Bell Switch flush type polycorbonate white 6A 240Volts complete all as specified and as directed.
25
-
-
S&F in repair of Socket outlet polycorbonate white 6A - 2/3 pin complete all as specified and as directed.
15
-
-
S&F of Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 flush type universal complete all as specified and as directed.
200
-
-
S&F in repairs of Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 flush type universal complete all as specified and as directed.
150
-
-
S&F of Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and as directed.
150
-
-
S&F in repair of Switch Piano type polycorbonate white 1 way, 6A, 240Volts complete all as specified and as directed.
540
-
-
S&F in repair of Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and as directed.
150
-
-
S&F in repair of Switch 15 Amp flush type universal complete all as specified and as directed.
10
-
-
S&F in repair of Socket out let polycorbonate white 2 in 1, 3 pin, 15 Amp flush type universal complete all as specified and as directed.
10
-
-
S&F in repair of Bell Multi Music type / Ding Dong AC 230 V complete all as specified and as directed
25
-
-
S&F in repair of stepped type polycorbonate white electronic fan regulator flush type complete all as specified and as directed.
70
-
-
S&F in repair of polycarbonate white angle holder/batten holder insulated complete all as specified and as directed.
50
-
-
S&F in repair of PVC Gang Box suitable for 5Amps Switch Socket Combination complete all as specified and as directed.
300
-
-
S&F in repair of PVC Gang Box suitable for 15Amps Switch Socket Combination complete all as specified and as directed.
300
-
-
S & F in repair modular switch 6 Amp one way 230 V AC complete all as specified and as directed.
70
-
-
S & F in repair modular switch 16 Amp one way 230 V AC complete all as specified and as directed.
70
-
-
S & F in repair modular switch 6 Amp bell push, 230 V AC complete all as specified and as directed.
70
-
-
S & F in repair modular socket outlet 6Amp intel multi socket for all pins 230 V AC complete all as specified and as directed.
70
-
-
S & F in repair modular socket outlet 16Amp and 6/16 Amp heavy duty 230 V AC complete all as specified and as directed.
70
-
-
S & F in repair modular step type fan regulator heavy duty 230 V AC complete all as specified and as directed.
70
-
-
Supply & Fixing 1x10W LED Tube light fitting having housing with high pressure die cast aluminium, poly carbonate front diffuser cover including LED driver, Lamp and all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable with cross sectional area 1.0 Sqmm including taking out old unserviceable one complete all as specified and as directed. Make- Luker Cat No- LT510P
355
-
-
S&F surface mounting / wall mounted LED tube light fitting 1x20 Watt (Lumen output not less than 1980 lumen) high efficiency, anti glare, maintenance free operation including LED driver, Tube 20W/18W and mounting arrangements, all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable white colour with suitable size including taking out old unserviceable one complete all as specified and as directed. Make- Luker Cat No- LT520P
551
-
-
S&F LED street light luminaries 35W 230 V AC including suitable inbuilt driver and complete accessories with MS housing finished & having clear acrylic cover, and provision of 1.20 mtr bracket made with light grade GI pipe of 25 mm dia for fixing on walls with MS flat (25mm X 3mm) clamps and anchorfastner after removing the unserviceable fitting complete all as specified and as directed.
30
-
-
S&F flush / surafce type light fittings of size 600x600mm suitable for 36W LED complete with inbuilt driver surface mounted/recessed type slim box type luminaries with CRCA housing white powder coated finish suitable to operate with 230 V AC, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with cross sectional area 1.0 Sqmm after removing old U/S rusted fittings complete all as specified and as directed.
50
-
-
S&F flush surface/rcessed type light fittings square / round as per site requirement suitable for 18 W LED complete with inbuilt driver surface mounted slim box type luminaries with CRCA housing white powder coated and finish suitable to operate with 220 V AC complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size after remove old U/S rusted fittings complete all as specified and as directed. . Make- Luker Cat No- LNPR18
50
-
-
S&F laminated hylum sheet 3 mm thick with suitable chromium plated machine screws with cup washers for fixing switches/ sockets etc including cutting for accommodating the switches / sockets and removing the damaged switch plates by carefully removing the switches /wiring/ sockets for refixing and re connecting the removed wires testing the circuits complete all as specified and as directed.
4
-
-
Taking out old unserviceable MCB and S&F of single pole and neutral enclosure with a two pin and earth plug and socket complete with one number single pole MCB 20 Amps , 240 Volts complete all as specified and as directed.
35
-
-
M&L for Sub Main wiring with four runs of 10sq mm 1100 V grade (nominal area) single core FRLS grade PVC insulated unsheathed wire with multi-stranded copper conductor, drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with two runs of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed.
80
-
-
Note :- (i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
-
-
-
(ii) Same size wire shall be used for phase, neutral & earth conductor
-
-
-
(iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
-
-
-
(iv) Six runs of cable and one run of PVC conduit / casing caping will be measured as one length.
-
-
-
M&L for Sub Main wiring with four runs of 6sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable sizewith all necessary fittings, surface in walls/roof/floor duly earthed with two run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed.
80
-
-
Note:-(i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
-
-
-
(ii) Same size wire shall be used for phase, neutral & earth conductor
-
-
-
(iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
-
-
-
(iv) Six runs of cable and one run of PVC conduit / casing caping will be measured as one Length.
-
-
-
M&L for Sub Main wiring with two runs of 6sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable sizewith all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed.
75
-
-
Note:-(i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
-
-
-
(ii) Same size wire shall be used for phase, neutral & earth conductor
-
-
-
(iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
(iv) Three runs of cable and one run of PVC conduit / casing caping will be measured as one uint.
-
-
-
M&L for Sub Main wiring with two runs of 6sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including existing conduit with all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed.
110
-
-
Note:-(i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
-
-
-
(ii) Same size wire shall be used for phase, neutral & earth conductor
-
-
-
(iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
-
-
-
M&L for Sub Main wiring with two runs of 4sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable sizewith all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed.
100
-
-
Note :- (i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
-
-
-
(ii) Same size wire shall be used for phase, neutral & earth conductor
-
-
-
(iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
(iv) Three runs of cable and one run of PVC conduit / casing caping will be measured as one uint.
-
-
-
M&L for Sub Main wiring with two runs of 2.5sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable sizewith all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed.
100
-
-
Note:-(i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(ii) Same size wire shall be used for phase, neutral & earth conductor
(iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
(iv) Three runs of cable and one run of PVC conduit / casing caping will be measured as one uint.
-
-
-
M&L for Sub Main wiring with two runs of 2.5sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including existing conduit with all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed.
100
-
-
Note :- (i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(ii) Same size wire shall be used for phase, neutral & earth conductor
(iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
-
-
-
Taking out old unserviceable distribution board of any type and S&F of MCB DB SPN 4 way with copper bus bar & neutral link double door type to be fixed in the wall including connections and making good the disturbed surface of wall to perfectly match with the exsting wall complete all as specified and as directed.
10
-
-
Taking out old unserviceable distribution board of any type and S&F of MCB DB SPN 8 way with copper bus bar & neutral link double door type to be fixed in the wall including connections and making good the disturbed surface of wall to perfectly match with the exsting wall complete all as specified and as directed.
15
-
-
Taking out old unserviceable distribution board of any type and S&F of MCB DB SPN 12 way with copper bus bar & neutral link double door type to be fixed in the wall including connections and making good the disturbed surface of wall to perfectly match with the exsting wall complete all as specified and as directed.
5
-
-
Taking out old unserviceable distribution board of any type and S&Fof MCB DB double door 4 way triple pole vertical type 415 volts 50 Hz AC supply suitable for 4 pole MCCB incomer, fixed to the existing wall (concealed/surface) after removing the existing un serviceable MCB DB and reconnecting the electrical connections and making good the disturbed surface of wall to perfectly match with the existing wall complete all as specified and as directed.
10
-
-
Taking out old unserviceable distribution board of any type and S&F of MCB DB,,double door 8 way triple pole vertical type 415 volts 50 Hz AC supply suitable for 4 pole MCCB incomer, fixed to the existing wall (concealed/surface) after removing the existing un serviceable MCB DB and reconnecting the electrical connections and making good the disturbed surface of wall to perfectly match with the existing wall complete all as specified and as directed.
Note : MCCB will be measured and paid separately under relavant items.
5
-
-
Taking out old unserviceable distribution board of any type and S&F of MCCB 4 pole 63Amps, 16KA breaking capacity, 415Volts 3-phase supply complete all as specified and as directed.
20
-
-
Taking out old unserviceable distribution board of any type and S&F of MCCB 4 pole 100Amps, 16KA breaking capacity, 415Volts 3-phase supply complete all as specified and as directed.
20
-
-
Taking out old unserviceable MCB any type and S&F of MCB SPN 6A to32A, 10KA rupturing capacity complete all as specified and as directed.
50
-
-
Taking out old unserviceable MCB any type and S&F of Fix MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
200
-
-
Taking out old unserviceable and supply and fixing 415V 10 KA 'C' type MCB TP 25 to 63 amp complete all as specified and as directed
35
-
-
S&F Focus light 1x3 W LED complete with inbuilt driver luminaries with CRCA housing white powder coated and finish suitable to operate with 220 V AC complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. .Make-Luker Cat No-LSP03
15
-
-
S&F flush picture light 1x12 W LED complete with inbuilt driver luminaries with CRCA housing white powder coated and finish suitable to operate with 220 V AC complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. .Make-Luker Cat No- LMCL12
10
-
-
Supply & Fixing 1x5W LED Tube light 1 feet fitting having housing with high pressure die cast aluminium, poly carbonate front diffuser cover including LED driver, Lamp and all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable with cross sectional area 1.0 Sqmm including taking out old unserviceable one complete all as specified and as directed. Make- Luker Cat No- LT505P
255
-
-
Supply & Fixing 1x9W LED duro panel light fitting of size 150mmx150mm having housing with high pressure die cast aluminium, poly carbonate front diffuser cover including LED driver, Lamp and all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable with cross sectional area 1.0 Sqmm including taking out old unserviceable one complete all as specified and as directed. Make- Luker Cat No- LT505P
16
-
-
Supply & Fixing 1x7W LED spot light having housing with high pressure die cast aluminium, poly carbonate front diffuser cover including LED driver, Lamp and all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable with cross sectional area 1.0 Sqmm including taking out old unserviceable one complete all as specified and as directed. Make- Luker Cat No- LCOB07N
16
-
-
Supply & Fixing High Bay industrial LED Luminaire 150 watts power factor 0.95, power consumption 150 watts rated Liminous Lux-15000Lm,color Temperature -6000K (WH) complete with all fixing accessories,clamps nuts, bolts, and necessary connection from nearby existing ceiling rose by providing 3 core multiflexible round copper wire of size 1.5 sqmm complete all as specified and directed. Make -Luker Cat No- LHBY150
12
-
-
M&L for comprehensive maintenance of online UPS of following capacities. These includes OEM Engineer visit periodically in every Four months for regular maintenance and for break down maintenance should be attend as and when required /initiation within 24 hours. Note- Quoted rate is inclusive of cost for all defective spares to be replaced for satisfactory performance of UPS till complete contract period.
(a) 20 KVA UPS
1
-
-
(b) 10 KVA UPS
1
-
-
(c) 5 KVA UPS
5
-
-
(d) 2.5 KVA UPS
3
-
-
Supply and fixing of Maintenance free Batteries of capacity 12 V 65 AH,240 volts,50 HZ complete all as specified and as directed. Make :- Exide / Amron / Amco
10
-
-
Supply and fixing of Maintenance free Batteries of capacity 12 V 150 AH,240 volts,50 HZ complete all as specified and as directed. Make :- Exide / Amron / Amco
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%