Military Engineer Services Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
₹ 93,320Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_676123_1Bid Award Id
ViewTender No
8851Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Taking down unserviceable compressor unit from ACs/watercoolers/ refrigerators by dismantling all electrical/gas connection and S&F new sealed compressor unit complete including vacuuming, gas charging, connecting all electrical and gas pipe connection and testing complete all as directed for the following capacities: -
-
-
-
Split/Window type AC of 1.5 ton capacity
20
-
-
Split/Window type AC of 2 ton capacity
20
-
-
Vertical type AC of 3 ton capacity
3
-
-
Split (Cassette type) AC of 3 ton capacity
3
-
-
Split (Cassette type) AC of 4 ton capacity
3
-
-
Tower AC of 1.5 ton capacity.
Make for srl item Nos. 4.01 to 4.06 :- Voltas/Carrier/LG/DAIKIN/ as per existing make.
2
-
-
Disconnecting the blower motor from the unit and taking out burnt copper wire from the motor and rewinding the motor with super enamelled copper wire as per existing gauge, varnishing, heating including replacement of existing unserviceable bushes & bearings complete and reconnecting the blower motor to the unit properly, making electrical connection for proper functioning of ACs/ watercoolers / refrigerators /air coolers / tower ACs of following capacity complete all as directed.
-
-
-
Split/Window type AC of 1.5 ton capacity
30
-
-
Split/Window type AC of 2 ton capacity
10
-
-
Vertical type AC of 3 ton capacity
2
-
-
Split (Cassette type) AC of 3 ton capacity
3
-
-
Split (Cassette type) AC of 4 ton capacity
3
-
-
Fresh air outdoor type air handling unit, delivery capacity of 12000 CFM
1
-
-
Tower AC of 1.5 ton capacity
Make for srl item Nos. 5.01 to 5.07 :- AVG/CG/BAJAJ/LG
1
-
-
Taking down unserviceable condensor unit from AC by dismantling all electrical/gas connection and S&F new condensor unit complete including vacuuming, gas charging, connecting all electrical and gas pipe connection and testing complete all as directed for the following capacity: -
-
-
-
Split/Window type AC of 1.5 ton capacity
35
-
-
Split/Window type AC of 2 ton capacity
20
-
-
Taking down unserviceable evaporator unit from AC by dismantling all electrical/gas connection and S&F new evaporator unit complete including vacuuming, gas charging, connecting all electrical and gas pipe connection and testing complete all as directed for the following capacity: -
-
-
-
Split/ Window type AC of 1.5 ton capacity
30
-
-
Split/Window type AC of 2 ton capacity
Make for item Srl No 6.01,6.02,7.01 & 7.02 :- Voltas/ Carrier/ Blue star/ LG/ Daikin/Hitachi
15
-
-
Taking down unserviceable following spare parts from Split / Tower type AC 1.5 to 4 Ton capacity and S&F new spare parts as per existing make and model all as directed
-
-
-
Air filter pad coir
20
-
-
Power circuit board
30
-
-
Remote controlled unit with hand set
20
-
-
Blower motor for fan
Make : AUE/CG/Usha/Bajaj
20
-
-
Relay assembly
Make : Sriram/Annapurna/C&S/L&T/ABB/SEIMENS
15
-
-
Over load protection
Make : Sriram/Ranutrol//C&S/L&T
25
-
-
Running capacitor
60
-
-
Starting capacitor
Make for srl items Nos.8.07 & 8.08 :- Usha/Universal/ Bhel/ TIBCO/CAPCO
60
-
-
Fan blade assembly
15
-
-
Oscillating motor
20
-
-
Blower with blower housing assembly
30
-
-
S&F flexible cable of size 6 Sqmm 3 core copper conductor multistranded 1100 volts grade, PVC insulated and PVC sheathed of size 6 Sqmm including taking down unserviceable cable complete all as directed.
300
-
-
S&F flexible cable of size 6 Sqmm 4 core copper conductor multistranded 1100 volts grade, PVC insulated and PVC sheathed of size 6 Sqmm including taking down unserviceable cable complete all as directed.
400
-
-
S&F Polythene foam insulation of copper tube for gas/liquid of air conditioner including necessary arrangements to be fixed upto third floor complete all as diected.
Note: (i) The ladders and safety equipment shall be provided by the contractor and cost of the same shall be deemed to be included in the quoted rate. (ii) While quoting the rate height of the building shall also be considered.
300
-
-
S & F Copper tube of the following size for gas/liquid with insulation for split type AC to be fixed on wall up to third floor including all arrangements and taking down unserviceable tube complete all as directed.
-
-
-
5/8"
300
-
-
1/4"
300
-
-
PVC water drain pipe 15/20mm dia including saddles and other accessories
Note :
(i) The ladders and safety equipment shall be provided by the contractor and cost of the same shall be deemed to be included in the quoted rate. (ii) While quoting the rate, height of the building shall also be considered.
400
-
-
Shifting of Split type AC, any type/capacity upto third floor, from one position to a new position by removing all electrical connection and copper tube connection with proper way and making good the old existing position by cement plaster and spray painting of out door unit painting with existing colour and fixing of AC at new position including making all electrical connection, copper tube connection and all arrangements for fixing complete all as directed.
Note :- Gas charging , extention of copper tube and cord cable shall be measured and paid separately under relevent item.
40
-
-
Servicing fresh air outdoor type air handling unit, of delivery capacity of 12000 CFM, cleaning inside/outside of the HDPE tank of 1000 ltrs capacity, air ducting, diffusers and making dust free unit by using blower including testing complete all as directed.
1
-
-
Servicing fresh air outdoor type air handling unit, of delivery capacity of 5.5 TR, cleaning inside/outside of the air ducting, diffusers and making dust free unit by using blower including testing complete all as directed.
1
-
-
Taking down unserviceable following spare parts from ductable type AC Plant of capacity 5.5 TR capacity and S&F new spare parts as per existing make and model all as directed.
-
-
-
Blower motor 0f 3 HP sutable for 5.5 TR capacity duct AC as per existing make & model
Make : AUE/CG/Usha/Bajaj
2
-
-
Liquid line filter drier make Carrier Model no PMH165F
2
-
-
Power contractor MNX-A1sutable for 5.5 TR capacity duct AC as per existing make & model
2
-
-
Power contractor MNX-A2 sutable for 5.5 TR capacity duct AC as per existing make & model
2
-
-
Running capacitor sutable for 5.5 TR capacity duct AC as per existing make & model
4
-
-
Starting capacitor sutable for 5.5 TR capacity duct AC as per existing make & model
4
-
-
Taking down unserviceable Danfoss Commercial compressors for ductable AC plant of 5.5 Ton capacity electrical/gas connection and S&F new sealed compressor unit complete including vacuuming, gas charging, connecting all electrical and gas pipe connection and testing for sutable existing make & modelcomplete all as directed
2
-
-
Supply, Installation, testing and commissioning of split type Air Conditioner 1.5 TR capacity inverter type 5star rated, single phase, 230 volts complete with all accessories as provided by the manufacturer such as indoor, outdoor units refrigerant copper tubing insulation packing and water outlet pipe to be brought out side and electrical copper cable PVC insulated multistranded sheathed 3 core of adequate size and length, and metal stand / PCC base as per site condition shall be provided and any additional refrigerant pipe line and cable shall be measure and paid seperatly including dismatling existing old AC Set complete all as directed. Make : Dakin/Hitachi/LG/Carrier/Samsung
5
-
-
Supply, Installation, testing and commissioning of split type Air Conditioner 2 TR capacity inverter type 5star rated, single phase, 230 volts complete with all accessories as provided by the manufacturer such as indoor, outdoor units refrigerant copper tubing insulation packing and water outlet pipe to be brought out side and electrical copper cable PVC insulated multistranded sheathed 3 core of adequate size and length, and metal stand / PCC base as per site condition shall be provided and any additional refrigerant pipe line and cable shall be measure and paid seperatly including dismatling existing old AC Set complete all as directed. Make : Dakin/Hitachi/LG/Carrier/Samsung
Note:- 19 and 20 dismantled AC set shall be deposited in MES Store
3
-
-
S&F in repairs Electronic voltage stabilizer of 5 KVA capacity (suitable for wall mounted) for automatic operation, indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5% stabilizer complete all as directed.
Make - V-GUARD / KEELINE / BLUE GUARD
12
-
-
Servicing of DG Set by adjusting the fan belt with proper tension, cleaning the sulphated material deposited on battery terminals and refixing duly applying petroleum jelly and supply & fixing of Lubrication oil filter, Preline filter cartridge, Fuel filter cartridge, Air cleaner primary element, Air cleaner safety element, Filter coolant, Water separator, gaskets, Washers and leaking pipes/hoses including taking down unserviceable item complete all as directed for the following capacity DG set :-
Note:
(i) Servicing of DG Set shall be done by the technician from generator make and the cost shall be included in the quoted rate. (ii) The required transportation, repairing tools shall be arranged by the contractor and the cost shall be included in the quoted rate.
-
-
-
DG Set 40 KVA ( As per existing make - Kirloskar Green)
1
-
-
DG Set 63 KVA (As per existing make - Kirloskar)
3
-
-
DG Set 100 KVA (As per existing make - Kirloskar)
1
-
-
DG Set 125 KVA (As per existing make - Kirloskar)
1
-
-
DG Set 200 KVA (As per existing make - Cummins)
1
-
-
DG Set 400 KVA (As per existing make - Kirloskar)
1
-
-
Supply and filling of premium blue 15W /40 W lubricating oil and draining out the existing lubricating oil from the oil tank complete all as directed.
Make: Kirloskar oil super/Cummins/Castrol
300
-
-
Supply and filling of coolant 50-50 premix and draining out the existing coolant from the radiator complete all as directed .
Make: Kirloskar cool super plus/Cummins/Castrol
300
-
-
Supply and fixing V belt of existing size for the DG set of following capacities including taking down unserviceable belt complete all as directed .
Make: Kirloskar/Dunlop/Fenner .
-
-
-
DG Set 40 KVA
1
-
-
DG Set 63 KVA
3
-
-
DG Set 100 KVA
1
-
-
DG Set 125 KVA
1
-
-
DG Set 200 KVA
1
-
-
DG Set 400 KVA Note for Item srl No : 25.01 to 25.06 - Belt for Fan pulley, belt for Fan drive, belt for Water pump is measured as one set.
1
-
-
Supply and fixing Engine control unit for DG Set 200 KVA to 400 KVA including necessary cabling work and taking down unserviceable unit complete all as directed.
Make - Kirloskar/Cummins
2
-
-
Supply and fixing Base board with connector ports for DG set 200 KVA to 400 KVA including necessary cabling work & calibration complete and taking down unserviceable baseboard all as directed .
Make - Kirloskar/Cummins
2
-
-
Supply and fixing Automatic voltage regulator unit for the DG Set capacity 62.5 KVA to 125 KVA including necessary cabling work and taking down unserviceable regulator complete all as directed.
Make - Kirloskar/Cummins/Crompton Greaves
4
-
-
Taking down radiator from generator set capacity 62.5 KVA to 125 KVA, cleaning the radiator by using radiator cleaning agent including required brazing work and refixing the radiator complete all as directed .
2
-
-
Taking down radiator from generator set capacity 200 KVA to 400 KVA, cleaning the radiator by using radiator cleaning agent including required brazing work and refixing the radiator complete all as directed.
2
-
-
Dismantling self starter assembly from DG set of capactiy 62.5 KVA to 125 KVA and taking down unserviceable spares and supply & fixing new carbon brushes, armature starter drive assembly, pinion, solenoid switch, spindles, brush holder, contact sets, housing bush bimetal, killi kit, starter brush holder, gaskets including testing complete all as directed.
3
-
-
All as per srl item No.31 here in before but DG set of capacity 200 KVA to 400 KVA complete all as directed.
2
-
-
Dismantling alternator assembly from DG set of capacity 62.5 KVA to 125 KVA and taking down unserviceable spares and supply & fixing new main alternator assembly, coupling disc, exciter rotor, frame to end bracket adaptor ring, rotor assembly, stator assembly, fans, bearings, diode bridge assembly, gaskets including testing complete all as directed.
2
-
-
All as per item No.33 here in before but DG set of capacity 200 KVA to 400 KVA complete all as directed.
2
-
-
Dismantling FIP assembly from DG set of capacity 62.5 KVA to 125 KVA and taking down unserviceable spares and supply & fixing new plunger assembly, governor assembly, lever assembly, pump assembly, camplate, cam shaft, tappet roller, delivery valve, inlet valve, injector pin, gaskets, oilseal including calibration and testing complete all as directed.
2
-
-
All as per srl item No.35 here in before but DG set of capacity 200 KVA to 400 KVA complete all as directed.
2
-
-
Dismantling waterpump assembly from DG set of capacity 62.5 KVA to 200 KVA and taking down unserviceable spares and supply & fixing new pump, shaft, coupling, impeller, hub assembly, seal assembly, gaskets, including testing complete all as directed.
3
-
-
Supply and fixing the following items for DG set of capacity 62.5 KVA to 400 KVA including taking down unserviceable items complete all as directed.
-
-
-
Starter button
2
-
-
Ignition switch and key
2
-
-
Feed pump for engine including Diesel pump pipe engine head to diesel tank
4
-
-
Stop solenoid
2
-
-
Radiator Fan
2
-
-
Indication lamp (Red, Blue, Green
2
-
-
Battery terminal
5
-
-
Battery cable
Make for item srl No : 38.01 to 38.08 - Kirloskar/Crompton greaves/ Cummins
12
-
-
Supply and fixing Power contactor 4 pole, 315 amps, 415V including required cabling work complete and taking down unserviceable contactor all as directed.
3
-
-
Supply and fixing Auxilary contactor suitable for up to 400 KVA DG Set AMF Panel including taking down unserviceable contactor complete all as directed.
2
-
-
Supply and fixing Control Relay suitable for DG Set AMF panel of capacity up to 400 KVA including taking down unserviceable control relay complete all as directed.
2
-
-
Supply and fixing Overload Relay suitable for up to 400 KVA DG Set AMF Panel including taking down unserviceable over load relay complete all as directed.
2
-
-
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion including taking out old earth complete all as specified and directed.
10
-
-
S&F 2 ft x 2ft recess mounted full panel LED luminaire with white powder coated housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser , in built electronic driver duly wired up to terminal block, power consumption 36W, luminaire lumen 3500lm and system efficiency 120lm/W, CRI80, colour temp -5700K, Ingress protection IP 20, , driver efficiency 85%, 50,000 burning hours (min) , range 150-270V AC and safety extra low voltage safe level 60V DC including taking down old unserviceable light fitting of any description complete all as specified and directed. Make:- Havells/Philips/Wipro/Bajaj
10
-
-
S&F LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption =20W, luminaire lumen 2000 lm, system efficiency of 100 lumens/W, driver efficiency85%, power factor 0.9, THD 20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) including taking down old unserviceable light fitting of any description complete all as specified and directed. Make:- Wipro Model No. LL20-281-XXX-65AL1 or Havells Cat Part No. LUMILINE+BS20WLED830SPCSS/ technocomercially equivalent model of Philips/Bajaj
100
-
-
Supply and fix in replacement of single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into existing T8 conventional fluorescent tube light fitting after changing the necessary electric connections as required at site complete all as specified and directed. Make : Crompton, Cat No : LT8-20-865-2 , Havells, Cat No : PHOTONULTRA1213T8SSTL20WLED865SPC, PHILIPS Cat no MAS LED tube 1200 mm 18 w 865 T8 I - 2100 Lumen
100
-
-
S&F LED street light luninaires 120 Watt with pressure die cast aluminium housing , Heat resistant toughened glass with frame and IP 66 protection including taking down old unserviceble fitting of any type complete all as directed. Make: Crompton Cat part No. LSTP-120-CDL /Equivalent in Philips/ Havells/ Wipro
20
-
-
S&F LED street light luninaires 60 Watt with pressure die cast aluminium housing , Heat resistant toughened glass with frame and IP 66 protection including taking down old unserviceble fitting of any type complete all as directed. Make: Crompton Cat part No. LSTP - 60 -CDL /Equivalent in Philips/ Havells/ Wipro
20
-
-
S&F security light fitting bracket made out of GI tubing 40mm dia light grade of size 1.5m long, bent to shape including clamp for bracket made out of 50x6mm MS flat iron with necessary nut & bolts, washers complete and taking down unserviceable bracket complete all as directed.
Make : Tata/Jindal/Oswal
30
-
-
S&F Pole junction box, made up of sheet moulding compound (SMC) type with hinged type door and locking arrangement, white colour of size 280x170x130mm outside and 240x130x110mm internal dimensions comprising 01 No-16 Amps capacity kitkat fuse, aluminium busbar-04 Nos, earthing terminals, bolts & nuts and connecting up cables with aluminium terminal lugs including suitable size clamps,bolts, nuts and washers fixed on pole complete and taking down unserviceable junction box complete all as directed
Make - Sintex or equivalent ISI marked
30
-
-
S&F Change over switch 200 amps, four pole,415 amps with all accessories & suitable lugs including taking out old unserviceable change over switch complete all as directed.
2
-
-
S&F Change over switch 320 amps, four pole,415 amps with all accessories & suitable lugs including taking out old unserviceable change over switch complete all as directed. Make for Item srl No. 52,53: - Havells/Standard/L&T/CG
2
-
-
Attending complaints of DG sets whenever breakdown reported by JE E/M/Engineer in charge within 3 hours of reporting and replacing the minor defective parts and make the DG set serviceable at site to the satisfaction of Engineer in charge. Note :- Major defective parts will be measured and paid separately. If the contractor failed to attend the complaint within 3 hours of reporting then penalty of Rs 500/- per hour will be leveled on contractor.
25
-
-
Supply and fixing Electronic Timer suitable for up to 400 KVA DG Set AMF Panel including taking down unserviceable timer complete all as directed.
1
-
-
Supply and fixing Line voltage monitor suitable for up to 400 KVA DG Set AMF Panel including taking down unserviceable line voltage monitor complete all as directed .
1
-
-
Supply and fixing battery charger unit suitable for 63 KVA to 400 KVA DG Set through AMF Panel including taking down unserviceable battery charger complete all as directed.
3
-
-
Dismantling waterpump assembly from DG set of capacity 400 KVA and supply & fixing new pump of make Kirloskar including testing complete all as directed.
1
-
-
Supply, Installation, testing in door unit of split type Air Conditioner 1.5 TR single phase, 230 volts complete with all accessories as provided by the manufacturer complete all as directed. Make : Voltas/Dakin/Hitachi/LG/Carrier/Samsung
8
-
-
Supply, Installation, testing in door unit of split type Air Conditioner 2.0 TR single phase, 230 volts complete with all accessories as provided by the manufacturer complete all as directed. Make : Voltas/Dakin/Hitachi/LG/Carrier/Samsung
8
-
-
Supply, replacement, installation, testing and commissioning of LT distribution control Panel , Kiosk type 415 Volt, 4 wire AC 50 Hz, factory made, out door type double door, both side opening, (frount and rear side) weather and vermin proof panel having degree of protection IP-54 & made out of CRCA fabricated out of sheet of 3.15 mm outer structure and 1.6mm for internal structure with duly powder coated,CPRI approved , factory made fabricated and CPRI approved, 415 volts, with locking arrangement, powder coated MS angle iron base frame with legs of size 40 X 40 X 60mm and 60cm long grounted with PCC 1:3:6 type C-1 for foundation filling with platform 100 X 75 X 15 cm above ground level floor incuding cable entries with gland for incoming and out going cable connection, aluminium bus bar 4 strip rating 500 amps, including colring with RYB & Black including letter writen of pattern and description as directed with supply and fixing the following accessories pre-wired and connected alongwith suitable cable gland,lugs etc. all as specified and directed including taking out of unserviceable existing LT panel board and consisting of the items listed hereinafter.(Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work.)
1
-
-
(i) Incoming - MCCB 315 Amp rating with thermal seting ,35 KA, 3 pole – 01 No. (ii) Change over switch (on load) 250 Amps 4 pole 415 volts 50 Hz =01 No
(iii) Outgoing - MCCB 160 Amp with thermal seting,25 KA, 4 pole - 02 Nos (iv) MCCB 100 Amp,16 KA,4 pole - 02 No (v) MCCB 63 Amp,16 KA,4 pole - 01 No (vi) Digital Voltmeter& Ammeterwith selector switchs, ON and OFF push button,Indication lamps of 3 Nos for RYB - 01 Set (vii) MCB DP 40 Amps - 02 Nos (vi) Digital Ammeter (0-300) Amps with Cts 250/5 and selectors witch , Voltmeter (0-500) volts with selector switch , Indicating lamp set (RYB) LED type.
-
-
-
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as directed.
108
-
-
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick using soil complete all as directed.
63.7
-
-
Removing excavated material to a distance exc 250m but n exc. 500m and depositing where directed at a level n exc. 1.5m above the starting point (Soils) complete all as directed.
44.3
-
-
Supply and spreading natural dry, clean river sand in trenches for cushioning of cable complete all as directed.
32.4
-
-
M&L for brick protection with common burnt bricks sub class ‘B’ of size 230x115x75mm for cable protection complete all as directed.
5
-
-
S&F Laying LT UG cable heavy duty armoured with aluminum conductor multistranded PVC insulated and sheathed with suitable lugs including taking out old unserviceable cable complete all as directed for following sizes: -
-
-
-
4core 16 Sqmm
200
-
-
3.5 core 25 Sqmm.
250
-
-
3.5 core 35 Sqmm.
250
-
-
3.5 core 50 Sqmm.
Note: - .Excavation & earthwork, sand cushioning and brick protection shall be measured and paid seperately under relevant items.
Make for item 66.01 to 66.04 : Havells/Universal/Gloster/Polycab
200
-
-
S & F in replacement maintenance free battery of 180Ah, 12V incluing connecting with DG set terminals all as specified and directed
2
-
-
S & F in replacement maintenance free battery of 150Ah, 12V incluing connecting with DG set terminals all as specified and directed
2
-
-
S & F in replacement maintenance free battery of 100Ah, 12V incluing connecting with DG set terminals all as specified and directed
2
-
-