Military Engineer Services Tender

For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Jan 2025
Closing Soon8 Feb 2025
Tender Amount₹ 49,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
EOT Crane of 5 to 10 ton capacity-02 Nos

11

-

-

... More
EOT Crane upto 5 ton capacity - 18 Nos (two No at ATC Devatalagutta)

11

-

-

... More
HOT Crane of upto 5 ton capacity -01 No Note for srl item Nos.1.01 to 1.05:- Supply only spares required will be measured and paid separately under relevant items. Fixing element is deemed to be included in the quoted rate.

4

-

-

... More
Conducting of load and deflection test for the EOT and HOT cranes of following capacities and submitting the test report to Engineer-in-Charge.

-

-

-

... More
5 Ton to 10 Ton

10

-

-

... More
Above 10 Ton & upto 20 Ton

10

-

-

... More
Above 20 Ton & upto 25 Ton Note for item No 2.01 to 2.03 :- (a) The required loads are to be arranged by the contractor under his own arrangements including transporting to and fro the site without any extra cost to the department. (b) Crane testing is to be carried out by the authorised inspector as per factory act. and the test certificate duly signed by authorised inspector will be submited to Engr in chagre.

1

-

-

... More
Supply only Gear Oil of suitable for crane gear assembly. Make:- Servo/Castrol or equivalent.

250

-

-

... More
supply only Power Contactor 32 to 40 Amps type with 110 Volt coil voltage, three phase.

3

-

-

... More
Supply only Power Contactor 40 to 70 Amps type with 110 Volt coil voltage, three phase.

3

-

-

... More
Supply only spare kit for 32 to 40 Amps contactor

3

-

-

... More
Supply only spare kit for 60 to 70 Amps contactor

3

-

-

... More
Supply only push button of any type, Make : L&T/GE.

9

-

-

... More
Supply only Flexible geared coupling of any type/size

3

-

-

... More
Supply only Bimetal over load relays for contactors Make for srl item No. 10 & 11 : BCH/L&T/C&S/Telemech.

3

-

-

... More
Supply only push button assembly pendent type complete with all accessories including support hanging wire suitable for 5 Ton to 10 Ton, Make : L&T/GE/Cranex.

3

-

-

... More
Supply only of 1.5 sqmm 12 core Copper conductor cable PVC insulated & PVC sheathed flexible multistranded 1100 volts grade with in suitable with PVC conduit with clamps to fix on wall/railing complete as per site requirement

90

-

-

... More
Supply only 2.5 Sqmm, 10 core Copper conductor cable PVC insulated & PVC sheathed flexible multistranded 1100 volts grade with PVC conduit with clamps to fix on wall/railing complete as per site requirnment

90

-

-

... More
Supply only 6 Sqmm, 8 core copper conductor cable PVC insulated & PVC sheathed flexible multistranded 1100 volts gradewith PVC conduit with clamps to fix on wall/railing complete as per site requirnment

90

-

-

... More
Supply only 10 Sqmm, 6 core Copper conductor cable PVC insulated & PVC sheathed flexible multistranded 1100 volts grade.with PVC conduit with clamps to fix on wall/railing complete as per site requirnment Make:- Plaza/Polycab/Finecab/Finolex/Havells.

90

-

-

... More
Supply only thruster break oil for hydralic thruster break for long/cross travel/Hoist, Make : Servo/IOC/Bharat.

200

-

-

... More
Supply only steel wire rope flexible type 6 sqmm for pendent push button box with necessary clamps/clips etc.

50

-

-

... More
Supply only electro magnetic break with break drum for break disk or break coil of any size/type . Make:- BCH/Speed-O-Control or equivalent

2

-

-

... More
Supply only Main Hoist steel wire rope (as per existing size) suitable to 10 Ton EOT crane of adequate length and size including accessories.

1

-

-

... More
Supply only Main Hoist steel wire rope (as per existing size) suitable to 5 Ton EOT crane of adequate length and size including accessories.

1

-

-

... More
Material and labour for taking the gear box mechanism with necessary equipments carefully without any damaging and taking out to the authorised workshop/OEM serivice center if necessary or repair/replacement of gear oil, oil seal, pinion, reduction pinion, main gear, seconday reduction gear, shaft, bearing, coupling and other spares as required for proper functioning and refixing the same in its original position making all connections testing all parameters like CT & LT suitable for cranes up to 10 Tonand complete all as specified and directed. Note : Including transportation to and from the site and the cost for the same is deemed to be included in quoted rate.

1

-

-

... More
All as per item No. 19 here-in-before but for 15 to 20 Ton capacity crane

1

-

-

... More
Material and labour for taking down wheel set carefully using hydralic jack without any damaging and taking out to the authorised workshop/OEM serivice center if necessary or repair/replacement of Bearing, pinion, wheel teeth to be make for grip and other spares as required for proper functioning and apply greasing whereever required parts assembling the complete wheel set with connected item suitable for 3 ton to 10 crane and complete all as directed.

1

-

-

... More
All as per item No. 21 here-in-before but for 15 to 20 Ton capacity crane

1

-

-

... More
Supply and fix in repairs VVVF drive of crane upto 5 ton capacity drie should be suitable for the existing crane incluidng removing the unserviceable VFD drive complete all as directed.

1

-

-

... More
All as per item No. 23 here-in-before but for 5 to 10 Ton capacity crane

1

-

-

... More
Supply and fix in repairs VVVF drive control card of crane upto 10 ton capacity drive control card should be suitable for the existing crane incluidng removing the unserviceable VFD drive control card complete all as directed.

1

-

-

... More
All as per item No.25 here-in-before but for more than to 10 Ton upto to 25 Ton capacity crane

1

-

-

... More
Renewal of burnt out control wiring for 5 to 25 Ton crane with suitable size of copper cable and replacement of connectors, lugs, fuses etc and testing complete all as directed.

2

-

-

... More
Removing the existing burnt out flame proof main switch and supply and fix flame proof main switch 32 Amps, TP&N, 415 volts with necessary connections complete all as directed.

1

-

-

... More
Rewinding of Thruster motor of crane upto 25 Ton capacity with super enamelled copper conductor of same existing guage complete all as directed.

2

-

-

... More
Supply & fix HRC fuse 16A with fuse carrier complete including removing the unserviceable HRC fuse complete all as directed. Make : GE/L&T/BCH.

3

-

-

... More
Supply & fix HRC fuse 63A with fuse carrier complete including removing the unserviceable HRC fuse complete all as directed Make : GE/L&T/BCH.

3

-

-

... More
Periodical maintenance by the representative of concerned company each month of various Fire Alarm systems including checking, testing, cleaning of Smoke Detectors, Heat Detectors, manual call points, Hooters, Sirens etc.. by carrying out preventive Maintenance and corrective Maintenance for trouble free and efficient functioning of entire system, replacement of the accessories connected to the Fire Alarm systems for the buildings at Main building , New admin & ETC The work is to be carried out all as directed. Note : Spares if any required shall be measured and paid under the relevent items of schedule. and labour elment is deemed to be included in rate quoted.

11

-

-

... More
Supply, installation, testing including removing the unserviceable old following spares required for the efficient functioning of the Conventional Fire Alarm systems :-

-

-

-

... More
Photo electric (optical) Smoke detector with isolator base. Make : Godrej-VDS/Apollo/System Sensor

2

-

-

... More
Heat detector with isolator base. Make : Godrej-VDS/Apollo/System Sensor

2

-

-

... More
Ionization Smoke detector with base. Make : Godrej-VDS/Apollo/System Sensor

2

-

-

... More
Electronic Hooter Make : GST/Agni/System Sensor

1

-

-

... More
Manual call point . Make : Godrej-VDS/Agni/System Sensor/Securico

2

-

-

... More
Response indicator Make : Godrej-VDS/Agni/Securico

2

-

-

... More
Hooter . Make : Godrej-VDS/Agni/Securico

1

-

-

... More
Maintenance free Battery 12V, 7AH Make : Exide/Amco

15

-

-

... More
Manual call point switches. Make : Agni/Honeywell.

1

-

-

... More
Manual call point glass. Make : Agni/GST.

1

-

-

... More
24 volts potential free relay. Make : L&T/Siemens/Omran

2

-

-

... More
Siren controller contactor . Make : L&T / SIEMENS / GE

1

-

-

... More
Assorted Fuses. Make : GE/FTC.

2

-

-

... More
Supply, installation, testing, complete including removing the old unserviceable following spares required for the efficient functioning of the Analogue Addressable Fire Alarm systems :-

-

-

-

... More
Photo electric (optical) Smoke detector with isolator base. Make :Godrej-VDS/ Apollo/Morley IAS/GST

2

-

-

... More
Ionization Smoke detector with base Make : Godrej-VDS/Apollo/Morley IAS/GST

2

-

-

... More
Heat detector. Make : Godrej-VDS/Apollo/Morley/GST

1

-

-

... More
Electronic Hooter Make : Apollo/Morley IAS/GST

2

-

-

... More
Manual call point Make : Apollo/Morley IAS/GST

2

-

-

... More
Fault Isolators Make : Apollo/Morley IAS/GST

2

-

-

... More
Loop driver card Make : Apollo/Morley IAS/GST

2

-

-

... More
Data/Ribbon cable with connector. Make : Apollo/GST.

2

-

-

... More
M&L for 1.5 sqmm, 2 core copper conductor multistranded PVC insulated, sheathed FRLS cable conforming to IS specification with and including PVC conduit of suitable size suitable for Fire Alarm system complete including removing the unserviceable cable complete all as directed. Make : Godrej-VDS/FINOLEX/ORBIT/NEOLEX

90

-

-

... More
M&L for 2.5 sqmm , 2 core copper conductor multistranded PVC insulated, sheathed FRLS cable conforming to IS specification suitable with and including PVC conduit of suitable for Fire Alarm system complete including removing the unserviceable cable complete all as directed. Make : Godrej-VDS/FINOLEX/ORBIT/NEOLEX

90

-

-

... More
M&L for PVC conduit 15mm dia medium grade FRLS type suitable for Fire Alarm/street light poles from Looping box to GI bracket system including clamps and removing the unserviceable PVC conduit complete all as directed. Make : Godrej-VDS/FINOLEX/ORBIT/NEOLEX

90

-

-

... More
S&F addressable 1/2 loop microprocessor based master fire alarm panel with its own battery charger, battery for 24 hours backup including testing and removing the unserviceable fire alarm panel, complete all as directed. Make : Boss/Honeywell/Agni.

1

-

-

... More
Supplu & fix in replacement the sign board of Assistant garrison Engineer E/M-I GE(I) R&D kanchanbagh, Military Engineer Services with LOGO of (MES) sign Board Details: 3.5ft x5.5ft ACP Panel (aluminium composite panel) 3mm thickness white colour or grey colour.aerylie litters will fix on panel.letters in Aerylic 6mm or 8mm thickness computerised scrpt CNC laser cutting letters in imported Aerylic.

1

-

-

... More
M&L for Power supply and Battery charging board for 4 zone micro processor based Fire Alarm panel including removing the unserviceable battery charging board complete all as directed. Make : Ravel/GST/Agni

1

-

-

... More
M&L for power supply and Battery charging board for 8 zone micro processor based Fire Alarm system including removing the unserviceable battery charging board complete all as directed. Make : Ravel/GST/Agni

1

-

-

... More
M&L for display and control mother board for 4 zone micro processor based Fire Alarm system complete including removing the unserviceable display and control board complete all as directed. Make : Ravel/GST/Agni

1

-

-

... More
M&L for display and control mother board for 8 zone micro processor based Fire Alarm panel complete including removing the unserviceable display and control board complete all as directed. Make : P100/GST/Agni

1

-

-

... More
Suppy and fixing in repair 4 zone Fire Alarm panel complete including removing the unserviceable panel complete all as directed. Make : Ravel/GST/Agni

1

-

-

... More
Suppy and fixing in repair 8 zone Fire Alarm panel complete including removing the unserviceable panel complete all as directed. Make : Ravel/GST/Agni

1

-

-

... More
Disconnecting and removing of unserviceable levelling/stopping/slowing sensors and Supply and Fix of new levelling/stopping/slowing sensor complete all as directed.

1

-

-

... More
Disconnecting and removing of unserviceable Mechanical switches stopping/slowing and Supply and Fix new Mechanical switches stopping/slowing complete all as directed.

1

-

-

... More
Disconnecting and removing of unserviceable Break coil and Supply and Fix of new Break coil complete all as directed.

1

-

-

... More
Maintenance of DG set and carrying out ‘B’ check and replacement of ‘B’ check kit filters such as Oil filter, by pass filter, fuel filter,CR element and CR plates complete with ‘O’ rings and draining of Engine oil and topping up with the new engine oil complete testing all as specified and directed by the Engr-in-Charge for the following capacity DG sets:- Note :- 1. Engine oil shall be measured and paid separately. 2. B Cheak to be carried out every after 250 hrs run or 6 months whichever is earlier. Make: KIRLOSKER/ CUMINS /GREAVES

-

-

-

... More
20 KVA DG Set

2

-

-

... More
40 KVA DG Set

2

-

-

... More
125 KVA DG Set

4

-

-

... More
250 KVA DG Set

2

-

-

... More
320 KVA DG Set

6

-

-

... More
400 KVA DG Set

4

-

-

... More
500 KVA DG Set

4

-

-

... More
625 KVA DG Set

2

-

-

... More
Renewal of unserviceable batteries with maintenance free batteries of 180 AH, 12V including connecting to DG set complete all as directed. Make:- EXIDE/ AMARON

4

-

-

... More
Attending the breakdown of any capacity/make DG Sets, AMF Panels, by Technician & helper for checking all components and identifying and rectifying the faults and give report to concerned JE complete all as directed. Note:- Spare Parts for rectifying the fault shall be measured and paid seperately.

15

-

-

... More
S&F in repairs automatic voltage regulator (AVR) upto 40 KVA DG set and testing complete all as directed. Make:- As per OEM make.

1

-

-

... More
S&F in repairs automatic voltage regulator (AVR) 125 to 250 KVA DG set and testing complete all as directed. Make:- As per OEM make.

1

-

-

... More
S&F in repairs automatic voltage regulator (AVR) 320KVA to 630 KVA DG set and testing complete all as directed. Make:- As per OEM make.

1

-

-

... More
Dismantling of exhaust pipe of the DG set by unscrewing nuts and bolts and taking down the pipe with muffler, removing the burnt out asbestos rope and well wrapping with new aluminium metal cladding with glass wool including cleaning the silencer, and fixing the same in its original position complete all as directed for the following capacity DG Sets.

-

-

-

... More
125KV to 250 KVA DG set.

1

-

-

... More
320 KV to 630 KVA DG set.

1

-

-

... More
Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 24 volts, 180 /200 AH and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts such as bearing, carbon brushes, clutch plates etc refixing the self starter in its original position, testing and commissioning complete all as directed. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule fixing included in this item.

1

-

-

... More
Supply only Armature coil for self starter of any make of any capacity and of any model 24 Volts, 180/200 AH complete all as directed.

1

-

-

... More
Supply only of field coil for self starter of any make, any capacity and any model 24 Volts, 180 /200AH complete all as directed .

1

-

-

... More
Disconnecting all electrical connections from the unserviceable self starter of any make/capacity/model 12 volts, 180, 200 AH and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts bearing, carbon brushes, clutch plates etc refixing the self starter in its original position, testing and commissioning complete all as directed. Note:- Supply of Armature coil, field coil shall be measured & paid separately under relevant items of this Schedule.

1

-

-

... More
Supply only Armature coil for self starter of any make, any capacity and any model 12 Volts, 180/200 AH complete all as directed.

1

-

-

... More
Supply only of field coil for self starter of any make, any capacity and any model 12 Volts, 180/200 AH complete all as directed.

1

-

-

... More
Disconnecting the oil cooler of 110 KVA to 250 KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed.

1

-

-

... More
S&F in repairs air cleaning element inner and outer with necessary ‘O’ rings for the DG sets of following capacities as that of existing make and model complete all as directed.

-

-

-

... More
Upto 40KVA DG Set

1

-

-

... More
125 KVA to 250 KVA DG Set

1

-

-

... More
320 KVA to 630 KVA DG Set

1

-

-

... More
Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and of various capacities of DG sets and taking down the radiator assembly by unscrewing all mechanical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of radiator assembly cleaning thoroughly the chocked pipe of the radiator by using detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers etc., complete all as directed for the following DG sets:-

-

-

-

... More
Upto 40 KVA DG Set

1

-

-

... More
125 KVA to 250 KVA DG Set

1

-

-

... More
320 KVA to 630 KVA DG Set

1

-

-

... More
Renewal of battery cable leads of copper conductor with brass lugs terminal, for the 12V 180 /200 AH batteries for self stater as that of existing size and length complete all as directed.

2

-

-

... More
S&F in repairs automatic cut off Battery Charger suitable for 110V, up to 40 Amp Battery complete all as directed . Make SMPS/ Phonix or

2

-

-

... More
S&F in repairs automatic cut off Battery Charger suitable for 12/24 V, up to 40 Amp Battery complete all as directed. Make SMPS/ Phonix

2

-

-

... More
Renewal of 'V' belts for the following capacity DG sets as per existing size and model complete all as directed. Make :- FENNER/ DUNLOP

-

-

-

... More
Upto 40KVA DG Set

2

-

-

... More
125 KVA to 250 KVA DG Set

2

-

-

... More
320 KVA to 630 KVA DG Set

2

-

-

... More
Renewal of existing unserviceable water temperature gauge for the DG set of any description complete all as directed.

2

-

-

... More
Renewal of existing unserviceable lubricant oil temperature guage for the DG set of any capacity complete all as directed.

2

-

-

... More
Renewal of existing unserviceable oil pressure gauge for the DG SET of any capacity complete all as directed .

2

-

-

... More
Renewal of unserviceable Solenoid switch for DG set of any make and any capacity complete all as directed. Make :- RUSTON/ GREAVES COTTON/Kirloskar/CUMMINS.

2

-

-

... More
Supply and filling the new engine oil 15W/40 for toping up, upto the required level complete all as directed. Make :- CASTROL/ INDIAN OIL/ SERVO

300

-

-

... More
Drain out the fuel from the fuel tank of DG set of capacity 600 Ltrs and above and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as directed.

2

-

-

... More
Removing of defective engine oil control pressure switch and supply & fix new engine oil control pressure switch suitable for up to 250 KVA set complete all as directed. Make Kirloskar- Cummins

1

-

-

... More
Renewal of defective wiring with copper wire of existing size including replacement of electrical/ electronic parts of AMF panel & DG Set, complete all as directed. Note: - Supply only Electrical/ Electronic spare parts shall be measured and paid separately.

2

-

-

... More
Supply only of following spare parts :

-

-

-

... More
Auxiliary contactor 240 Volts, (2NO.+2NC).

2

-

-

... More
ON and OFF delay timer 240 V AC and 24 V DC.

2

-

-

... More
Over load relay.

2

-

-

... More
ML - 4 contactor.

2

-

-

... More
Earth Fault Relay IRII-31-E1-WD Suitable for 250 V, AC. Make: C&S

1

-

-

... More
Single phase preventer

2

-

-

... More
Auxiliary Relays 24Volts / 6A

2

-

-

... More
PLC based AMF relay unit

3

-

-

... More
Low lube oil safety switch

1

-

-

... More
Booster Relay 24Volts / 10A

2

-

-

... More
Battery charger 24 V /10A panel mounting type

3

-

-

... More
Coolant temparature sensor

2

-

-

... More
LED indicating Lamp

9

-

-

... More
Push buttons

5

-

-

... More
Selector switches

5

-

-

... More
Removing the defective charging dynamo of capacity 24 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the same replacing of armature, field coils reconnecting the same, refixing back, in original position testing and commissioning complete all as directed.

1

-

-

... More
Supply & topping up of Inhibitor corrosion (coolant additive concentrate) as required (TVS Make) complete all as directed.

300

-

-

... More
Supply and topping up of distilled water suitable for lead acid batteries of 12 volts complete all as directed.

300

-

-

... More
Dismantling/taking out old unserviceable alternator (charging of battery) and taking out worn out spares such as ammeter, brush and field winding and repair the same by replacing ammeter, brush and rewinding of field coil with same guage of copper wire and testing complete all as directed .

1

-

-

... More
Calibration of PT pump and replacement of PT Pump kit, gear gasket, etc whichever is required for smooth functioning of DG Set complete all as directed.

1

-

-

... More
Calibration of injectors by replacing injector cup, barrel plunger for smooth functioning of engine, testing complete all as directed .

1

-

-

... More
S&F PVC insulated, heavy duty, unshealted , multi Stranded Copper Cable of 35 Sqmm single core with suitable size lugs crimped on both side complete all as directed.

15

-

-

... More
S&F Flexible Bellow suitable up to 125 KVA Gen Set. Make as per OEM

1

-

-

... More
Disconnecting of alternator from 125 KVA to 250 KVA capacity DG set, after Disconnecting from Generaror shifting to civil workshop, taking out burnt out winding from Stator & Rotator, Cleaning thoroughly and rewinding the stator,rotor with suitable guage of super enameled copper conductor similar to that of existing size including necessary insulating material varnishing, heating,replacing bearings in rotor and stator side, reassembling of alternator, bringing back to the site refixing and installation over foundation with proper alignment, testing and commissiong complete all as directed. Note :- cost of taking up and down from the site to workshop vice versa with vehicle and necessary labour shall be deemed to be included in quoted rates.

1

-

-

... More
ditto but for 320KVA to 630 KVA DG Set

1

-

-

... More
Supply, fix and test run the Fly-wheel Ring of existing model,size suitable for DG set of capacity 63 to 250 KVA including taking down old unserviceble fly wheel ring complete all as directed.

2

-

-

... More
Supply and fixin repairs Stanguard Auto Transfer switch (ATS) with enclouser of capacity 200 Amp 4 pole with automatic/manual with complete protection all accessorices complete all as directed.

2

-

-

... More
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model, size suitable to DG Set of capacity upto 400 KVA including taking down old unserviceable disel feeder pump complete all as directed.

2

-

-

... More
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model, size suitable to DG Set of capacity 500 to 630 KVA including taking down old unserviceable disel feeder pump complete all as directed.

2

-

-

... More
M&L for removing old rusted painted from complete DG Set surfaces of the DG Set of capacity upto 125 KVA complete with one coat of Primer and two coats of spray painting with existing colour paint synthetic enamel type including writing Ser No of DG set complete all as specified and directed.

4

-

-

... More
Renewal of 3 pole 415 volts 50Hz Power Contractors of the following capacity including Connecting & testing complete all as directed by engineer-in Charge. (a) MNX 25 Contractor or its Equivalent

2

-

-

... More
(b) MNX 40 Contractor or its Equivalent

2

-

-

... More
S&F Repair/ replacement of timer 0 to 60 min complete all as directed.

2

-

-

... More
Comprehensive Annual Maintenance including rectification of any faults of various Fire Alarm Systems installed at DLRL & MLCP at DLRL, area including checking, testing, cleaning of Smoke Detectors, Heat Detectors, Beam Masters, Hooters, Manual Call Points, spirit bulbs etc. by carrying out preventive Maintenance and Corrective Maintenance rectifying defects in existing system and making the entire system trouble free and efficient functioning with all accessories connected to the Fire Alarm systems complete all as directed. Note: (i) Spares if any required shall be measured and paid under the relevant items of schedule and cost of labour/Fire fighting Technician/ Engineer, element like Tools/Eqpt, cleaning agents etc are deemed to be included in the quoted rate. (ii) The preventive maintenance schedule shall be as follows:- (a) MONTHLY - Checking of all cards (control card, zone card, fail card, charger card etc) in control panel for their healthly working condition. Testing of all zones by checking smoke detectors at random with smoke testing of Hooters and MCPs. (b) QUARTERLY - cleaning of all smoke detectors, heat detectors, response indicators, hooters, MCPs and Beam mastars and testing of all smoke detectors with smoke and heat detectors with heat. (iii) Service report is to be generated for the above monthly and quarterly maintenance for all the systems and submitting to Engr-in- Charge. (iv) Brakedown should be rectified as and when the system brakes down.

6

-

-

... More
Testing and Refilling of Foam type Fire Extinguisher 9 Ltrs. Capacity complete fully charged gunmetal cap heavy inner container with wall mounting brackets etc. confirming to IS: 933. Make: Safex / Geo /Konex

1

-

-

... More
Testing and Refilling of Dry Chemical Powder type Fire Extinguisher 5 Kg. Capacity powder and CO2 gas catridge of 120 gms. Capacity confirming to IS: 2171.

6

-

-

... More
Testing and Refilling of Dry Chemical Powder type Fire Extinguisher 9 Kg. Capacity powder and CO2 gas catridge of 180 gms. Capacity confirming to IS: 2171.

2

-

-

... More
Testing and Refilling of Carbon – Di – Oxide type Fire Extinguisher 4. 5 Kg. Capacity CO2 gas confirming to IS: 2878

2

-

-

... More
Taking down old unserviceable hydrant valve and Supply, Installation, Testing and Commissioning of Single Headed Hydrant valve confirming to IS 5290 with ISI mark of size 63 mm dia oblique type with instantaneous hose coupling adaptor etc. with all neceesary fittng materials complete required.

2

-

-

... More
Taking down old unserviceable hydrant hose pipe and Supply, Installation, Testing and Commissioning of Hydrant hose pipe, 63 mm dia and 2x15 mtrs long RRL type with Gunmetal 63 mm size male coupling at one end and female coupling at the other end. It should with stand a burtsting pressure of 450 psi, rot proofed, with ISI mark. Hose shall comply to IS 636

2

-

-

... More
Taking down old unserviceable hose reel pipe and Supply, Installation, Testing and Commissioning of Fire Hose Reel pipe 20 mm dia. X 30 mtr. Long, high pressure with 5 mm out let GM nozzle with shut off valve(IS: 884 - 1969) includes stop cock and chromium plated nozzle with all neceesary fixing materials complete all as directed.

2

-

-

... More
S&F in repairs sprinkler bulb Spirit type 60 to 70 degree temperature fusible range suitable for fire fighting sprinkler system complete all as directed.

8

-

-

... More
M&L for Scrapping of old existing paint of pipe lines for Fire fighting system of any sizes and applying two coats of enemel paint to match with the existing shade complete all as directed. Note - Rate quoted shall be deemed to include cost of Paint & tools. Make - ASIAN/SHALIMAR

40

-

-

... More
Scrapping of old existing paint of Fire cabinet (inside & outside) for Fire fighting system of any sizes and applying two coats of Red postal colour enemel paint. Note -Rate quoted shall be deemed to be include rates of Paint & tools. Make- ASIAN/SHALIMAR

2

-

-

... More
M&L for rewinding of the electric motor of 60 HP capacity duly disconnecting and taking down electric motor from the existing position and inspecting the same, transporting to workshop for repairs and bringing back. Cutting and removing the burnt out winding conductors rewinding the same with same gauge and weight of insulated super enamelled copper conductor and providing cotton insulated sleeves, varnishing, drying, refixing in position checking the alignment along with pump set connecting up with the electrical system, testing and commissioning complete all as directed.

1

-

-

... More
Repair and servicing of 60 to 100 HP Fire Fighting Pump and motor including all connecting parts by replacing gland, greasing & oiling and rectification of alignment of pump and motor, cleaning the carbon from the electrical connections and commissioning complete all as directed.

1

-

-

... More
Repair and servicing of 7.5 to 12.5 HP Fire Fighting Pump and motor including all connecting parts by replacing gland, greasing & oiling and rectification of alignment of pump and motor, cleaning the carbon from the electrical connections and commissioning complete all as directed.

1

-

-

... More
S&F of following parts of Fire fighting system with all necessary electrical connection with lugs of any size and testing commissioing including taking down the same complete all as directed.

-

-

-

... More
Contactor for fire Panel MNX 70 3Pole Make : L&T/C&S

1

-

-

... More
Electronic Timers Type ET 100 ML-6, 9-30 Sec, 415V, 50 Hz Make : L&T/C&S

1

-

-

... More
High Pressure control guage 02-14 Bar, 0-55 PSI , KP-36 Make : Denfoss

1

-

-

... More
S&F DWC pipe 40 mm HDPE double wall corrugated pipe cable ducting, underground electrical conduits complete all as specified and directed.

50

-

-

... More
S&F in replacement PVC Junction box of size 250x200x100mm,light weight pole mounting including MCB SP 10Amps including necessary busbar MCB mounting arrangement and necessary connector for looping in and looping out cable connection and suitable glands including taking down old unserviceable junction box complete all as directed. Make :- SINTEX or techno commercially equal in Hensil and C&S

50

-

-

... More
S&F in repairs GI street light with 4 feet mast arm for poles SP-25 to SP-31 as per the site requirements fixing on top of the pole with necessary nuts and bolts including shifting the existing street light from the bracket and connecting up with three core flexible cable by making necessary holes on the poles complete for passing the copper cable concealed in the pole including removing of spikes installed on existing pole complete all as directed.

40

-

-

... More
Supply and fix in repairs Stanguard ON-LOAD Change over switch of capacity 200 amps to 400 Amp with advance neutral along with sheet steel enclosure/ panel mounted type as per site reqiurement (W/E), AC23A ,415V, 50Hz, confirming to IS:13947-3 complete all as directed.

1

-

-

... More
Supply and fix in repairs Stanguard ON-LOAD Change over switch of capacity 800 to 1000 amps with advance neutral along with sheet steel enclosure/ panel mounted type as per site reqiurement (W/E) , AC23A ,415V, 50Hz, confirming to IS:13947-3 complete all as directed.

1

-

-

... More
S&F repair LED down light 12 W high colour rendering index (CRI90) lumien efficacy of 100 Lm/W 2.5 KV voltage surg protection power factor 0.9 housing made from powder coated die casted aluminium day light (5000K) complete all as specified and directed. Make:- BAJAJ CAT NO. BPSLR12WNW OR EQUIVALENT Phillips/ Jaguar

6

-

-

... More
S&F repair Mount LED Bollard light 10W Sturdy Ip 65 LED bollard with excellent light out put through its PMMA window ensuring maximum illumination aspect in surrounding including base foundation and nuts,bolts connections complete all as specified and directed. Make:- Shakti CAT NO SZPGBMX010 orHavells CAT NO. 10 W LED 857PSYMTOPPMMAM OR EQUIVALENT Phillips/ Jaguar

20

-

-

... More
S&F repair Mount Coral LED Post top Lamp 40W designed with symmetrical light distrubtion,spun aluminium landscape luminarie with high power LEDs as light source suitable for pole 40/50mm dia complete all as specified and directed. Make:- Shakti CAT NO SZPGMX0405 or Havells OR EQUIVALENT Phillips/ Jaguar

40

-

-

... More
Supply & Laying, jointing & testing of XLPE UG LT cables, insulated, PVC sheathed aluminium conductor multi stranded armoured heavy duty 1100 Volt grade laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs for the following cable sizes all as directed. Make: HAVELLS/UNIVERSAL/CCI/GLOSTER/KEI/POLYCAB/KEC INTERNATIONAL (RPG)

-

-

-

... More
6 sqmm 4 core

200

-

-

... More
10 sqmm 4 core

200

-

-

... More
16 sqmm 4 core

300

-

-

... More
25 sqmm 3.5 core

300

-

-

... More
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables and getting out in soft/loose soil complete all as directed.

162

-

-

... More
Returning, filiing in, including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick each, using soil complete all as directed.

145.8

-

-

... More
Removing excavated surplus soil obtained from excavation to a distance not exceeding 1.5 m above the starting point, complete all as specified.

16.2

-

-

... More
S&F in repairs LED 90 watt street light fitting made up of pressure die cast housing with toughened glass and individual LEDs with street optics and IP 66 protection, 5700K including fixing to pole/wall with necessary copper wire twin core for connection from source to fitting, nuts, bolts and washers complete all as directed. Make Shakti Cat NO SZPSLPM090 or Havells, Model No:- ENDURAOMNIPLUSSL90WLED757SASYTOPC / Wipro Cat par No. LR02-102-XXX-57-G2 or Equivalent in Philips/ Crompton greaves

90

-

-

... More
S&F in repairs of LED 45 watt street light fitting made up of pressure die cast housing with toughened glass and individual LEDs with street optics and IP 66 protection, 6500K including fixed to pole/wall with necessary copper wire twin core for connection from source to fitting, MS clamp & accessories complete all as directed. Make:- Shakti Cat NO SZPSLPM090 Havells cat part No: ENDURASUNDOWNSL45WLED765PASYBOPC / Wipro cat part No. LR-02-501-XXX-57-XX or Equivalent in Philips/ Crompton greaves

80

-

-

... More
S&F in repairs LED street light 60 W secondary optics made in pressure die cast housing and heat shrink in aluminium extrusion and IP 66 protection, 5700K color temperature fixing to the bracket or street light pole with necessary copper wire twin core for connection from source to fitting nuts and bolts as required at site complete all as directed. Make:-Shakti Cat NO SZPSLPM060 or Havells cat part No: ENDURAOMNIPLUSSL60WLED757SASYTOPC /Wipro Cat part No.LR02-331-XXX-67-XX or Equivalent in Philips/ Crompton greaves

80

-

-

... More
S&F in repairs LED street light 100 W secondary optics made in pressure die cast housing and heat shrink in aluminium extrusion and IP 66 protection, 5700K color temperature fixing to the bracket or street light pole with necessary copper wire twin core for connection from source to fitting nuts and bolts as required at site complete all as specified and directed. Make:- Shakti Cat NO SZPSLPM100 or Havells Model No: ENDURAOMNIPLUSSL100WLED757SASYTOPC / Wipro Cat part No.LR06-311-XXX-67-XX or Equivalent in Philips/ Crompton greaves

40

-

-

... More
S&F in repairs LED 250 watt high mast/flood light fitting made up of pressure die cast housing with toughened glass and individual LEDs with IP 66 protection, 5700K including fixing to High mass pole/truss with necessary copper wire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. Make Shakti SZCFLPH250 or Philips, Model No:- BVP483 LED185 CW SWB PSU GR or Equivalent in Havell's Crompton greaves

15

-

-

... More
S&F in repairs LED 150 watt high mast/flood light fitting made up of pressure die cast housing with toughened glass and individual LEDs with IP 66 protection, 5700K including fixing to High mass pole/truss with necessary copper wire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. Make Shakti SZCFLPH150 or Philips, Model No:- BVP483 LED185 CW SWB PSU GR or Equivalent in Havell's Crompton greaves

25

-

-

... More
S&F in repairs LED 100 watt high mast/flood light fitting made up of pressure die cast housing with toughened glass and individual LEDs with IP 66 protection, 5700K including fixing to High mass pole/truss with necessary copper wire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. Make Shakti SZCFLPH100 or Philips, Model No:- BVP483 LED185 CW SWB PSU GR or Equivalent in Havell's Crompton greaves

10

-

-

... More
S&F in repairs LED 120 watt highbay light fitting made up of pressure die cast housing with toughened glass and individual LEDs with IP 66 protection, 5700K including fixing to High mass pole/truss with necessary copper wire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. Make Shakti SZHHCPX120 or Havells, Model No:- SAUCERGENXHBP120WLED757P90DBOLTG or Equivalent in Philips/ Crompton greaves

15

-

-

... More
S&F in repairs LED 150 watt highbay light fiitting made up of pressure die cast housing with toughened glass and individual LEDs with IP 66 protection, 5700K including fixing to High mass pole/truss with necessary copper wire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. Make Shakti SZHHCPX150 Havells, Model No:- SAUCERGENXHBP150WLED857PNBBORL or Equivalent in Philips/ Crompton greaves

10

-

-

... More
Re-stringing, tightening and fixing in position, the existing OH ACSR conductor LT Line phase with neutral and earth wire 230V, 2/3 wire by loosening and taking down existing binding wire from the insulator of any size of ACSR conductor and bringing it to required sag including provision of new binding wire and tightening of cross arms on each pole and required trimming of tree branches Note: 1.Span length (any No of wires)of conductor shall be measured in running meter unit. 2.Unit rate quoted by the contractor shall be deemed to include for cutting and trimming branches of the trees coming in contact with ACSR conductor and separators as directed.

2100

-

-

... More
Cutting/ trimming / punning tree branches overhanging or interfering or obstructing electrical pole or street lights in such a way that the clearance between Street light pole and tree branches should not be less than 3 mtrs around the Pole/Fitting complete all as directed. (Note: Quoted rate is deemed to include necessary hydraulic ladder arrangement and tree cutting machine and tools required at site.)

400

-

-

... More
M&L for scrapping down and removing of old deteriorated paint from steel tubular poles LT preparing surface for painting and applying black & yellow paint strips of 30 cms each upto 1.5 m above the PCC and applying one coat of red oxide and two coats of aluminium paint for the remaining height of pole including MS clamps, GI bracket, fittings etc and marking of pole No, 2m above the PCC muff, letter shall not be more than 6 cm height with 16 cm dia circle around the marked No. complete all as directed. Note : Quoted rate is deemed to include removal of any type of boards, direction plates etc and refixing the same after painting, in its original position with necessary bolts and nuts.

280

-

-

... More
S&F in repairs automatic timer switch distribution board, factory assembled in powder coated sheet steel enclosure, 3Phase, suitable upto 12KW load, comprising of 32 Amps, 3 Pole, MCB TPN, 40A power contactor and 415V digital timer switch for controlling street lights outdoor type, including angle iron base and stand for fixing the panel with suitable PCC foundation as per site requirement . Make: SWADEEP Havells Cat Part: IHXSS01060 or equivalent in L&T/Legrand/Indo Asian

2

-

-

... More
S&F in repairs automatic timer switch distribution board, factory assembled in powder coated sheet steel enclosure, suitable for upto 5KW load single phase comprising of 25 Amps SP MCB, 25A power contactor and 230V digital timer switch for controlling street lights, including angle iron base and stand for fixing the panel with suitable PCC foundation as per site requirement . Make: SWDEEP Havells Cat Part No : IHXTS09120 or equivalent in L&T/Legrand/Indo Asian Note:- Rate quoted shall be inclusive of necessary excavation & earth work and PCC foundation.

8

-

-

... More
S&F in repairs polymer white , Grey or Green Pin type shakle type or any type LT as per site requrment insulator of 1.1KV grade including one galvanised mild steel strap washers, bolts, washers and nuts complete all as directed. Make - RashtriyaElectrical/ BHEL/ National

50

-

-

... More
S&F, in repairs stay assembly complete with accessories as shown in electrical plate No.1 of SSR part I including loop type insulator, stay clamps, stay strands, excavation & earthwork and PCC work complete all as specified and directed. Note:- Rate quoted shall be inclusive of necessary excavation & earthwork and concrete as required.

2

-

-

... More
M&L for painting the pole number on the LT/Street Light pole in circular shape with black synthetic enamel paint background and white synthetic enamel painted letters. Note:- The numbers and words shall be all as directed by the Engineer-in-charge.

600

-

-

... More
S&F Electronic driver for 20/25 watts LED security light fittings Make : Is certified

40

-

-

... More
S&F Electronic driver for 36/35 watts LED security light fittings Make : Is certified

10

-

-

... More
S&F Electronic driver for 45/50 watts LED road way/Flood light/post top Make : Is certified

70

-

-

... More
S&F Electronic driver for 60/70 watts LED road way/Flood light/post top Make : Is certified

50

-

-

... More
S&F Electronic driver for 90/100 watts LED road way/Flood light/post top Make : Is certified

50

-

-

... More
S&F Electronic driver suitable for 120watts LED street light/Flood light fittings. Make : Is certified

30

-

-

... More
S&F Electronic driver suitable for 150watts LED street light/Flood light fittings. Make : Is certified

25

-

-

... More
M&L for MS plate/sheet plain or cheuered,4.00 mm thick cut to pices as required and fixed to MS frame work by means of electric arc/gas welding all as directed and specified. .

50

-

-

... More
M&L for Preparation of metal surfces of any description, applying two coat of SM synthetic enamel paint of color as directed by the Engr-in-charge over a coat of red oxide primer complete.

50

-

-

... More
Supply and spreading of natural, clean, dry, river sand in trenches for cable protection / transformer yard/ two pole structure yard complete all as directed. Note:- Punned thickness only shall be measured for payment purpose.

64.8

-

-

... More
M&L for laying of common burnt bricks, sub class 'B', old size 230 x 115 x 75mm in trenches for cable protection complete all as directed.

6.96

-

-

... More
Supplu and fix GI tubing 50 mm Tubes, 'light grad', galvanised, with all fitting; laid in trenches complete all as directed.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.