Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Tamil Nadu Generation And Distribution Corporation Limited - TANGEDCO Tender
Eprocure
Opening Date4 Sep 2021
Closing Date18 Sep 2021
Tender AmountRefer Documents
Costs
EMD
₹ 53,510Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_EB_209682_1Bid Award Id
ViewTender No
Enq.no.W-307Tender Authority
Tamil Nadu Generation And Distribution Corporation Limited ViewPurchaser Address
-Website
http://https://www.tangedco.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Regular Maintenance related Works of Electrical division including EM MRT CandI and Control Room Operation
BOQ Items
... More
MAINTENANCE WORKS IN CCR:
Inspection of all equipments in CCR like panels servers, DCS Modules etc.,Cleaning of equipments and Maintenance of Maintaining Control Supply to panels, DCS etc., as directed by the Engineer in charge ( Once in a week)
15000
-
-
... More
Dismantling and refixing of instrument lines during Mechanical Maintenance, Taking periodical vibration readings and maintenance of Matrix double acting actuators etc., as directed by the Engineer in charge
137.5
-
-
... More
Break down Maintenance
20
-
-
... More
OPERATION:
-
-
-
... More
Assisting operator in CCR for monitoring and recording important parameters and readings
4392
-
-
... More
Racking IN or OUT of 6.6 KV VCB, LT ACB at switch gear room and removing of module fuses,etc
364
-
-
... More
Assisting the main control room operators during unit start up/shut down.
25
-
-
... More
Assisting operator in CCR for recording parameters and readings at GBC,IAPA,STG,GTG,BOP,CW areas
549
-
-
... More
Checking for any abnormality, sound ,leakage etc., in each shift
549
-
-
... More
Taking reading in energy meters in switch yard control room, switch gear room, CW MCC
183
-
-
... More
Assisting operators DG set trial runs GT on line water wash fire water Deep borewell pump start/stop
549
-
-
... More
opening and closing of valves in Deaerator and other areas
549
-
-
... More
Checking and taking readings of SF 6 Gas pressure checking glow specific gravity of all batteries
549
-
-
... More
Electrical Maintenance :
-
-
-
... More
Maintenance of modules below 45 KW rating Regular (Once in two month) & Break down.
690
-
-
... More
Maintenance of modules which includes LT breaker/45 KW and above rating regular (Once in two month) & Break down
200
-
-
... More
Rectification of LIGHT fitting below 4.5 meter height
296
-
-
... More
Rectification of LIGHT fitting 4.5 meter height and above height
120
-
-
... More
Maintenance of LT motors below 25 HP /18.5 KW rating Regular (once in two months) & Break down
450
-
-
... More
Maintenance of LT motors 25 HP /18.5 KW rating and above Regular (Once in two months) & Break down
115
-
-
... More
Maintenance of HT motors Regular (once in three months) & Break down
20
-
-
... More
Maintenance of 110 KV isolators, CTs, CVTs, LAS, SF 6 gas top up etc. Regular (once in two months) & Break down
125
-
-
... More
Maintenance of Circuit Breaker Regular (once in two months) & Breakdown
50
-
-
... More
Maintenance of power transformer Regular (once in three months) & Break down
15
-
-
... More
Maintenance of Batteries (once in a week).
21761
-
-
... More
Maintenance of carbon brush for GTG excitation
7
-
-
... More
Extention of temporary supply
175
-
-
... More
Repainting of electrical equipment
100
-
-
... More
Monitoring taking daily walk down checklist for drive states for EM. Healthiness of transformers, switchyard breakers, isolators healthiness & important parameters of entire plant
182
-
-
... More
Monitoring taking daily cleaning of all motors and inspection all switch gear MCC etc.
6
-
-
... More
Maintenance of lighting transformers and 500 KVA Transformer regular (once in three month)& break down
14
-
-
... More
Lifting and Re-erection of shallow bore well motor
7
-
-
... More
Maintenance and checking of quarters main supply
480
-
-
... More
Light up works of GTG /STG area as directed by engineer
12
-
-
... More
Removal of links in generator power transformer by opening cover and fixing links and closing of cover as requested by MRT wing for annual testing
2
-
-
... More
Meter and Relay Testing :
-
-
-
... More
Calibration of voltmeter/Ammeters/Timers Includes safe release of meter/timer from panel /testing of meter & meter and physical verification, cleaning attending minor defects, repairs/adjustments, refixing of meter/timer, checking for correctness and restoring normalcy, handling of testing kits / equipments and maintaining of registers etc., as directed by the engineer in charge
113
-
-
... More
Calibration of KW /KVAR/PF/KWh/ Trivector Meter and all transducers including safe release of meter / transducer from panel / testing and physical verification, cleaning attending minor defects, repair /adjustment, refixing, checking for correctness and restoring normalcy, handling of testing kits/equipments and maintaining of registers etc, as directed by the engineer in charge.
25
-
-
... More
Calibration of Bimetallic relays Electromagnetic relays and static relays including safe release of relay from panel/testing relay and physical verification, cleaning attending minor defects, repair /adjustment, refixing, checking for correctness and restoring normalcy, handling of testing kits /equipments and maintaining of register etc, as directed by the engineer in charge.
325
-
-
... More
Testing of Numerical relays, including safe release of relay from panel /testing of relay and physical verification, cleaning attending minor defects, repairs /adjustments, refixing of relay, checking for correctness and restoring normalcy, handling of testing kits/equipments and maintaining of registers etc., as directed by the engineer in charge.
15
-
-
... More
Testing of AVR, SEE/SFC, Generators and power transformers,110 KV and 11 KV Circuit Breakers, handling of testing kits/equipments and maintaining of registers, etc, as directed by the engineer in charge.
10
-
-
... More
Testing and troubleshooting of breakers upto 6.6 KV rating, lighting transformers, HT and LT Motors, handling of testing /equipments,CT secondary circuit tightness checked and maintaining of registers etc, as directed by engineer in charge.
60
-
-
... More
Lubricating cleaning, checking of control circuits tightness and healthiness in both end ( local and module end) ,Disconnection and Reconnection of control cables on motorized valve/smart MOV’s and maintaining of registers etc, as directed by engineer in charge.
50
-
-
... More
Limit setting of torque and limit switch of motorized valve/Smart MOVs checking of control circuits and maintaining of registers etc, as directed by engineer in charge
30
-
-
... More
Troubleshooting of control circuit problems in all type of HT< modules, checking for tightness healthiness cleaning of all type of control and relay panels, UPS, chargers, LT&HT modules, control and annunciation panels, fire panels, fire detectors and CO2 fire protection, etc., and maintaining of registers etc, as directed by engineer in charge.
560
-
-
... More
Troubleshooting and Cleaning of SCADA, routine maintenance of,Intercom,PA system, as directed by Engineer in charge
75
-
-
... More
Assistance to the maintenance engineers during GTG & STG start up and Shut down, commissioning of new equipment & other activities as directed by engineer in charge
18
-
-
... More
Monitoring, taking daily walk down check list of all important parameters in the station, checking of all fire systems and checking of all intercom connection healthiness
182
-
-